| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC AOC | |
| 2 | L2₹44.6 L+₹2.6 L (6.22%)Rejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹45.1 L+₹3.1 L (7.34%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Not L1 | |
| 4 | Rejected-Technical ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | - | Rejected-Technical Present residual work load in hand is more than Five times tendering limit as per NIT. Hence not recommended. |
| Sl No | Description | Qty | Unit | sapana enterprises L1 | Shree Ayyappa Engineering L3 | KRISHNA ENGINEERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and not exceeding 10 sqm on plan and getting out in soft/loose soil for laying of cables, etc. complete all as specified and as directed. | 129 | Cum | 400 ₹51,600 | 550 ₹70,950 | 100 ₹12,900 Lowest |
| 2.00 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in hard/soft soil complete all as specified and as directed. | 115 | Cum | 70 ₹8,050 | 100 ₹11,500 | 20 ₹2,300 Lowest |
| 3.00 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed. | 14 | Cum | 70 ₹980 | 100 ₹1,400 | 40 ₹560 Lowest |
| 4.00 | M&L for cutting existing road/hard standing not exceeding 45x50 cm in wide & depth getting out excavated material for laying GI tube, returning filling & well rammaing watering finish suraface 10 cm from top including provision of PCC 1:3:6 for repairing, including removal of surplus soil all as directed. | 4 | Cum | 4,700 ₹18,800 | 5,100 ₹20,400 | 200 ₹800 Lowest |
| 5.00 | M & L for PCC 1:3:6 in round/ square shape as per site requirement of thickness not less than 3" suitable for fixing of cast iron tank cover complete all as specified and directed. | 1 | Cum | 4,700 ₹4,700 | 5,100 ₹5,100 | 100 ₹100 Lowest |
| 6.00 | M&L for taking down existing 20 mm bore steel conduit tubing complete with all fittings, accessories and connections, including disconnecting from the existing system, removing from site, for Schedule of Credit, and making good disturbed surfaces as required to facilitate installation of new pipe line, complete all as specified and as directed. | 100 | RM | 15 ₹1,500 | 30 ₹3,000 | 10 ₹1,000 Lowest |
| 7.00 | Ditto all as per item No 6 above but 25 mm dia bore complete | 300 | RM | 25 ₹7,500 | 32 ₹9,600 | 10 ₹3,000 Lowest |
| 8.00 | Ditto all as per item No 6 above but 40 mm dia bore complete | 300 | RM | 25 ₹7,500 | 32 ₹9,600 | 10 ₹3,000 Lowest |
| 9.00 | Ditto all as per item No 6 above but 50 mm dia bore complete | 300 | RM | 25 ₹7,500 | 32 ₹9,600 | 10 ₹3,000 Lowest |
| 10.00 | Ditto all as per item No 6 above but 80 mm dia bore complete | 60 | RM | 25 ₹1,500 | 32 ₹1,920 | 10 ₹600 Lowest |
Tender Value
Refer Docs
EMD Value
₹90,500
Closing Date
16 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Mankhurd
GE (NW) Mankhurd
REPAIRS MAINT OF DEFECTIVE WS PUMPING LINE TO VARIOUS STATIC TANKS AT NAD, WED, NSD SEWRI AND OTHER MAINT WORKS IN THE AOR OF AGE EM UNDER GE (NW) MANKHURD
2026_MES_784377_2
8629/E8
Open Tender
Civil Works
Item Rate
270 days
Mankhurd
As per tender document
8 documents required · 8 mandatory
₹500
GE (NW) Mankhurd
₹90,500
Yes
23 Nov 2026
25 Sept 2026
19 Oct 2026
25 Sept 2026
16 Oct 2026
2 Oct 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and not exceeding 10 sqm on plan and getting out in soft/loose soil for laying of cables, etc. complete all as specified and as directed. | 129 | Cum | - | - |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in hard/soft soil complete all as specified and as directed. | 115 | Cum | - | - |
| 3 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed. | 14 | Cum | - | - |
| 4 | M&L for cutting existing road/hard standing not exceeding 45x50 cm in wide & depth getting out excavated material for laying GI tube, returning filling & well rammaing watering finish suraface 10 cm from top including provision of PCC 1:3:6 for repairing, including removal of surplus soil all as directed. | 4 | Cum | - | - |
| 5 | M & L for PCC 1:3:6 in round/ square shape as per site requirement of thickness not less than 3" suitable for fixing of cast iron tank cover complete all as specified and directed. | 1 | Cum | - | - |
| 6 | M&L for taking down existing 20 mm bore steel conduit tubing complete with all fittings, accessories and connections, including disconnecting from the existing system, removing from site, for Schedule of Credit, and making good disturbed surfaces as required to facilitate installation of new pipe line, complete all as specified and as directed. | 100 | RM | - | - |
| 7 | Ditto all as per item No 6 above but 25 mm dia bore complete | 300 | RM | - | - |
| 8 | Ditto all as per item No 6 above but 40 mm dia bore complete | 300 | RM | - | - |
| 9 | Ditto all as per item No 6 above but 50 mm dia bore complete | 300 | RM | - | - |
| 10 | Ditto all as per item No 6 above but 80 mm dia bore complete | 60 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_886997.xls
BOQ • 0.86 MB
8629General.pdf
Tender Documents • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .