Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC BANSHBARI MALDA | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹12.8 L+₹1.6 L (14.8%)Rejected-Finance VILL KRISHASAIL P O KHAMRA DIST MURSHIDABAD PIN 742213 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742213 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹13.2 L+₹2.1 L (18.5%)Rejected-Finance 184 BHUPENDRA ROY ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹30,880
Closing Date
28 Dec 2020, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Renovation with Electrical Installation works at ART centre of OPD Building under BSMC and H, Bankura
2020_WBPWD_308596_1
WBPWDTE/EE/BED/NIQ_103/Q of 2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,880
Bankura
7 Jan 2021
10 Dec 2020
30 Dec 2020
10 Dec 2020
28 Dec 2020
11 Dec 2020
11 Dec 2020
120 days
Amount
Dismentling the existing E.I. work by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make- L &T / Legrand/ Siemens of the following sizes as to GS 8way Enclosure upto 160 Amp
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( L &T / Legrand/ Siemens) as to GS. 8way Enclosure
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make- L &T / Legrand/ Siemens ) as to GS 2+12 way Enclosure
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment Make- L &T / Legrand/ Siemens as to GS. 8 way
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection Make- L &T / Legrand/ Siemensas to GS. 160 Amp
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make- L &T / Legrand/ Siemens, as to GS. 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make- L &T / Legrand/ Siemensas to GS. 6A - 32A SP MCB
63A TP MCB
S & F MCB SS enclosure with IP-20/30 protection, powder coated provision for two / four pole MCB concealed in wall after cutting the wall & mending good the damages to original finish incl. painting , connection & provision for earthing attachment 4 way with 100 Amp MCB
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster / approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish Average run 11 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster /approved by EIC)as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer Board )
Supply & Fixing 240 V, 2 nos. 6A, plug socket with separate 2 nos. 6 A Piano key type switch, (Brand approved by EIC) on suitable size sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI/ Gloster / Mescab ) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug)
2 x 6 sqmm + 1 x 4 sqmm ( from TPN MCB DB to SPN MCB DB s )
4 x 16 sqmm + 2 x 10 sqmm (for AC machine )
Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar /KEI/Polycab/ approved) as per direction of EIC 4 core 35sqmm ( from VTPN to MCBPBDB )
4 core 95 sqmm ( from Panel to VTPN )
S&F of hanger at inside the existing masonry trench of PMSSY project and laying of cable with 3 tire arrangement appx 18'' long as per appvd drawing andthe cable hanger made with MS angle 50 mm x 50 mm x 5 mm painting with 2 coats of RO primer and one coat of appvd. Paint with grouting on wall by fastener system incl scaffolding arrangement if reqd. as per direction of EIC
Laying of following sizes Al. armoured PVC/XLPE cable surface on wall / on wall by clamp / concealed as reqd. with with 2 x 10 SWG GI wire as per direction of EIC upto 3.5/4 core 35 sqmm to 50 sq mm with 2 x 10 SWG GI wire
upto 3.5 / 4 core 50 sqmm to 3.5/4 core 95sq mm with 2 x 10 SWG GI wire
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 35sqmm
4 core 95 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 35sqmm
4 core 95 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
S & F 250 V 50 HZ 18" (450 mm) high flo oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator ( Make -CG/Orient/Approved)
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Fixing 2'x2' recess mounted LED lumineries made in CRCA sheet metal with wide light window and also with an opaque acrylic diffuser for a spot less and grade free uniform lighting and the fitting complete with all acxcesories to Havells make Cat no-VENUSEOHE 2 X 2 PLR 18-42 W LED (With 5 years warranty) 36 W corresponding to Wipro/Bajaj/ Crompton as per direction of EIC
Supply & Delivery of Microprocessor based air cooled 11.0TR ceiling suspended ductable type Split Air Conditioner having nominal cooling capacity of 132000 BTU/hr. at ISI condition suitable for operation on 415V, + 5% - 50 Hz. - 3Ph AC supply. Each unit consist of one or two nos. Scroll or twin rotary compressor with R-410A Refrigerant. as per direction of EIC. (Make: Hitachi/Daikin/OGeneral/Mitshubishi)
Erection & Commissioning Charges for 11.0 TR Ductable Split Air Conditioner with Nitrogen flashing, Preasure testing.
Supply, installation & commissioning Copper Refrigeration pipe line for liquid (1/2" or 5/8"OD SD 0.6mm thick) line with supports & brackets (For 11.0 Tr Ductable split AC)
Supply, installation & commissioning Copper Refrigeration pipe line for Suction(7/8" or 1 1/8"OD HD 0.6mm thick) line with 9mm thick Nitrile Rubber Insulation, supports & brackets (For 11.0 Tr Ductable split AC)
3 Core 2.5 Sq.mm IDU to ODU Power Cable
3 Core 1.5 Sq.mm IDU to ODU Comminication Cable
Supply, installation & commissioning PVC Drain pipe line (25mm OD HD 1mm thick) with insulation & supports & brackets (For 11.0 Tr Ductable split AC)
Supply & fixing of fire retardant nonporous double layer flexible connection between each unit and duct as per direction of E.I.C.
S/F of aluminium Powder Coated Grill with VCD(Make: Air Kolkata/Primier)
Supply & Fabication of Sheet metal Supply ducting & Pleanum Chambber complete with supports Hanger etc.of the following as per direction EIC. 24 SWG( Make: Sail/Tata)
Supply & Fabication of Sheet metal Supply ducting & Pleanum Chambber complete with supports Hanger etc.of the following as per direction EIC. 22 SWG( Make: Sail/Tata)
Supply & fixing of 9 mm thick Foil face Nitrile rubber thermal insulation on duct complete with all accessory as required.(Make- Supreme,K-flex.) as per direction EIC..
Supply & fixing of 9 mm thick Nitrile rubber Accoustic insulation Under duct complete with all accessory as required.(Make- Supreme,K-flex.) as per direction EIC..
Supply & Fixing of 20 G GI aerofoil blades type fire Dampers complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Scaffolding & Lifting charges of ODU & IDU UNIT
SITC of 10 Micron Pre Filter with Machine fabricated GI Section,it will be fitted on Fresh air duct.(Make:Spectrum/Priyanka Engg./AFI)
Supply & Fixing of Bird Screen
S & F Motorised Coller damper
Supply and fixing of UVC EMIITTER for the above fan's for prevention of fungus , The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995) and it should be suitable to fix the same in Fan's Duct.
Supply & Fixing of IDU & Duct Covered with 3mm thick ACP Board (Make:Aludecor/Protap Bond) Coplete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Chrages for Trap door with 22 SWG ACP Board (Make:Aludecor/Protap Bond)Coplete with linkages, levers, fittings, supports, all accessories for IDU Maintenance make with ACP Board as per direction of E.I.C.
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
R.K ENTERPRISE
MODERN ELECTRIC
stage.html
html • 0.05 MB
technical_579314.pdf
PDF • 0.18 MB
techsummary_579314.pdf
PDF • 0.18 MB
finance_579314.pdf
PDF • 0.19 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_579314.pdf
PDF • 0.19 MB
AOC_99Q.pdf
PDF • 0.29 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .