Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.5 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST | |
| 2 | L2₹80.3 L+₹12.3 L (18.1%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 3 | L3₹82.1 L+₹14.1 L (20.8%)Rejected-Finance N I T NO EE M III WZ 2025 26 TC 72 | GURUGRAM | HARYANA | 122008 | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 4 | L4₹85.9 L+₹18.0 L (26.4%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 5 | L5₹89.1 L+₹21.1 L (31.0%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L5 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
16 Nov 2023, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
SPL REPAIR FOR THE ROOF APP ROOF TREATMENT OF BLDG TT CELL PROVN OF 235 GEYSERS 25 LTRS IN JCOS AND OR MD ACCN OF 505 ABW AND SPL REPAIR TO BLDG NO T46 DEPOT WORKERS CANTEEN OF COD UNDER AGE BR I OF GE NORTH DELHI CANTT
2023_MES_624226_1
CWE/D-15/2023-24
Open Tender
Civil Works
Works
180 days
505 ABW DELHI CANTT
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹2.0 L
Yes
11 Jan 2024
19 Oct 2023
17 Nov 2023
19 Oct 2023
16 Nov 2023
9 Nov 2023
Amount
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) all as specified and directed.
Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames) all as specified and directed.
Providing and fixing factory made uPVC white colour Sliding window area exceeding 2.00 Sqm Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.)
Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge
Supply, and fixing 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickenss. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by insering horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer and as per directions of Engineer?in-charge.
S&F mild steel pressed steel handle, oval type, stove enamelled black 150 mm long complete all as specified.
S&F aluminum anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified .
S&F Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.
M&L for demolition of stone slab and tiles of any description or thickness in floor,aprons etc laid,bedded and pointed in any mortar all as spcd and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) dark shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile. over screed bed or bedding layers of cement mortars 15 mm thick in CM 1:6 all as specified and directed.
Ditto- item No. 11 above but as in vertical surfaces such as skirting/ dado over and including 10 mm thick rendering in CM (1:4) compelete.
M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade od tile incl rendering 10mm thick in CM (1:4) and finished rough, complete all as spd & directed.
M&L Granite 18-20 mm thick colour as approved ( of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms or making hole for fix in oval shape for fixing of wash hand basin and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in cement mortar 1:6) including moulding and polishing the edges all as specified and directed
M&L Granite 18-20mm thick colour as approved ( of any type) work (table rubbed and polished) in for wall lining (veneering to wall) 12 mm thick in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding and polishing the edges etc complete.
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm thick screed bed in CM 1:4.
M & L Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm cement screed base 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Dismantling of Asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw as in roof complete all as spd .
S & F Fe 410-W(gde-E-250 quality B roof truss (framed) , trussed, purlin, crane, gantries, rails and fastening and heavy bracket framing (beam, tee, angle, channel, or flat sections) including distance pieces, cleats etc all as specified and directed
S&F 0.50mm plain, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet having tensile strength of 550 MPa as in ridges, hips, valley gutter, drip and straight flashings (length and girth as fixed) and welded or soldered joints are provided as requried complete all as specified and directed.
S&F 2mm thick PGI sheet having 120 gm of zink coating per sqm both sides in valley gutter, dripper,or as rain water pipe, straight flashing with 100mm overlap made to required shape & size incl welding or revetting and fixed in position and working height upto 15m complete all as specified and directed.
Dismantling wall and ceiling boards( fibre pulp, insulation etc.) any thickness, including cover fillets.
Providing & fixing false celling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 × 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )- 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from celling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85×25×2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
S&F 25 mm thick insulated PVC wall lining consisting of PVC insulated panels with single side prelam PVC sheet having expanded polysterene (EPS) stuck to 2mmthickplain colour PVC Sheet duly fitted into the wall as per specifications and drawing complete.
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
M&L for12 mm thick Endura tiles (Square or rectangular) area of each tile exc 0.08 Sqm but n exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4), Incl Dismantling old floor tile incl cement mortar bedding and removal of debris out of premises complete all as specified and directed.
Demolition of brick work or stone builder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete.
M & L Brickwork with subclass 'B' Brick straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Ditto- item No. 29 but except brick complete.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Removing old lime wash or other treatment exposed brick face, hacking for key, raking out joints of old brick work or stone work built in lime, cement mortar, not previously plastered; and scrubbing down with water etc. to receive plaster
M&L 15 mm thick Ready mix plaster (Make:- Ultratech readiplast /Birla Aerocon RMP /ACC Suraksha RMP ) on brickwork or concrete surfaces of wall, finished even and smooth complete all as specified and as directed by engr-in-charge.
M&L 5 mm thick Ready mix plaster (Make:- Ultratech readiplast /Birla Aerocon RMP /ACC Suraksha RMP ) on brickwork or concrete surfaces of wall (ceiling )finished even and smooth complete all as specified and as directed by engr-in-charge.
M&L for Preparing new plastered or unplastered surfaces of ceiling and applying two coats of white wash complete.
M&L for Preparing new plastered surfaces of wall and applying two coats of oil bound distemper white or tinted over and including a coat wall care putty and chalk whiting on plastered surfaces preparatory to distempering complete.
M&L for finishing walls with acrylic smooth exterior paint of reqired shade; New work (Two or more coat applied @ 1.67 ltr/10Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm.
Taking up or down steel tubing and connections 15 mm bore complete.
Taking up or down steel tubing and connections 20 mm bore complete.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 20 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete.
Dismantling PVC water tanks of capacity exceeding 250 litres but not exceeding 500 litres including ball valves complete.
Dismantling PVC water tanks of capacity exceeding 500 litres but not exceeding 1000 litres includng ball valves complete.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, ISI marked, tripple layered hoisted and fixed in position including connecting up pipes complete.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, ISI marked, tripple layered hoisted and fixed in position including connecting up pipes complete.
S & F of 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete.
S & F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic wall, screwed for iron pipe and fixed for 25 mm bore size (Minimum weight 210gms), complete.
S & F in repair Bib taps,15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete.
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced.
M&L for glossy finsihed rubber moulded colour pre polished cement concrete tiles, machine made of 22 to 25 mm thick of any size and pattern as approved by GE as per IS-1237 ultra desinger tiles indian series or its equivalent as in floors etcset,jointed pointed in neat cement slurry and including 20mm thick screed bed or bedding layer in cement mortar1:6 complete all as specifed and directed.
M&L for 18 mm thick PVC Board for kitchen cabinet/ cupboard one sided decorative lamination and other side balancing white sheet consisiting of carcass 18 mm thick PVC sheet fixed approved adhesive and self tapping screws and 20 mm wide and 1 mm thick PVC edges bending to paste on edges of PVC furnitures with suitable adhesive including all fittings and fixtures like SS shutter handle 100 mm size , magnet catcher on each pair of shutters ,door lock (Godrej) on each pair of shutters, 4 nos each auto closing hinges openable at 0 degree for each pair of kitchen shutter, ball bearing runners 45 mm telescopic chaneel (20 inch each pair ) full extension load capacity 50 kg, etc complete all as specified and directed. incl taking down old board.
S&F MS framed work such as grills, Gratings, manholes covers flat iron as in chain link fencing etc with ends of bars shouldered or reverted , frame work of water tanks and similar work conf to fe 290.Gde E 165.
S&F SFRC manhole covers and frame medium duty of overal size 900mmX450mmX80mm thick, factory made and test load 10 tonnes (MD-10), strength as per IS: 1726-1991 (Make-Polycrete) all as specified by Engineer-in-Charge.
M&L providing 1:2:4 type B-0 (12.5 mm graded aggregates) cement concrete in roof kerbs or mud stops,rounded or chamfered on edges and other similar works all as directed.
Demolition of brick tiles,terracing tiles, single layer from roof laid, bedded and pointed in any mortar all as specified & directed.
Demolition of mud phuska/cement concrete in roof any thickness, including plaster and leaping/whether full thickness removed on only a part thereof.
Removing building materials etc. to a distance of 500m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination.
M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning old surface and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 Kg/Sqm including 15mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately)
Supply only liquid water proofing compound
M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (A) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (B) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with 10cm side laps and 15cm end lap. as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE.
M & L applying two coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge.
S&F 110 mm bore PVC (SWR) Pipes single socket or with rubber ring, fixed to walls or in any position including taking down old damaged pipes complete all as specified and directed.
S&F PVC(SWR) bends plain 110mm bore complete all as specifed and directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by engr-in-charge.
S&F in repair 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended works (Rainforcement cut as required demolition) of any description and in any position not otherwise specially provided.
Excavation in trenches, n exc 1.5m wide and n exc 1.5 in depth for foundation etc or for shafts, wells cesspits manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5 m on plan and n exc 1.5m depth and getting out in mud all as specified and directed
M&L for cutting holes in brick walls in cement mortar or cement lime mortar and stone walls built in lime mortar depth of embedded portion of hold fasts or lugs exc one brick but not exc two bricks thick wall all as specified and directed
M&L for plan cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregate as in fixing of hold fast of door frame in wall all as specified and directed.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete.
M&L cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight including necessary form work and complete all as specified .
Hacking out old broken glass (any thickness, size quality or discription) from wooden frame or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
S&F sheet glass ordinary quality, 4 mm thick and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed.
Disconnecting existing tanks of capacity exc 250 ltrs and n exc 500 ltrs, setting aside (or lowering if required) for rapairs, cleaning etc and hoisting if required reconnecting and refixing in position (Cleaning repairing, etc measured separately)
M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete
M&L for prepartion of newly plastered surface of wall and applying average 2mm thick water proof putty @ 1 kg per sqm over the plastered wall prepare the surface even and smotth
M&L for applying two or more coasts of 100% premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489: 2004, Alkali & fungal resistance using Airless spray technology with max working pressure of 3300 PPSI and capable of operaitng single spray gun with a maximun material hose length of 30 mtr the spray machine appliying ACRYLIC EMULSION PAINT should be able to spray in hard to reach areas and penatration of distemper on the surface to achieve excellent appliaction using limited manpower complete all as specified and directed. Dirt resistance exerior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/ 10 sqm over surfaces including material & labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per SI 15489:2004, Alkali & Fungal resistnace to be done by dirt resistance exterior paint of required shade preparation of plastered surface of old/new plastered wall, complete all as specified (Make: Berger, Asian Paint, Nerolac).
M&L for concealed sub main wiring with 3 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit 20/25mm wiring complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable alongwith 20/25mm PVC conduit pipe shall be measured as one unit length.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning following MCBs are as under :- .
(a) SP 5 To 32 AMP
(b) SPN 40-63 AMP
M&L for sheet metal enclosure MCB distributon board, 2 way single door 230 volts all as specified and as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc.including grouting of bolts for fixing complete all as directed at site by Engr-in-charge.
S&F stop valve but fancy type, chromium plated, screwed down (CP) of size 15 mm fancy type complete all as specified and directed.
M&L bib taps , cast copper alloy with butterfly handle , screwed down, screwed for iron pipe or for brass ferrule and fixed for bib tap 15 mm dia fancy type all as specified and as directed.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete
Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for up to required module etc complete and making good to the disturbed surfaces to match the existing complete all as specified and directed for for One light / bell point/one Ceiling / exhaust fan controlled by one, one way switch 06 Amps
All as per above item here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per above item here-in-before but with point wiring 1.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sqmm single core FRLS cable for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch.
All as per above item here-in-before but with point wiring 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 5 pin, 16 Amps socket outlet point on independent board controlled by one, one way 16 Amps switch.
S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete
S&F modular bell push with indicator, 06 Amps, single pole, one way, 230 volts complete
S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete
S&F modular socket outlet 02 in 01, 03 pin, 16 Amps, 02 module with shutter complete
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts incl connection complete
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals complete
S&F surface mounting LED integrated aluminium housing batten luminaire not less than 20 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete.
S&F surface mounting LED integrated aluminium housing batten luminaire not less than 10 watt 2 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete
S&F in repair Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing of exhaust fan, steel body, AC, single phase, 230 V of size 300mm sweep with blades, frame & louver having 1400 RPM speed, 1600 CMH and including making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces to match the existing complete all as specified and as directed.
Supply and fixing of exhaust fan, steel body, AC, single phase, 230 V of size 450mm sweep heavy duty with blades, frame & louver having 1400 RPM speed, 1600 CMH and including making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces to match the existing complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete . and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete
S&F (in replacement) industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 12 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
All as per above but 8 way
S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note :- MCCB & MCB SP will be measured seperately)
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete. (Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
V r traders
R K GOEL ABHEY KUMAR JAIN
SHREE RAM BUILD TECH
Commercial Traders
M/S ANIL KUMAR
imran construction company
VED PRAKASH ARORA
M/s Verma and Co
Shiv Shankar Nirman Co.
M P TYAGI ENGINEERS AND CONTRACTORS
SHYAM ENTERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .