PROVN OF EXHAUST FANS AND DG SET OF 160 KVA UNDER GE SAUGOR
2023_MES_610888_1
GE/SGR/TOK-37 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Saugor
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹69,000
Yes
30 Aug 2023
27 Jul 2023
18 Aug 2023
27 Jul 2023
16 Aug 2023
11 Aug 2023
27 Jul 2023 - 4 Aug 2023
Amount
M&L for one light point point controlled by one switch with 1.5 Sqmm PVC insulated FRLSH, Class 2 unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing caping/ conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
S&F switch piano type flush, single pole, one way, 5 Amp 230 Volt complete all as specified and directed.
S&F ceiling rose, surface backlit, 63.5x48 mm three terminal complete all as specified and directed.
S&F exhaust fan, metal body AC single Phase. 230V of size 300MM sweep with 900 RPM blades, and frame and louvers including making hole in stone/brick masonry and making good to match the existing surface complete all as specified and directed.
S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250MM including making hole in stone/brick masonry and making good to match the existing surface complete all as specified and directed.
Supply and installation of Accoustic Enclosed diesel engine driven generating set in incl minimum OF 248 BHP / 1500 RPM water cooled multi cylinder and coupled with 160 KVA /126 KW 415 Volt 0.8 P.F ( Lag ) 50 Hz AC alternator, mounted on a common base frame with Safeties(LLOP &HWT) along with all std accessories i.e. fuel tank,floor mounted standard electric control panel, Battery(Charged) inclusive of one set of Anti Vibrration Pads(AVM) with leads exhaust silencer as per std scope of supply , AMF Control panel type 415 Volts 3 phae 4 wire complete relay panel for noise free compartement (acoustic enclosure ) housing all as directed by Engineer-In-Charge including following accessories for 160 KVA DG Set:-
Diesel Engine - The engine shall be vertical multi cylinder four stroke 1500 RPM water cooled with water pump assembly battery charging alternator of suitable instrument panel, in built governor starting battery heavy duty with leads (as recommended by the manufacturer) suitable size and length of exhaust pipe with necessary cladding materials,exhaust coupling inside acoustic enclosure / canopy,silencer and exhaust pipe above canopy all as specified by OEM and all other standard fittnig fixtures all as per OEM specification complete as per ISO 8528, BS 5514 / ISO 3046 & suitable BHP for the generator,(BHP not less than 299 BHP) all as directed by Engineer-In-Charge.
AC Alternator : The AC alternator (Generator) shall be designed for an out put of 160 KVA / 126 KW,50 HZ at full load for continuous rating & 10 % for over load for one hour at 0.8 ( lag ) PF confirming to BS - 5000 part 99/IS 4722 including self excited and self regulating screen protected ,standard panel with all accessories cable terminal box suitable size of glands earth terminal etc. complete all as per OEM specifications all as directed by Engineer-In-Charge.
Fuel (Services) Tank :- The fuel tank shall be built in type of capacity to run minimun as 12 hours on full load and shall include fuel level indicator fuel piping internally with necessary piping as recommended by the manufacturer from tank to engine and for over flow etc., complete all as specified and directed by Engr-in-Charge.
The tools as per the manufacturer's list shall be provided by the contractor alongwith the set at no extra cost.
Unit rate quoted shall deemed include the Control cable of suitable rating / capacity from DG set to AMF panel, Diesel lub oil, Coolant for Radiator etc for smooth functioning of DG Set during PH I & PH I I complete testing and initial full tank filling of Diesel Oil after PH I & PH I I testing,topping ofDiesel, Lub oil,Coolant for Radiator etc required for commissioning and testing of DG set .
Inverter 50 W capacity Suitable for LED bulbs with all accessories with necessary connections and wiring from DG Set Battery.inside the acoustic enclosure .
Supply, laying, jointing testing and commissioining cross linked polythylene (XLPE) insulated cable for working voltages of 1100 V PVC sheathed, armoured, 3 core with reduced neutral conductor 3.5 core nominal cross sectional area of main conductor 150sqmm stranded aluminium conductor ISI marked as per IS 7098(Parrt-I) 1988 including cavle glands, , lugs etc to suit the cable size and to be lain intrenches, fixed along pole, under floors, through GI pipe lain under floors/roads, through concealed GI pipe along wall etc complette all as specified and as directed
M&L for earthing 32mmx6mm complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below ground level) with the top edge of earth plate at depth not less than 1.5 m below ground level, connected to galvanised eath lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and as directed
M&L for On load change over switch 160 Amps , 415V, 4 Pole, 160 Amps with SS enclosure item Code No. IHCNFE0160 complete all as specified and directed
M&L for Synthetic rubber insulated mats 3.0 mm thick for electrical purpose as per IS 15652-2006 (Superseding IS 5424) suitable for electrical shock safety of sizes 2mx1m complete all as specified and directed
M/S Sai supplier
M/s VIKAS TRADERS
M/s JAYPEE ENTERPRISES
dipangashu barick and associates
M/s Prem Associates
Pioneer Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .