| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹22.5 L Quoted ₹24.3 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹24.8 L+₹53,533.95 (2.21%)Rejected-Finance WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹24.8 L+₹53,533.95 (2.21%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹26.6 L+₹2.3 L (9.68%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹26.6 L+₹2.3 L (9.68%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹31.6 L+₹7.3 L (30.0%)Rejected-Finance | ₹31.6 L+₹7.3 L (30.0%) | L4 | Rejected-Finance Rejected |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
23 Mar 2022, 6:00 pmClosed
GE AF Subroto Park
GE AF Subroto Park c o 56 APO
REPAIR/MAINT AND REPLACEMENT OF UNSV MS ERW PIPE, BUTTERFLY VALVE , SLUICE VALVE OTHER CONNECTED MISC ITEMS AT SUBROTO PARK IN THE AREA OF AGE E/M-II UNDER GE (AF) SUBROTO PARK
2022_MES_510313_1
GE/SP/ TOKEN-50/2021-22
Open Tender
Civil Works
Item Rate
270 days
Subroto Park Delhi
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF Subroto Park
₹66,000
Yes
4 Apr 2022
24 Feb 2022
25 Mar 2022
24 Feb 2022
23 Mar 2022
11 Mar 2022
Amount
Excavation in trenches in any type soil /rock n.exe 1.5 mtr wide and n.exe 1.5 mtr in depth for foundation laying of pipe etc n.exe 10 sqm on plan and n.exe 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-charge. NOTE : while removing the pipe line. Contractor shall replaced the broken tiles with new as per existing . The quoted rates including for necessary arrangement of all the materials / T&P / machinery. No extra cost shall be paid from department.
Returning filling in including spreading levelling watering and well ramming hard / dense soil in layers not.exc 25 cm each layers complete all as specified and as directed by Engineer-in-charge
Removal of excavated material & surplus soil to a distance n.exc 50 mtr and depositing where directed at a level not exe 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-charge
Taking up / taking out from trenches cast iron water mains including all fittings of 250mm bore including all fittings with spigot and socket end and lead joints including burning out joints and recovering lead complete all as specified and as directed by Engineer-in-charge
Taking up / taking out from trenches cast iron water mains including all fittings of 200mm bore including all fittings with spigot and socket end and lead joints including burning out joints and recovering lead complete all as specified and as directed by Engineer-in-charge
Taking up / taking out from trenches cast iron water mains including all fittings of 150mm bore including all fittings with spigot and socket end and lead joints including burning out joints and recovering lead complete all as specified and as directed by Engineer-in-charge
Taking up / taking out from trenches cast iron water mains including all fittings of 100mm bore including all fittings with spigot and socket end and lead joints including burning out joints and recovering lead complete all as specified and as directed by Engineer-in-charge
Cutting to cast iron pipes of 150mm bore before laying in position for insertion of new tees, branches, bend and new connection etc complete all as specified and as directed by Engineer-in-charge.
Cutting to cast iron pipes of 100mm bore before laying in position for insertion of new tees, branches, bend and new connection etc complete all as specified and as directed by Engineer-in-charge.
Supply and laying in replacement of unserviceable cast iron pipes size of 250mm bore including spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of unserviceable cast iron pipes size of 200mm bore including spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of unserviceable cast iron pipes size of 150mm bore including spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and as directed by Engineer-in-charge
Supply and laying in replacement of unserviceable cast iron pipes size of 100mm bore including spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and as directed by Engineer-in-charge
Supply and fixing and testing of CI fittings for spigot and socket pipes such as bends (any type radius and angle) tapers any type (straight, bend, increasing, descreasing or double socket etc), Tee piece single branch, 'Y' junction, double branch cross (all sockets or socket and spigot) collors, caps and plugs including dewatering suitable for pipes upto 200 to 250 mm bore complete all as specified and as directed by engr in charge. NOTE : Excavation earth work in any type of soil/Rock and jointing of pipes shall be measured and paid seperately.
All as per item No. 14 above but size of up to 200 mm complete all as specified and as directed by engr in charge.
All as per item No. 14 above but for flanged pipes size of 150 to 250 complete all as specified and as directed by engr in charge.
Supply and fixing in repair / replacement sluice valve cast iron with brass spindle PN-1.6 and fly nut flanged both ends and drilled for jointing wheel head type ISI marked conforming to IS 14846 including two flanged joints with nuts bolts and washers rubber insertion packing etc suitable for 250 mm bore pipe complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair / replacement sluice valve cast iron with brass spindle PN-1.6 and fly nut flanged both ends and drilled for jointing wheel head type ISI marked conforming to IS 14846 including two flanged joints with nuts bolts and washers rubber insertion packing etc suitable for 200 mm bore pipe complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair / replacement sluice valve cast iron with brass spindle PN-1.6 and fly nut flanged both ends and drilled for jointing wheel head type ISI marked conforming to IS 14846 including two flanged joints with nuts bolts and washers rubber insertion packing etc suitable for 150mm bore pipe complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair / replacement sluice valve cast iron with brass spindle PN-1.6 and fly nut flanged both ends and drilled for jointing wheel head type ISI marked conforming to IS 14846 including two flanged joints with nuts bolts and washers rubber insertion packing etc suitable for 100mm bore pipe complete all as specified and as directed by Engineer-in-charge.
M & L for run lead joint suitable for spigot & socket CI pipe 150 to 250 mm dia complete all as specified and as directed by Engineer-in-charge
M & L for rubber gasket joints for CI flanged pipes suitable for bore of pipe 150 to 250 mm bore complete all as specified and as directed by Engineer-in-charge
M & L for run lead joint suitable for spigot & socket CI pipe 100 mm dia complete all as specified and as directed by Engineer-in-charge
M & L for rubber gasket joints for CI flanged pipes suitable for bore of pipe 100 mm bore complete all as specified and as directed by Engineer-in-charge
Taking out existing GI pipe 80mm dia from trenches / walls / roof / floor etc including connection and cleaning for refixing or removal and making good to distrubed area (surface of walls / floor etc) complete all as specified and as directed by Engineer-in-charge.
Ditto-All as per item No 25 here-in before but of size 50mm dia
Ditto-All as per item No 25 here-in before but of size 40mm dia
Ditto-All as per item No 25 here-in before but of size 20/25mm dia
Supplying, laying or fixing in replacement, 20mm dia GI water tubing, medium grade, of size as shown below confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing and taking up / down existing unserviceable GI tubing with fittings / connections, carefully from trenches / celiling /walls/roofs etc
Ditto-All as per item No 29 here-in before but of size 25mm dia
Ditto-All as per item No 29 here-in before but of size 40mm dia
Ditto-All as per item No 29 here-in before but of size 50mm dia
Ditto-All as per item No 29 here-in before but of size 80mm dia
Supply, lay and testing in replacement of ERW MS pipes size of 150mm dia ISI marked grade 3.5 mm thick as per IS:3589 grade 330 suitable for welded joints and flanged joints including fabricating tailor made sepials as per site requirement including painting with two coats of anti corrosive paint complete all as specified . After bailing out water from existing semi UG sump with Appx 7 Mtr depth at pump house complete all as specified and directed by Engr-in-charge.
Supply, lay and testing in replacement of ERW MS pipes size of 100mm dia ISI marked grade 3.5 mm thick as per IS:3589 grade 330 suitable for welded joints and flanged joints including fabricating tailor made sepials as per site requirement includng painting with two coats of anti corrosive paint complete all as specifiedAfter bailing out water from existing semi UG sump with Appx 7 Mtr depth at pump house complete all as specified and directed by Engr-in-charge.
Supply and fix NRV valve of 150 mm dia IS:5312 cast iron body, PN1.6,provision of 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete all as directed.
Supply and fix NRV valve of 100 mm dia IS:5312 cast iron body, PN1.6,provision of 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete all as directed.
M&L for cutting MS pipe inserting tee , specials such as bend(any radius and angle), tail piece, collars, tees of any type etc suitable for flanged/socketed & spigot ends pipe and welding brazing of size 100 to 150 mm dia complete all as specified and as directed by Engr-in-charge.
M&L for Brick work with sub-class 'B' bricks straight on plan built in CM 1:4 for pipe line supports complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate built in CM for copping pipe liner support complete all as specified and as directed by Engineer-in-charge.
M&L for PCC as in foundation 1:2:4 type B-2 using 40mm graded stone aggregate built in cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work on concrete surfaces in 1:4 cement mortar for pillar supports complete all as specified and as directed by Engineer-in-charge.
Making good damaged surfaces of road to match the adjoining existing surfaces with using of paste premix bituminous 25mm thick polymer based material over WBM 75mm thick including rolling etc complete all as specified and as directed by Engineer-in-charge.
M&L for Construction of brick masonary valve pit of size 120cmx120cmx120cm (internal dimensions of chamber) depth to be reconed from the top of PCC in foundation to top of MS cover with MS sheet cover 3.15mm thick including frame of angle iron 40x40x6mm with locking arrangement including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in CM 1:6 15mm thick plastering in CM 1:4 (internal & external) and necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus spoil to a distance not exe 50 mtrs 150mm thick PCC 1:4:8 type D-2 for base and PCC copying 15mm thick 1:2:4 using 12mm graded aggregate complete all as specified and as directed by Engineer-in-charge.) for upto 150mm dia valve)
M&L for detecting and repairing leakage in CI/MS ERW pipe lines of size 100mm to 250mm bore, taking up unserviceable / serviceable CI/MS ERW water main with spigot and socket ends (including fittings) of any type/grade and joints from trenches and laying new CI/MS ERW pipe lines of size 100mm to 250 mm bore in trenches or placing on existing pillars /supports as directed to perform the following activities : (a) Excavation and earth work in soil/mud by using machinery/labour to suitable length (Appx 10 mtrs) and forming bund with excavated soil to avoid sea/row water entering into the working area including pumping/bailing out water by using portable deisel engine driven pump set.(b) Cutting of CI/MS ERW pipe of siz 100mm to 250mm00mm bore after thorough inspection for the damaged pipe line including disconnecting / dismantling.(c) Taking out CI/MS ERW pipe with CI/MS ERW specials after removing from joints/burning out joints and removing lead at both ends with the help of hydrolic crane other machinery and keeping aside for further disposal. (d) Cutting of new pipe into pieces as per requirement and laying using machinery. (e) Aligning the pipe line as per site condition, inserting the CI collar suitable for 100mm to 250 mm CI/MS ERW pipe.(f) Attending repair work within the minimum time frame/period as specified by Engr-in-Charge Notes (i) The unit rate is deemed to include cost of tools and plants and transportation required for attending the repair work. (ii) Supply only CI/MS ERW pipe shall be measured & paid seperately under relevant item of this schedule. (iii) Extra soil required for refilling/making bunds to prevent water entering into the work place shall be deemed to include in the unit rate. (iv) Specials/rubber or fiber /lead joints shall be measured and paid for seperately under relevant items of this schedule. (v) Old unsv CI/MS ERW pipes, fittings, lead, nuts bolts, washer, gaskets etc shall become contractors property and necessary recovery as per schedule of credit shall be deducted from contractor.
M&L for attending of water supply complaints for any leakage/blockage in GI pipe lines of size 20mm/25mm bore taking up serviceable/unserviceable GI water pipe lines all fittings/fixtures from trench including supply and laying GI tubing 20mm/25mm bore up to 1 mtr length (max) including necesssary cutting, threading and replacement of unserviceable GI fittings such as GI socket /Nipple/union socket / Tee /reducer etc. of size 20mm/25mm including necessary excavation and earth work up to 1 mtr length to repair the leakage / clearing the blockage in the pipe line and testing on completion on ground/wall/floor/roof of the bldg . (GI fittings shall be measured & paid seperately )
Ditto-All as per item No 46 here-in before but of size 40mm /50mm bore GI pipe line
Ditto- All as per item No 46 here-in before but of size 80mm /100mm bore GI pipe line
Cleaning of service tanks installed on roofs of multistoryed buildings at various places by emptying the tanks, removing scale, dirt and all other foreign materials deposited inside nipples, on side of walls and bottom of the tanks by scrapping and brushing with wire brush , and pressure pump, cleaning with bleaching powder slurry and allowed to dry and then washing the tank with fresh water, Checking and removing Airlock if any on next day after cleaning of the tank, cleaning of vegetation, etc, on surrounding RCC slab where the tank is resting and writing on the tank the date of cleaning, capacity of tank, etc, with synthetic enamel paint of 10 cm high and 6 cm width letters in white color, over a black background of size 450mm x 300mm complete all as specified and directed for the service tanks of capacity as shown below :- (a) Service Tanks of capacity exc 500 Ltrs and not exc 750 Ltrs
(b) Service Tanks of capacity exc 750 Ltrs and not exc 1000 Ltrs
(c) Service Tanks of capacity exc 1000 Ltrs and not exc 2000 Ltrs
(d) Service Tanks of capacity exc 2000 Ltrs and not exc 5000 Ltrs
S&F in replacement cable PVC insulated sheathed, unarmoured, flat submersible water proof with stranded copper conductor 1100 V grade of size 3 core 4 Sq mm.complete all as specified and directed by Engr-in-charge.
S&F in repair PVC copper stranded conductor cable size 1.5 Sqmm multi stranded single core 1100 volt grade complete all as specified and directed by Engr-in-charge.
S&F in repair PVC copper stranded conductor cable size 2.5 Sqmm multi stranded single core 1100 volt grade
S&F in repair PVC copper stranded conductor cable size 4 Sqmm multi stranded single core 1100 volt grade
S&F in repair PVC copper stranded conductor cable size 6 Sqmm multi stranded single core 1100 volt grade
S&F in repair PVC copper stranded conductor cable size 10 Sqmm multi stranded single core 1100 volt grade
S&F in repair PVC copper stranded conductor cable size 16 Sqmm multi stranded single core 1100 volt grade
S&F in repair PVC flat sheathed submersible cable copper conductor of size 2.5 sqmm 3 core,1100 volt grade
S&F in repair PVC flat sheathed submersible cable copper conductor of size 4.0 sqmm 3 core,1100 volt grade
S&F in repair PVC flat sheathed submersible cable copper conductor of size 6.0 sqmm 3 core,1100 volt grade.
S&F in repair PVC flat sheathed submersible cable copper conductor of size 10.0 sqmm 3 core,1100 volt grade.
Supply & fix in replacement of MCCB 200 amps 4/3 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.
Supply & fix in replacement of MCCB 100 amps 4/3 pole 25 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.
Supply & fix in replacement of MCCB160 amps 4/3 pole 25 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.
Supply & fix in replacement of MCCB 63 amps 4/3 pole 25 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.
Supply & fix in replacement of MCCB 400 amps 4 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of MCCB 250 amps 4/3 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 50 to 110
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 40 to 45
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 25 to 32
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX upto 18.
Supply and fix in replacement PVC water tank cylendrical shape 3 layer of capacity 5000 LTRS complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement PVC water tank cylendrical shape 3 layer of capacity 2000 LTRS complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement PVC water tank cylendrical shape 3 layer of capacity 1000 LTRS complete all as specified and directed by Engr-in-charge.
M & L for Charges for attending and rectifying the Door sensor minor complaints (control panels, motor and all electrical complaints) as and when required for smooth operation of Door sensor as when required to be replace unsv following spare parts after replacement testing shall be carried out as directed by Engineer-in-charge Note :- Spare parts shall be measured and paid separately
Supply and fix in replacement of Radar XL-C 4102 A for door sensor for one door including taking down unsv parts and fixing new parts in same position without damaged other items all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of control unit assembly XL-C 4106 for door sensor for one/two door including taking down unsv parts and fixing new parts in same position without damaged other items all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Motor assembly for 4100 of XL-C 4107 for door sensor for one/two door including taking down unsv parts and fixing new parts in same position without damaged other items all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Torroidal transformer XL-C 4108 for door sensor for one door including taking down unsv parts and fixing new parts in same position without damaged other items all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Main roller assembly for 4100 of XL-C 4109 for door sensor for one door including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of counter roller assembly for 4100 of XL-C 4110 for door sensor for one door including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of encoder Cable 450mm XL-C 4111 for door sensor including taking down unsv parts and fixing new parts in same position without damaged other items with proper clamps and securing all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Five position prog switch XL-C 4112 for door sensor including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of light barrier for 4100 of XL-C 4113 for door sensor including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Timer belt, fixing accessaries of XL-C 4117 for door sensor including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Carrier head assembly of XL-C 4119 for door sensor including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply and fix in replacement of Floor guide for framed aluminium door for door sensor including taking down unsv parts and fixing new parts in same position without damaged other items with proper screwes and nut bolt all as specified and directed by Engr - In - Charge Make : Dorma / GEZE
Supply, Installing,testing and Commissioning in replacement of Ultrasonic Level Transmitter at Sump and overhead tank for measurement of water level installing at specific location with proper securing and finishing including necessary tools arrangement for fixing with following specification alla s pecified and directed by Engr-in-Charge:- Range : 0-8 meters Accuracy : 0.5 % minimum Supply Voltage : 24V DC Output : 4-20 mA , 0-10V DC Make: Nivelco / Siemens/Banner
Supply, Installing,Testing and Commissioning in replacement of Ultrasonic Level Transmitter at Sump and overhead tank for measurement of of water level installing at specific location with proper securing and finishing including necessary tools arrangement for fixing with following specification alla s pecified and directed by Engr-in-Charge:- Range : 0-3 meters Accuracy : 0.5 % minimum Supply Voltage : 24V DC Output : 4-20 mA , 0-10V DC Make: Nivelco / Siemens/Banner
Supply, Installation, testing and Commissioning in replacement of 150 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 431, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. The mounting shall be direct on valve type including necessary excavation, erth work, electrical and data cable connection upto required length and PCC all as specified and directed by Engr-in-Charge. (Butterfly valve shall be have following specification):-. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. In built CPU:- Quad-core 64-bit ARM Cortex A53 clocked at 1.2 GHz Inbuilt 4 USB 2 ports In built Base Ethernet Port In built Micro SD port for loading your operating system and storing data In built wireless LAN and Bluetooth Low Energy The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed. Make : UNIVERSAL SWITCH GEAR CONTROL /EMERSON/ROTORK/SD TORK
Supply, Installation, testing and Commissioning in replacement of 150 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 431, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. The mounting shall be direct on valve type. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. In built CPU:- Quad-core 64-bit ARM Cortex A53 clocked at 1.2 GHz Inbuilt 4 USB 2 ports In built Base Ethernet Port In built Micro SD port for loading your operating system and storing data In built wireless LAN and Bluetooth Low Energy The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 36 inches above ground level complete all as specified and directed. Make : UNIVERSAL SWITCH GEAR CONTROL /EMERSON/ROTORK/SD TORK
Supply, Installation, testing and Commissioning in replacement of 200 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 431, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. The mounting shall be direct on valve type including necessary excavation, erth work, electrical and data cable connection upto required length and PCC all as specified and directed by Engr-in-Charge. (Butterfly valve shall be have following specification):-. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. In built CPU:- Quad-core 64-bit ARM Cortex A53 clocked at 1.2 GHz Inbuilt 4 USB 2 ports In built Base Ethernet Port In built Micro SD port for loading your operating system and storing data In built wireless LAN and Bluetooth Low Energy The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed. Make : UNIVERSAL SWITCH GEAR CONTROL /EMERSON/ROTORK/SD TORK
SANWARIYA ENTERPRISES
J.P. Enterprises
PG CONSTRUCTION AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .