THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Electrical works needed after repaire and renovation of two building (One new building and one old B.C Roy hostel) by Civil dept at NTS, R G Kar Medical College and Hospital , Kolkata
2026_WBPWD_1022480_1
WBPWD/EE/KNHED/e-NIT-23/ 25-26
Open Tender
ELECTRICAL WORKS ORG
Percentage
30 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,940
OFFICE OF THE EE KNHED PWDte.
11 May 2026
13 Mar 2026
27 Mar 2026
13 Mar 2026
25 Mar 2026
19 Mar 2026
19 Mar 2026
Dismetaling of exisiting light fittings, wall fans, ceiling fans with wiring. (1 skilled electrician + 1 unskilled electrician)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. Average run 6 mtr
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to 5A 3 pin flush type plug socket & piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish as per G S i) On Board
Supply & Fixing of following plug socket with separate Piano key type switch (Brand approved by EIC) on suitable sizes (16SWG) sheet metal switch board on wall incl. S & F bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS. i) 2 x 5 A Piano key type switch & Socket ( Separate Plug)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required i) 2 x 1.5 sqmm + 1 x 1.5sqmm
ii) 2 x 6 sqmm + 1 x 4sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S i) 6 sqmm
ii) 4 sq mm
SUB-HEAD 6- Fixing of Light fittings Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mm x 125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2 x 24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [17/C-2]
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. C-2/14.b
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/ C-2 ]
Taking down existing fl. single/ double T/L fittings and refixing the same after necessary alteration of the wiring as per led fitting with all accessories as required.
Supply of 4 Ft. single/twin LED Tube fitting for indoor application, complete with all accessories & Lamps having following Model / Cat No.( Make -Philips) i) Supply and Delivery of 4 feet Industrial box type single LED tube batten/mounting rail (rust free) suitable for for single TLED lamp. [Make- Philips/Wipro/Lighting Technology/manufacturer with own NABL accredited lab with valid test certificate]
ii) Supply and Delivery of 4 feet Industrial box type double LED tube batten/mounting rail (rust free) suitable for for single TLED lamp. [Make- Philips/Wipro/Lighting Technology/manufacturer with own NABL accredited lab with valid test certificate]
Supply & Delivery of 240V, 18/20 W LED Tube Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/Watt or better & 50,000 LED burning hours or more. [Make- Philips/Wipro/Lighting Technology/manufacturer with own NABL accredited lab with valid test certificate][LED lamps & accessories shall have BEE certification]
Supply & Delivery of 240V recess mounted round LED downlight having following wattage, in white powder coated pressure die cast alluminium housing with glare free uniform illumination, suitable for 2' x 2' grid ceiling with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/Watt or better & 50,000 LED burning hours or more. [Make- Philips/Wipro/Lighting Technology/manufacturer with own NABL accredited lab with valid test certificate][LED lamps & accessories shall have BEE certification] for 24 Watt
Fixing 240V recess mounted round LED downlight having following wattage, in white powder coated pressure die cast alluminium housing with glare free uniform illumination, suitable for 2' x 2' grid ceiling with
Supply & delivery of 230V 50Hz 450mm (18 inch) sweep heavy duty full metal body /Decorative type wall bracket fan having wattage ≤ 90 Watt, RPM ≤ 1350, Air Displacement (In CMM) ≥ 100 complete with all accessories. (Make- Orient/Crompton) [BEE star Rated] with all accessories with necy. bolts & nuts. ( Make- EPC/CG/Orient)
Supply & delivery of 230V, 1-Ph, AC ceiling fan of following size incl. all accessories. (Make- Crompton/Usha/Orient) [BEE star Rated] Sweep size- 1200 mm (48"), Wattage ≤ 55 watt, RPM ≤ 380, Air Delivery ≥ 210 CMM.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length C-4/29
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand) [ D-9 /13] 2+12 way Enclosure (607712)
Supplying and fixing 240/415 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ABB/Cabtree) [D-6/ 7] 6-10A
Supplying and fixing 240/415 V DP MCB Isolator on din rail of existing DBs and necessary connection. (Make-Legrand) [D-5/ 6]
Supply & fixing 50 mm dia heavy GI pipe 3.64 mm thick x 6.10 Mts. long By TATA-Medium GI pipe
Supplying & Fixing GI fan clam of "S" type fixing on 50 mm GI pipe hanging from ceiling as per approved specification, fabricated from 40 mm x 9 mm GI flat including making good fixing with GI pipe and satisfactory finishing (As per direction of EIC)
Add :- GST 18%
Add:- LWC 1%
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.28 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
2911.pdf
Tender Documents • 1.46 MB
BOQ_2512963.xls
BOQ • 0.37 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .