Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC as per aoc | |
| 2 | L2₹36.0 L+₹79,282 (2.25%)Rejected-AOC NO 41 21 PERAMBUR BARRACKS ROAD PATTALAM CHENNAI 12 | 12 | L2 | Rejected-AOC as per minutes | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
19 Dec 2022, 3:00 pmClosed
JOINT COMMISSIONER (PREV.)
R NO G513 5TH FLOOR MAIN BUILDING CUSTOM HOUSE CHENNAI 600001
RENOVATION WORK OF DIU R K310 AND 311 3RD FLR KRISHNA BLOCK FOR OFFICE OF PR COMMNR OF CUSTOMS (PREVENTIVE) CUSTOM HOUSE CHENNAI
2022_DREV_728027_1
GEN/INSP/MISC/189/2022-DIU(P)
Open Tender
Miscellaneous Works
Works
10 days
R NO 310 AND 311 KRISHNA BLK 3RD CH CHENNAI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹80,000
Yes
25 Apr 2023
8 Dec 2022
20 Dec 2022
8 Dec 2022
19 Dec 2022
8 Dec 2022
8 Dec 2022 - 14 Dec 2022
Amount
2 x 2 grid False ceiling with arm strong tiles with heavy duty channel.
Removal of false ceiling and clearing the debris on site
2 x 2 false ceiling light fittings LED 48 watts.
Wooden partition made up of 50x25 mm heavy duty aluminium section with 3mm wall thickness fixed in 2ft. distance vertically and horizontally and both side covered with 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI make. Removing and clearing the site of old and damaged wall panel
Supply and Fixing of UPVC sliding glass windows of size 8 x 6 ft.
Removing of old aluminium window of size 8 x 6 ft and plastering the area with cement.
Fixing of roller blinds of heavy duty fabric for windows with necessary fittings.
Removing the doors and laminating with 1mm laminate on both side and refixing the same with hardware, locks and door closure with necessary fittings
Removal of old wires and pipes
Termite treatment for entire DIU room
Painting the wall with 2 coats of putty, 2 coats of wall primer, 2coats of emulsion paint in roller finish after scrapping and removing the old paints
Supply and Fixing of 2x2 full body vitrified tiles of Johnson make crema design after removing and preparing the existing floor
Wooden Computer table of size 3x1.3 ft Made from 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI make
Wooden storage units of size 4x3x1.5 ft. – made of 19mm BWR kit marine plywood laminated on both side with 1mm laminate having wooden shutters with locking facility. Top should be 38 mm thick BWR Plyboard with both side laminated and all edges should be covered with 2mm edge bind.
Wooden Office table of size 5x 2.5x 2.5 ft Made from 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI with one drawer unit
Wooden Office table of size 4x 2x 2.5 ft Made from 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI with one drawer unit
Wooden Office table of size 6x 3x 2.5 ft Made from 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI with one drawer unit
Wooden Computer table of size 4x 1.5 ft Made from 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI with one drawer unit
Chair Medium back Godrej Model No. 002
Chair Low back Godrej make Model No. 003
Visitors Chair Godrej make 3A
Interrogation Room Partition and FurnitureWooden partition made up of 50x25 mm heavy duty aluminium section with 3mm wall thickness fixed in 2ft. distance vertically and horizontally and both side covered with 19mm BWR kit marine plywood laminated on both side with 1mm laminate of approved shade from ISI make. Removing and clearing the site of old and damaged wall panel
Wiring for light point/fan point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel / PVC conduit including dismantling as required.
Supplying and drawing 3 x 1.5 Sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit / CMS as required.
Supplying and drawing 6 x 1.5 Sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit / CMS as required.
Supplying and drawing 3x4 Sq mm size of FRLS PVC insulated copper conductor, single core cable in the existingsurface/recessed steel/PVC conduit/CMS as required.
Supplying and drawing 6 x 4 Sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ CMS as required.
Supplying and drawing 25 mm size of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing 2 run of cable of CAT 6 LAN Cable from the terminal to each work station.
Supplying and drawing of 2 pair telephone cable from the terminal to each work station.
Supplying and fixing of PVC cable management trunking of size 105 10mm x 50 mm with cover on surface as required.
Supplying and fixing of Wire/ Cable retaining clip for 105 x 50 mm PVC cable management system as required.
Supplying and fixing of Flat angle for 105 x 50 mm PVC cable management system as required.
Supplying and fixing of Flat junction for 105 x 50 mm PVC cable management system as required.
Supplying and fixing 15/16 Amp one way Anchor Roma switch, modular plate & switch box including connections etc as required.
Supplying and fixing 5/6 Amp 3 pin Anchor Roma socket, modular plate & switch box including connections etc as required.
Supplying RJ11 Telephone Anchor Roma socket outlet.
Supplying RJ 45 internet Anchor Roma socket.
Supplying and fixing 3 Module modular Anchor Roma frame and cover plate.
Supplying and fixing of 8 modular Anchor Roma plate with 3 nos 3 Pin 10 Amp socket, 1 No. 1 modular 2 pin socket plus 1 No. 15 Amp Switch for Raw Power and similar one set of 8 modular Anchor Roma plate with 3 nos 3 Pin Socket, 1 modular 2 pin socket 1 no. and 1 No. 1 modular 15 Amp Switch for UPS power.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 25 Amp modular socket outlet with 25 Amp plug top and 32 Amp modular DP switch, connection, painting etc as required (For AC connection, switch & socket to be fixed separately in different location as per the directions).
Supply, installation, testing and commissioning of optical type smoke detectors as required.
Supply, installation, testing and commissioning of Response indicators above and below the false ceiling as required.
Supplying and fixing 63 Amps rating, four pole 415 volts isolator in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 63 Amps rating, four pole (three phase and neutral), 415 volts, Residual current circuit breaker having a sensitivity current up to 300 milli amps in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing S Amps to 32 Amps rating, 240/415 volts, ’C’ series, miniature single pole circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
D-Link 24 Port Switch
3 Track Metal Box
P Manickam and Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .