GE I KANPUR
GE I KANPUR CARIAPPA ROAD KANPUR CANTT 208004
SPECIAL REPAIR TO HOSTEL CUM TRANSIT FACILITY IN DGQA COMPLEX AT CQA GS AND SPECIAL REPAIR TO SALVAGE SUB DEPOT ROAD INSIDE COD UNDER GE I KANPUR
2020_MES_365325_1
GE(I)/KAN/T-45 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Kanpur Cantt
Class D category a i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹71,000
Yes
23 Sept 2020
30 Jul 2020
29 Aug 2020
30 Jul 2020
27 Aug 2020
14 Aug 2020
60 days
Amount
BnR Schedule
Dismantling of brick work built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facing etc.complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
All as per item No 3 above but except bricks and using bricks obtained from dismantling of brick work against item no 2 above complete all as specified and directed by the Engineer-in-charge. Note: Serviceable bricks retrievd from serial item no 02 herein before shall be reused after proper cleaning.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings including tiles and paver blocks etc. not exceeding 15 cm thickness (above or below ground level) complete all as specified and directed.
M & L for 75 mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggt) as in plinth protection,path ramp etc finished surface even and fair without using extra cement complete all as specified and directed.
M & L for 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.50 mm graded stone aggt) as in flooring to receive tiles complete all as specified and directed.
M & L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M &L form work to soffits of suspended slabs flat such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished surface of concrete for supporting of slab complete all as specified and directed (Note : 1.Form work shall be steel and consist of ISMC-100 (channel) and steel probe jack type etc . 2. Spacing of ISMC 100 shall be atleast 450 mm in one direction and vertical probe shall be 1.0 meter spaced . 3. Formwork of slab is considered to support of the existing slab to remove the cracked/damaged brick wall and rebuilt brick wall in the same loction.
M&L form work to chajja incl.edges rough finished surfaces of concrete flat complete all as specified and directed
M&L RCC 1:1 1/2:3 type A-1 (20 mm graded stone aggregate) as in bend, lintel over 1.5mtr plinth beam/ bend etc complete all as specified and directed
Demolition of reinforced cement concrete as in roofs, floors (other than ground floor), beams,chhajjas and similar workcomplete all as specified and directed
M & L RCC 1:1 1/2:3 type A-1 (20 mm graded stone aggregate) as in chajja complete all as specified and directed
M & L PCC 1:4:8 type D-2 (40 mm graded stone aggregate) in foundation / bed concrete complete all as specified and directed
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds etc complete all as specified
M &L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius in half brick thick built in CM 1:4 complete all as specified and directed
Taking down cement plaster on brick or stone wall/ceiling etc including racking out joints hacking for key scrubbing down with water etc complete, all as directed by Engineer –in-charge.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface finished even and fair mixed with water proofing compound @3% by weight of cement or as per manufacturer instruction complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of concrete or brick work, on internal walls finished even and fair complete all as specified and directed.
M&L for applying two coats of white wall care putty on newly plastered or undecorated surface internal/external surface of building to prepare the surface smooth, to make the edges sharp and proper in alignment including rubbing with sand paper to achieve a smooth surface and sharp straight edges , and applying two coat of oil bound distemper over a coat of primer all as specified and directed.
M&L for applying two coat of cement based paint over one coat of primer on plastered/undecorated surfaces incl preparation of surface complete all as specified and directed.
M&L preparation of old surfaces and applying two coat of weather coat paint over a coat of primer complete all as specified and directed.
M&L preparation of surfaces and applying three coat of white wash on ceilling on new surface complete all as specified and directed.
S&F in repair Vitreous china suatting pan of Orrissa pattern size 580x440mm white with integral foot rest including P trap or S trap front and back inlet, PCC bedding 1:5:10 type E-2 using 40 mm graded brick aggregate complete all as directed. Make : Hindware/ Cera/ Parryware as approved by GE.
S&F in repair 10 ltrs capacity PVC low level valve less flushing cistern (white) syphonic action type with all fittings such as inlet ball valve, float, and handle 32 mm dia polythene high density flush pipe and connected to squat pattern.Make : Hindware/ Cera/ Parryware/ Prayag as approved by GE.
M&L for Cutting chases, pinning in. making good to facings for concealed water tubing n exc 10cm grith and making good with cement mortar 1:3 complete all as specified and directed.
Taking up or down 15 mm bore GI pipe and connections, from trenches/walls and removal from site, complete all as specified and directed.
Taking up or down 20 mm bore GI pipe and connections, from trenches/walls and removal from site, complete all as specified and directed.
S&F 15mm bore steel tubes medium grade galvanized with all fitting and fixed in concealed or open position complete to walls and ceiling or laid in floor complete and all as specified and directed. Make : TATA/Jindal/ Prakash Surya as approved by GE.
S&F 20mm bore steel tubes medium grade galvanized with all fitting and fixed in concealed or open position complete to walls and ceiling or laid in floor complete and all as specified and directed. Make : TATA/Jindal/ Prakash Surya as approved by GE.
S&F in repair vitreous china wash basin white flat back size 550x400mm including CP pillar cock 01 no, 15mm dia and 32 mm dia PVC waste pipe and but including cutting for and pinning in ends of brackets or erecting stand, waste pipe including brackets fixed in repairs complete all as specified and directed. Make of WHB : Hindware/ Cera/ Parryware , Make of Pillar tap : L&K/Prayag/Jaquar/Hindware as approved by GE.
S&F in repair 15 mm bore angle cock, cast copper alloy cromium plated, screwed down, high pressure, with capstan screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make : Hindware/ L&K / Plumber / Jaquar/Prayag/Marc as approved by GE.
S&F in repair 15mm bore PVC connection 450mm long heavy duty with brass fly nut and warsher complete and all as specified and directed
S&F in repair PVC waste pipe 32/40mm dia suitable for wash basin etc complete and all as specified and directed
S & F in repair 15mm bore stop valves,fancy type cast copper alloy chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make : Hindware/ L&K / Plumber / Jaquar/Prayag/Marc as approved by GE.
S&F in repair 15 mm dia bib tap fancy type CP cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe complete all as specified and directed. Make : Hindware/ L&K / Plumber / Jaquar/Prayag/Marc as approved by GE.
S&F in repair of sheet glass ordinary 3mm thick and glazing with oil putty/wooden beading in sqare n exc 0.5 Sqm each pane incl hacking out old broken glass (any description,size,thickness,quality) from wooden/metal frames complete all as specified and directed.
S&F in repair galvanized MS wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
S&F in repair 25mm dia fancy type Mild steel PVC coated curtain rod with fixing brackets, including of MS bracket fancy type and end caps fancy type complete as specified and directed
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) and clearing rubbish off the premise complete all as specified and directed.
M&L for glazed ceramic coloured tiles joint free 300x450x 7 to 8 mm thick on vertical surfaces such as skiting/dado set and jointed in neat cement slurry and pointed in colour cement to match the shade tile over and inclduing 10mm thick rendering in CM (1:4) complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
M&L for 7 to 8 mm thick non skid ceramic coloured tiles joint free (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm area as in floors etc; laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM ( 1:4 ) complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
Material and labour for light colour vitrified tiles min.10mm thick(square/ rectangular), light shade , area of each tiles not exceeding 0.36 sqm area, as in flooring set and jointed in neat cement slurry and pointed in coloured cement to match, .laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
All as per item no 44 above but dark colour vitrified tiles on dado/skirting over 10mm thick rendering in CM 1:4.
Taking down of chowkats or frame (without taking off shutters from the frame area n exc 1.5 Sqm each complete all as specified and directed.
Taking down of chowkats or frame (without taking off shutters from the frame area exc 1.5 Sqm but n exc 4.00 Sqm each complete all as specified and directed.
Taking down shutter of any description n.exc 1 sqm each complete all as directed by Engineer-in-Charge.
Taking down shutter of any description of area exc 1 Sqm but not exc 2 Sqm each complete all as specified and directed.
M&L 2nd class HW as in plain , solid, straight chowkhats and frames , wrought , framed , rebated on the solid, rounded or chamfered, put together with glue pinned joints complete all as specified and directed.
S & F of 30 mm thick flush shutters factory made, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F for 35 mm thick second class hardwood, factory made ,glazed and skeleton shutter, open rebated and prepare to received glass, gauge etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauge etc; size of member of shutter as specified in SSR Part-I Section 8 clause 8.24 (a) and fixed to chowkhats complete all as specified and directed.
Supply and Fixing 3mm thick Sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5 Sqm in each complete all as specified and directed.
S & F galvanized mild steel wire cloth 0.45 mm nominal dia of wire and avg width of apertare 1.18 mm fixed with tinned tacks or galvanized wire staples.
M&L for preparation of new surfaces of wood of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F of mild steel flat iron as in hold fasts etc all as specified, confirming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for plain cement concrete 1:2:4, type B-0 using 12.5 mm graded stone aggregate as in filling of hold fast complete all as specified and directed.
Supply and fix 100 mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws complete all as specified and directed.
Supply and fix 75 mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws complete all as specified and directed.
S&F 300 mm long aluminum anodized sliding door bolt with hasp and staple and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F 150mm long extruded aluminium alloy handle fabricated type complete all as specified and directed.
S&F 100mm long extruded aluminium alloy handle fabricated type complete all as specified and directed.
S&F of 150 mm long barrel tower bolt aluminum anodized of extruded section complete all as specified and directed.
S&F of 100 mm long barrel tower bolt aluminum anodized of extruded section complete all as specified and directed.
Supply & Fixing in repair towel rail 20mm dia, 60 cm long brass chromium plated with brackets complete all as specified and as directed.
S&F small fittings of IInd class HW as in door/window stops and the like including all necessary labours articles n.exc 200 cucm each complete all as specified and directed.
S&F 19/20mm thick Particle board, exterior grade prelaminated both sides with decorative choice lamination, fixed with nails/ screw screws to timber frame work including liping work teak wood beading 6mm thick as in CB shutter, writing table and bookshelf complete all as specified and directed.
S & F continuous piano hinges electro galvanised width of flaps when open in 30 mm complete all as specified and as directed.
Complete removal of existing treatment i.e. white wash ,colour wash ,distempering etc. of wall complete , applying two coats wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc. at any height upto single story building complete as per manufacturer's instructions and directed at site. Make- Birla / JK white and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.all as specified and directed.(Note: Rate for scaffolding shall deemed to be included in the quote rates.
Demolition and breaking up drain pipes (SGSW, AC or Reinforced concrete) set in cement mortar internal dia of pipe 100mm
Dismantling of cast iron drain pipes and fittings, jointed in cement mortar and taking out of trench required internal dia of pipe 100mm
M&L for PVC (SWR) floor trap (75mm dia of outlet), plain with grating including jointing with solvent cement
S&F in repair CP grating doom100 mm dia With waste hole of complete all as specified and directed.
S&F in repair for chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union
S&F 100mm bore cast iron soil waste and vent pipe (spun pipe) in any length with or without ears with cement joints fixed to walls/ceiling or laid in floor
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
.Dismantling water tanks Capacity of tank exc 250 & n. exc 500 ltrs and removing from site complete all as specified and as directed
S&F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size including Supplied and fixed 20mm dia pvc float valve assembly complete all as specified and directed. Make: Sintex/ Dhara/Tuff/ JS Polyplast as approved by GE(I).
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per RM of surface area complete all as specified and directed
Excavating in trenches, n. exc 1.5m wide and n exc 1.5m in depth for foundation etc or for shafts, wells, cesspits manholes pier holes etc n. exc 10 Sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed
Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified.
Removing excavated material (soils) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed
S&F 150mm bore reinforced concrete pipes, class NP-2, laid and jointed complete with collars complete all as specified and directed
M&L for preparation of old painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic Enamel paints complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel surfaces of any description not other wise described over 10 Cm width or girth and applying two coat of Synthetic Enamel paint complete all as specified and as directed.
M&L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc and applying two coats of cement base paint on wall including necessary material,labour,T&P,scaffolding as required at site complete all as specified and as directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
S&F Framed work such as grills, grating etc. with ends of bars shouldered and / or riveted or forget into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
M&L 75mm thick, PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified..
S&F for 30 mm thick second class hardwood, factory made ,glazed and skeleton shutter, open rebated and prepare to received glass, gauge etc divided into square with plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauge etc; size of member of shutter as specified in SSR Part-I Section 8 clause 8.24 (b) and fixed to chowkhats complete all as specified and directed.
En M Schedule
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendents, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty and applying colour / white wash finish complete all as specified and directed.
M&L for point wiring with PVC (FRLS) insulated and unsheathed cable 1.5 Sqmm (Nominal area) multi-stranded copper conductor single core with proper colour coding including PVC conduit medium grade of 25 mm dia concealed in walls and surface on ceiling with and including pressed steel concealed terminal boxes of appropriate size and top cover 3 mm thick of plastic laminated sheet ISI marked of desired colour of make : Hylam, painting terminal boxes inside and outside with a coat red oxidé primer complete with all accessories with and including 1.5 Sqmm PVC insulated and unsheathed green colour multi-stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed for the following points:- Note: Cutting chases in walls required for concealed conduit wiring shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. Make of cable : Finolex/Havells/Gloster/Grandlay, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
(a) One light / fan / bell / exhaust fan point controlled by one switch.
(c) One 3 Pin socket outlet 5 Amps on Independent board.
One light point controlled by one switch upto ceiling height and on surface at ceiling
One 3 Pin socket outlet 5 Amps on same board.
All as per item No. 98 here in before but for one power point, independent point with 2.5 Sqmm (Nominal area) FRLS, PVC insulated and unsheathed copper conductor multi-stranded single core cable including green colour earth wire of size 1.50 Sqmm FRLS, PVC insulated and unsheathed copper conductor multi stranded single core cable.
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall / floor or roof etc and applying putty complete all as specified and directed
M & L for sub main wiring with two single core 4 Sqmm copper conductor PVC insulated and unsheathed multi-stranded cable (FRLS) including PVC conduit medium grade of 25 mm dia, concealed in walls for sub main connection and 4 Sqmm PVC insulated and unsheathed multi-stranded green colour copper conductor cable (FRLS) as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/ Havells/ Gloster /Grandlay as approved by GE, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
M & L for sub main wiring with two single core 10 Sqmm copper conductor PVC insulated and unsheathed multi-stranded cable (FRLS) including PVC conduit medium grade of 25 mm dia, concealed in walls for sub main connection and 10 Sqmm PVC insulated and unsheathed multi-stranded green colour copper conductor cable (FRLS) as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/ Havells/ Gloster /Grandlay as approved by GE, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
S&F socket outlet flush type, 5 pin 6 Amps, 240 Volts complete all as specified and directed.
S&F Switch socket combination 5 pin 5 and 15 amps multipurpose 2 in 1 flush type 240 volts complete all as specified and directed.
S&F ceiling rose surface bakelite of three terminals 240 Volts complete all as specified and directed.
S & F of lamp holder insulated body with back plate suitable for dome batten / conduit fitting complete all as specified and directed.
S&F electronic regulator, socket size, step type humfree for ceiling fan of 1200/ 1400 mm sweep complete all as specified and directed. Make: applicable for item no 103 to 108 : CONA / SSK / LEADER / HAVELLS.
S&F in replacement of old light fitting with LED tube light fitting high efficiency aluminium linear batten 20/22 watt fixed on wall/ceiling complete with all accessories along with LED tube rod 20/22 watt and provision of three core flexible of 1.50 Sqmm copper conductor cable from ceiling rose to light fitting and other fixing arrangement as required at site complete all as specified and directed..Make:- Philips Smart Bright Cat Part No BN021C LED 20S PSU NW GR / Wipro TRIM LED LL20-281-XXX-65AL1 / Havells cat part no BS20WLED865SPCWH Note : Contractor will submit guarantee/warranty certificate from manufacturer.
Supply and fix in replacement of High power LED street light 60/65 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and electronic driver fixed on pole/wall along with service bracket as per sample, clamps as directed, nuts, bolts, and washers as directed incl electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated from junction box to street light by laying in bracket/ pipe/ pole complete all as spfd. Make : Havells cat part no ENDURAPEARLNEOSL60WLED757PASYTOPC / Bajaj cat part no BRTFG 60W LED V3 / Wipro Cat part No LR02-671-XXX-57-G2/ C&S cat part no LTESST60WLED/LS /Philips cat part no BRP062 LED 68 CW SLC S1 PSU/CG NEXUS NEO cat part no LSTP-60-CDL-M as approved by GE.
S & F in repair of sheet metal enclosure factory made, TPN DB 4 way ,MCB Metallic modular distribution board (Vertical DB), 415 Volts, including 1 x MCCB 100 A, 3 pole, 16 KA as incomer, MCB SP (5-32A) - 12 Nos as outgoing with shrouded neutral bar & pan assembly with suitable flexible connecting link with neutral and earth bus bar having IP-43 protection and double metal door concealed / flush to wall surface including making connections with thimbles as required complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells (Note : MCB DB & MCCB / MCB any type should be same make) (ii) The MCCB and MCBs shall be measured and paid separately under respective items of CA
S & F in repair of sheet metal enclosure factory fabricated for MCB distribution board Single pole and neutral 240 Volts, 8 way with neutral and earth bus bar having IP-42 protection and double metal door concealed / flush to wall surface including making connections with thimbles as required complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells
S & F in repair of sheet metal enclosure factory fabricated for MCB distribution board Single pole and neutral 240 Volts, 4 way with neutral and earth bus bar having IP-42 protection and double metal door concealed / flush to wall surface including making connections with thimbles as required complete all as specified and directed. Make : Legrand / C&S/ L&T / Indo Asian/ABB.
S & F in repair MCCB 3 pole 415 Volts 3 phase 100 Amp 16 KA, thermal magnetic release complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells
S & F in repair MCB SPN 63 Amp 10 KA 240 V complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells
S & F in repair MCB SPN 40 Amp 10 KA 240 V complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells
S & F in repair MCB SP 6 to 32 Amp 10 KA 240 V complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells
M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below the ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washers of galvanised or steel all as specified or shown in electrical plate of SSR (Part-l) including necessary excavation, earth work, GI pipe 15 mm dia light grade for protection of galvanised iron earthing wire, GI pipe 20 mm dia light grade watering pipe etc. including concrete chamber of PCC 1:2:4 type B-2 (using 40mm graded stone aggregate), copping in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), internal surface of concrete chamber shall be plastered with 12 mm thick cement mortar 1:4 and 50 mm thick RCC cover in pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8 mm dia1or bar @ 80 mm c/c both ways and charcoal dust, common salt etc. including testing after completion complete all as specified and directed.
S & F in repair MCCB 4 pole 415 Volts 3 phase 200 Amp 35 KA thermal magnetic release complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/ Havells
Supply and fix single pole and neutral enclosue with a top pin and earth plug and socket complete with one SPN MCB 25 Amp 240 Volt Make : Havells Cat Part No. DHDMCDPO253025 or equivalent make of Legrand/Siemens/ABB/C&S/Indo Asian
Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, for servicing, strip opening of fan, including servicing and greasing complete reassembling and refixing to the same/other location including testing of fan after servicing for smooth and noise free operation complete all as spfd and directed.
S&F in replacement of down rod for ceiling fans 1200/1400mm size made out of 20 mm dia steel tubing medium grade duly threaded incl necessary clamps, hook, nuts bolts, rubber real etc complete all as specified and directed.
Road Schedule
Preparing of Black top surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc and applying evenly a priming tack coat with paving bitumen VG-10 @ 5 Kg/10 Sqm on bituminous surfaces complete all as specified and directed.
M&L applying 40mm thick (consolidated thickness) bituminous premixed asphaltic semi dense concrete with 5.5% paving binder content VG-30 Grade by weight of total mix, rolled and compacted to required camber and gradient to a uniform smooth surface with 8 to 10 tonne power roller complete all as specified and directed. NOTE: Premixing shall be done by using Hot Mix plant and laying shall be done by using mechanical paver complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified.
Removing excavated material (soils) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
Rolling and consolidating formation surfaces with 8 to 12 tonne power roller including filling in soft spots, depressions etc., which occur during rolling (for portion coming in cutting/original ground only) to required camber and gradient etc., including watering before or during rolling complete all as specified.
S&F 150 mm thick (spread thickness) soling (or sub base) with broken boulders or quarried stones, interstices filled with stone chippings, surface formed, rolled and consolidated to required gradient and camber and rolled with 8 to 10 tonne power road roller, complete all as specified.
S&F 150 mm thick water bound macadam (compacted thickness) with stones aggregates (granite/trap or basalt) in two layer each 75 mm thick of grading 2 (63 mm to 40 mm) for first layer and of grading 3 (50 mm to 20 mm size) for second layer, spread watered, rolled with 8 to 12 tonne power road roller and consolidated to re-quired gradient and camber com-plete all as specified.
Preparing of water bound macadam surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt/dust etc and applying evenly a priming/tack coat with bituminous primer of paving bitumen VG-30 @ 10.00 Kg per 10 Sqm of road surfacecomplete all as specified and directed.
M&L preparing black top road surface applying thermo plastic paint on marking of min 2 mm thick single coat a centre line and edge line etc.Road marking of 150/100 mm width using hot mark thermoplastic paint (hot application) white or yellow by indigenous modern propelled road marking machine as directed incl all ingredient such as binder,glass bends,titanium dioxide,calcium carbonate,inter fillers etc,thermoplastic requirement for glass bends shall be confirming to BS-6086 of most specification incl.spraying of glass beads etc as per IRC-35 complete all as specified and and directed by Engr - In - Chagre.
N. K. ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .