GARRISON ENGINEER NAVY LKD
Military Engineer Services GE Navy Lakshadweep Coast Guard Road Kavaratti Islands Lakshadweep. Pin 682555.
REPAIRS REPLACEMENT OF RWH PIPE, WATER TANK, REPAIRS CLEANING OF SEWAGE LINE, MANHOLES, SEPTIC TANKS, SOAKAGE WELLS, OVERHEAD TANKS, RAIN WATER TANK, GUTTER, WELL CLEANING UNDER AGE B R I, KAVARATTI OF GE NAVY LAKSHADWEEP
2022_MES_556954_1
8346/E8
Open Tender
Civil Works
Item Rate
300 days
GARRISON ENGINEER NAVY LAKSHADWEEP
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NAVY LAKSHADWEEP
₹38,000
Yes
26 Dec 2022
11 Oct 2022
10 Nov 2022
11 Oct 2022
7 Nov 2022
25 Oct 2022
11 Oct 2022 - 18 Oct 2022
Amount
Cleaning of existing of sewage lines of 150mm bore by using suitble device required for removing blockage of line like mud silt and other debris and burruying the debris obtained from the sewage line at a distance exc 100 m and not exc 200m, washing the line by flushing water though pipe line and including taking precautionary and safety measures complete all as specified and as directed by Engineer-in-Charge.
Cleaning of manholes upto 1m depth including pumping out liquid sludge / waste materials taking out solid materila from the man hole /chambers burruying the debris obtained from the manhole at a distance exceeding 100m not exc 200m washing MH with fresh water including taking all precutionarly and safety measures complete all as specified and as directed by Engineer-in-Charge.
All as per item no.2 but depth of manholes exc 1.00 mtr but n.exc 2.00 meter complete all as specified and as directed by Engineer-in-Charge.
Labour only for removing blockage of wc indian/Europian type urinal /bath or kitchen trap inclundng clanining of wc pan /floor trap/ nahani tarp and removing blockage of down take pipe up to 1st man hole complete all as specified and as directed by Engineer-in-Charge.
Demolition and breaking up to drain pipe 150mm dia (SGSW,AC,SWR, RCC ) set in cement mortar complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches soft and loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed by Engineer-in-Charge.
Material and labour PCC (1:3:6) type C2 (using 40mm graded aggregate) as in bed to drain pipe , 110mm bore including packing under & hauching against the sides of pipes after they are laid tested including necessary shuttering and suprt to concrete complete all as specified and as directed by Engineer-in-Charge.
Supply and fix PVC SWR pipe 110mm dia single socketed in any length laid in trenches or floor complete all as specified and as directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed by Engineer-in-Charge.
Returning filling in soft and loose soil incl spreading leveling watering wall ramming in layers n.exc 25cm thick complete all as specified and as directed by Engineer-in-Charge.
Removing excavated surplus soft and loose soil n.exc 50m and depositing where directed at a level exc 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick/ stone/PCC block masonry built in cement mortar/cement lime mortar complete all as specified and as directed by Engineer-in-Charge.
Material and labour Pre -cast cement concrete block masonary with solid blocks made out of PCC 1:3:6 type C-1 (20mm graded aggregate) set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slab for man holes/drainage/septic tank cover , set in cement mortar 1:4 incl necessary from work complete all as specified and as directed by Engineer-in-Charge.
Material and labour TMT bars 6mm to 8mm dia and over cut to length, bent to shape required including cranking, bending hooking ends, and binding spirally for hooping column hooking ends and binding with and including mild steel wire not less than 0.9 mm dia complete all as specified and as directed by Engineer-in-Charge.
Clening and removing of all scals and dirt from the shallow well of any dia and 3m depth including bailing out of water etc with clean water with bleeching powder ( internal surface) complete all as specified and as directed by Engineer-in-Charge.
Bailing out waste water from septic tank 10 to 25 user upto top of sludge/broken media using sewage pump by manual and taking out of sludge and removing the same to a distance of exc 50m away from the starting point and deposting in the pit not exc 10 sqm on plan and not exc 1.5m depth and coverd by ordinary soil to thickness not less than 30cm from existing ground level including sprinking of bleaching power over the area of trenches and septic tank and including necessary excavation and earth work in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
All as item no. 20 above but 25 to 100 user septic tank complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair PVC SWR pipe 75mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair PVC SWR bend 75mm dia with oval access door complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair PVC SWR pipe 110mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inreapair PVC SWR bend 110mm dia with oval access door complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair PVC SWR pipe 150mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair PVC SWR bend 150mm dia with oval access door complete all as specified and as directed by Engineer-in-Charge.
Supply and fix rotational moulded polythene water storage tanks (Cylindrical vertical with closed top)hoisted fixed in position and connected all as specified capacity of tank 500 litre (ISI marked) including dismantling of tank complete all as specified and as directed by Engineer-in-Charge.
Supply and fix rotational moulded polythene water storage tanks (Cylindrical vertical with closed top)hoisted fixed in position and connected all as specified capacity of tank 750 litre (ISI marked) including dismantling of tank complete all as specified and as directed by Engineer-in-Charge.
Supply and fix rotational moulded polythene water storage tanks (Cylindrical vertical with closed top)hoisted and fixed in position and connected all as specified capacity of tank 1000 litres (ISI marked) including dismantling of tank complete all as specified and as directed by Engineer-in-Charge.
Supply and fix rotational moulded polyethylene water storage tank 5000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of tank complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ball valves suitable for 25 mm bore iron pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cleaning of pvc water storage tank of capicity exc 250 lit not exc 500 lit on roof or at any postion ( and or bringing down if requred ) by drsining out intier water remoing sludge mud etc ,brushing /rubbing with wire / nylone brush/mop to remove all algae / fungal growth and moss etc entirely from walls floors ceilling etc washing clean with fresh water by using water jet and then again washing and treating with anti bactarial agents disinfectants and bleeching powder and writing in approved font of size 100 mm high the date of cleaning and next due date back synthetic ennamal paint over a white base and rubbishing of the premises complete all as specified and as directed by Engineer-in-Charge.
All as per item no. 33 above but capicity of water tank exc 500 lit and not exc 1000 lit complete all as specified and as directed by Engineer-in-Charge.
All as per item no. 33 above but capicity of water tank exc 1000 lit and not exc 5000 lit complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepairs ball valves suitable for 25 mm bore iron pipe / cpvc pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minimum weight 455 gms) complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 16 mm outer dia of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floor including all pipe fittings such as ends, elbows, unions, tee,reducing tees, adoptors, sockets, plugs hose clips etc and fixing cutting through walls, floors and their making good or layilng on walls/ceiling or in trenches and also cutting, screwing and wastge, Including taking down old pipes and fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 20 mm outer dia of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floor including all pipe fittings such as ends, elbows, unions, tee,reducing tees, adoptors, sockets, plugs hose clips etc and fixing cutting through walls, floors and their making good or layilng on walls/ceiling or in trenches and also cutting, screwing and wastge Including taking down old pipes and fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 25mm outer dia of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floor including all pipe fittings such as ends, elbows, unions, tee,reducing tees, adoptors, sockets, plugs hose clips etc and fixing cutting through walls, floors and their making good or layilng on walls/ceiling or in trenches and also cutting, screwing and wastge Including taking down old pipes and fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair 20mm outer dia CPVC Stop Valve as per required at site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair 25mm outer dia CPVC Stop Valve as per required at site complete all as specified and as directed by Engineer-in-Charge.
DemolItion of cement concrete (unreinforced) of any description and in any position above or below ground level complete and clearing off the permises complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cement concrete (1:2:4) type " B1 " ( using 20 mm graded stone aggregate) as coping, kerbs, cills, steps, parapets, RCC chajjs slope kerbs water troughs and the like rounded or chamfered on edges including necessary form work. ( Item also applied in broken RCC chajjas and roof projection) complete all as specified and as directed by Engineer-in-Charge.
Dismantling tiling of single layer Mangalore Pattern roof tile laid in cement mortar complete all as specified and as directed by Engineer-in-Charge.
Material and labour for roof tiles, Mangalore Pattern, interlocking at side the size of tile match with existing tile joints laid in cement mortar complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 45 above but except tile complete all as specified and as directed by Engineer-in-Charge.
Material and labour for ridge tiles, Mangalore Pattern, set and jointed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 47 above but except ridge tile complete all as specified and as directed by Engineer-in-Charge.
Material and labour for welding inrepairs n.exc 2.5cm in length, thickness of metal to be welded Exc 6mm but n.Exc 9mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing confirming Fe-410W (Gde E-250) quality complete all as specified and as directed by Engineer-in-Charge.
Cleaning of rain water gutters of any dia circular or semi circular shape complete all as specified and as directed by Engineer-in-Charge.
Demolition and breaking of Rain water harvesting pipe 150mm dia complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair UPVC 150 mm square Euro Guard rain water harvesting roof Gutter pipe including bend,stopper, all fitting and necessary form work and making good of existing surface up to 4m, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair UPVC 150 mm square Euro Guard rain water harvesting roof Gutter pipe including bend,stopper, all fitting and necessary form work and making good of existing surface up to 7m, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix inrepair UPVC 150 mm square Euro Guard rain water harvesting roof Gutter pipe including bend,stopper, all fitting and necessary form work and making good of existing surface up to 10m, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs GI flat ,angle, pipe for supports brackets for rainwater pipe & well grills, hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wind ties; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles with fabrication including bolts complete all as specified and as directed by Engineer-in-Charge.
Taking down of existing stay MS rope and Supply and fix of 12 mm dia MS rope for tying for flag post including adjustable clamps complete all as specified and as directed by Engineer-in-Charge.
KRA Engineering and Construction
M/s PATEL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .