| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹15.6 L+₹1.0 L (7.07%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹19.4 L+₹4.8 L (33.0%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
30 Jan 2023, 6:00 pmClosed
Col Jigar Trivedi, SM
HQ CWE (AF) Gurgaon, Old Palam Road, New Delhi Cantt-10
REPAIR / MAINT OF ACS WATER COOLER DEEP FREEZER CEILING FAN/EXHAUST FAN AND WATER HEATER DG SET AND STREET LIGHTS LT/HT REPAIR/ REPLACEMENT OF OLD CI/GI PIPELINE SLUICE VALVE SUBMERSIBLE PUMP AT AF STN NARELA UNDER GE (AF) GURGAON
2023_MES_572687_1
CWE/GGN/GT-30/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Stn Indaur
As per NIT
7 documents required · 7 mandatory
₹500
GE AF Gurgaon
₹45,000
Yes
6 Mar 2023
3 Jan 2023
7 Feb 2023
3 Jan 2023
30 Jan 2023
17 Jan 2023
3 Jan 2023 - 16 Jan 2023
Amount
M & L Dehydration including filtration and cleaning of transformer oil by dehydrating centrifugal machine incl testing till to achieve Di-electric strength 40 KV at 2.5 mm gap including testing of sample before and after dehydration and filtration complete all as specified and as directed by Engineer-in-charge. NOTE : -(i) Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report tobe submitted after completion of Job. (ii) Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
Supply and Filling / pouring new transformer oil as per IS : 335 (Latest revision) for transformers installed at various site or in repair for topping up after dehydration to achieve the di electric strength 60 KV at 2.5 mm gap, complete all as specified and as directed by Engr-in-Charge. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
Repair/ Servicing of transformer of capacity 2 MVA, 33/11 KVA by cleaning all the carbon deposities from the HT/LT bushing ,detecting of leakage of transformer oil, if any and making it leak proof, checking of conservator including replacement of defective parts as under all as specified and directed. Note:- Opening of transformer and reassemble in including quoted rate .
HT Bushing with brass rod (33 KV)
HT Bushing with brass rod (11KV)
Oil pressure gauge
Temp Gauge
Gate Valve (up to 40mm)
Repair/ Servicing of transformer of capacity 250 to 1250 KVA, 11/0.433 KVA by cleaning all the carbon deposities from the HT/LT bushing ,detecting of leakage of transformer oil if any and making it leak proof ,checking of conservator including replacement of defective parts as under all as specified and directed. Note:- Opening of transformer and reassemble in including coted rate .
HT Bushing with brass rod
LT Bushing with brass rod
Oil pressure gauge
Temp Gauge
Gate Valve (up to 25mm)
Material and labour for replacement of existing unserviceable disc type insulator porcelain vitreous 145 mm height and 255 mm dia ball and socket type white brown or green with tension clamp for conductor working pressure 11000 volts complete all as specified and directed.
Supply only Auxilairy contact (7NO +7 NC)(suitable for item No. 6.00 above)
Supply only New Micro switch with ball (suitable for item No. 6.00 above)
Supply only New Micro switch without ball (suitable for item No. 6.00 above)
Supply only RC unit assbly (suitable for item No. 6.00 above)
Supply only Shock Absorber (top) (suitable for item No. .00 above)
Supply only Pressure switch single Level (suitable for item No. 6.00 above)
Supply only O Ring (suitable for item No. 6.00 above)
Supply only TNC switch (suitable for item No. 6.00 above)
Supply only Support insulator 36 KV (suitable for item No. 6.00 above)
Supply only Tulip contact 15 finger (suitable for item No. 6.00 above)
Supply only contact bolt (suitable for item No. 6.00 above)
Supply only Bushing -R 36 KV VHA Cub (1250 A) (suitable for item No. 6 above)
Supply Only in replecement of thermostat Note:- Items 6.01 to 6.13 to be Fixed in item No 6.
Supply only Bushing 400 series bolted type (suitable for item No. 7.00 above)
Supply only shaft for operating handle (suitable for item No. 7.00 above)
Supply only Aux switch (suitable for item No. 7.00 above)
Supply only Insulated bushing cover (suitable for item No. 7.00 above)
Supply Only in replecement of thermostat Note:- Items 7.01 to 7.05 to be fixed in item No 7
Supply and fix of Current Transformer suitable for VCB 33 KV panle current ratio is 50/5 Amp and class IP-10 protection complete all as specified and directed by Engineer-in-Charge.
M& L in replacement of cable jointing kit for 11 KV grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 185 Sqmm 3 core complete all as directed by Engr-in-charge .
M& L in replacementof cable jointing kit for 11 KV grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 185 Sqmm 3 core complete all as directed by Engr-in-charge .
M& L in replacement of cable jointing kit for 11 KV grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 240Sqmm complete all as directed by Engr-in-charge .
M& L in replacement of cable jointing kit for 11 KV grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 240Sqmm complete all as directed by Engr-in-charge .
Material and labour for straight through joint Cold shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 240 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Material and labour for straight through joint Cold shrinkable 1100V earthed system suitable for XLPE cable of size 3.5 x 25 - 95 Sqmm incl taking down old unsv LT joint complete all as directed by Engr-in-charge .
Material and labour for straight through joint Cold shrinkable 1100V earthed system suitable for XLPE cable of size 3.5 x 185 - 300 Sqmm incl taking down old unsv LT joint complete all as directed by Engr-in-charge .
Supply, install, test and commission lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating incl complete connections in replacement complete all as specified directed.
Supply, install, test and commission lightening arrestor suitable for HT 33 KV expulsion type 65 KA 11 KV rating incl complete connections in replacement complete all as specified directed.
M&L for PT Fuse indoor 33 KV 110V complete all as specifed and as directed by Engineer in Charge.
Supply only in replacement of silica gel 4-6 mesh suitable for transformers breather and protect HT/LT panels from moisture as per site requirement complete, all as specified and as directed.
M&L for replacement of AC Ammeter of size suitable for existing ampmeter with input 0 -1 AAC and range 0 - 40 AAC with CTR Aux supply 230 V ; 50 Hz complete incl all connections and programme setting in existing 33 KV main incoming Panel all as specified and as directed by Engr in Charge.
M&L for replacement of AC Voltmeter with input 0-120 V AC and range 0-36 KV AC with CTR 50/5A Aux supply 230 V ; 50 Hz complete incl all connections and programme setting in existing 33 KV main incoming panel all as specified and as directed by Engr in Charge.
M&L for replacement of existing Multi function meter with input 0-120 V AC and range 0-36 KV AC with 33 KV/110 V Aux Supply complete incl all connections and programme setting by the service engineer in existing 33 KV panel as per meter placed in panel all as specified and as directed by Engr in Charge.
M &L for calibration of Auxillary relay for transformer trip functions such as bucholz relay trip/WTI trip/OTI trip fixed on 33 KV control panels for power transformer with all respects and making all alignments properly including connecting with phase indicator on control panels for smooth functioning of tripping system Test Certifacate to be submit after calibration complete all as specified and directed. Note:- Calibration to be don by authorized representative /Service Centre
S&F in replacement compact LED type DC indicator lamp & holder assembly of capcity 50 Volts of colours as in existing panel with fitting /fixtures suitable for 33 KV and 11 KV VCB control panels connections with existing wiring & taking out old unservicable indicators from panel completete all as specified and directed by Engr in Charge.
S&F in replacement digital type Ampere Meter suitable for 11 KV RMU /VCB panel to Check the outgoing load connections with CTs & taking out old unservicable meter from panel completete all as specified and directed by Engr in Charge.
Supply and fix in replacement push to close /open button assembly for Circuit Breaker 33 KV complete all as specified and directed by Engr in Charge.
Supply and fix in replacement push to close /open button assembly for Circuit Breaker 11 KV complete all as specified and directed by Engr in Charge.
S&F in replacement PT Fuse 11 KV suitable for 11KV/110 V PT completre all as specified and directed
M&L for detecting of fault in HT UG cable any size with fault locator equipment to locate the fault in HT cable of length not less than 50 RM . Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy upto 6 to 8 Hrs on this account will be acceptable otherwise penality will levied Rs 1000/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.
Taking down the existing cables from trenches of any size all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 300Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Same as item No 32 but size 3.5 core X 95 sqmm
Same as item No 32 but size 3.5 core X 50 sqmm
Same as item No 32 but size 3.5 core X 35 sqmm
Same as item No 32 but size 4 core X 25 sqmm
Same as item No 32 but size 4 core X 16 sqmm
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in Hard /soft soil and getting out all as specified and directed.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, all as specified and directed.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, as specified and directed.
M&L for boring/auguring suitable hole & insertion of upto 100 mm dia GI pipe including pipe not less than 600 mm below existing PCC/road/hard standing complete all directed. Notes :- (a) Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted.
Supply and laying sand cushioning for cable protection in trenches all as specified and directed.
Supply and laying un-reinforced precast concrete LV cable cover class Type I with 250 X 150 X 40 mm, as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6mm thick burried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 2.25 m below the normal ground level surrounded from all sides by mixure of charcoal and common salt and electrode connected to and including galvanised iron earth strip 25x4mm means of galvanised iron bolts, nuts, check nuts and washers and earth strip protected by galvanised iron pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore Medium grade for watering including test point 75x75x25mm all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed. NOTES: (i) Value of earthing should be less than 3 Ώ (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length GI earth strip 25x4 mm.
S & F in repair MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
S & F in repair MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
S & F in repair MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
S & F in repair MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
S & F in repair MCCB 3 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA
supply & fix Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered Complete all as specified & directed
supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified & directed
M & L crimping type sleeve joints for jointing conductors/ jumper connections including treatment with conducting jelly for 33 KV HT conductor all as specified and as directed.
S&F LED indicator lamp for LT panel (Red / Green/Blue/Yellow) complete all as specified and directed
Supply and fixing female contact spring loaded having brass contacts suitable for GOD up to 1250 Amp for working pressure 33KV volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation complete all as specified and directed.
Supply and fixing male contact with arching horn having brass contacts suitable for GOD up to 1250 Amp for working pressure 33KV volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation complete all as specified and directed.
M& L in replacement of cable jointing kit for 33 KV grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 300 Sqmm 03 core complete all as directed by Engr-in-charge .
M& L in replacementof cable jointing kit for 33 KV grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 300 Sqmm 03 core complete all as directed by Engr-in-charge .
Taking down U/S street light fitting of any size watt capacity of any make/type from pole all as specified and directed.
Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as specified and as directed.
M&L for wiring PVC insulated, stranded sheathed copper cable conductor size 1.5 Sqmm 3 core and drawing through Pole or S&F steel rigid conduit not less than 20mm dia and fixed on pole includingincluding connecting to Bus Bar & earth dolly complete all as specified and as directed.
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 60 watt rating and extendable upto 48 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 70 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
M&L for bracket for street light fitting suitable for Octagonal Pole made of 40mm bore Medium grade GI tube bent to shape as required, fixed with and including bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc all as directed.
Supply and fixing in repacement of Octagonal pole cable Connector isolation strip with 4 terminals & 6 Amp MCB including fixing with street light poles using necessary nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
Supply and fixing Air termination, single pointed, copper rod 24mm dia and 300mm long complete all as specified and as directed by Engr-in-Charge
Supply & fixing Lightening arrestor pole 3 mtr long, 80 mm GI pipe medium grade including Concrete work for fixing GI pole verticaly on roof complete all as specified and as directed by Engr-in-Charge
Supply and fixing Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled, screwed including 3 nos. 8mm dia 25mm long hex. head screw & brezing all joints complete all as specified & directed
Net Contract Sum will be after deducting Sch of Credit of Rs 57,276.00
YASHVI ENGINEERS
AARYANS GLOBAL INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .