RAMAKANT TIWARI
VCS Quality, Bharat Petroleum Corporation Limited
ELECTRICAL & INSTRUMENTATION WORKS FOR ATF PIPELINE FROM BPCL PIYALA DISPATCH TERMINAL TO JEWAR INTERNATIONAL AIRPORT
16922
100024114234
Open Tender
Works
VCS Quality
₹10 L
29 Jan 2025
28 Jun 2024
9 Aug 2024
28 Jun 2024
9 Aug 2024
28 Jun 2024
28 Jun 2024 - 2 Jul 2024
SUMMARY SHEET FOR
SCHEDULE OF RATES FOR
ELECTRICAL AND INSTRUMENTATION WORKS
FROM BPCL PIYALA DISPATCH TERMINAL TO JEWAR INTERNATIONAL AIRPORT
Name of the Bidder:
Sr. No. | Description of work | Total Amount inclusive of all applicable taxes & duties except GST (CGST&SGST/UTGST or IGST).
1 | STATION WORK - ELECTRICAL (PART-A) |
2 | STATION WORK -INSTRUMENTATION (PART -B) |
3 | Sub Total Amount (inclusive of all applicable taxes & duties excluding GST) [1 & 2)] |
4 | GST @ ________18__% on net Total amount mentioned at SI. No. 3 above. |
5 | Grand Total Amount (Including GST) |
SCHEDULE OF RATES- PART A (ELECTRICAL)
STATION WORKS - ELECTRICAL & INSTRUMENTATION
FOR BPCL PIYALA TERMINAL TO JEWAR INTERNATIONAL AIRPORT CROSS COUNTRY ATF PIPELINE PROJECT
BIDDER NAME: | M/s………………………………………………………
Item No. | Description of Item | Unit | TOTAL Quantity | Unit Rate
inclusive of all applicable taxes & duties except GST (CGST&SGST/UTGST or IGST) | Total Amount
inclusive of all applicable taxes & duties except GST (CGST&SGST/UTGST or IGST)
(in INR) | (in INR)
A | ELECTRICAL WORKS { including Supply, installation, testing, commissioning (SITC) }
Sl. No. | Description of Item including Supply, installation, testing, commissioning (SITC. - Any required further detailing please refer tender SOW, SLD, STDS. & Specifications. )
1 | Supply & Modification works in Existing HT 11 KV O/G Feeder 11 KV Main Electrical power distribution Panel for DT:- Supply, installation, testing, commissioning (SITC) of required materials for 11 KV Main Electrical power distribution Panel as per SLD -C241112-01-EL-SLD-4001: Including SITC.
2 | Existing HT & LT Main Panel Modification for DT :-Existing 11 KV, 1250KVA transformer Feeders convert to New 11 KV,2000KVA(1600 secondery +400 tertiary) KVA transformer panel O/G feeder :-All Required Material for modification & protection as per OISD requirements including Supply, installation, testing, commissioning (SITC) of Existing 11 KV Main Electrical power distribution Panel. (Set means supply of all materials, wires, and door modification, CT, PT, base plate replacement/modification, and updating of existing switch gears protection setting including Relay coordination of modified and existing panels along with submission of report) | SET | 2 |
3 | Supply of New 2000 (1600 Secondery +400 Tertiary) KVA, 11 KV/415V Secondery/415V, Tertiary Transformers with On load tapchanger panels for DT :-Supply of New 2000(1600 secondery +400 tertiary) KVA, 11 KV/415V secondery/415V, tertiary transformers with On load tap changer panels with All Required Material for protection as per OISD requirements including Supply, installation, testing, commissioning (SITC) of 2000(1600 secondery +400 tertiary) KVA, 11 KV/415V secondery /415V, tertiary transformers with On load tap changer panels. (Set means supply of all required materials, replacement/modification, and updating of existing power protection setting). Including Dismantaling & removal of existing transformer, including new transformer relay coordination/protection settings, hi-pot testing of existing cables being used can be considered. Work also includes shifting of existing 1250 KVA old transformer to BPCL desigered storage yard in Piyala plant. Scope also includes supply and installation of copper flexible connection between the transformer secondary and the existing busduct.
The terminal and terminal box for the tertiary winding shall be suitable for termination of at least 4 nos of 3.5 core x 350mm2 cables. | SET | 2 |
4 | Design, Engineering and Modification in transformer end of existing 2800A Aluminium bus-duct & Supply of 2800A fexible Copper busbar with bimetal strip for connection to existing bus-duct, at the new transformer for DT :-Modification & Supply of 2800A fexible Cu, busbar for new transformer to existing busduct connection with All Required Material for matching bus bar sizes with protection requirements including | SET | 2 |
5 | MAIN DISTRIBUTION PANEL for DT as per SLD- C241112-01-EL-SLD-4001 Including SITC |
5.1 | MAIN DISTRIBUTION Panel for DT Including SITC - Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of ILDB as per SLD , 415 V, 4 pole, 50 KA, suitable for 3 phase neutral, 4wire 50Hz, fabricated in compartmentalized from CRCA sheet steel not less than 1.6 mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete 415V panels will have a short circuit with stand capacity of 50 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref. single line diagram. single front type, Indoor type installed in existing substation building consisting of bus bar chamber, cable alley, Indicative feeders are incomer 03 nos with B/C of 630A ACB 4 Pole & Outgoing ACB outgoing as per SLD, Panel complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares etc complete in all respects as specified in technical specification, data sheet & SLD, weather/(with hinged cover) sheet steel enclosure of approved make having 4 Pole ACB for Incoming & out going circuit complete with wiring, indication lamp, ammeter etc including all labour and materials as per specification and direction of Engineer-in-charge. (SITC). ACBs shall be with motorized spring charging. | Nos. | 1 |
5.2 | Polycorbonate 230V MOV Panel DT-Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer's works, packing, delivery at site, installation and commissioning of 230V, 10 KA, 50Hz Fixed Type MV Switchboard (UPS DB) made of THERMOPLASTIC POLYCARBONATE and ingress Protection IP-42 as per IS/IEC-61439 having 230V SPN Bus with outgoing feeders as per SLD. Panel shall be single front type, wall mounted Indoor UPS AC DB as per SLD for new substation building consisting of bus bar chamber, cable alley, Indicative feeders are incomer DP MCB & Outgoing MCB complete with wiring, indication lamp, ammeter, voltmeter, KWH meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD . | Nos. | 1 |
5.3 | Polycorbonate 415V MOV Panel DT-Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer's works, packing, delivery at site, installation and commissioning of 415 V, TPN, 50Hz Fixed Type MV Switchboard (UPS DB) made of THERMOPLASTIC POLYCARBONATE and ingress Protection IP-42 as per IS/IEC-61439 having 415 V SPN Bus with outgoing feeders as per SLD. Panel shall have 100A MCCB, 415 V, 16KA single front type wall mounted indoor, MOV panel as per SLD. MOV Panel consisting of bus bar, cable alley, Indicative feeders are as per SLD as incomer TPN MCCB with contractors and outgoing MCCB's feeders wit TPN MCCB outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD including (SITC). | Nos. | 1 |
5.4 | Polycorbonate 230 V UPS, MOV Panel DT -Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer's works, packing, delivery at site, installation and commissioning of 230 V, 50Hz Fixed Type MV Switchboard (UPS DB) made of THERMOPLASTIC POLYCARBONATE and ingress Protection IP-42 as per IS/IEC-61439 having 230 V SPN Bus with outgoing feeders as per SLD. Panel shall have 63 A MCCB, 230 V, 10 KA single front type wall mounted indoor, MOV panel as per SLD. MOV Panel consisting of bus bar, cable alley, Indicative feeders are as per SLD as incomer MCCB with contractors and otgoing MCCB's feeders with DP MCCB outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD including (SITC). | Nos. | 1 |
5.5 | FLP 230 V UPS, MOV Panel DT -Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of 63A MCCB, 230 V, 10KA single front type wall mounted indoor 230V, MOV panel as per SLD to receive input power From Existing Main existing subtation MOV Panel consisting of bus bar, cable alley, Indicative feeders are as per SLD as incomer DP/ MCCB with contractors with outgong MCCB's Feerders MCCB, outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD including (SITC) (SIMILAR TO ITEM NO 2.7 but Not Polycorbonate) | Nos. | 1 |
5.6 | Polycorbonate 230 V UPS, LDB Panel DT -Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer's works, packing, delivery at site, installation and commissioning of 230 V, 50Hz Fixed Type LDB made of THERMOPLASTIC POLYCARBONATE and ingress Protection IP-42 as per IS/IEC-61439 having 230 V SPN Bus with outgoing feeders as per SLD. Panel shall have 63 A MCCB, 230 V, 10 KA single front type wall mounted indoor, LDB panel as per SLD. LDB Panel consisting of bus bar, cable alley, Indicative feeders are as per SLD as incomer MCCB with contractors and otgoing MCCB's feeders with DP MCCB outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD including (SITC). | Nos. | 1 |
6 | Modification of Existing 230V /415V AC Main Panel O/G Feeders for DT (Conversion of SFU feeders to MCCB feeders ):-Design Engineering, Manufacturing, assembly, inspection, testing, packing and Supply of All Required Material for modification & protection as per OISD requirements including Supply, installation, testing, commissioning (SITC) of Existing Main Electrical power distribution Panel modification materials and regain the power supply without any existing system power failures : Including SITC. (*= Set means supply of all MCCB, wires, and door modification, base plate replacement/modification and removing of existing switch gears) |
6.1 | Modification of outgoing feeder in existing 230VAC distribution panel for Instrumentation Panel (SFU feeders convert to MCCB feeders ) for 230V AC UPS DISTRIBUTION BOARDS for DT:- Blank dummy cubicle is available in the existing UP AC DB. Work involves Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of Including SITC, 63A SWITCH FUSE UNIT WITH FAST ACTING SEMICONDUCTOR FUSE 63A, suitable for 230 V AC, 50Hz, UPS supply
All Required Material of switch and fast acting semiconductor fuses for modification & protection as per OISD requirements including Supply, installation, testing, commissioning (SITC) of Existing 230V UPS Main Electrical power distribution panel including SITC. | SET | 1 |
6.2 | Modification of outgoing feeder in existing 230VAC distribution panel for MOV Panel O/G Feeder (SFU feeders convert to MCCB feeders ) for 230V AC UPS MOV DB for DT:- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of Including SITC, 230 AC UPS , 63 A MCCB , 50 Hz, 2 Pole, O/G Feeders in Existing AC UPS Main Panel Modification :-All Required Material for modification & protection as per OISD requirements including Supply, installation, testing, commissioning (SITC) of Existing 230V UPS Main Electrical power distribution panel including SITC. | SET | 1 |
6.3 | Modification of Existing 415V Main Panel (76-PC-301) O/G 160A SFU, star delta starter Feeder (SFU feeders convert to MCCB feeders ) for New Main Emergency supply for new Electrical panel for DT :- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of Manual MCCB 630A+630A contactor with local ON/OFF controls.
Scope includes All Required Material and labour for modification & protection as per OISD requirements including Supply, installation, testing, commissioning (SITC) of Existing 415V Main Electrical power distribution Panel : Including SITC. * | SET | 1 |
7 | MAIN DISTRIBUTION BOARDS (PMCC)-Including SITC- as per SLD for RT, SV & Remote SV |
7.1 | MAIN DISTRIBUTION BOARDS for RT Including SITC (MDB) - Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of MDB as per SLD, 415 V, 16 KA, suitable for 3 phase neutral, 4wire 50Hz, with Type-2 SPD oneencted to the load side of the incomers fabricated in compartmentalized from CRCA sheet steel not less than1.6mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete MDB panels will have a short circuit with stand capacity of 16 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref single line diagram. single front type, Floor mounted Indoor panel for New substation building consisting of bus bar chamber, cable alley, Indicative feeders are 250 Amp. 2nos. incomer & B/C 1 no. TPN MCCB with contractors & Outgoing;- DP MCB outgoing complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD -C241112-02-EL-SLD-4001 , weather/(with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB/RCBO as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including Panel shall be designed with bottom entryand all labour and materials as per specification and the direction of Engineer-in-charge. (SITC). | SET | 1 |
7.2 | Polycorbonate MOV Panel for RT -Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of MOV DB as per SLD , 100A MCCB with contractors, 415 V, 25KA single front type wall mounted indoor 415V, MOV panel to receive input power From Existing Mainexisting subtation MOV Panel consisting of bus bar, cable alley, Indicative feeders are as per SLD - C241112-02-EL-SLD-4001 as incomer TPN MCCB with outgong MCCB's Feerders TPN MCCB with contractors, outgoing complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD including (SITC) | SET | 1 |
7.3 | MAIN DISTRIBUTION BOARDS for SV- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply Including SITC (MDB) as per SLD - 415 V, 160 A, 16 KA with Type-2 SPD oneencted to the load side of the incomers, suitable for 3 phase neutral, 4 wire, 50Hz, fabricated in compartmentalized from CRCA sheet steel not less than 1.6mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete MDB panels will have a short circuit with stand capacity of 16 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design per drawings and documents, specification, codes and standards and direction of consultant / owner.(ref single line diagram. single front type, Foor mounted panel for New substation building consisting of bus bar chamber, cable alley, Indicative feeders are 160 Amp. 2nos. incomer TPN MCCB with contractors & Outgoing complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD- C241112-03-EL-SLD-4001 , weather/(with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB/RCBO as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification and the direction of Engineer-in-charge. (SITC). | SET | 1 |
7.4 | MAIN DISTRIBUTION PANEL for Remote SV Including SITC (MEDB) - Design Engineering, Manufacturing, Assembly, Inspection, Testing at shop, packing and Supply of MEDB , 415 V, 4 pole, 50 KA, suitable for 3 phase neutral, 4 Wire 50Hz, fabricated in compartmentalized from CRCA sheet steel not less than 1.6 mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. The complete 415V panels will have a short circuit with stand capacity of 50 KA for 1 Second, IP 42 rating. The panel shall have a common copper earth bar Suitable size at the rear with 2 Nos. earth studs, Design per drawings and documents, specification, codes and standards and direction of consultant / owner Indoor type installed in existing substation building consisting of bus bar chamber, cable alley, Indicative feeders are incomer 02 nos with 01 nos B/C of 32 A , 4 Pole MCCB & outgoing 16 A 4P 9 Nos. MCCB Panel complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares etc complete in all respects as specified in technical specification, data sheet , weather/(with hinged cover) sheet steel enclosure of approved make having incoming & out going circuit complete with wiring, indication lamp, ammeter etc including all labour and materials as per specification and direction of Engineer-in-charge. (SITC). | SET | 1 |
7.5 | 48 V DC DB for Remote SV- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of DCDB as per SLD, 9 KA single front type, wall mounted Indoor 48V DC DB for New substation building consisting of bus bar chamber, cable alley, Indicative feeders are 100 Amp. 2nos. incomer DP MCB & Outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD - as per SLD -C241112-03-EL-SLD-4001. All MCBs shall have required protection. (including SITC) | SET | 1 |
8 | STATIC STABILISER 415V 50 KVA for SV- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of Including SITC (STATIC STABILISER 50 KVA) - 415 V and Voltage Variation of +/- 20%, 16 KA, with input & output isolation MCCB and bypass arranhement with Type-2 SPD connected to input side of the stabilier suitable for 3 phase neutral, 4 wire, 50Hz, fabricated in CRCA sheet steel not less than 2mm thick, powder coated with approved shade and oven dried. The complete STATIC STABILISER will have opertating range of 350 V to 450V with 415 V constant voltage at full load. complete with wiring, indication lamp, ammeter, voltmeter, etc including all lmaterials with operating mechanism, all accessories, mandatory spares as per specification complete in all respects as specified in technical specification, data sheet & SLD - C241112-03-EL-SLD-4001, sheet steel enclosure of approved make having complete with wiring,indication lamp, ammeter etc including all lmaterials as per specification and the direction of Engineer-in-charge. (SITC). | SET | 2 |
9 | Solar Power System, Remote SPV POWER SOURCE- at Remote SV as per SLD- C241112-04-EL-SLD-4001
System Design, Detailed Engineering, procurement of materials, Inspection/FAT (Factory acceptance test), Supply of materials, Transportation, loading/unloading of 10 KWp Solar System (Minimum 500Wp solar module rating shall be selected and solar module design shall preferably be MONO PERC / Bi facial type) with 2 X 500 AH OPzS battery bank with three days autonomy (72 Hrs Backup) for required load for twenty four hours operation per day as per tender specification, data sheet, scope of work enclosed including commissioning spares as required at remote SV station. Solar panel support structure shall be suitable for wind speed tolerance of 150kmph. Solar charge controller shall be compatible of boost, including SPDs required in AJBs. AJBs shall be CRCA material, powder coated, weather proof type, All cables and wire used shall be UV, FRLS protected .
Solar Power System will consist of following as minimum with Two years warranty of entire system:
1. Solar Panel/ Arrays (2X50%) - 2x5 KWP along with Module Mounting Structure (MMS)
2. MPPT type Solar charger controller (2X50%) - 2x100A (min.) - Modular design (N+1 configuration with each module min 50 Amps)
3. OPzS Battery Banks / Racks, Battery accessories (2X50%) - 2x500AH
4. 2 Nos. Grid chargers - 2x50% (3 nos.1-phase type, DSP based) - each single phase charger 40A (minimum).
5. DC-DC Converter in dual redundant donfiguration (output 24V DC, 1.5 kW)
6. Interconnecting cables among arrays, charge controller, battery bank, junction boxes etc including supply of all accessories like cable glands, cable tray, tinned-cu lugs etc as required.
7. Earthing and lightning protection system as required to complete the system.
8. Erection materials & Other miscellaneous work
Battery Chargers for Remote SV-Design, Engineering, Manufacturing, assembly, testing at shop, packing and supply of complete equipment for 415V TPN to 48 V DC Battery Charger (free standing and floor mounted. 48V DC Battery Charger shall be with 2 X 100%, Dual FCBC (float cum boost charge) + 1 FC (float charge) of suitable rating to recharge the bank (2X500 AH OPZS) from fully discharge condition to 100% charge state in 10 hours.
Incoming for FCBC Charger shall be input Power supply voltage of 320 V-460V TPN, 50hz and outgoing for DCDB shall be 48 V DC. Mandatory spares shall be provided as per technical specification & SLD. DC Load shall be as per attached load list. supply including Complete in all respect, procurement of material and bought out components, packing, delivery of 48V DC power system. Including mislinious required materials, loading & unloading of all the chargers related works of items. | SET | 1 |
10 | UPS 15 KVA for RT Power Supply System-Including SITC |
10.1 | UPS for RT - Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of UPS of 15 kVA rating UPS includes System procurement of materials, Inspection/FAT (Factory acceptance test), for PARALLEL UPS (2 X100%) with BYPASS arrangements and solid state voltage stabilizer for Bypass, suitable for input Power supply voltage of 320 V-460V TPN and 230 ± 1% output AC supply, Charger rating Shall be suitable KW rating for UPS system 15 kVA rating 2nos X100% PARALLELredendent with bypass arrangements, UPS, 415 V, 3 Ph incoming with SPD & 230V outgoing AC supply UPS Suitable for charging the 2 nos x 50% Battery banks (OPZS, 2 V each cell). UPS shall be as per SLD & Specification, Bidder’s scope includes System Design, Detailed Engineering (as per tender SLD- as per SLD -C241112-02-EL-SLD-4001, specification, data sheet, scope of work and block diagram enclosed), procurement of materials, Inspection/FAT (Factory acceptance test) Supply of all required materials, Transportation, loading/unloading, insurance of complete UPS system. | SET | 1 |
10.2 | BATTERY BANKS FOR RT :-Design, Engineering, Manufacturing, assembly, testing at site, packing and supply of complete equipment for output 48 V DC Battery banks (OPZS, 2 V) backup suitable for 2 hours and battery cell quantity shall not be less than 340 Cell (2x170 cell), Cell Voltage 2 V, 2 x 100 AH. Battery banks shall be As per Data sheet & Specification, Bidder’s scope includes System Design, Detailed Engineering (as per Battery charger requirements & Battery banks specification, data sheet, scope of work enclosed), procurement of materials, Inspection/FAT (Factory acceptance test)Supply of materials, Transportation, loading/unloading, insurance of complete set including SITC. | SET | 1 |
10.3 | 230 V AC UPS-MOV DB for RT:- Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of UPS-MOV DB as per SLD, 230 V As per sld & Specification 16 KA single front type, wall mounted Indoor UPS - MOV AC DB for New substation building consisting of bus bar chamber, cable alley, Indicative feeders are 63 Amp. 2 nos. incomer TPN MCB, SPD & Outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD - as per SLD -C241112-02-EL-SLD-4001, . All MCCBs shall have required protection. (SITC) | SET | 1 |
11 | Battery Chargers for SV- Design, Engineering, Manufacturing, assembly, testing at shop, packing and supply of complete equipment for 415V TPN to 48 V DC Battery Charger (free standing and floor mounted. 48V DC Battery Charger shall be with 2 X 100%, Dual FCBC (float cum boost charge) + 1 FC (float charge) of suitable rating to recharge the bank (2X1000AH OPZS) from fully discharge condition to 100% charge state in 10 hours.
Incoming for FCBC Charger shall be input Power supply voltage of 320 V-460V TPN, 50hz and outgoing for DCDB shall be 48 V DC. Mandatory spares shall be provided as per technical specification & SLD. DC Load shall be as per attached load list. supply including Complete in all respect, procurement of material and bought out components, packing, delivery of 48V DC power system. Including mislinious required materials, loading & unloading of all the chargers related works of items.
BATTERY BANKS FOR SV- Design, Engineering, Manufacturing, assembly, testing at site, packing and supply of complete equipment for 48 V DC Battery banks (OPZS, 2 V each cell ) backup suitable for 48 hours, and battery capacity shall not be less than 2x1000AH (48 Cells i.e., 2x24 nos. cells).As per std & Specification, Bidder’s scope includes System Design, Detailed Engineering (as per Battery charger & Battery banks specification, data sheet, scope of work enclosed), procurement of materials, Inspection/FAT (Factory acceptance test)Supply of materials, Transportation, loading/unloading, insurance of complete set including SITC. | SET | 1 |
12 | 48 V DC DB for SV , Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply of DCDB as per SLD, 9 KA single front type, wall mounted Indoor 48V DC DB for New substation building consisting of bus bar chamber, cable alley, Indicative feeders are 100 Amp. 2nos. incomer DP MCB & Outgoing complete with wiring, indication lamp, ammeter, voltmeter, KWH Meter etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per specification, auxiliaries etc complete in all respects as specified in technical specification, data sheet & SLD - as per SLD -C241112-03-EL-SLD-4001, . All MCBs shall have required protection. (including SITC) | SET | 1 |
13 | DC to DC Converter for SV: 48 V DC for 24 V DC-DC, 1000 W Converter for SV:-Supply, installation, testing & commissioning of 48V DC to 24V DC converter with 1000W rated output power, working in parallel as shown in single line diagram. The DC-DC converters, their input/output citcuit breakers and 24V DC distribution MCBs shall be mounted in a common box/panel. SLD -C241112-03-EL-SLD-4001, | SET | 2 |
14 | DC to AC Inverter for SV: 48 V DC for 230V DC-AC, 5000 VA Inverter for SV:-(output 230V AC, Parallel redendent Inverter auto operated system suitable 2 nos incomer switchgear wtith outgoing feeders. | SET | 2 |
15 | Backup Power Supply for SV & Remote SV Stations -Including SITC |
15.1 | CPCB IV Compliant SILENT DG SET for SV- 415 V, 50hz, 40 KVA rating
Design Engineering, Manufacturing, assembly, inspection, testing, packing and Supply of CPCB IV Compliant SILENT 40 KVA , 415V, 50 HZ, DG set, Including Installation, Testing & commissioning With diesel tank of 990L capacity, DG set to have remote START /STOP with AMF Panel, Acoustic enclosure, silencer, exhaust, commissioning spares, as per codes, standards, datasheet & Specifications.
DG set control system shall be hardwired/soft link communication with PLC/microprocessor-based, DG set to have remote START /STOP with AMF panel for status monitoring & control of DG system from remote control room
Installation includes exhaust piping with acoustic insulation and aluminium cladding suitable for DG set installation near a single storey building. | SET | 1 |
15.2 | Porta Cabin (at Remote SV):-Supply & installation of porta cabin of size (6M x 10M) made up of approved quality steel sections/ frame work complete as per Specification no. C241112-CS-SP-6001 for Porta Cabins & drawing attached in bid document including associated civil foundation works. | SET | 1 |
15.3 | 11/0.415 kV, 100 KVA Transformer (at SV):-Design Engineering, Manufacturing, assembly, inspection, testing, packing and Supply of 415V AC power supply requirements, Including Installation, Testing & commissioning of transformer with all required transformer protection requirements as Engineering & local distribution power supply authority standard | SET | 1 |
15.4 | 2-POLE Structure Subtation (at SV):- Design Engineering, Manufacturing, assembly, inspection, testing, packing and Supply of Two pole subtation requirements, Including Installation, Testing & commissioning Including RCC pole 9 meter(As per SEB Std. 2 nos), HT Metering Set with ,CT*& PT SET, , Disk & Pin insulators sets, Lightning arrestor set, AB switchesset, DO fuse set, stay set, rms, MS clamps,nut- bolt, supporting chanels & steel structures, 160 A MCCB With box , Connection ACSR Conductor & 3.5 C X 120 sqmm, XLPE Cable, earthing strip with Earthing Electrode set for neutral & body earthing 4 nos, Guard wires , danger boards, anti climbing steel set, | SET | 1 |
15.5 | 11/0.415 kV, 63 KVA Transformer (Remote SV):-Design Engineering, Manufacturing, assembly, inspection, testing, packing and Supply of 415V AC power supply requirements, Including Installation, Testing & commissioning of transformer with all required transformer protection requirements as Engineering & local distribution power supply authority standard | SET | 1 |
15.6 | 2-POLE Structure Substation (Remote SV):- Design Engineering, Manufacturing, assembly, inspection, testing, packing and Supply of Two pole subtation requirements, Including Installation, Testing & commissioning Including RCC pole 9 meter(As per SEB Std. 2 nos), HT Metering Set with ,CT*& PT SET, , Disk & Pin insulators sets, Lightning arrestor set, AB switchesset, DO fuse set, stay set, rms, MS clamps,nut- bolt, supporting chanels & steel structures, 160 A MCCB With box , Connection ACSR Conductor & 3.5 C X 120 sqmm, XLPE Cable, earthing strip with Earthing Electrode set for neutral & body earthing 4 nos, Guard wires , danger boards, anti climbing steel set, | SET | 1 |
16 | Earthing System |
16.1 | Supplying and Earthing & Lightning pit with GI earth pipe, 3.0 mtr long, 100 mm dia including Cu clading accessories and providing masonary enclosure with cover plate having locking arrangement etc, (with charcoal and salt ) as required as per IS 3043. . | SET | 80 |
17 | Earthing Materials:- Supply and installation of GI earthing strips (100 micron galvanization thickness) for earth grid and connection of various equipment |
17.1 | GI Strip (50X6) mm (SITC) | MTRS | 1350 |
17.2 | GI Strip (25X3) mm (SITC) | MTRS | 1300 |
17.3 | GI Wire flexible (16 Sqmm) and all balance earthing material including copper strip, jumper for flanges etc. as per the specification (SITC) | MTRS | 205 |
17.4 | Flexible Single Core Copper Cable (10 Sqmm dia) Unarmoured as per the specification (SITC) | MTRS | 280 |
18 | Lightning Conductor Finial |
18.1 | Providing and fixing of lightning conductor finial, made of CU tube, having single prong at top 01 meter long , with suitable dia / rod with base plate including holes etc. complete as required including Earthing strip slives for insulation.. | Nos. | 2 |
19 | Cabling system-Horizontal and vertical laying including termination, testing (before & after laying) and commissioning of following , HV/LV.(power )/ L.V.(control) Cu/ Al cables pre-fabricated cable trays/ racks, on already installed risers, supports, hangers, saddles etc pulling through pipes on walls/ columns, steel structures including transportation of cable drum from Owner's point of issue to the site, unrolling the drum, laying the required length of cables including supply and fixing of necessary G.I. saddles, saddle bars, cable tag, G.I. / Al clamps for cables laid vertical on walls/ columns/ structures, risers, trefoil clamps of appropriate size for single core cables, preferably of FRP or Polycarbonate material, etc. with all labour, consumable material and necessary hardwares to make installation complete in all respect as per approved standard drawings and direction of Engineer in charge. Scope includes excavation, backfilling, providing sand and bricks in cable trenches Scope includes Supply, installation, testing and commissioning., Supply testing laying of U/G & A/G All power cables , fire retardant & low smoke, hi-pot testing of termination and cable post laying, for use on High voltage systems heavy-duty type 11 kV grade with aluminium conductor XLPE FRLS, fire resistance (as per IS-7098 (Part-2) including supply of Termination KIT, double compression Nikel plated Cable Glands , lugs Complete in all respect as per items detail below- Scope includes Supply, installation, testing and commissioning. |
19.1 | 3CX300 sqmm XLPE AL fire resistance 11 kV grade Armoured if required. | MTRS | 195 |
19.2 | Supply of Installation, Testing and commissioning of Cable Termination Kits for 3C x 300Sq.mm.AL. Armoured-For 11kV grade. Termination Kit includes Lug Sealing Tubes,Lugs,Cleaning Solvent Pouches,Worm Clips,Tinned Copper Braid,Stress Control Mastic,Sealing Mastic,PVC Insulation Tape,Ferrules,Black Sealing Mastic,Tartan tape,Stress Grading Mastic etc. complete in all respect. if required. | SET | 8 |
20 | Cabling system-Horizontal and vertical laying including termination, testing (before & after laying) and commissioning of following , HV/LV.(power )/ L.V.(control) Cu/ Al cables, fire retardant & low smoke, meggering of termination and cable post laying, cable termination shall be provided with ferrules and cable end cover shrouds including fabrication of cable trays/ racks, on already installed existing cable trays, supports, hangers, saddles etc pulling through pipes on walls/ columns, steel structures including transportation of cable drum from Owner's point of issue to the site, unrolling the drum, laying the required length of cables including supply and fixing of necessary G.I. saddles, saddle bars, cable tag, G.I. / All clamps for cables laid on horizontal and vertical on walls/ columns/ structures, risers, trefoil clamps of appropriate size for cables, GI / FRP material, etc. with all labour, consumable material and necessary hardwares to make installation complete in all respect as per approved standard drawings and direction of Engineer in charge. Scope includes maual excavation, backfilling, providing sand and bricks in cable trenches Scope includes Supply, laying, termination, testing and commissioning of 1.1kV grade XLPE insulated, PVC sheathed, FRLS fire resistance power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. (SITC) including supply of , double compression Nikel plated Cable Glands & lugs also including excavation and supply of soft /hard soil with backfilling. Complete in all respect as per items detail below- Scope includes Supply, installation, testing and commissioning. |
20.1 | 3.5x 300 mm2 A2XFY, fire resistance (SITC) Alluminium | MTRS | 780 |
20.2 | 3x 300 mm2 A2XFY, fire resistance (SITC) Alluminium | MTRS | 2600 |
20.3 | 3.5x 70 mm2 A2XFY, fire resistance (SITC) Alluminium | MTRS | 910 |
20.4 | 3.5x 50mm2A2XFY fire resistance, (SITC) Alluminium | MTRS | 910 |
20.5 | 3.5 x35 mm2 A2XWY fire resistance (SITC) Alluminium | MTRS | 845 |
20.6 | 3x35 mm2 A2XWY fire resistance (SITC) Alluminium | MTRS | 130 |
20.7 | 4x 16 mm2 A2XWY fire resistance (SITC) Alluminium | MTRS | 1885 |
20.8 | 4x 6 mm2 2XWY fire resistance (SITC) Copper | MTRS | 6012.5 |
20.9 | 7x 2.5 mm2 2XWY fire resistance(SITC) Copper | MTRS | 3120 |
20.10 | 4x 2.5 mm2 2XWY fire resistance(SITC) Copper | MTRS | 1885 |
20.11 | 3x 2.5 mm2 2XWY fire resistance(SITC) Copper | MTRS | 585 |
20.12 | 3x 6mm2 2XWY fire resistance (SITC) Copper | MTRS | 1560 |
20.13 | FLP Nickle Plated Double Compression Cable Gland (SITC) |
20.13.1 | 3.5x 300 mm2 A2XFY, Alluminium Cable | Nos. | 8 |
20.13.2 | 3.5x 70 mm2 A2XFY, Fire resistance, Alluminium Cable | Nos. | 10 |
20.13.3 | 3.5x 50mm2A2XFY, Fire resistance, Alluminium Cable | Nos. | 20 |
20.13.4 | 3.5 x35 mm2 A2XWY, Fire resistance, Alluminium Cable | Nos. | 14 |
20.13.5 | 3x35 mm2 A2XWY, Fire resistance, Alluminium Cable | Nos. | 40 |
20.13.6 | 4x 16 mm2 A2XWY, Fire resistance, Alluminium Cable | Nos. | 35 |
20.13.7 | 4x 6 mm2 2XWY, Fire resistance, Copper Cable | Nos. | 34 |
20.13.8 | 7x 2.5 mm2 2XWY, Fire resistance, Copper Cable | Nos. | 16 |
20.13.9 | 4x 2.5 mm2 2XWY, Fire resistance, Copper Cable | Nos. | 22 |
20.13.10 | 3x 2.5 mm2 2XWY, Fire resistance, Copper Cable | Nos. | 25 |
20.13.11 | 3x 6mm2 2XWY, Fire resistance, Copper Cable | Nos. | 18 |
21 | Supply, installation, testing, commissioning of lighting fixtures, higher lumens efficiency per watt, cool day light, IP66 Stand for fixing on pole complete with mounting bracket, flame proof/non flame proof with control gear box as per the type of fixture, lamps, 4 way junction boxes etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. (SITC)& complete with supply of FLP JB All entry shall be from bottom, to avoid water ingress from top, all JB opening shall be blinded with appropriate class (gas group) metal blind plugs. Fabrication of support structure and nut bolting inside the pole and cable from JB to pole . Scope includes Supply, installation, testing and commissioning. |
21.1 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 80-100W LED luminaire with flame proof control gear Model no. FLPW- of Baliga make or equivalent) for Pump area. (SITC) | SET | 90 |
21.2 | Supply & Installation of 4 way weather proof (IP-55) JB complete with bracket for fixing, clamps/hook for lighting fixture, weather proof Cable glands, as per standard drawing & specification. (SITC) | SET | 20 |
21.3 | Supply & Installation of 4 way flameproof (Ex-d) JB complete with bracket for fixing, clamps/hook for lighting fixture, flameproof proof Cable glands, as per standard drawing & specification. (SITC) | SET | 180 |
21.4 | Supply of street light pole Hexagonal 9 M high GI, single arm with FLP JB and cable from JB to fixture, complete in all respects suitable for Hazardous Zone-2 area. Including SITC. | SET | 34 |
21.5 | Supply of street light pole 4.5 M high GI with FLP JB and cable from JB to fixture ,complete in all respects suitable for Hazardous Zone-2 area. Including SITC. | SET | 10 |
21.6 | Supply of structure mounted light half pole 50 mm dia 2 M length GI with FLP JB and cable from JB to fixture ,complete in all respects suitable for Hazardous Zone-2 area. Including SITC. | SET | 15 |
21.7 | Supply, Installation, testing & commissioning of Lighting point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FRLSH PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible FRLSH PVC insulated 2.5 sqmm copper conductor wires/cables for following items (Wiring from DB to Switchboard shall be included in the point wiring and all JB opening shall be blinded with appropriate class (gas group) metal blind plugs. Fabrication of support structure and nut bolting)- Light fixtures shall be higher lumens efficiency per watt, cool day light, Scope includes Supply, installation, testing and commissioning. | Nos. | 55 |
21.8 | Surface/ recess mounted LED lamp with 36/40 W light fixrure with LED lamp (type LCTL-40 -CDL of CG make or equivalent). (SITC) | Nos. | 40 |
21.9 | Surface/ recess mounted FLP LED lamp with 36/40 W light fixrure with LED lamp (type LCTL-40 -CDL of CG make or equivalent). (SITC) | Nos. | 8 |
21.10 | Surface/ recess mounted LED lamp with 18 W light fixture with LED lamp (type LCTL-40 -CDL of CG make or equivalent). (SITC) | Nos. | 8 |
21.11 | Exhaust fan (Industrial type 300 mm) with louvers,950 rpm,25watt. (SITC) | Nos. | 4 |
21.12 | FLP Exhaust fan (Industrial type 450 mm) with louvers,950 rpm,55watt. (SITC) | Nos. | 4 |
21.13 | Exhaust fan (Industrial type 450 mm) with louvers,950 rpm,55watt. (SITC) | Nos. | 6 |
21.14 | Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent (SITC) | Nos. | 13 |
21.15 | 20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC. (SITC) | Nos. | 6 |
21.16 | Ceiling fan with electronic regulator ( Energy efficient, 80W, 1200 mm sweep) (SITC) | Nos. | 6 |
21.17 | Wiring for fan/light point (upto10 meter) with 2.5 sq. mm FRLS PVC insulated copper conductor wire in surface/ recesses steel conduit in ceiling &wall & conceaed PVC conduit in wall, with modular switch (AHOSXXW061/101 or equivalent), modular plate, suitable GI box and earthing the point with 2.5 sq.mm.FR PVC insulated copper conductor single/ three core wire etc as required. | Nos. | 40 |
21.18 | Wiring for 300/450 mm dia Exhaust Fan point (upto10 meter) with 2.5 sq. mm FRLS PVC insulated copper conductor three core cable/wire in surface/ recesses steel conduit in roof & PVC conduit in wall,, with modular switch (AHOSXXW061/101 or equivalent), modular plate, suitable GI box and earthing the point with 2.5 sq.mm.FR PVC insulated copper conductor single /three core cable/wire complete with 5 A Socket outlet for connecting exhaust fan. etc as required. | Nos. | 8 |
21.19 | Wiring for 16 A Power point (upto10 meter) with 4 & 6 sq. mm FRLS PVC insulated copper conductor three core cable/wire in surface/ recesses steel conduit in roof & PVC conduit in wall,, with modular switch (AHOSXXW061/101 or equivalent), modular plate, suitable GI box and earthing the point with 4 & 6 sq.mm.FR PVC insulated copper conductor single /three core cable/wire complete with 5 A Socket outlet for connecting exhaust fan. etc as required. | SET | 10 |
21.20 | 3CX2.5 sqmm FLEXIBLE WIRE, CU as required with conduit. Including SITC. | MTRS | 450 |
21.21 | 3CX4 sqmm FLEXIBLE WIRE,CU as required. with conduit. Including SITC. | MTRS | 250 |
21.22 | 3CX6 sqmm FLEXIBLE WIRE,CU as required. with conduit. Including SITC. | MTRS | 250 |
21.23 | 3CX10sqmm FLEXIBLE WIRE,CU as required. with conduit. Including SITC. | MTRS | 150 |
22 | Junction Boxes , All entry shall be from bottom, to avoid water ingress from top, all JB opening shall be blinded with appropriate class (gas group) metal blind plugs. Fabrication of support structure and nut boltingScope includes Supply, installation, testing and commissioning. |
22.1 | Supply, Installation, testing and commissioning IP-55 weather proof, structure/surface mounted 6 way junction box with canopy, suitable for fixing of terminal blocks/plates at site. | Nos. | 7 |
22.2 | 415V, 63A (3 Pin, 3Ph + N + E) interlock, Flame proof type Welding Outlet with switch and matching plug - IP 55 Enclosure suitable for 3.5C x 50/70 Sq.mm. Cable (Column / Structure mounted. | Nos. | 3 |
23 | Air Conditioners Scope of includes Design Engineering, Manufacturing, assembly, inspection, testing at shop, packing and Supply, installation, testing and commissioning. |
23.1 | Supply, Installation, testing and commissioning of latest model (5 stars BEE certified inverter AC -6 TR approx = 2 TR X 03 nos ) Airconditioning Unit complete with remote,10 KW rating with standby unit, 12 Hr timer, MS Stand for outdoor unit including All the units inddor and outdoor to be mounted on MS frame structure with double earthing of each unit shall be inscope of vendor. Thermal insulation of hotline inside AC room is also in scope of vendoretc. (SITC) | Nos. | 6 |
23.2 | Supply, Installation, testing and commissioning of latest model (5 stars BEE certified inverter AC- 3 TR approx = 1.5TR X 02 nos) Airconditioning Unit complete with remote,5 KW rating with standby unit, 12 Hr timer, MS Stand for outdoor unit etc. (SITC) | Nos. | 4 |
24 | Supply of flame proof type portable type emergency light fed by a self- contained SMF battery and charger operating on input supply 240 V AC. (Preferred make: Sudhir or equivalent) Scope includes Supply, installation, testing and commissioning. | Nos. | 6 |
25 | Supply and laying of following sizes of class 'B' G.I.Pipe in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc. small civil works, including all labour and materials complete as per approved drawings and directions of Engineer-In-Charge. Scope includes Supply, installation, testing and commissioning. |
25.1 | 50 mm NB (SITC) | MTRS | 275 |
25.2 | 100 mm NB (SITC) | MTRS | 250 |
25.3 | 150 mm NB (SITC) | MTRS | 235 |
26 | Supply, Installation, Erection of following FRP Ladder/Perforated Type cable trays with covers (as per NEMA FG-1 and ASTM –E84 /IS-6746 standards) including bends, tee, crosses, horizontal and vertical splices etc. as required including supply of all fitting hardware's, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge, Ladder type, made from minimum 50mm height and 3 mm thick FRP materials of following sizes. Scope includes Supply, installation, testing and commissioning. |
26.1 | 150 mm wide (SITC) | MTRS | 225 |
26.2 | 300 mm wide (SITC) | MTRS | 200 |
26.3 | 600 mm wide (SITC) | MTRS | 1200 |
26.4 | 75 mm wide (SITC) | MTRS | 375 |
27 | Structural steel -Erection Material Scope includes Supply, installation, testing and commissioning. |
27.1 | Supply, Fabrication and erecting of MS support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of rolled MS section, pipes, plates etc including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. (SITC) | KG | 2500 |
28 | Supply and installation of the following including the materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules. Scope includes Supply, installation, testing and commissioning. (SITC) |
28.1 | Shock hazard charts complete with frame and glass (SITC) | SET | 4 |
28.2 | First Aid Boxes (SITC) | SET | 4 |
28.3 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate (SITC) | SET | 12 |
28.4 | Caution boards (Danger, High Voltage) including supply of necessary clamps, bolts and other hardware. (SITC) | SET | 10 |
28.5 | Supply and installation of Single Line Diagram and Hazrdous Area Plan printed on sun board and enclosed in glass frame Size 36" x 48". | SET | 4 |
28.6 | Supply and laying of Insulating Mats 1.1kV grade, Class and rating of usage as per standard, roll no. ISI marks shall be properly embossed in the mats with surface of anti skid coin type shall be preferred and Preferred colour be Black (as per IS:15652) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules. Scope includes Supply, installation, testing and commissioning. | SQM | 35 |
28.7 | 2.5-3.5 mm. thick 1M wide and 2 M long 11 KV Rating rubber mats, Class and rating of usage as per standard, roll no. ISI marks shall be properly embossed in the mats with surface of anti skid coin type shall be preferred & Preferred colour shall be Blue in front of of various panels, boards as per Direction of Engineer-in-charge. Scope includes Supply, installation, testing and commissioning. | SQM | 5 |
28.8 | Supply and installation of cable route markers along the cable route at an interval of 30M as well as at cable bends and joints. | SET | 80 |
29 | Excavation to required width and depth (in all types of soil including rock cutting, jungle / debris clearing whever required along the cable route) filling with 150 mm sand above and below cables and good quality approved bricks (75 mm thick) covering the cables through out the trench, back filling (after cable laying), and finally compacting as per tender specification and approved drawings, including one run of warning tape. Scope includes Supply, installation, testing and commissioning. |
29.1 | 1000mm wide x 1000mm depth | M3 | 150 |
29.2 | 500mm wide x 1000mm depth | M3 | 125 |
30 | Supply of the following test, tools and safety items |
30.1 | Toolkit with the following items (1 no each item)
Long nose pliers 135mm, Diagonal cutting pliers 110mm, Spring hook , Adjustable wrench 6", Pro-soft screw driver 3.2x75mm, Pro-soft screw driver #0x75mm , Pro-soft screw driver 5.0x75mm, Pro-soft screw driver #1x75mm, Crimping Tool 8" , Crimping Tool 8", Ratchet handle, 10pcs screw driver Bit pack , Ratchet handle, 10pcs screw driver Bit pack , 9pcs Metric Socket Utility knife (3 blades self loading), Carrying zipper bag | SET | 3 |
30.2 | Corded Electric Rotary Hammer 720W with 3 Modes, For Concrete, Metal & Wood + Carrying case, 1 Year Warranty, complete with STEEL drill bits 1Mm-10Mm In Gradation Of 1mm CONCRETE drill bits: 4mm, 5mm, 6mm, 8mm and 10mm | Set | 2 |
30.3 | LOTO box (Size 18"x15"x2" Inch - 1pc. OSHA Safety padlock with Nylon Shackle - 10pcs. Vinyl coated Hasp Small – 2 pc. Vinyl coated Hasp Premier – 2pc.) | Set | 3 |
30.4 | Gloves for Electrical safety HT (02 pairs) & LT (02 pairs) conforming to IS 4770 :
Gloves for acid resistance usage (02 pairs) | SET | 3 |
30.5 | Arc Flash Protection Kit
ATPV: 40 cal/cm2, Fabric/Material: Inherent Flame Resistant Fabric, Tested to ASTM F 1959 meet the standards of NFPA70E, including Jacket, Bib Overall, Face Mask/Hood, and Multifunctional Storage Kit Bag. | SET | 2 |
30.6 | Rubber industrial Safety Shoe/Welsafe Gum Boot, (size 8, 2 pairs) | SET | 5 |
30.7 | Digital Multimeter (Fluke or equivalent) Rugged, durable design, CAT III 600 V safety rated, Voltage, Current Diode and continuity test with buzzer, Basic dc accuracy 0.5%, | Nos | 3 |
30.8 | Digital AC Clamp Meter (Fluke or equivalent) AC current Range 999.9 Amps Accuracy 1.5% ±5 | Nos | 3 |
30.9 | Digital Insulation Tester :-Insulation Measurement and Ac Voltage Measurement capability of AC Voltage Upto 600vac
Range Selection,single Push Button Operation, LCD display, data Holding Function, Functions Icon on Display
Measurement of Insulation Resistance at selectable voltages of 500V/1000V/2500V/5000V DC.
As Per Is10656-1983, Safety Standard IEC/EN 61010-1 &61010-31, Emc Standard IEC 61326 Class B, Over Voltage Cat III,600V | Nos | 3 |
31 | All works relating to statutory approvals, lisioning from competent authority like Fire authorities, PESO. Electrical Inspectorate, Renewal energy authority, signing of Power Purchase Agreement for Solar PV system, PESO, CEA, DGMS, NEMA, SEB etc including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liaison with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards. However the official fees towards the approvals shall be reimbursed by the client for all stations.) | SET | 1 |
32 | Dismantling reinforced cement concrete manually of slabs/shelves/ waist slabs including cutting and stacking of steel bars, disposal of unserviceable materials outside our permises upto 200 mm thick as per direction of Engineer-in- Charge.Note : The rates are applicable for all heights / depths and floors including scaffolding , etc complete.
Dismantling /clearing of RCC in foundation /superstructure by mechanical means by using pneumatic /electric drill machine including disposal of unserviceable materials outside our premises to an unobjectionable place as per direction of Engineer-in- Charge Scope of work includes staraightening, scrapping, cleaning and stacking of reinforcement bars..Note : The rates are applicable for all heights / depths and floorsincluding scaffolding , etc complete. | M3 | 10 |
33 | Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations,drains,fillings, non-suspended floors, pavements & ramps or any other works etc.including the cost ofposition cement concrete of specified grade including the cost ofcentring and shuttering, tamping, ramming, vibrating,curing, in anyshape,position,thickness and finishing the top surface rough or smooth,etc. all complete as per directions of Engineer-in-charge. - All work upto plinth level 1:2:4 (1 Cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) | M3 | 15 |
34 | Dismantling carefully concrete paver bolcks of all thickness to minimise breakge and stacking serviceable items and disposal of unserviceable items outside, including levelling the surface as per direction of Engineer-in- Charge.
Note : The rates are applicable for all heights / depths and floorsincluding scaffolding , etc complete. | M2 | 40 |
35 | Supplying and laying prepolished designer Concrete (Chequered) Tiles of approved shade and design from approved manufacturers 20 mm thick laid over minimum 30mm thick mortar bedding in CM 1:4, close jointed & pointed with matching shade of pigment mixed with white cement slurry, finished to levels, slope or plumb as required, including curing,polishing etc atall leads and lifts, complete as per instructions of the Engineer Incharge. | M2 | 30 |
36 | Supply, installation, testing, commissioning of 25 kVAR Automatic Power Factor Correction (APFC) Panel for SV and Remote SV, (one each) | Nos. | 2 |
37 | Deployment of Electrician | Man- Month | 4 |
38 | Deployment of Helper | Man- Month | 4 |
Sub Total Amount without GST |
Total Amount with GST |
SCHEDULE OF RATES- PART B (INSTRUMENTATION)
STATION WORKS - ELECTRICAL & INSTRUMENTATION
FOR BPCL PIYALA TERMINAL TO JEWAR INTERNATIONAL AIRPORT CROSS COUNTRY ATF PIPELINE PROJECT
BIDDER NAME: | M/s ……………………………………………….
Item No. | Description | Unit | Quantity | Unit Rate
(inclusive of all taxes and duties except GST)
(in INR) | Total Cost
(inclusive of all taxes and duties except GST)
IN000.01.00 | Supply, Calibration , Installation, Testing & Commissioning of Instrumentation Items listed below at Dispatch Terminal, Receiving Station, SV & IV Stations.
(For details, Refer Instrumentation Datasheets, SOW, Standard drawings & Specifications of the Tender)
IN000.01.01 | Supply, Installation, Calibration and Testing and Commissioning of C- type bourdon Pressure Gauge direct mount with supply of 2-valve 3-way manifold,150mm dial, wetted part SS316, IP 65 rated, blow out protection and shatter proof heavy duty glass Inclusive of necessary accessories at Dispatch, SV, Isolation valve area and Receiving Terminal as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 21 |
IN000.01.02 | Supply, Calibration, Installation, Testing and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered SIL-2 rated Pressure Indication Transmitter direct mount with supply 2-valve 3-way manifold Inclusive of necessary accessories etc. at Dispatch, SV, Isolation valve area & Receiving Terminal as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 27 |
IN000.01.03 | Supply, Calibration, Installation, Testing and Commissioning of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered SIL-2 rated Differential Pressure Indication Transmitter direct mount with supply 5-way manifold Inclusive of necessary accessories etc. at Dispatch, SV, Isolation valve area & Receiving Terminal as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 2 |
IN000.01.04 | Supply, Installation, Calibration, Testing and Commissioning of Bi- metallic type Temperature Gauge with thermowell, direct mount, 150mm dial with supply and installation of 1.5" 300# Raise Flanged (RF) thermowell of suitable insertion length Inclusive of necessary accessories etc. at Dispatch & Receiving Terminal as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 1 |
IN000.01.05 | Supply, Installation, Calibration, Testing and Commissioning of Temperature Indicating Transmitter of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered, SIL-2 rated Inclusive of necessary accessories etc. at SV Station as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 4 |
IN000.01.06 | Supply, Installation, Calibration, Testing and Commissioning of Skin Type RTD Element with SS316 thermopad / weldpad welded type of suitable insertion length Inclusive of necessary accessories etc. at SV Station as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 4 |
IN000.01.07 | Supply, Installation, Calibration, Testing and Commissioning of Level Transmitter -Guided wave radar type of Smart HART, Ex'ia', IP-65 rated, 24 VDC 2-wire loop powered, SIL-2 rate and their acessories inclusive of supply of necessary accessories and installation at Dispatch and Receving Termional as per datasheets, standard specifications, standard installation drawings and P&ID attached with this tender. | Nos. | 6 |
IN000.01.08 | Supply, Calibration and Testing and Commissioning of Conventional type Pressure Safety Valve (PSV) for Fire case, Rating (Inlet/Outlet line size and rating):refer P&ID, Bonnet Type: Open to Drain, Case selection: Fire Case. Inclusive of supply and installation of necessary accessories at Dispatch & Receiving Terminal as per the data sheet, standard specification, standard installation drawings and P&ID attached with this tender | Nos. | 3 |
IN000.01.09 | Supply, Calibration and Testing and Commissioning of Thermal Relief Valve (TRV) for Rating (Inlet/Outlet line size and rating):refer P&ID, Bonnet Type: Open to Drain, Case selection:HOLD Inclusive of supply and installation of necessary accessories at Dispatch & Receiving Terminal as per the data sheet, standard specification, standard installation drawings and P&ID attached with this tender | Nos. | 9 |
IN000.01.10 | Supply, Installation of Weight Loss and online retrieval type Corrosion Coupons (CC) inclusive supply and installation of their accessories, 2" Access fittings at Dispatch & Receiving Terminal as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 1 |
IN000.01.11 | Supply, Installation, Calibration and Testing and Commissioning of online retrieval type Corrosion Probe/ER with online monitoring from SCADA System, Also shall be compatible to collect the data in offline mode with data logger at Dispatch & Receving Terminal as per the data sheet, standards, specifications and P&ID attached with this tender. | Nos. | 1 |
IN000.01.12 | Instrumention cable termination i.e., Signal & Control, testing and commissioning of Pig Signaller with accessories at Dispatch and Receiving Terminal inclusive of supply of necessary cable glands, termination lugs, ferrule complete with cabling, glanding, ferruling and earthing followed by testing and commissioning of complete MOV as per the site requirement. | Nos. | 4 |
IN000.01.13 | Instrumention cable terminations of Signal & Control cable, testing and commissioning of Motor Operated Valve (MOV) ON-OFF and Control Valves at Dispatch, SV, IV and Receiving Terminal inclusive of supply of necessary cable glands, termination cooper lugs, ferrule, glanding, ferruling and earthing followed by testing and commissioning of complete MOV as per the site requirement.
Note: Installation of Valve with Actuator is in the others scope. | Nos. | 50 |
IN000.02.00 | Supply, Erection, Installation, Testing and Commissioning of following F&G devices such as Gas Detectors, Beacons, Hooters and MCP, other necessary accessories etc. required to commission of the system at Dispatch & Receiving Terminal.
(For details, Refer Instrumentation Datasheets , SOW, Standard drawings & Specifications of the Tender)
IN000.02.01 | Point Hydrocarbon Detector - IR type Type, 4-20 mA HART, 2 wire 24 VDC loop powered Ex 'd', IP 67, Enclosure material SS316 with display | Nos. | 14 |
IN000.02.02 | Flame Detector - IR type Type, 4-20 mA HART, 2 wire 24 VDC loop powered Ex 'd', IP 67, Enclosure material SS316 with display. | Nos. | 6 |
IN000.02.03 | Beacon - LED Type , 24 VDC, Ex 'd', IP 67, Enclosure MOC- SS316, outdoor Hazardous area application complete with wiring and accessories | Nos. | 2 |
IN000.02.04 | Hooter 24 VDC, Ex 'd', IP 67, Enclosure MOC- SS316, outdoor Hazardous area application complete with wiring and accessories | Nos. | 2 |
IN000.02.05 | Manual Call Point - break glass type with nickel plated brass hammer & SS Chain , 24 VDC, IP67, Enclosure MOC- Stainless Steel or Alloy, outdoor hazardous area application. | Nos. | 3 |
IN000.02.06 | Calibration of Gas Detector alongwith a set of fully equipped calibration gas kit consisting of at least a cylinder / bottle of calibration gas for minimum 6 months use (of known mixture of air and gas), a pressure regulator with gauge , flexible tube / hose , adapter cap (to fit sensing head ) to enable online calibration of hydrocarbon Gas detector at DT, SV & RT | Nos. | 3 |
IN000.03.00 | Supply, Installation, Erection, Testing and Commissioning of Fire Alarm Control Panel (FACP) alongwith repeater panel in Control Room building in Dispatch, SV & Receiving Terminal Including supply, Installation, Testing and commissioning of Smoke+Heat Detectors, MCP, sounder cum strobes, Isolation module/Control module at electrical room, battery room etc.. FACP shall be of wall mounted type will be installed in Control Room including glanding, termination, ferruling, dressing etc. at both ends inclusive of supply of erection materials, cable ferrules, cable lugs, cable tie etc. for successful commissioning of FACP system.
(For details, Refer Instrumentation Datasheets , SOW, Standard drawings & Specifications of the Tender)
IN000.03.01 | Supply and Installation of Addressable type Fire Alarm Control Panels (FACP) along with Repeater Panel installed in Dispatch & Receipt Station Control Room complete with battery backup and accessories, interfaces with RTU and inclusive of Cabling, Installation, Testing and Commissioning etc. | Nos. | 2 |
IN000.03.02 | Supply and Installation of Conventional type Fire Alarm Control Panels (FACP) along with Repeater Panel installed in SV Station complete with battery backup and accessories, interfaces with RTU and inclusive of Cabling, Installation, Testing and Commissioning etc. | Nos. | 1 |
IN000.03.03 | Supply and Installation of Repeater Panel installed in Dispatch & Receipt Station Control Room complete with battery backup and accessories, interfaces with RTU and inclusive of Cabling, Installation, Testing and Commissioning etc. | Nos. | 2 |
IN000.03.04 | Supply and Installation of Repeater Panel installed in SV Station Control Room complete with battery backup and accessories, interfaces with RTU and inclusive of Cabling, Installation, Testing and Commissioning etc. | Nos. | 1 |
IN000.03.05 | Supply and installation of Addressable Multi Sensor (Smoke+Heat) detector along with and response indicator complete with wiring and accessories i.e., Isolation/Control module etc. | Nos. | 22 |
IN000.03.06 | Supply and installation of Multi Sensor (Smoke+Heat) detector along with and response indicator complete with wiring and accessories i.e., Isolation/Control module etc. | Nos. | 3 |
IN000.03.07 | Supply and installation of Heat detector along with and response indicator complete with wiring and accessories i.e., Isolation/Control module etc. | Nos. | 5 |
IN000.03.08 | Supply and installation of Manual Call Point Indoor complete with wiring and accessories etc. | Nos. | 11 |
IN000.03.09 | Supply & Installation of Sounder cum strobe (Indoor Application) etc. | Nos. | 6 |
IN000.04.00 | Installation , Assistance in Testing & Commissioning of Remote Terminal Unit (RTU) panel at Receiving Terminal, SV Station and Isolation Valve area as per the data sheet, Drawings, standards, specifications and P&ID attached with this tender.
IN000.04.01 | Installation, assistance in testing and commissioning of fully wired PLC Based Remote Terminal Unit (RTU) Panel (Free standing type, 2115 (mm) H (including 100 mm base + 15 mm anti-vibration pad) x 1200 (mm) W x 800 (mm) D) in new control room alongwith cable glanding, termination, tagging and ferruling with all the required tool and tackles, manpower, machine, MS structure supports and other related required work to commissioning of RTU panel Inclusive supply of consumable items i.e. SS316 double compression cable gland, cooper lugs, tag plates, ferrule etc. All the station instrumentation signals shall be interfaced through RTU Panel at Receiving and SV station as per the data sheet, drawings, standards, specifications and P&ID attached with this tender. | Nos. | 2 |
IN000.04.02 | Installation, Testing & Commissioning of fully wired PLC Based Solar Powered local mounted Remote Terminal Unit (RTU) Panel after river at Isolation Valve along with FTC/fiber jointing closure, Patch cords and media convertor for fiber to Ethernet convertor alongwith cable glanding, termination, tagging and ferruling with all the required tool and tackles, manpower, machine, MS structure supports and other related required work to commissioning of RTU panel Inclusive supply of consumable items i.e. SS316 double compression cable gland, cooper lugs, tag plates, ferrule etc. Instrumentation signals shall be interfaced through RTU Panel as per the data sheet, standards, specifications and P&ID attached with this tender.
Note: 1. Supply, Installation, Testing & Commissioning of Solar system and its sub-system shall be part of the Electrical work SOR item. | Nos. | 1 |
IN000.05.00 | Installation , Assistance in Testing & Commissioning of Station Process PLC and HMI System Panel at Receiving Terminal as per the data sheet, Drawings, standards, specifications and P&ID attached with this tender.
IN000.05.01 | Installation, assistance in testing and commissioning of fully wired Station Process PLC and HMI System Panels (Free standing type, 2115 (mm) H (including 100 mm base + 15 mm anti-vibration pad) x 1200 (mm) W x 800 (mm) D) in new control room alongwith cable glanding with all the required tool and tackles, manpower, machine, MS structure supports and other related required work to commissioning of PLC and HMI panels Inclusive supply of consumable items i.e. SS316 double compression cable gland, lugs, ferrule tagging etc. All the signals of electrical, instrumentation, FACP, CP and metering skid system etc. are to be interfaced through PLC Panel at Receiving as per the data sheet, drawings, standards, specifications and P&ID attached with this tender.
Note: 1. PLC system racks shall be free Issue material by client for the station contractor.
2. In PLC and HMI System, System cabinet, I/O cabinet and Marshalling cabinet shall be a seperate panel and above metioned scope are for all these cabinets. | Lot. | 1 |
IN000.05.02 | Installation of PLC/HMI/PIDS/CCTV/RTU/Printer etc. Operator Console in new control room alongwith cable glanding with all the required tool and tackles, manpower, machine, MS structure supports and other related required work to commissioning of PLC and HMI panels Inclusive supply of consumable items i.e. SS316 double compression cable gland, lugs, ferrule tagging etc. at Receiving as per the data sheet, drawings, standards, specifications attached with this tender.
Note: 1. Console cabinets shall be free Issue material by client for the station contractor. | Nos. | 7 |
IN000.06.00 | Supply, Laying, and Tagging of Armoured/Non-Armoured below indicated Instrumentation cables in all type of trenches/Cable trays/PVC conduit/HDPE duct from field instruments to field JB's, JB's to Panels and Panels to Panels, package vendor skid JB & MOV to Panels and associated works including Supply, Installation, Erection of cable trays, , Erection of hardwares, cables glands, junction boxes, ferrule, copper lugs, PVC cable tie and other necessary accessories etc. to complete the work in all respect at Dispatch terminal, Receiving terminal, SV station and Isolation valve as per the datasheets and documents, Standard drawings, Specifications and P&ID attached the with this tender.
IN000.06.01 | 1P x 1.5 Sq.mm, ‘IS’ Twisted Pair, Overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue | M | 1300 |
IN000.06.02 | 1T X 1.5 Sq. mm, Fire resistant,Overall Screened Cables | M | 800 |
IN000.06.03 | 2P x 1.5 Sq.mm, ‘IS’ Twisted Pair, Overall screen Serial Commmunication cable shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Grey | M | 2500 |
IN000.06.04 | 2C X 1.5 Sq. mm Fire Resistant cable for Beacon, Hooter, MCP | M | 800 |
IN000.06.05 | 4P x 1.5 Sq.mm, ‘IS’ Twisted Pair, Individual and Overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue | M | 4000 |
IN000.06.06 | 6P x 1.5 Sq.mm, ‘IS’ Twisted Pair, Individual and Overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue | M | 10000 |
IN000.06.06 | 6P X 1.5 Sq.mm ‘NIS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black | M | 2500 |
IN000.06.08 | 6T X 1.5 Sq.mm Fire Resistant Individual & Overall Screened, Twisted Pair overall screen shall be of XLPE.CS.PVC.SWA.PVC/Red | M | 3500 |
IN000.06.09 | 8P X 1.5 Sq.mm ‘IS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black | M | 200 |
IN000.06.10 | 8P X 1.5 Sq.mm ‘NIS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black | M | 22000 |
IN000.06.11 | 8C X 1.5 Sq. mm Fire Resistant cable for Beacon, Hooter, MCP from JB To GDS Panel. | M | 1000 |
IN000.06.12 | 12P x 1.5 Sq.mm, ‘NIS’ Twisted Pair, Overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue | M | 200 |
IN000.06.13 | Procurement of Armoured Cat-6 cable, along with laying & termination between interconnecting Panels inside the control room building, Electrical room, Battery room etc. as required. | M | 500 |
IN000.06.14 | Procurement of Un-Armoured Cat-6 cable, along with laying & termination between interconnecting Panels inside the control room building, Electrical room, Battery room etc. as required. | M | 500 |
IN000.06.15 | Supply, erection and installation of PVC cable conduits Pipe of 19 to 25 mm heavy duty, ISI Mark on walls, concrete structure etc. including supply and installation of all necessary fittings such as bends, sockets, etc. as required for laying of CAT-6 un-armroued cables, cable rising up to the equipments and other accessories such as bend, conduit clamps including cost of all labors, tools & tackles, materials etc. to complete the work in all respect. | M | 100 |
IN000.06.16 | Field mounted Analog Junction box (AJB) Ex‘d’ Type (Explosion Proof), 12 Nos. cable Input (1/2" NPTF) and 4 Nos. cable output (02 Nos. 3/4", 01 Nos. 1" & 01 Nos. 1/2"), 24 Terminal Block | Nos. | 14 |
IN000.06.17 | Field mounted Fire (Analog) Junction box (FAJB) Ex‘d’ Type (Explosion Proof), 12 Nos. cable Input (1/2" NPTF) and 4 Nos. cable output (01 Nos. 3/4", 02 Nos. 1" & 01 Nos. 1/2"), 24 Terminal Block. | Nos. | 6 |
IN000.06.18 | Field mounted Digital Junction box (DJB) Ex‘d’ Type (Explosion Proof), 12 Nos. cable Input (1/2" NPTF) and 4 Nos. cable output (01 Nos. 3/4", 02 Nos. 1" & 01 Nos. 1/2"), 24 Terminal Block. | Nos. | 5 |
IN000.06.19 | Field mounted Fire (Digital) Junction box (FDJB) Ex‘d’ Type (Explosion Proof), 12 Nos. cable Input (1/2" NPTF) and 4 Nos. cable output (01 Nos. 3/4", 02 Nos. 1" & 01 Nos. 1/2"), 24 Terminal Block. | Nos. | 3 |
IN000.06.20 | Field mounted Emergency Push Button Station (ESD) Junction box Ex‘d’ Type (Explosion Proof), 3 Nos. cable output (02 Nos. 3/4" ), 8 Terminal Block as minimum for DT, SV, & RT | Nos. | 4 |
IN000.06.21 | Supply & Installation of Cable Trays (50 mm wide x 50 mm height), Perforated Type with necessary supports and other accessories. | M | 100 |
IN000.06.22 | Supply & Installation of Cable Trays (100 mm wide x 50 mm height), Perforated Type with necessary supports and other accessories. | M | 100 |
IN000.06.23 | Supply & Installation of Cable Trays (300 mm wide x 50 mm height), Perforated Type with necessary supports and other accessories. | M | 100 |
IN000.06.24 | Excavation of trenches for buried the cables, preparation of same for laying of cable, filling with river sand, laying of brick, back filling and compacting of the excavated earth, cable route markers, etc. as per specifications including supply of sand and bricks and removal of surplus earth as per instructions of Engineer-in-Charge. Size of Trench : 1000 mm (Width) X 800 mm ( Depth) | M | 500 |
IN000.06.25 | Supply, fabrication, erection, installation and testing of all erection hardwares required for installation of field instrumentation like, JB, cable tray, SS blind plugs for JB & Panel of all size, ferrule, SS tubes for impulse tubing, SS tube fittings, valves, manifolds, flanges, brackets, clamps, MCT block with SS Frame etc. as per the standard drawings and specifications of the tender. | Lot. | 1 |
IN000.06.26 | Supply, fabrication, erection, Installation 2" MS pipe Instrument stand pipe/stanchion as per the standard drawings and specifications of the tender. | Nos. | 39 |
IN000.06.27 | Design, engineering, packing, transportation, supply & installation of Canopies required for field electronic instruments as per Technical Specifications attached with tender document. | Nos. | 39 |
IN000.06.28 | Supply, fabrication, erection of MS structure supports for Instruments panels, tray supports etc.as per drawings and specifications of the tender. | Per Kg | 100 |
IN000.06.29 | Spare parts items as per tender document (Mandatory spare list) | Lot. | 1 |
IN000.06.30 | Calibration of Field Instruments for PT/TT/DPT and gauges etc. with dedicated calibration kits of NABL certified Master instruments at DT,SV ,IV & RT | Lot. | 1 |
IN000.06.31 | Supplying and fixing G.I box along with modular base and cover plate for double RJ45 Jack modular in office room at RT & DT building as required. | Nos. | 10 |
IN000.07.00 | Installation of filtration, Metering & Regulating skid at Dispatch and Receiving Terminal
IN000.07.01 | Erection, Installation, assistance in testing and commissioning of vendor package skids i.e. filtration, Metering & Regulating skid and control room mounted metering panel with flow computer including installation of any loose/damaged skid instruments, impulse tubing, laying of multi pair cable (supplied by skid vendor) from metering skid to Metering panel in all type of trench/tray, cable glanding, termination, tagging and ferruling, calibration of skid instruments (except Mass flow meter) under the supervision of skid vendor person with all the required tool and tackles, manpower, machine, MS structure supports and other related work required to commissioning of Metering & Regulating skid Inclusive supply of consumable items as per the specification and drawings of the tender at Dispatch terminal.
1. Supply of Skid Instruments, Instrumentation cables (Branch/Skid JB to Metering panel and Gas detection panel), Junction box etc. shall be in the scope of metering skid Vendor.
2. All the installation work related to skid shall be executed under the supervision of skid vendor person.
3. All the loose material supplied by skid vendor shall be installed by station contractor scope of work.
4. Supply of cable glands at Metering panel, RTU panel and PLC panel end shall be in the scope of station contractor scope of work and all the cable glands at Skid Junction box & Instrument end shall be in the scope of Skid Vendor.
5. Laying and termination of skid branch cables in trays shall be in the scope of station contractor scope. If Required.
6. Package vendor skid shall be free Issue material by client for the station contractor. | Lot | 1 |
IN000.07.02 | Erection, Installation, assistance in testing and commissioning of vendor package skids i.e. filtration, Metering & Regulating skid and control room mounted metering panel with flow computer including installation of any loose/damaged skid instruments, impulse tubing, laying of multi pair cable (supplied by skid vendor) from metering skid to Metering panel in all type of trench/tray, cable glanding, termination, tagging and ferruling, calibration of skid instruments (except Mass flow meter) under the supervision of skid vendor person with all the required tool and tackles, manpower, machine, MS structure supports and other related work required to commissioning of Metering & Regulating skid Inclusive supply of consumable items as per the specification and drawings of the tender at Receiving terminal.
1. Supply of Skid Instruments, Instrumentation cables (Branch/Skid JB to Metering panel and Gas detection panel), Junction box etc. shall be in the scope of metering skid Vendor.
2. All the installation work related to skid shall be executed under the supervision of skid vendor person.
3. All the loose material supplied by skid vendor shall be installed by station contractor scope of work.
4. Supply of cable glands at Metering panel, RTU panel and PLC panel end shall be in the scope of station contractor scope of work and all the cable glands at Skid Junction box & Instrument end shall be in the scope of Skid Vendor.
5. Laying and termination of skid branch cables in trays shall be in the scope of station contractor scope. If Required.
6. Package vendor skid shall be free Issue material by client for the station contractor. | Lot | 1 |
IN000.08.00 | Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation inline with I/O List, Instrument Index & Specification for Instrument Installation.
IN000.08.01 | AI (FM/PT/DPT/LT/TT/DT/HGD/OPD/FD etc.) | Nos. | 44 |
IN000.08.02 | DI (Detector,FS,Hooter, Beacon MCP) | Nos. | 27 |
IN000.08.03 | MOV (AI,AO,DI,DO) | Nos. | 50 |
IN000.09.00 | Supply of below listed Flame Proof Ex-d certified Double Compression type Cable Glands with PVC shroud & earth tags of Nickel plated brass material suitable for out door terminations of armoured XLPE/PVC cables of following overall diameter & Gland sizes (excluding termination and connection of cables), , Reducers/Adapters, suitable for installation in Zone 1, Gr. IIA/IIB, T3 and weatherproof to IP 66 minimum as per IEC 60529, having valid CMRI/PESO certificate as per approved vendor list provided in the tender.
Cable gland sizes and quantity indicated below with respect to Cable OD are indicated, Contractor shall select the cable gland exactly suitable for the applicable cable sizes.
Contractor's scope also includes handling, loading/unloading, transporting, storing at contractor's site store/any other location within the project site, including all labor and material etc. complete and as per directions of Engineer-in-Charge at site.
Note- Total no. of quantity are indicative only.
IN000.09.01 | Cables with OD upto 20 mm. (Gland Size 1/2" or 1") | Nos. | 150 |
IN000.09.02 | Cables with OD upto 20 mm. (Gland Size 3/4") | Nos. | 50 |
IN000.09.03 | Cables with OD upto 20 mm. (Gland Size 1") | Nos. | 100 |
IN000.09.04 | Cables with OD above 20 mm but upto 30 mm. (Gland Size 1") | Nos. | 100 |
IN000.09.05 | Cables with OD above 20 mm but upto 30 mm. (Gland Size 1.1/4") | Nos. | 50 |
IN000.09.06 | Cables with OD above 30 mm but upto 40 mm (Gland Size 1.1/2") | Nos. | 20 |
IN000.10.00 | Termination of XLPE/ PVC insulated armoured Instrumentation cables (up to 1100 V grade) of different ODs and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the copper lug on to the conductor, Dressing, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
Note- Total no. of quantity are indicative only.
IN000.10.01 | Cables with OD upto 20 mm. | Nos. | 100 |
IN000.10.02 | Cables with OD above 20 mm but upto 30 mm. | Nos. | 100 |
IN000.10.03 | Cables with OD above 30 mm but upto 40 mm | Nos. | 100 |
IN000.10.04 | Cables with OD above 50 mm but upto 60 mm | Nos. | 100 |
IN000.11.00 | Loading, Unloading, Transportation of SRV from Bina Refinery (MP) to Jewar Terminal including supply of crane etc, securing SRV Skid and other items
IN000.11.01 | Receiving and taking over, handling, lifting, loading, transportation, and unloading of SRV Skid and associated items from BPCL Bina Refinery (MP) to worksite (Jewar Terminal, UP) / contractor's storage yard/ any other storage yard or as decided by EIC including supply of the crane. The above work also includes stacking associated items (i.e., flanges, fittings, valves, electrical & instrumentation items, etc.) properly. The above work shall be carried out as per the instruction of the Owner and other provisions of the contract document.
i) The quantity (Kms) given against above item no. is indicative and shall not be considered to be binding. The quantities may be increased, decreased, or deleted as per the requirement and instructions/recommendations of the Owner. The unit rate shall be operated to work out the final payment to the contractor.
ii) The above price shall be inclusive of all types of taxes & duties, transit insurance during transportation & other insurance, etc. including all financial & commercial implications as per the tender document. No other payment except as per the quoted unit rate & executed quantities will be payable by the Owner. | Mt-km | 3000 |
IN000.12.00 | Deployment of Instrument technician | Man- Month | 4 |
IN000.13.00 | Deployment of Helper | Man- Month | 4 |
Sub Total Amount excluding GST |
Total Amount including GST |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
16922.pdf
pdf • 40.92 MB
BUDGETDOC_16922.xlsx
xlsx • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .