Loading…
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.8 L
EMD Value
₹4,000
Closing Date
5 Nov 2026, 3:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer
Room No 22, Dr. B R Ambedkar University Delhi, Lothian Road, Kashmere Gate Delhi -110006
Supplying, Installation, Testing and Commissioning of LED Street lights, flood lights, post top lantern including laying of cable in the Karampura campus of Dr. B.R.Ambedkar University Delhi.
2026_AUD_300344_1
06/EE/EMU/AUD/2026-27
Open Tender
Repair and Maintenance Works
Works
15 days
DR B R Ambedkar University Delhi, K P Campus, Del
As per NIQ
8 documents required · 8 mandatory
₹0
₹4,000
22 Oct 2026
22 Oct 2026
5 Nov 2026
22 Oct 2026
5 Nov 2026
22 Oct 2026
22 Oct 2026 - 5 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical Work | |||||
| 1.01 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50 watt | 6 | Each | 1.25 | ₹7.5 |
| 1.02 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥ 135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg - 120 deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150 Watt | 12 | Each | 1.25 | ₹15 |
| 1.03 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm | 120 | Meter | 1.25 | ₹150 |
| 1.04 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm) | 1 | Each | 1.25 | ₹1.25 |
| 1.05 | Supply and Installation of LED Post top lantern with die cast aluminium spigot, spun aluminium powder coated top cover and clear acrylic diffuser IP 65 (CAT Ref. HLPT-04-40-CW or equivalent) | 2 | Each | 1.25 | ₹2.5 |
| 1.06 | Supplying, Installation, Testing and Commissioning of 40W LED decorative post top lantern with die cast aluminium Housing and OPAL PC difusser, IP 65 ( CAT Ref. HLPT-21-40-CW or equivalent). | 3 | Each | 1.25 | ₹3.75 |
| 1.07 | Supply of 1.1 KV grade XLPE armoured aluminium conductor cable of size 3 X 10 sq.mm | 120 | Meter | 1.25 | ₹150 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_400924.xls
BOQ • 0.29 MB
Quotation.pdf
Tender Documents • 0.39 MB
tenderdownload_BOQ Light KPC.pdf
Additional Documents • 0.39 MB
tenderdownload_BOQ.xls
Additional Documents • 0.29 MB
tenderdownload_NIQpdf.pdf
Additional Documents • 0.26 MB
tenderdownload_Quotation.pdf
Additional Documents • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .