| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹66,680 (2.83%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹26.5 L+₹2.9 L (12.4%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
2 Nov 2020, 5:00 pmClosed
Raja Nagender Singh
NIRMAN SADAN , 4TH FLOOR, CIVIL LINES , PWD B and R (Elect.)GURUGRAM
Widening strengthening of Delhi Mathura Road to Dholagarh in Distt. Palwal (Pdg. Street Light)
2020_HRY_138317_2
PWD (Elect.) 2020
Open Tender
Electrical Works
Works
90 days
XEN(E) Gurugram
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Electrical Division
₹48,400
2 Feb 2021
20 Oct 2020
3 Nov 2020
20 Oct 2020
2 Nov 2020
20 Oct 2020
Amount
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. Size 1.50 sqmm ( 48 / 0.20mm).
Moulded case Circuit breakers. Suply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
Miniature Circuit Breaker and Isolator. Suply and erection of miniature circuit breaker/ isolator 240/415 V in the existing distribution board including making necessary connection. Miniature circuit breakers of 9 KA breaking capacity. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
(Q) Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
Extra for using salt and charcoal / coke for pipe earth electrode as required.
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refiling of trenches. 16 Sq. mm 4 Core Ard. Cable .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 16 Sq. mm 4 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
Street Light. Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangemrnt , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections .
Supply and errection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. HDPE pipe 63/50 mm outer dia/ inner dia.
Supply and errection of Hot Dip Galvanized octagonal pole 3 mm thickness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangements for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. 9 Mtr. Long pole with top dia 70 mm and bottom dia 155 mm with base plate of size 260 x 260 x 16 mm
Suply and erection of moulded case circuit breaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection equired to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work. 4 pole MCCB 6 to 63 amp.
HIGH MAST POLE Suply, installation, testing and commissioning of 12.5 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 6 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top Section = 3 mm (Minimum). Bottom Section = 3 mm (Minimum Top Dia = 150 mm Bottom Dia = 360mm Thickness of Galvanization Top = 65 micron (Min.) Bottom = 85 micron (Min.)
Supply and erection of 120 watts LED street light fittng with lense IP 66, HP dia cast aluminium hoising including erection of same on pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
Supply and erection of 150 & 250 watt. LED flood light fitting including erection of same on pole/ parapet with necessary nuts & bolts and making necessary connection of same complete in all respect. 150 watt LED flood light
Supply and erection of single/ double arm bracket made of 50 mm dia G.I pipe B class ISI 1.5 mtr. long with 25 mm dia G.I. bottom pipe with 75 mm dia 60 cm. long G.I. collar pipe, top covered with ornamental cap duly welded, painted 2 coats of aluminium paint on bracket and golden paint on ornamental cap including erection of same with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work. Single arm. G.I. Bracket
Supply and erection of Double door sheet steel superline/ Powerline Vertical distribution boards suitable for TP/ FP veritcal MCCBs upto 125 amp as incomer (but without cost of MCCB) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (load line) 4 way load line
Supply and erection of RCC 1:1.5:3 for making Foundation of high mast of size: 1m x 1m x 2.5m, with minimum 8 nos. 16mm dia, longitudinal MS reinforcement Rods with rings of 8 mm dia at distance of not more than 200 mm for fixing pole alongwith 1:8:16 brick ballast bed of height 15cm. with all labour and Material required to complete the job in all respect upto entire satisfaction of Engineer- in- charge
Supply and erection of 32 amp. 3 pole/ 230 volt - digital time switch including cost of contactor, MCB for controlling the street light with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work.
Charges of boaring upto 2.5 mtr. below the gound level treanchless horizental by HDD machine (for laying the cable & pipe) including all labour and material required to complete the job in al respect with cost of laying of 50 mm dia plane HDPE pipe.
Balraj Singh Contractor
ADVANCE ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .