Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.3 L+₹1.1 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹11.9 L+₹1.7 L (16.2%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹12.2 L+₹1.9 L (18.4%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹13.6 L+₹3.3 L (32.0%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹16.9 L
EMD Value
₹34,000
Closing Date
8 Dec 2020, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2020_MES_372909_2
GE/NRC/8784/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹34,000
Yes
15 Jan 2021
5 Nov 2020
12 Dec 2020
5 Nov 2020
8 Dec 2020
24 Nov 2020
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc ( Note - old serviceable switch / socket / regulator / switch-socket / call bell / bell push shall be reused against apropriate items, all as specified and directed by Engr-in-Charge)
Taking down unserviceable / partly serviceable light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls / floor etc to macth with existing surfaces including white washing/colour washing / distempering to match with existing wall / floor / ceiling finishes. (Note - old serviceable fitting shall be reused against apropriate items, all as specified and directed by Engr-in-Charge)
Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and connecting up including provision of cable from ceiling rose or connector to fan all as per specified and directed by Engr-in-Charge
Dismantling unserviceable main switch / DBs with MCBs and wooden board including making good disturbed surface of wall.
Taking down sub main wiring of any size / capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch / Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified One light point controlled by one, one way switch. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
All as per Ser Item No. 06 here in before but, One ceiling / exhaust fan point controlled by one switch and regulator
All as per Ser Item No. 06 here in before but, One 3 pin 5 amp socket out point on the same board with other switches.
All as per Ser Item No. 06 here in before but, One 3 pin 5 amps socket out let point on independent board
All as per Ser Item No. 06 here in before but, One bell / buzzer point controlled by one bell push.
All as per same in item No 06 above but for one socket outlet 15 amp on independent board with 2.5 Sq mm cable and 2.5 Sqmm earth wire.
S & F Switch piano flush type single pole one way 5 amps.
S & F Socket out let 2 in one, 5 / 3 pin 5Amp
S & F Switch socket combination 5 Amps 5 pin flush type
S & F Switch socket combination 5 in 1, 5 pin 5 / 15 Amps flush type universal .
S & F Ceiling rose, surface bakelite 65 x 50 mm three terminal
S & F in repair Call bell AC-230 Volt single pole ding dong
S & F in repair Bell push, flush type 5 Amps.
S & F Electronic regulator 100 / 120 Watt step type
Supply and fixing in repair of lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings including LED bulb 9 watt.
S & F in repair for decorative wall light fixture made up of polycarbonate, suitable for 10 W retrofit LED lamp (Spiral B-22 base) with suitable LED lamp of 10 W including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230 V, 50 Hz, complete all as specified.
Fixing only 20 Watt Batten fitting (4 feet) suitable for LED T8 lamps. Note : Fitting will be issued under Schedule 'B' free for fixing only.
Fixing only 20 Watt LED Tube Light fitting (4 feet) suitable for T8 Batten . Note : Fitting will be issued under Schedule 'B' free for fixing only.
S & F in repair for decorative wall light fixture made up of polycarbonate, suitable for 12 W retrofit LED lamp (Spiral B-22 base) with suitable LED lamp of 10 W including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230 V, 50 Hz, complete all as specified.
Fixing only 18 Watt Batten fitting (4 feet) suitable for LED T8 lamps. Note : Fitting will be issued under Schedule 'B' free for fixing only.
Fixing only 18 Watt LED Tube Light fitting (4 feet) suitable for T8 Batten. Note : Fitting will be issued under Schedule 'B' free for fixing only.
Fixing only LED tube light fitting along with fixture,10 W, 2 Feet. Note : Fitting will be issued under Schedule 'B' free for fixing only.
Refixing of tube light fitting from exisiting position to new position as required at site all as directed and specified . (Note:- The old serviceable fittings will be used as removed against item No-2 above)
Refixing of wooden / PVC rectangular block for mounting, switches, sockets,fan regulator, call bell, bell push etc. with 3 mm thick plastic laminated sheet cover/helum sheet of ISI mark as required on ground including casing capping / conduit of any size, all as specified and directed by Engr-in-Charge. (The old serviceable material will be used as removed against item No-1 above)
Refixing of DB's including MCB's of any size, all as specified and directed by Engr-in-Charge. Note:- The material shall be used as removed against item No 4.
Fixing only LED security / street light fittings 15 W IP 65. Note : Fitting will be issued under Schedule 'B' free for fixing only.
Fabrication,supply & fixing of GI pipe bracket up to 40 mm dia- 0.9 m long & 2 set of clamps made out of 30 x 5mm ms flat & fixed with anchor bolt suitable for 12 / 15 w LED security light fitting
S & F in repair 1 X 9 W LED PL-Lamp suited for installation in existing 2G11 lamp holders including connecting up with twin core twisted flexible copper conductor cable, holders with suitable size, internal wiring of fittings , 230 V, 50 Hz, complete all as specified.
Supply and fix in repair electronic ballast ( T8 FTL) suitable for 1 x 36 watt, all as specified and directed by Engr-in-Charge.
Supply and fix in repair flourocent tubelight for 1 x 36 watt.
Material and labour for sub main wiring power / circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC CASING CAPING not less then 20 mm dia medium Grade fixed on walls / roof / floors all as directed by Engineer in Charge. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit.
Material and labour for sub main wiring power / circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping not less then 32 mm dia medium Grade fixed on walls / roof / floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit.
Material and labour for sub main wiring power / circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC CASING CAPPING not less then 32mm dia medium Grade fixed on walls / roof / floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC casing capping shall be measured as one unit.
S & F in repair, MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 8 way Double door , IP-43-IK09 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed
S & F in repair MCB DB made of sheet steel enclosures with detachable gland plates for flush / surface mounting with bus bars, neutral links and earth bar (without mcbs) , 240Volts SPN with 6 way Double door , IP-42 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed
S & F in repair MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 240 Volts SPN with 4 way Double door IP-43-IK09 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed
Supply and fix in repair for MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps
Supply and fix in repair for MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 32-40 Amps
Supply and fix in repair for MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
Taking down and fixing partly unserviceable LED security light fittings (building) of any make and type for necessary repair including ractifing any kind of electronic disorder / Circuit disorder / replacement of LED strip / all other accessories and make it serviceable , complete all specified and directed by Engr-in-Charge. Note: (1) Ladder to be provided by contractor. (2) Spare i.e driver shall be measured seperately.
S & F in repair electronic driver 12 / 15 Watt suitable for security light fittings new generation energy saving and environmental friendly long life LED street light / building security light of any make and type, all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in gound (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earht strip protected by provision of GI light grade pipe 15 mm light grade bore including provision of pit in PCC (1:2:4) type B-1 using 20 mm graded of stone aggregate with PCC cover including 20mm bore pipe for wetering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal (not less than 40 Kgs, 80 Kgs each) filling with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 42,472.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
M/s Ravi Electrical
sapana enterprises
Mayur Electro Enterprises
SHRI SULAI ELECTRICALS
Veer Brothers
YASHRAJ ELECTRICALS
SHREE SAI CONSTRUCTION
Bidder Name
SHRI SULAI ELECTRICALS
sapana enterprises
SHRI SWAPNAYOG ENTERPRISES
Mayur Electro Enterprises
SHREE SAI CONSTRUCTION
M/s Ravi Electrical
Veer Brothers
YASHRAJ ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .