| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.7 L+₹1.1 L (3.77%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹31.5 L+₹1.9 L (6.30%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹43.9 L+₹14.3 L (48.4%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹44.6 L+₹15.0 L (50.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
14 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Maint of summer appliances, cooling appliances and AC plants alongwith connected works at certain different locations under GE (Utilities) Udhampur
2023_MES_603437_1
GE/U- /2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹97,000
Yes
28 Aug 2023
15 Jun 2023
17 Jul 2023
15 Jun 2023
14 Jul 2023
30 Jun 2023
Amount
M&L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacturer with high pressure pump of 1.0/1.5/2.0 ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
M & L for cutting of suction line and discharge line tubing of AC, de-scaling of front scaled unit flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.0/1.5/2.0 ton Split/W/T type AC complete all as specified and directed by Engr-in-Charge.
M&L for detection/rectification of leakage of gas by vacume the system, charging with Nitrogen gas and vacume the system after detaction of lekage and gas charging in the system with appropriate quantity of gas as per OEM Recomentation including testing for smooth functioning of Split type/ Window type AC of capacity 1.0/1.5/2.0 Ton complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-600 in refrigerantor complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new indoor unit of split AC of capacity 1.5 ton with compitable for existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new indoor unit of split AC of capacity 2.0 ton with compitable for existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new outdoor unit of split AC of capacity 1.5 (w/o compressor) ton with compitable for existing indoor door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new outdoor unit of split AC of capacity 2.0 ton (w/o compressor) with compitable for existing indoor door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electronic control Board (PCB) of Existing Make duly ISI marked for split type AC 1.0/1.5/2.0 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electronic control Board (PCB) for inverter type split AC of existing makes duly ISI marked for 1.5 /2.0Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electronic control Board (PCB) of Existing Make duly ISI marked for window type AC 1.0/1.5/2.0 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement blower motor of Split type AC 1.5/2.0 Ton of existing make & model complete all as specified and directed by Engr-in-Charge.
S&F in replacement new rotary type AC compressor of existing split type/window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge.
All as per serial item No.17.00 here-in-before but of size 2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement new Reciprocating type AC compressor of existing split type /window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge.
All as per serial item No.19.00 here-in-before but of size 2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Evaporator coil 1.5 / 2.0 Ton complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Copper tube cover(insulation) complete all as specified and directed by Engr-in-Charge. Note: insulation of 1/4" & 1/2" dia pipe measured as one unit.
Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of unsv Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr-in-Charge.
Carry out Servicing, Oiling, Greasing and Cleaning of water cooler of capacity 40/80 ltr from authorised rep or service engineer from the manufacturer with high pressure pump, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 Ltr complete all as specified and directed by Engr-in-Charge.
S&F compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and directed by Engr-in-Charge.
M&L in replacement of starting relay and overload relay suitable for existing size and make water coolercomplete all as specified and directed by Engr-in-Charge.
Carry out Servicing, Oiling, Greasing and Cleaning of Deep freezer of capacity 300/320 ltr from authorised rep or service engineer from the manufacturer with high pressure pump, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
S&F of starting relay of deep freezer of any size complete all as specified and directed by Engr-in-Charge.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and directed by Engr-in-Charge.
S&F in repair replecement new sealed compressor suitable for Deep Freezer of single phase, 230 Volt, 50 Hz of Deep Freezer of any Size in and including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge.
S&F in repair replecement new sealed compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator of any Size in and including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge.
S&F of thermostat switch for refrigerator any make & capacity complete all as specified and directed by Engr-in-Charge.
Supply and fixing water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in-Charge.
Taking out old existing unsv coil Senser supply and fix new coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unsv heating Senser supply and fix new heating senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr-in-Charge.
Taking out old unsv blower supply and fix new blower(plastic body) of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of L -Shape thimble brass in pk(50Nos in one pkt) complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of thimble brass(50Nos in one pkt) suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable and supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton. complete all as specified and directed by Engr-in-Charge.
Fan motor1/20 HP single shaft for water cooler as per the original make of complete fan motorcomplete all as specified and directed by Engr-in-Charge.
Fan Motor 1/35HP single shaft for water cooler complete all as specified and directed by Engr-in-Charge.
Fan Motor 1/70HP single shaft for water cooler side holder, bushes with main lead. complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Fan motor with fan suitable for LG double door 286ltr / 310 Ltr refrigerators complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of fan motor of 165/170 Litre Refrigerator and supply and fix new fan motor of existing make, shape and size complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 47.00 here-in-before but suitable for single door 310 Litre Refrigerator complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement & testing of Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 49.00 Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable complete all as specified and directed by Engr-in-Charge.
Taking out old existing unsv Starting Capacitor of capacity 50+6 mfd supply and fix new Multi purpose Running Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 40+80 mfd for water cooler complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 40+60 mfd for water cooler complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 80+100 mfd for water cooler complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 120+150 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unsv Multi purpose running Capacitor of capacity 10 mfd supply and fix new Multi purpose running Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 58.00 here-in-before but Starting Capacitor of capacity 4 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 58.00 here-in-before but Starting Capacitor of capacity 20 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance complete all as specified and directed by Engr-in-Charge.
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels complete all as specified and directed by Engr-in-Charge.
Replacement of Khas khas set for the doors of desert coolers complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down unserviceable overload/PTC relay for window / split AC 1.5/2.0 ton, supply and fix new over load relay/PTC relay and testing for window / split AC 1.5/2.0 ton, satisfactory performance commissioning complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable diacharge valve and supply and fix new discharge valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable suction valve and supply and fix new suction valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable capillary and supply and fix new capillary of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable dead Nut and supply and fix new dead nut of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable NRV and supply and fix NRV of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of unserviceable remote control unit Suitable for 1.5 / 2.0 Ton split type AC working on both ( Hot & Cool) complete all as specified and directed by Engr-in-Charge.
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32 Amps, 220 Volts complete suitable for window/ Split type complete all as specified and directed by Engr-in- Charge.
Taking out old existing unserviceable DB two Way and MCB SPN 40 Amps and Supply and fix Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts by with one SPN MCB of capacity 40 Amps complete all as specified and directed by Engr-in- Charge.
S&F in replacement of MCB SPN 63 Amps, 10 KA,240V, 50Hz, 'C' Series complete all as specified and directed by Engr-in- Charge.
Taking out old existing unserviceable front show grill and supply and fix new front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in- Charge.
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA,5KVA,2KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as below complete all as specified and directed by Engr-in- Charge.
M&L rewinding of main coil (primary/secondary) of voltage stailizer with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA complete all as specified and directed by Engr-in- Charge.
All as per serial item No.78.00 here-in-before but of capacity 5KVA complete all as specified and directed by Engr-in-Charge.
All as per serial item No.78.00 here-in-before but of capacity 2KVA complete all as specified and directed by Engr-in-Charge.
M&L in replacement of relay for 7.5KVA & 5KVA,30amp 24volts DC complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Step down transformer for voltage stailizer 24 volts 2Amp for 7.5 KVA & 5KVA complete all as specified and directed by Engr-in-Charge.
M&L in replacement of circuit plate for voltage stailizer with connection wire complete all as specified and directed by Engr-in-Charge.
M&L in replacement of relay for voltage stailizer 0.5KVA, 1KVA & 2KVA,16Amp 24V DC complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Voltmeter 0- 300V, AC 75 Sqm complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Ampre meter 0- 30Amp, AC 75 Sqm complete all as specified and directed by Engr-in-Charge.
M&L in replacement of push switch complete all as specified and directed by Engr-in-Charge.
M&L in replacement of time delay circuit for voltage stailizer complete all as specified and directed by Engr-in-Charge.
M&L in replacement of connector switch 30amp 220volts AC complete all as specified and directed by Engr-in-Charge.
Repairing /Servicing and rewinding of motor 3 phase 400-440 volt complete disconnecting the electric supply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearings, greasing fo bearings including rewiring with superior quality copper winding wire insulating material, vanishing binding of winding etc complete all as directed by Engr -in-Charge reassembling, replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection completed complete all as specified and directed by Engr-in-Charge. For the following :-
Electric motor 3 phase 70 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 15 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 10 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 5 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 3 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
Repairing/ servicing of water pump including removing of old gland packing, gland bolt and fixing of new gland packing , gland bolt, cleaning of impeller/Replacement of impeller complete all as specified and directed by Engr-in-Charge for the following :-
Monoblock pumping set 10.0 HP complete all as specified and directed by Engr-in-Charge.
Monoblock pumping set 3.0 HP complete all as specified and directed by Engr-in-Charge.
Descaling of condenser after opening of both end cover, circulation of descaling solution forcibly using pump for circulating decaling solution and rubbing manually using nylon brush of size 1/4,3/8,1/2,5/8 inch descaling rod etc without damaging copper tubing and re-fixing of side cover using new gasket of rubber insulation sheet of 3mm thick and replacement of rusted nuts bolts etc complete all as specified and directed by Engr-in-Charge for the following:-
47.5TR cap Condenser complete all as specified and directed by Engr-in-Charge.
7.5TR cap Condenser complete all as specified and directed by Engr-in-Charge.
Repairing serving of cooling coil tower of AC plat FRP Type by dismantling ad taking out the one comb PVC files complete ad PV Nozzles the PVC files by suitable descaling solution including bruising and cleaning complete with cleaning solution and water replacing the defective PVC flange along with rubber gasket and rusted bolts nuts and washer etc cleaning the water sump ad XMP wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filter flanges of pipe joints etc and testing complete all as specified and directed (PVC Files will be measured ad paid separately for the following:-
95 TR Capacity plant installed at CHNC A/C Plant complete all as specified and directed by Engr-in-Charge.
50 TR Capacity plant installed at OPS room A/C Plant complete all as specified and directed by Engr-in-Charge.
12.5 TR Capacity plant installed at 37AMSD A/C Plant complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of 110 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX110) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of 32 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX32) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts,complete all as specified and directed by Engr-in-Charge.
MCCB Three pole 415 Volt 50 Hz 160 Amps wit breaking capacity 25 KA type DT complete all as specified and directed by Engr-in-Charge.
MCCB Three pole 415 Volt 50 200 Amps with breaking capacity 25 KA type complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Single phase priventer (minilec VSP D2/240 VAC Phase Failure relay) complete all as specified and directed by Engr-in-Charge.
Over load relays MK 1 Type relays range 75 to 110 Amps complete all as specified and directed by Engr-in-Charge.
Over load relays MK 1 Type relays range 44 to 75 Amps complete all as specified and directed by Engr-in-Charge.
Over load relays MK 1 Type relays range 14 to 23 Amps complete all as specified and directed by Engr-in-Charge.
Supply & fix HEPA filter 10 to 20 microns static wove both side DPE mesh in aluminium frame efficiency 90% of sizes as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply & fix factor made performance HEPA filters of 99 micro down to 5 micro of standard size with multiple pockets & self supporting filters bags with MS/GI anodised aluminium frame suitable for central AC Plant including replacement of bolts & nuts & taking down unserviceable complete all as specified and directed by Engr-in-Charge.
Provide skilled technician for attending of any breakdown of VRF type AC Plant of capacity 25 HP / 16 HP whenever required round the clock ,rectify the fault and restart the plant within three hour after receipt of complaint of any nature i.e. Compressor, Condenser, control panel etc complete all as specified and directed by Engr-in-Charge. Note -(i) The cost of replaced spare parts will be paid and measured separately. (ii) If complaint is not attended by contractor with in five hour the penalty of Rs 500 / per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
M&L for serving of air VRF type AC Plant of capacity 24 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 20 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 16 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 16 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 8HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate .
M&L for serving of air VRF type AC Plant of capacity 8HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air Handling Unit of capacity 2500 CFM by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers after painting & necessary welding including replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note:Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air Handling Unit of capacity 25000 CFM by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers replacing the suitable gasket if required complete all as specified and directed by Engr-in-Charge. Note:Necessary Nut, Bolts, washers, pickings are included in quoted rate.
All as per serial item No 12.00 here-in-before but for 5000 CFM complete all as specified and directed by Engr-in-Charge.
Supply and fix V Belt of following sizes complete all as specified and directed by Engr-in-Charge.
V-Belt B-67 complete all as specified and directed by Engr-in-Charge.
V-Belt B-68 complete all as specified and directed by Engr-in-Charge.
V-Belt B-70 complete all as specified and directed by Engr-in-Charge.
V-Belt B-124 complete all as specified and directed by Engr-in-Charge.
Supply & Fix in replacement PVC sheathed 6 sqmm 3 core copper conductor cable complete all as specified and directed by Engr-in-Charge.
CITY TOP ELECTRICAL WORKS
M/S M P Construction Co
VARDHMAN INTERNATIONAL
PREM NATH KHAJURIA AND SONS
ARNABH ASSOCIATES
K S BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .