| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.1 | Less credit of old pumping machinery.- | 3 | Nos. | - | - |
| 1.2 | DO meter with Optical Probe , Thermo , WTW, Hach, Metrohm Display 3.5` color display DO barometer accuracy ±3 mbar DO barometer range 300 - 1,100 mbar DO barometer resolution 1 mbar DO calibration points 2 DO measuring accuracy mg/L `0.00 - 8.00 mg/L: ±0.1 mg/L 8.00 - 20.00 mg/L: ±0.15 mg/L 20.00 - 50.00 mg/L: ±10%` DO measuring range % saturation 0.0 - 500% DO measuring range mg/L 0.00 - 50.00 DO measuring resolution % saturation 0.1% DO measuring resolution mg/L 0.01 DO response time T99: (20 s DO salinity compensation manual DO salinity compensation range 0.0 - 70.0 PSU DO selectable measuring units % air sat: mg/L: ppm: µmol/L: mbar: torr: dphi DO temperature range 0.0 - 60 °C DO temperature resolution0.1 °C Good Laboratory Practice (GLP) Yes, data with User ID, timestamp, electrode ID Measuring inputs 2 Measuring mode 1 x pH/U/T analog 1 x pH/U/T/DO digital Memory size 10,000 measured values mV accuracy ±0.2 mV mV range -1,200.0 mV - plus 1,200.0 mV mV resolution 0.1 mV pH accuracy ±0.003 pH pH calibration points 1 - 5 pH range -13.000 - plus 20.000 pH resolution 0.001 pH Power supply Lithium-polymer rechargeable battery 3.7 V: 3,000 mAh Protection class IP67 | 2 | Nos. | - | - |
| 1.3 | Pump Control Panel for 3 phase, 50 HP along with VFD (Variable Frequency drive) for Horizontal centrifugal pump operation with electronic soft starter and necessary switch gear. Additionally, Smart Energy meter and Auto/ Manual Selection switch as well as On/Off push buttons to be provided. Panel also contain remote operation of pump through relays operated by potential free/ open collector Digital outputs of RTU cum Gateway device. | 2 | Nos. | - | - |
| 1.4 | NON CLOG SEWAGE PUMP: Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentiond as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. ` 6300 LPM x 25.00 M Head (For MPS) | 3 | Each | - | - |
| 1.5 | ONLINE OUTLET EFFLUENT WATER QUALITY MONITORING SYSTEM b) Supply, installation, testing and commissioning, operation and comprehensive annual maintenance of effluent quality monitoring system for online (Continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED. TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluent and as contained in scope of work in the DNIT complete in all respects as per approved NIT. a) Multi-parameter measuring converter, for connecting upto 18 intelligent sensors Scope including 8 analog inputs/Outputs (4 inputs and 4 outputs) (o/4-20 Ma), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV-VIS range for measurement in the outlet/ effluent of plant with integrated with automatic cleaning complete in all respects as per approved NIT. b) Robust digital pH/ ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature compensation (ATC) cable length 100 Meter (minimum) complete in all respects as per approved NIT. c) Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to intelligent sensors net system cable length 100 Meter (minimum) complete in all respects as per approved NIT. | 1 | Nos. | - | - |
| 1.6 | Replacement of Air Blower Pipes from Air Blower To MBBR Reactor including Difuser at STP into Stainless Steel upto 200 mm i/d complete inall respect With credit of old M.S pipe Removed From Stp | 1 | Job | - | - |
| 1.7 | Credit of Unserviceable blower available at site Complete. | 2 | Nos. | - | - |
| 1.8 | Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY MEDIA SCRUBBER consisting of support structures, ductwork for scrubber, blower, dry scrubbing tank, dry scrubbing media, piping, motors, controls, exhaust system and other essential accessories Chlorine gas dry media scrubber shall be provided as a safety device for use with chlorine (Cl2) gas cylinders in case of emergency. System includes: - Chlorine gas dry media scrubber for safety in case of chlorine (Cl2) gas leakage at site by scrubbing of chlorine gas consisting of: - 1. Instrumentation with hood and ducting 2. Exhaust blower 3. Scrubber with packed bed 4. Vents to atmosphere 5. Control Panel 6. Prefab Porta Cabin of size 1.83 metre X 1.83 metre and height 2.2 metre with one side slope design with 50mm PUF wall panels and Pre Painted galvanized (PPGI) sheet at 20/60 mm corrugated PUF roof panels with Pre-painted galvanized (PPGI) sheet with door, windows etc. complete in all respect Operating Procedures: - The CHLORINE GAS DRY SCRUBBER will consist of non-toxic dry scrubbing media that can scrub chlorine (Cl2) gas with high efficiency. The dry scrubber shall be compatible with existing chlorine gas leak detector installed at site and shall automatically operate through the output signal from the leak detector in case of chlorine (Cl2) gas leakage. Technical Specification: - I. Performance Requirements: - 1. Ducted with full vacuum chlorination system shed. 2. Quantity of the media should be such so that it can scrub a minimum of 900 Kg chlorine (Cl2) gas. 3. System activation on leakage detection by chlorine gas leak detector. 4. Non-toxic, non-hazardous and landfill disposable dry media II. Operational Requirements: - 1. Housed in an IP54-rated enclosure. 2. Compatible with chlorine (Cl2) gas leak detectors having any analog or digital output with provision for auto-calibration with the leak detector. III. Environmental Requirements: - 1. Power Supply: 420AC 2. Blower speed: 1400 cubic feet per minute (cfm) 3. Removal Efficiency: 99% 4. Removal capacity of media: Minimum 15% by weight 5. Operating temperature: 0 to 50 °C 6. Operating humidity: 0 to 95% non-condensing relative humidity Installation: - 1. Contractor/Agency will install the chlorine gas dry scrubber in strict accordance with the manufacturer’s instructions and recommendation. 2. Contractor/Agency after installation will provide basic training for operation to the staff free of cost. 3. Contractor/Agency will use original spares for maintenance. | 1 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_620415.xls
BOQ • 0.27 MB
778810Z170970.pdf
Additional Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].