REPAIR/MAINT OF CENTRAL AC PAKAGE TYPE AC AND HOT WATER PLANT UNDER GE (AF) SRINAGAR
2019_MES_287726_1
GE(AF)-25/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF SRINAGAR
₹40,000
Yes
27 Jan 2020
7 Oct 2019
5 Nov 2019
7 Oct 2019
4 Nov 2019
21 Oct 2019
7 Oct 2019 - 14 Oct 2019
Amount
Disconnecting from system, strip opening of refrigerant compressors of 30 TR capacity completely and checking of various components with precision instruments to assess the requirements of repair/replacement, making inventories of repairs required complete and re-assembling the dismantled Compressor with re-fixing the serviceable parts in position after proper cleaning and lubricating etc, replacement of the unserviceable/defective parts with new parts as required at site, connecting the compressor and making perfectly leak proof after cleaning the oil sump, oil pump connecting rod, piston, liner etc and filling of compressor oil, charging of refrigerant gas to the required pressure and testing the compressor on full load including painting the compressor with applying one coat of synthetic enameled paint after preparation of the surfaces and writing MES Nos & other details in the pattern and style as approved complete all as specified and directed by the Engineer-in-Charge for following make & model of compressors :-(a) Model 050405 of Make VOLTAS.
Note :- (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing of the parts replaced/repaired is deemed to be included in this item. (ii) Repair of crank shaft/connecting rod etc. if any required at site shall be measured and paid separately under relevant items of Schedule `A'. However, the cost of taking out and re-fixing of the shaft / rod in position after necessary repairs is deemed to be included under the rates quoted by the contractor for above items.
M&L to assess the reasonableness of crank-shaft measurements 0.25mm, 0.50mm, 0.75 and 1.00 mm and then undertaking repair by cutting and grinding the shaft to make it equivalent to manufacturer’s standard size, shaft smoothening/ fine finishing to match with half section big end bearings, cleaning oil parts for proper lubrication for following make & model of compressors :- Note : ,The cost of taking out and re-fixing of the shaft / rod in position after necessary repairs is deemed to be included under the rates quoted by the contractor for respective Schedule `A' item No 01 (a) Model 050405 of make VOLTAS.
Supply only following items, for –Voltas Make compressors Model 050405 complete all as specified and directed :- Note : The element of fixing & testing of the items is deemed to be included in the rates quoted by the contractor for respective Schedule `A' item No.1 above (a) Connecting rod bearing inserts
(b) Seal end main bearing
(c) Piston pin
(d) Seal end bearing washer
(e) Compressor ring
(f) Seal end thrust washer
(g) Pump end bearing washer
(h) Oil Ring
(j) Suction valve disc
(k) D V Guide lock washer
(l) S V spring
(m) Valve lifter pin
(n) Valve lifter spring
(o) Seal cover plate
(p) Lock ring
(q) Felt filter
(r) Nyloc nut
(s) Discharge valve disc
(t) Seal lock plate
(u) D V spring
(v) Seal assembly
(w) Main bearing pump end
(x) Gasket set
(ae) OPRV
(af) Refrigernat gas R-22
S&F differential oil failure switch type MP-55 complete all as specified and directed. Make : Indofoss /Renco /Pan.
S&F LP control switch MP-1 complete all as specified and directed. Make : Indofoss / Renco / Pean.
S&F HP control switch MP-5 complete all as specified and directed. Make : Indofoss / Renco / Pean.
S&F ‘V’ belts of following cross section, pitch length & size A-28, including disconnection and taking down of ‘V’ belts from motors complete all as specified and directed, Make : Fenner / Hilton. (a) Cross section 13 x 08 mm & pitch length 740 mm of size A-28.
(b) V-belt of size B-66 for hot water blower at Bison APTT
(c)V-belt of size B-72 for AC Palnt AHU blower at WWR
(d)V-belt B –82 for hot water blower at Mig Bison APTT
(e)V-belt B –60 for hot water blower at Kopyo Lab
Dismantling and taking out existing unserviceable pressure gauge of any description and in any position and supplying & fixing water pressure gauge of range 0 – 100 PSI, 100mm dia, complete all as specified & directed. Make : Fiebig / ACCEL/ Superior.
S&F suction valve for compressor including disconnecting & taking down old existing unserviceable suction valve of any description and in any position complete all as specified and directed:- (a) Model 050405 of make VOLTAS
S&F high pressure discharge valve for compressor including disconnecting & taking down old existing unserviceable suction valve of any description and in any position complete all as specified and directed :- (a) Model 050405 of make VOLTAS.
Disconnecting & dismantling of existing unserviceable cooling tower, FRP type, 60 TR Capacity , of any description & in ` any position complete including dismantling all old connected parts/items like motor, FRP casing FRP Basin PVC filing, MS/GI Pipe line, sluice valve, stop valve, steel structure frame etc, servicing /overhauling, cleaning, oiling/greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling the cooling towers and connected parts/items fixed in position for connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge. Note: - (i) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (ii) The rates for above item are deemed to include replacement of necessary unserviceable screws/ nuts/bots /washers/ packing etc.
Supply only PVC netting heavy duty for cooling tower as per sample approved by GE.
Taking down existing unserviceable corroded/rusted pot strainer from outlet pipe line of cooling tower and supplying and fixing new pot strainer along with filter mesh including welding of 02 Nos MS flange on both ends, nuts, bolts, washers, rubber gasket etc .complete of 50 mm size all as directed by Engineer in Charge.
Supply only PVC filling blocks of size 600mmx300mmx150mm suitable for cooling tower of Make: - MIHIR/SUVIDHA/ AVIRAT
Dismantling and taking down existing micro filters of sizes 5 to 10 micron from AHU duct plenum for checking the serviceability of filter element, servicing and cleaning of filter elements, replacement of existing unserviceable filters and fixing the serviceable filters in position including preparation of the surfaces of MS cover of filters and applying one coat of synthetic enameled paint of approved colour complete all as specified & directed by Engineer-in-Charge. Note: The quoted rates of the contractor includes for fixing the serviceable filter elements in position and replacement of unserviceable filters with new filters. The new replaced filters shall be measured and paid for separately under appropriate item of Sch `A’ “as `supply only”
Supply only the following filters suitable for Air handling units of air conditioning plants all as directed by the Engineer-in-Charge (Make : Tenacity Filters Pvt Ltd. / Ravi Industries or equivalent make as approved by the GE) Note (i) Cost element of removing unserviceable filters fixing and testing of the new filters is deemed to be included in the rates quoted by the contractor under respective Sch ‘A’ (ii) Contractor shall have no claim on account of variation of quantities of these items/non execution of any of the above items and contractor shall be paid for at as quoted rates only for the parts actually replaced. (a) Micro ‘V’ air filter nylon/fabric fibre, media of capacity 5 micron, 98% efficiency of size 550mm x 550mm x 300mm deep.
Supply only gland bolts made out of high carbon forged steel complete with nuts , bolts & washers suitable for any capacity of pumps of any make/model complete all as specified & directed.
Supply and fixing strip heater 3 KW, 230 volts fin type Make : Daspas or equivalent make as approved by the GE
Dismantling , taking down existing worn out and rusted unserviceable duct including its insulation, supports etc complete.
M & L for fabriction of Supply air ducting made out of GI sheet of thickness 22 SWG (Zinc coating 120 gm/Sqm) and fabricated as per IS-655 including necessary bend and locking arrangements complete.
Disconnecting, dismantling & taking up/down AC electric motors of any description and in any position from existing foundation of compressor/blowers/pumps/ cooling tower strip opening and dismantling of motor for servicing /overhauling, cleaning oiling/greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling motors, ensuring proper alignment of the motor with existing compressor / pumps/blower/cooling tower, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities covered vide item 1.10 to 2.10:- (a) 0.50 HP to 1.5 HP single phase 50 Hz
(b) 7.5 HP Three phase 50 Hz
(c) 40 HP Three phase 50 Hz
Disconnecting, dismantling & taking up/down pump set and monoblock pump sets of AC plant of any description and in any position from existing foundation, strip opening and dismantling of Pumps for servicing/overhauling, cleaning oiling/ greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling the pumps ensuring proper alignment of pump, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 0.5 HP to 1.5 HP single phase 50 Hz
(b) 2.0 HP to 3.0 HP Three phase 50 Hz
(c) 7.5 HP HP Three phase 50 Hz
Notes for Schedule `A' srl item no. 21 & 22
(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under respective item of overhauling and servicing mentioned hare in before.
(ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding.
(iii) The rates for above items are deemed to include for transportation to & from of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bots/washers/ packing etc with new one
(iv) Re-metaling of side cover of motor and machinery, polishing for housing of bearing all as required at site for smooth and noiseless movement of rotor impeller shall be measured and paid for separately under appropriate item of Schedule `A’.
(v) Re-metaling to pump shaft, polishing and grinding and making to standard size to match with GM Bushes / Neck ring shall be measured and paid separately under appropriate item of Sch`A’
Supply only ball Bearing/Roller Bearing of the following size and make complete all specified and directed by the Engineer-in-Charge.(Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective Sch ‘A’
(a) 2.0 HP to 3.0 HP Three phase 50 Hz
(b) 7.5 HP HP Three phase 50 Hz
Supply only gun metal bushes suitable for following capacity of pumps of any make/model :- (a) 02 to 05 HP Pump
(b) 7.5 to 12.5 HP Pump
Supply only of CI star coupling L – 190 for pump and Motor or as approved by GE. Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective Sch ‘A’ item
Supply only pump impeller suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 2.0 HP to 3.0 HP Three phase 50 Hz
(c) 7.5 HP HP Three phase 50 Hz
Disconnecting and taking down existing unserviceable terminal plate of any description and in any position supply and fixing terminal plate, 3 phase, six wire, bakelite, star delta connection as required at site with brass studs, two nuts and two washer complete all as specified and directed for the following capacity of motors : - (a) 1 HP to 3 HP
(b) 5 HP to 10 HP
Disconnecting and taking down existing unserviceable condenser & supply and fixing new condenser, 10 mfd, 400 volt grade suitable for single phase motor complete all as specified and directed.
Re-metaling and re-fabrication of bearing housing side cover to suitable shape & size, both side and taking out broken/rusted alen key bolt by drilling and gas cutting including S&F new (Set of 4) Alen key bolt as per existing size complete all as specified and directed for following capacity of motor :- (a) 5/7.5 HP, 3 Phase (any make)
(Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective Sch ‘A’ items here-in-before
Repair to starter body by Re-metaling brazing & turning on lath Machine both side with matching of bearing housing cover complete all as specified and directed for following capacity of motor:- (a) 5/7.5 HP, 3 Phase
Re-metaling of Pump shaft/motor shaft of any description & in any position, making to standard shape & size grinding & polishing to match with existing system complete all as specified & directed for the following capacity of motor :- (a) 1 HP to 3 HP
(b) 5 HP to 10 HP
Dismantling and taking down/removing of damaged fan blades of any description and in any position from electric motors all as directed and Supply and fixing Fan blades fabricated to shape and size of Zink Aluminum cast alloy as per sample for electric motor with key and key grove complete all as directed for the following capacity motors :- (a) 1 to 3 HP
S&F in repair including testing of bimetalic thermal over load relay for DOL/star delta starter415 volts complete all as specified and directed the following capacity of any make of pump and motor :- (a) Suitable for 0.5 HP to 2 HP
(b) Suitable for 7.5HP
S&F including testing power contactor 3 pole with 2NO +2NC auxilary contacts for AC circuit with AC coil voltage 220 volts grade 50 HZ having suitable for following pump motor starter 415 Volts rating complete all as specified and directed (a) Suitable for 5 HP to 7.5 HP
S&F in repair including testing of power contractor 3 pole with 01N +01NC auxillary contact for AC circuit with AC coil voltage 220 grade 50 HZ having following current rating complete all as specified and directed (a) Suitable for 5HP to 7.5HP
S&F in repair single phase preventor auxilary volts 415 volts suitable for 3 phase AC supply complete all as specified and directed Make Minilec type VSP-D1 or equivalent of other specified makes,
Disconnecting and removing existing unserviceable interconnecting wiring and connectors of electric control panels of any description and in any position after through checking and inspection at site and material & labour for repairs of electric control panel & its interlocking system with using FRLS PVC insulated and unsheathed standard copper conductor cable single core 1.5 sqmm size 1100 volts grade cable for making functional controls of the compressor, chilled water pump, condesor water pump air handling unit, cooling tower fan LP/HP/Differential oil, pressure switch, solenoid valve capacity control valve , thermostat, humidistate, heater,auxiliary contactor, push button, indicator, amps meter, volt meter complete as required at site for funtioning of central Ac plant,DX type/chilled water type complete all as specified and directed.
S&F in repair including testing of electronic timer, time range from 3 seconds to 120 seconds suitable for 240/415 volts 50 HZ complete all as specified and directed
S&F in repair including testing of DOL motor starter 7.5 HP capacity, 415 Volts, 3 phase, 50 Hz AC supply, in sheet steel enclosure three phase with maximum relay range of 9-15A fixed on wall with and including teak wood board of appropriate size fixed with suitable MS nut bolts/screws complete all as specified and directed.
Disconnecting & taking out corroded / unserviceable existing condenser water pipe line of any description and in any size and supply & fixing galvanized iron pipe medium grade for water pipe line with and including all fittings & fixtures of the following sizes complete all as specified and directed. (a) 32mm bore pipe line.
(b) 40mm bore pipe line.
(c) 50mm bore pipe line.
(d) 80mm bore pipe line.
S&F in repair including testing LED indicator 22.5mm suitable for operating at 240/220 volts complete all as specified and directed.
S&F in repair including testing of spare coil 220 volts suitable for following contractor complete all as specified and directed (a) For power contactor 3 pole upto 2 to 5 Amps
S&F in repair including testing spare contact kit without coil suitable for following power contactor complete all as specified and directed (a) For power contactor 3 pole upto 2 to 5 Amps
(b) For power contactor 3 pole 5 Amps
Maintenance once in two months as directed by Engineer-in-charge package type AC plant3x11 TR+ 2x7.5 TR (05 Units) installed at KOPYO Lab Make Voltas, (i) One unit comprising of following:- (a) Condensor - 02 Nos (b) Compressor - 02 Nos (c) Blowers Motor - 01 Nos (d) Evaporator - 02 nos (e) Micro processer control panel - 01 Nos Note :- (i) Maintenance includes ;- (a) Cleaning of all components and parts of plant, (b) Greasing of all components and parts of plant (c) Tightening of all nuts, bolts and washers etc (d) Cleaning of all filters (e) Oiling of all components and parts of plant (f) Replacement of spares as required which will be measured and paid separately under respective item as Supply only (ii) No extra cost will be paid to the contractor for T&P and trade as required. (iii) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (iv) The setting of design parameter of air conditioning in microprocessor control panel & maint of soft ware is include in this rate.
Maintenance once in two months as directed by Engineer-in-charge package type AC plant3x7.5 TR (03 Units) installed at BISON APTT Make Voltas, (i) One unit comprising of following:- (a) Condensor - 02 Nos (b) Compressor - 02 Nos (c) Blowers Motor- 1 Nos (d) Evaporator- 02 nos (e) Micro processer control panel - 01 Nos Note :- (i) Maintence includes ;- (a) Cleaning of all components and parts of plant, (b) Greasing of all components and parts of plant (c) Tightening of all nuts, bolts and washers etc (d) Cleaning of all filters (e) Oiling of all components and parts of plant (f) Replacement of spares as required which will be measured and paid separately under respective item as Supply only (ii) No extra cost will be paid to the contractor for T&P and trade as required. (iii) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (iv) The setting of design parameter of air conditioning in microprocessor control panel & maint of soft ware is include in this rate.
Supply only for the 11 TR air cooled package type AC Plant Make :- Voltas (a) Microprocessor sensing panel (LCD) type
(b) Filter dryer
(c) Emerson thermostatic Exapn-vavle
(d) Compressor scroll type
(e) Motor suitable for blower
(f) Aluminium fan blade as per existing size
(g) fan motor of out door unit
Supply only for the 7.5 TR air cooled package type AC plant Voltas make :- (a) Filter dryer
(c) Emerson thermostatic Exapn-vavle
(d) Compressor scroll type
(e) Motor suitable for blower
(f) Aluminium fan blade as per existing size
(g) fan motor of out door unit
Maintenance once in two months as directed by Engineer-in-charge for 07 plants (SNCO Mess -02, Airmen Mess No 1- 02 Nos, Airmen Mess No 2- 01 Nos, Airmen Mess No 3 -01 Nos, and DSC Mess-01 Nos Note :- (i) Maintence includes ;- (a) Cleaning of all components and parts of plant, (b) Greasing of all components and parts of plant (c) Tightening of all nuts, bolts and washers etc (d) Cleaning of all filters (e) Oiling of all components and parts of plant (f) Replacement of spares as required which will be measured and paid separately under respective item as Supply only Note - (i) No extra cost will be paid to the contractor for T&P and trade as required. . (ii) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (iii) The setting of designe parameter is include in this rate.
Supply only following components for Hot Water Plant
(a) Fuel pump
(b) Ignation coil
(c) ignation coil rod
(d) Nozel
(e) Photo cell
(f) Solonoid vavle
(g) Contactor
(h) controller
(j) Thermostate
(k) sequance controller
Maintenance of Hot Air plant Diesel Operated with thermic fluid on monthly basis for 06 plants HQ -02, Crash Bay- 04 Note :- (i) Maintence includes ;- (a) Cleaning of all components and parts of plant, (b) Greasing of all components and parts of plant (c) Tightening of all nuts, bolts and washers etc (d) Cleaning of all filters (e) Oiling of all components and parts of plant (f) Replacement of spares as required which will be measured and paid separately under respective item as Supply only Note - (i) No extra cost will be paid to the contractor for T&P and trade as required. . (ii) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (iii) The setting of design parameter is include in this rate. (iv) Each Plant comprises of following :- (a) Aquatherm Hot water boiler 200000 kcal fully automatic model No AT 200W Make thermex Pvt (Stn HQ and Crash way) (b) Water cercular pump 5 HP Make- Kirloskar (c) Monoblock fuel pumping set 1 HP -03 Make- kirloskar (d) water circulating pump 3 HP -04 Make -Kirloskar (e) Air handling unit 9700 ,5700,3100 cum/hrs -02 Nos Make indoair (f) Hot storage tank 800 ltrs (g) Bulk fuel storage tank of 5 KL capacity-01 and fuel day tank 500 ltrs-01 No
Supply only following components for Hot Air Plant
(a) Fuel pump
(b) Igintion coil
(c) ignation coil rod
(d) Nosel
(e) Photo cell
(f) Solonoid vavle
(g) Contractor
(h) controller
(j) Thermostate
(k) sequance controller
(l) Thermic fluid
Maintenance of Hot Air plant electrically operated once in two months as directed by Engineer-in-charge- 02 plant(WSA - 02Nos) Note :- (i) Maintence includes ;- (a) Cleaning of all components and parts of plant, (b) Greasing of all components and parts of plant (c) Tightening of all nuts, bolts and washers etc (d) Cleaning of all filters (e) Oiling of all components and parts of plant (f) Replacement of spares as required which will be measured and paid separately under respective item as Supply only Note - (i) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (ii) The setting of designe parameter is include in this rate. (iii) No extra cost will be paid to the contractor for T&P and trade as required.
Supply Only following componenets of HotAir Plant
(a) Heating element 25 KW
(b) Thermostate
(c) Controller
(d) sub zero controller
(f) Contactor
(h) time delay
(j ) Over load relay
(k) MCCB 200 A
(l) MCB TP 100 A
Maintenance of Hot Air plant Diesel Operated with Hot Water once in two months- 01 plant SMC) Note :- (i) Maintence includes ;- (a) Cleaning of all components and parts of plant, (b) Greasing of all components and parts of plant (c) Tightening of all nuts, bolts and washers etc (d) Cleaning of all filters (e) Oiling of all components and parts of plant (f) Replacement of spares as required which will be measured and paid separately under respective item as Supply only Note - (i) No extra cost will be paid to the contractor for T&P and trade as required. . (ii) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under this item. (iii) The setting of designe parameter is include in this rate. (iv) Each Plant comprises of following :- (a) Aquatherm Hot water boiler 200000 kcal fully automatic model No AT 200W Make thermex Pvt (Stn HQ and Crash way) (b) Water cercular pump 5 HP Make- Kirloskar (c) Monoblock fuel pumping set 1 HP -03 Make- kirloskar (d) water circulating pump 3 HP -03 Make -Kirloskar (e) Air handling unit 9700 cum/hrs -01 Nos (f) Hot storage tank 800 ltrs (g) Bulk fuel storage tank of 5 KL capacity-01 and fuel day tank 500 ltrs-01 No
Supply components Only for HotAir Plant deisel operated with hot water
(a) Fuel pump
(b) Iginition coil
(c) Solonoid valve
(d) Sequence controller
(e) Fuel nosel
(f) Contractor
(g) Thermostat
(h) Photocell
(j) PCB controller
Servicing/maintenance of split type air conditioner of 1 to 2 ton cap any make any size which includes the following :- “(i)Unscrewing the front cover of internal unit at its location and cleaning of filter/servicing/cleaning the entire unit with electric blower and cleaning with colin or equivalent agent including testing and refixing complete all as directed and specified by Engineer-in Charge. ” Note :- (i) Spare parts any reqd shall be measuread and paid separetely as supply only . (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iii) All the serviced AC units shall be handed over on daily basis through proper documentation . (Iv) Penal charges @ Rs 500 per unit per day shall be charged for not following the schedule. (v) Thorough care / protection of PCB plate shall be taken to avoid any kind of damage while servicing/ cleaning or otherwise same will be repaired/replaced by contractor at his own cost . (vi) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost . (vii) Each service shall be measured and paid separetly as each job
Servicing/maintenance of window type Air conditioner of 1 to 2 ton cap any make any size which includes the following :- (i) Taking out the entire unit from the existing location wherever installed after unscrewing front cover, packing material, ply or any type of front cover whatever it may be. (ii) Servicing/cleaning the entire unit with elect blower and cleaning with Collin or equivalent agent. (iii) Testing and refixing complete all as directed Note :- (i) Spare parts any reqd shall be measuread and paid separetely as supply only . (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iii) All the serviced AC units shall be handed over on daily basis through proper documentation . (Iv) Penal charges @ Rs 500 per unit per day shall be charged for not following the schedule. (v) Thorough care / protection of PCB plate shall be taken to avoid any kind of damage while servicing/ cleaning or otherwise same will be repaired/replaced by contractor at his own cost . (vi) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost . (vii) Each service shall be measured and paid separetly as each job
Attending the daily complaints which includes checking electric circuit, tightning of loose electric connection including internal circuit of the AC, Refrigerator/ Deep Freezer and ensure the functioning complete all as specified and directed by Engineer-in-Charge Note :- (i) The complaint shall be handed over to contractor during working hours and same shall be attended on the same day (ii) The deployed tradesman shall have technical qualification in the field and necessary documentary proof shall be produced by the contractor (iii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing, etc (iv) For non adherance of complaints with in 24 Hrs penal charges @ Rs 500 per complaint per day shall be charged. (v) Spare parts any reqd shall be measuread and paid separetely as supply only .
Strip opening of sealed unit after unscrewing nuts, bolts, & taking down unserviceable sealed unit compressor from existing window type air conditioner /split type air conditioner of capacity 1.5 ton of any make and Supply and fixing new sealed unit compressor of existing type make Carrier/ Kirloskar/ LG/ Voltas/ Blue Star including cleaning the base plate and charging of refrigerant R-22/R-410 whichever required gas to obtain adequate cooling, complete all as specified and directed by EIC.
Strip opening of sealed unit after unscrewing nuts, bolts, & taking down unserviceable sealed unit compressor from existing window type air conditioner /split type air conditioner of capacity 2 ton of any make and Supply and fixing new sealed unit compressor of existing type make Carrier/ Kirloskar/ LG/ Voltas/ Blue Star including cleaning the base plate and charging of refrigerant R-22/R-410 whichever required gas to obtain adequate cooling, complete all as specified and directed by Engineer-in-Charge
Supply only starting relay LT 85002 single phase 240 volts AC, 50 Hz, 20 Amps complete all as specified and directed by Engineer-in-Charge, Make: Techno / Kirloskar
Supply only of AC contactor single phase 230 volt 50 Hz capacity 25 Amps rating double pole complete all as specified and directed by Engineer-in-Charge, Make: L&T/ BCH/ C&S
Supply only of AC contactor single phase 230 volt 50 Hz capacity 32 Amps rating double pole complete all as specified and directed by Engineer-in-Charge, Make: L&T/ BCH/ C&S
Supply only of AC contactor single phase 230 volt 50 Hz capacity 40 Amps rating double pole complete all as specified and directed by Engineer-in-Charge, Make: L&T/ BCH/ C&S
Supply only remote control hand set with required dry cell battery AAA size for existing window type air conditioner/ split type AC complete all as specified and directed by Engineer-in-Charge Make: LG/ Samsung/ Voltas/ Bluestar and of cap 1.5/2 ton
Suppy only 50 Mfd running capacitor of window type Air conditioner/ split type air conditioner complete all as specified and directed by EIC. Make: Sharda/ Asian/ Unistar/ Tesla/ Epcos
Supply only air filter made of Ric/ nylon suitable for window/split type Air Conditioner 1.5 TR/ 2TR capacity complete all as specified and directed by EIC. Make: AC Samsung/ LG/ Voltas/ Carrier
Supply only thermostatic switch single phase 230 volt 50 Hz suitable for fedder Lloyd/ Bluestar/ Voltas/ Carrier/ LG/ Samsung window type air conditioner complete all as specified and directed by Engineer-in-Charge, Make: Indofoss/ Danfoss
Supply only starting capacitor of capacity 80-100 Mfd in plastic container complete all as specified and directed by Engineer-in-Charge, Make: Sharda/ Asian/ Unistar/ Tesla/ Epcos
Supply only capacitor oil based 36 to 50 Mfd complete for window/split AC 1/1.5/2 TR cap complete all as specified and directed by Engineer-in-Charge Make: Sharda/ Asian/ Unista/ Tesla/ Epcos
Supply only aluminium blower fan with gun metal bush, screw complete all as specified and directed by Engineer-in-Charge
Supply only rubber coupling mounting for blower motor of window type and split type AC of make Carrier/ Voltas/ LG complete all as specified and directed by Engineer-in-Charge
Supply only 5/8” and 3/8” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and directed by Engineer-in-Charge
Supply only 1/2” and 1/4” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and directed by Engineer-in-Charge
Supply only swing motor for 1.5 TR /2 TR split AC indoor unit for any type and make complete all as specified and directed by Engineer-in-Charge Make: Carrier/ Voltas/Blue star
Supply only cooling coil motor 1/35 HP, three speed, single phase, 230 volt, 50 Hz suitable for split AC 1.5/ 2 ton complete all as specified and directed by Engineer-in-Charge Make: Carrier/ LG/ Blue star
Supply only PVC flexible pipe 15 mm dia for condensed water drain out complete all as specified and directed by Engineer-in-Charge
Supply only suction valve size 3/8" complete for 1.5/2 TR split AC complete all as specified and directed by Engineer-in-Charge, Make: BAP / TAK Cassel
supply only discharge valve size 1/2" complete for 1.5/2 TR split AC complete all as specified and directed by Engineer-in-Charge, Make: BAP / TAK Cassel
Carrying out pressure leak test by Nitrogen gas pressure for detecting the leakage in condensing unit, refrigerant pipe and repairing the leakage by welding or brazing, checking the leakage after repairing flushing out by nitrogen gas, vacummnation and charging of refrigerant gas R-22 into the system for 1.5/2 TR capacity split/window type AC including transporting & carrying Tools & Plants required at site complete all as specified and directed by Engineer-in-Charge Note: Refrigerrant gas R-22 will be measured and paid under relevant item
Supplying and charging (Top up) the AC unit of window/ split of cap 1.5/2 TR with refrigant gas R22 in required quantity for desired cooling complete all as specified and directed by EIC. Note :- For Ser Item No 59 to 79 :- Labour charges for fixing of the items deemed to be included in the sch A item No 54 and 55.
Taking down of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing indoor unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and directed by EIC. Make: Voltas/Bluestar/Carrier
Taking down of defective indoor unit of 2 TR capacity split type AC and supply & fixing indoor unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and directed by EIC. Make: Voltas/Bluestar/Carrier
Taking down of split type AC 1.5/2 Ton complete mounting, fitting indoor & outdoor units, duly restoring the gas and refixing in new location complete all as specified and directed by EIC. Note: Extra refrigerant pipe line, electrical accessories, refrigerant where required will be measured and paid for separately
Disconnecting electric connection from defective blower motor and taking out from window type/ split AC outdoor unit capacity 1.5/2 TR of existing make, dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire including insulation, varnishing, greasing, testing complete and refixing the same and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge
Taking out of defective wiring of indoor/ outdoor unit, PCB, visual eye damp plates, unserviceable cordless electronic remote control and fixing the new wiring, cordless electronic remote control, PCB, visual eye damp plate in place of damaged items of split AC of capacity 1.5 TR/ 2TR including matching the existing system complete all as specified and directed by Engineer-in-Charge, Make: Voltas/Blue Star/LG/Carrier
Servicing/ maint of Refrigerator 165 / 180 / 240 / 300 / 310 L, Deep freezer 100/300, which includes servicing/cleaning the entire unit with elect blower and testing and refixing complete all as specified and directed by Engineer-in-Charge Note: (i) Spare parts if required shall be measured and paid separetely as supply only (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iii) All the plants shall be handed over on daily basis through proper documentation (v) Penal charges @ 500 per plant per day shall be charged for not following the schedule (vi) Thorough care/ protection of elect circuit plate shall be kept to avoid any kind of damage while servicing/ cleaning if otherwise same shall be repaired by contractor at his own cost (viii) Each service shall be measured and paid separetly as each job
Taking down old unserviceble compressor of any make/model from deep freezer and supply and fixing new sealed compressor in place of old compressor, replacing liquid line filter and capillary tube suitable for refrigrant with necessary brazing work, including charging of refrigerant R 22/R 134 to obtain adequate cooling complete all as specified and directed by Engineer-in-Charge Make: Blue Star/LG/Kirloskar
Taking down old unserviceble compressor of any make/model from refrigerator of capacity 165 / 180 / 240 / 300 / 310 L and supply and fixing new sealed compressor of same make in place of old compressor, replacing liquid line filter and capillary tube suitable for refrigrant with necessary brazing work, including charging of refrigerant R 22/R 134 to obtain adequate cooling complete all as specified and directed by Engineer-in-Charge.
Supply only door gasket suitable for 300/625 ltr deep freezer doors complete all as specified and directed by Engineer-in-Charge
Condensing coil for refrigerator 165L capacity, in repairs, including disconnecting condensing coil from refrigerator, Nitrogen Pressure testing and flushing out the system and charging of refrigerant gas up to required cooling level complete all as specified and directed by EIC.
Condensing coil for refrigerator 286/300 L capacity, in repairs, including disconnecting condensing coil from refrigerator, Nitrogen pressure testing and flushing out the system and charging of refrigerant gas up to required cooling level complete all as specified & directed by EIC.
Supply only starting relay for refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge
Supply only over load protector for refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge
Supply only thermostat defrost type ISI marked for refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge
Supply only in side freezer door for refrigerator of capacity 286/300 L complete all as specified and directed by Engineer-in-Charge
Supply only defrost tray for refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge
Supply only gas filter flair type ¾” x ½” flare for refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge
Copper capillary for refrigerator of any capacity, in repairs, complete all as specified and directed by Engineer-in-Charge
Supply only starting relay ISI marked for deep freezer of capacity upto 625 L complete all as specified and directed by Engineer-in-Charge
Supply only over load protector ISI marked for deep freezer of capacity upto 625 L complete all as specified and directed by Engineer-in-Charge
Supply only thermostat ISI marked for deep freezer of capacity upto 625 L complete all as specified and directed by Engineer-in-Charge
Supply only running capacitor 36 mfd ISI marked for deep freezer of capacity upto 625 L complete all as specified and directed by EIC. Make: Sharda/ Asian/ Unistar/ Tesla/ Epcos
Supply only running capacitor 60-80 mfd ISI marked for deep freezer of capacity upto 625 L complete all as specified and directed by EIC. Make: Sharda/ Asian/ Unistar/ Tesla/ Epcos Note :- For Ser Item No 91 to 102 :- Labour charges for fixing of the items deemed to be included in the sch A item No 89 and 90.
Supply & fixing in repairs top plug 5 Amp complete all as specified and directed by EIC.
Supply & fixing in repairs top plug 15 Amp complete all as specified and directed by EIC.
Supply & fixing drain pipe 25mm medium grade PVC complete all as specified and directed by EIC.
Supply & fixing bulb suitable for any make refrigerator and deep freezer complete all as specified and directed by Engineer-in-Charge
Supply and charging gas R-134 for top up for regrigerator of any make and capacity complete all as specified and directed by Engineer-in-Charge
Supply and charging gas R-22 for top up for deep regrigerator of any make and capacity complete all as specified and directed by Engineer-in-Charge. .
Strip opening of voltage stablizers of capacity upto 5 KVA after unscrewing nut, bolts, screw etc, of any make and any type for repairing of loose wire/connections including undertaking necessary repairs, including reassembling, testing complete all as specified and directed by Engineer-in-Charge
Supply & fixing Transformer copper wound complete with terminal plate 3 step ± up and down, single phase 230V nominal operating voltage range 180V to 280V for the following capacity of voltage stabilizers complete all as specified and directed by Engineer-in-Charge
2/3 KVA capacity
4/5 KVA capacity
Supply & fixing Standard PCB board suitable for the following capacity of voltage stabilizers, 230V AC stabilizer of Make V Guard/ AE complete all as specified and directed by Engineer-in-Charge
2/3 KVA capacity
4/5 KVA capacity
Supply & fixing Contactor Single phase 230V CTR, 25A, type MR 11W Cat No CS94176 of L&T or equivalent suitable for upto 5 KVA voltage stabilizer of make AE/V Guard/ Ranutrol/ ABB/ Legrand/ L&T/ BCH complete all as specified and directed by Engineer-in-Charge
Supply & fixing Reversible valve for split AC 1.5TR for effective functioning in heating mode to achieve desired room condition, in repairs, complete all as specified and directed by Engineer-in-Charge
Supply & fixing Reversible valve for split AC 2TR for effective functioning in heating mode to achieve desired room condition, in repairs, complete all as specified and directed by Engineer-in-Charge
Supply & fixing Metal clad plug & socket outlet 20 Amp, in repairs, complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB single pole ISI marked conforming to `C' series for incoming and outgoing conneciton of 6 to 32 Amps, 240 Volts, 10 kA breaking capacity complete all as specified and as directed by EIC.
Note for srl item no 1 to 116 : (i) All repair work shall be carried out only by authorised person qualified in the relevant trade (ii) Make of components replacement if not specifically mentioned in the relevant item same shall be of the existing make.
M/S Rather and Sons
M/S CHINAR BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .