Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L1 | Accepted-AOC AOC | |
| 2 | L2₹2.3 L+₹2,980 (1.29%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹2.3 L+₹3,219 (1.39%)Rejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹2.3 L+₹3,373 (1.46%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest |
| Sl No | Description | Qty | Unit | UJJWAL MUKHERJEE L1 | Swarnendu Sarkar L3 | TAPAN KUMAR SARKAR L2 | MANDAL TRADERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Labour charges for repairing of indoor and outdoor unit of 2.0 Tr split AC machineand incl. all equipment and refitting the same. | 12 | Each | 2,652 ₹31,824 Lowest | 2,664 ₹31,968 | 2,665 ₹31,980 | 2,665 ₹31,980 |
| 2.00 | Labour charges for repairing of indoor and outdoor unit of 7.5 Tr. AC machine incl. existing compressor and elec. wiring and all equipments and refitting the same after necy. Repairing. Etc | 1 | Each | 1,925 ₹1,925 Lowest | 1,940 ₹1,940 | 1,938 ₹1,938 | 1,935 ₹1,935 |
| 3.00 | Supply, installation, testing & commissioning of Scroll Compressor 2.5 Ton capacity and fixed the same in existing position with necessary arrangement to complete the installation as per direction of EIC. | 2 | Each | 15,890 ₹31,780 Lowest | 16,050 ₹32,100 | 16,049 ₹32,098 | 16,065 ₹32,130 |
| 4.00 | Taken down indoor unit complete with accessories and cleaning, washing by water and soap solution. The scope of work incl refixing at the same as per direction of EIC. | 3 | Each | 450 ₹1,350 Lowest | 472 ₹1,416 | 471 ₹1,413 | 471 ₹1,413 |
| 5.00 | Supply & fixing new 50W, 620 RPM indoor fan motor for 7.5 ton Concealed split as per sample. | 4 | Each | 3,925 ₹15,700 Lowest | 3,939 ₹15,756 | 3,938 ₹15,752 | 3,940 ₹15,760 |
| 6.00 | Supply & fixing swing motorfor 2.0 Tr split AC machine as per sample. | 10 | Each | 642 ₹6,420 Lowest | 660 ₹6,600 | 655 ₹6,550 | 668 ₹6,680 |
| 7.00 | Supply & Fixing 2.5 KW, 230V Printed circuit board (PCB) for 2.0 Tr split AC machine | 8 | Each | 7,635 ₹61,080 Lowest | 7,667 ₹61,336 | 7,660 ₹61,280 | 7,665 ₹61,320 |
| 8.00 | Supply & fixing Thermostate sensor for 2.0 Tr. Split AC machine as per sample. | 12 | Each | 419 ₹5,028 Lowest | 438 ₹5,256 | 435 ₹5,220 | 440 ₹5,280 |
| 9.00 | Supply & fixing Cooling coil for 2.0 Tr. Split AC machine as per sample. | 2 | Each | 2,590 ₹5,180 Lowest | 2,634 ₹5,268 | 2,630 ₹5,260 | 2,632 ₹5,264 |
| 10.00 | S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC. | 14 | Mtr | 153 ₹2,142 Lowest | 167 ₹2,338 | 165 ₹2,310 | 168 ₹2,352 |
Tender Value
Refer Docs
EMD Value
₹5,886
Closing Date
29 Jul 2024, 9:55 amClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Repair of AC machine and replacement of parts of some AC machine of Govt. College of Nursing, BSMC, Bankur.
2024_WBPWD_719261_1
WBPWDTE/ AE /BMCESD /NIQ-25/ Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,886
Yes
7 Jul 2026
22 Jul 2024
31 Jul 2024
22 Jul 2024
29 Jul 2024
22 Jul 2024
Amount
Labour charges for repairing of indoor and outdoor unit of 2.0 Tr split AC machineand incl. all equipment and refitting the same.
Labour charges for repairing of indoor and outdoor unit of 7.5 Tr. AC machine incl. existing compressor and elec. wiring and all equipments and refitting the same after necy. Repairing. Etc
Supply, installation, testing & commissioning of Scroll Compressor 2.5 Ton capacity and fixed the same in existing position with necessary arrangement to complete the installation as per direction of EIC.
Taken down indoor unit complete with accessories and cleaning, washing by water and soap solution. The scope of work incl refixing at the same as per direction of EIC.
Supply & fixing new 50W, 620 RPM indoor fan motor for 7.5 ton Concealed split as per sample.
Supply & fixing swing motorfor 2.0 Tr split AC machine as per sample.
Supply & Fixing 2.5 KW, 230V Printed circuit board (PCB) for 2.0 Tr split AC machine
Supply & fixing Thermostate sensor for 2.0 Tr. Split AC machine as per sample.
Supply & fixing Cooling coil for 2.0 Tr. Split AC machine as per sample.
S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3 mtr)
Nitrogen flashing, Cleaning & Lick Testing of Cu pipe & all system for damaged machine
Supply & Charging full quantity refrigerent Gas (R 22)
TAPAN KUMAR SARKAR
Swarnendu Sarkar
MANDAL TRADERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .