| 4 | L4₹93.8 L+₹8.9 L (10.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹85 L
EMD Value
₹1.5 L
Closing Date
10 Apr 2025, 6:00 pmClosed
CWE
HQ CWE NO 2 DELHI CANTT-10
SPECIAL REPAIR OF P-115 GOVT MD ACCN (OR) AT SHEKHAWATI LINE UNDER GE WEST DELHI CANTT- 10
2025_MES_695683_2
CWE/SW/TOKEN-36/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE WEST DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE WEST DELHI CANTT-10
₹1.5 L
27 May 2025
20 Mar 2025
12 Apr 2025
20 Mar 2025
10 Apr 2025
27 Mar 2025
Amount
Demolition of cement concrete (reinforced) of any description and as in roof slab, kitchen slabs, shelves, chimney etc not other specifically provided for complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not other specifically provided for complete all as specified and as directed.
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and as directed.
Demolition of mud phuska on roof slabs, any thickness including cleaning of roof surfaces and removing the debris upto the distance exc 1.00 Km but not n.exc 1. 5 Km complete all as specified and as directed.
Dismantling of PVC water storage tanks exc 250 & n.exc 500 ltrs capacity and removing from site complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, Internal dia of pipe 100mm complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, Internal dia of pipe 75mm complete all as specified and as directed.
Taking down cement or cement lime plaster on walls incl racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and as directed.
Taking down wooden/steel chowkhats/door frame including shutter (without taking off shutter from frame) exc 1.5 Sqm and n.exc 4 Sqm each and removing to or from store complete all as specified and as directed.
Taking down wooden/steel chowkhats/door frame including shutter (without taking off shutter) not exc.1.5 Sqm each and removing to or from store complete all as specified and as directed.
Taking down shutter of any description exc 1.00 Sqm and not exc 2.00 Sqm complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including Brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floor or in any position laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of brick work built in cement /lime mortor in any position / situation in walls/parapets complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections incl cleaning for refixing or removal to store complete all as specified and as directed.
All as per item No. 16.00 here-in-before but 20mm bore.
All as per item No. 16.00 here-in-before but 25 mm bore.
All as per item No. 16.00 here-in-before but 40 mm bore.
Scraping old tar felt roof treatment over concrete padding of any thickness etc from roo including finishes or junction or parapet and cleaning the surface complete all as specified and as directed.
M&L for providing Cement concrete 1:5:10 in filling of sunken portion and sub base type E2 using 40mm graded aggregate complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone agreggate) as in roof kerb or mud slops, rounded or chamfered on edges, plinth courses, coping, kneelers, apex stone, kerb water tough and the like including weathering, slightly rounded or chamfered angles and throating as directed) complete including necessary form work complete all as specified and as directed.
M & L for RCC M-25 design mix grade cement concrete for reinforced cement concrete work, as in slabs, beams, parapet wall, RCC wall,RCC column etc in any position using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering, shuttering, form work, finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.The Mix design as per particular specfications shall be got approved by Accepting officer before execution of the item.The rate shall include cost of all specified materials and operations at all levels and heights, including the cost of centering, shuttering and form work excluding reinforcement which shall be paid under relevant item.(Note :- Cement content considered in this item is @ 300 kg/cum as per IS 456 table showing minimum cement content. No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled concrete) .
M&L for water proofing treatment to roof surface with APP polymeric based water proofing membrane 3mm thick & weighing not less than 3.5 Kg / Sqm of approved make black finish consisting of a central core of high molecular high density polyethylene film (HMHDPF) & reinforced with non woven polyester matt of min 160 gm/sqm with a thermo fusible finish laid over a coat of hot blown bitumen of 85/25 grade conforming to IS 702 @ 1.2 kg/sqm over a coat of an bitumen primer conforming to IS-3384 @0.4 Ltr/Sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing including applying a coat of cold emulsion bituminous primer complete as per manufacturer's instructions complete all as specified and as directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make / manufacturer. (ii) The APP Membrane to be inserted in the parapet wall/wall by cutting chases of atleast 65mm X 50mm size& making good in CM 1:3.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and as directed. (Rate of WPC shall be included in unit rate)
M&L for 20cm x 20cm x20mm thick PCC tiles bedded in cement mortar (1:3) over and including 15mm thick screed bed in cement mortar and jointed and grouted flush in CM 1:3 mixed with 5% crude oil by weight of cement complete all as specified and as directed.
M&L for pre cast cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in Kitchen slab, passage roof etc and set in cement mortar 1:4 complete all as specified and as directed.
M&L for brick work with sub class 'B' brick straight or curved on plan exc. 6 mtr mean radius built in cement mortor 1:6 complete all as specified and as directed.
All as per item No. 28.00 here-in-before, but half brick thick in cement mortar 1:4.
M&L 20 mm CPVC pipes SDR 11 with all plain CPVC SDR 11 and brass elbow, Tee, MTA/BTA Adeptor,tank adeptor etc. CPVC fittings and fixed complete to walls, ceiling or laid in floor complete all as specified and as directed.
M&L 25 mm CPVC pipes SDR 11 with all plain CPVC SDR 11 and brass elbow, Tee, MTA/BTA Adeptor,tank adeptor etc. CPVC fittings and fixed complete to walls, ceiling or laid in floor complete all as specified and as directed.
S&F for tubes 25 mm dia, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F for tubes 40 mm dia, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for cutting chases for inserting GI tubing in walls, floor etc and making good complete all as specified and as directed.
S&F rotational moulded polythylene water storage tanks 500 Ltrs capacity, double layered (cylindrical vertical with closed up) hoisted and fixed in position complete all as specified and as directed.
S&F 100 mm bore cast iron soil waste or vent pipes in any length with or without ears with lead joints laid in trenches or in floors/ walls complete all as specified and as directed.
All as per item No. 36.00 herer-in-before but 75mm bore of pipe.
S&F 100 mm bore cst iron 'P' or 'S' traps fixed with lead joints complete all as specified and as directed.
S&F 100 mm bore cast iron bends/T (any radius) diminishing pieces or tapers (larger bore to be measured) with oval access doors complete all as specified and as directed..
All as per item No.39.00 here-in-before but 75mm bore of pipe.
S&F 100 mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches including oval access door complete all as specified and as directed.
All as per item No.41.00 here-in-before but 75mm bore of pipe.
S&F of CI Cowl for 100mm bore complete all as specified.
S&F in repairs 10 ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and as directed.
S&F in repair vitreous china water closet Orissa type 580 x 440 mm white with integral foot rests including provn of lime concrete bedding including connections to flushing cistern pipe and making good disturbed portion to match existing surfaces including P or S trap complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin (flat black) white of size 550x400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified and as directed.
S&F in repairs CI floor trap with grating including jointing to waste pipe in run lead with dia of outlet 75 mm including floor around to required depth and burning lead joints etc to facilitate dismantling old CI trap and making good complete all as specified and as directed.
S&F in repair PVC (SWR) bends 150 mm bore complete all as specified and as directed.
S&F in repair PVC (SWR) 150 mm bore rain water pipes single socketed in any length with rubber ring joints fixed to walls / spout pipe complete all as specified and as directed.
S&F mild steel framed work as in door or gates of angle or other sections, cooler stands, with gusset plates rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel sheeting or other covering, running rails and guides) and hanging, fastening and fixing complete conforiming to Fe 290 Gde E-165 complete all as specified and as directed..
S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat complete all as specified and as directed.
S &F factory made 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I). klin seasoned and chemically pressure treated complete all as specified and as directed.
M&L for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm fixed to door/window frame complete all as specified and as directed.
S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm fixed to door/window frame complete all as specified and as directed.
S&F butt hinges 100mm size, medium weight cold rolled mild steel and fixed to angle iron /steel chowkhat complete all as specified and as directed.
S&F 100mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and as directed..
S&F aluminium anodised barrel tower bolt, extruded section 200mm size complete all as specified and as directed.
S&F aluminium anodised Handles for 150mm size complete all as specified and as directed..
S&F aluminium anodised Handles for 100mm size complete all as specified and as directed..
S&F 300mm aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F 4.8 mm thick figured glass/ pin head type and glazing in squares not exc 0.5 Sqn in each pane complete all as specified and as directed.
S&F 4.8 mm thick sheet glass ordinary quality and glazing in square not exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F 100 mm hasp and staple, mild steel stove enamelled black. Including bolt to hinges plate and fixed with screws complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of wood or wooden base surface of any description not otherwise described over 10cm width or grith and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
All as per item No. 64.00 here-in-before but on steel surfaces over a coat of redoxide primer.
M&L for Preparation of old wooden surfaces of any description not otherwise described over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and as directed.
All as per item No. 66.00 here-in-before but one coat of paint on old steel surfaces.
M&L for ready mix plaster 15 mm thick on fair faces of brick work or concrete surfaces of walls (Internal) complete all as specified and as directed.
M&L ready mix plaster 15mm thick on fair faces of brick work or concrete surfaces of walls (External) complete all as specified (Height of bldg upto 4 story).
M&L ready mix plaster 10 mm thick on ceiling surfaces of walls (old ceiling) complete all as specified and as directed.
M&L ready mix plaster 5 mm thick on ceiling surfaces of walls (New ceiling) complete all as specified and as directed.
Complete removal and preperation of old surfaces of walls by scrapping with mechanical grinders complete all as specified.
M&L for two coats of oil bound distemper including preparation of new plastered surfaces over one coat of alkali resistant primer over & including 1mm thick wall care putty complete all as specified.
M&L for two coats of oil bound distemper on old surfaces of walls by complete removal of old treatment & preparation of old surfaces over one coat of alkali resistant primer over & including 1mm thick wall care putty complete all as specified and as directed.
M&L for three coat of white washing on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L for two coats of white washing on old plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L for three coat of white washing on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
M&L for two coats of white washing on old ceiling surfaces including preparation of surfaces complete all as specified and as directed.
M&L for preparation of old treated brick surfaces of walls upto 4th storey height by scrubbing with wire brush, hard brush, washing down with water and applying two coats of cement paint, white or tinted over one coat of alkali resistant primer complete all as specified and as directed.
M&L for preparing new plastered surfaces of wall upto 4th storey height and applying two coats of cement paint, white or tinted over one coat of alkali resistant primer complete all as specified and as directed.
M&L for Chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubbing down concrete surface with wire brushes, cleaning with water, allowed to dry and applying a layer of antirust and then Zinc rich epoxy primer all as specified followed by a layer of bonding coat & then guniting over steel welded mesh 2mm dia of wire and aperture 75mm total thickness of guniting not exc 40mm thick (average thickness) with 15mm thick ready mix plaster and finally applying cement plaster over guniting surface of required thickness to give even, uniform, and smooth finish conforming to proper geometrics in cement mortar 1:3 to match with the existing surface as in sides and soffits etc. slabs, Chajjas, fins, facias, parapets, beams and columns etc complete including necessary scaffolding, shuttering, necessary chases to brickwork or RCC members at any height up to 4 storey building complete all as directed. Note: Steel Welded mesh is to be welded with existing reinforcement. The Cost of welded mesh is deemed to be included in the unit rate quoted and the work to be carried out up to 4 storey bldgs/in floor roofs complete all as specified and as directed.
M&L for 20mm thick, granite (of any type) work (table rubbed and polished) in window-cills, cooking platforms and like in 15mm tihck cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for non skid coloured ceramic rectified tiles 7-8 mm thick (square/rectangular) area of each tiles exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc, set jointed in neat cement slurry & pointed in coloured cement to match and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for coloured printed glazed ceramic tiles of size 450X 350X 7mm on vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white/ coloured cement, laid over and including cement screed bed 10mm thick in cement mortar 1:4, complete all as specified and as directed.
M&L for non skid colour ceramic rectified tiles 8 mm thick (square/rectangular) area of each tiles not exceeding 0.36 Sqm, in floors etc, set jointed in neat cement slurry & pointed in coloured cement to match and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection 75mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen mastic complete all as specified and directed.
S&F in repair aluminium anodised tubular towel rail 20mm dia, D type 60 cm long between flanges, complete all as specified and directed.
S&F curtain rods of anodized aluminium alloy 25 mm dia with fixing brackets stops and rollers etc complete all as specified and directed.
S&F sink made of stainless steel 1mm thick for kitchen with plugs, washers and waste including bedding in cement mortar to dwarf wall or including fixing cantilever, brackets and connecting union to pipe over all size 495 x 420 mm, bowl size 410 mm x 330 mm x 160mm complete all as specified and as directed.
S&F in repairs 15mm bore bib tap fancy type brass with capstan head chromium plated screwed down high pressure with long screwed shank and flynut screwed complete all as specified and as directed.
S&F in repairs 15mm dia chromium plated bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F brass CP vertical mixer for mixing hot & cold water for wash hand basin screwed down for 15 mm bore iron pipe of ferrule complete all as specified and as directed.
S&F CP wall mixer non telephonic type for mixing hot and cold water for shower screwed down for 15 mm brass iron pipe of ferrule complete all as specified and as directed.
S&F in repairs stop valve 15mm bore fancy type chromium plated, with long shank and cup (concealed type) complete all as specified and as directed.
S&F in repairs 15mm bore stop valves/angle valves, cast copper alloys, fancy type chromium plated, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs 20mm bore of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F PVC connection 600mm long with 2 Nos brass check nuts, suitable for 15mm bore complete all as specified and as directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated aluminum rod and high density polythene float and flynut complete, screwed for iron pipe or brass furrule size 25mm bore. (Min weight 210gms) complete all as specified and as directed.
S&F in repairs shower rose, chromium plated brass, fancy type, 125 mm with or without swivel joint, any size, including fixing to steel pipe or union, complete all as specified and as directed.
S&F 25mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as shutter of cupboard complete all as specified and as directed.
M&L for machine cut Kota stone slab 20 to 25 mm thick as in treads, risers of staicase laid over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including cement screed bed 15mm thick in cement mortar 1:6 complete all as specified and as directed.
S&F stainless steel kitchen plate rack made out of stainless steel sheets 1mm thick overall size 600mm x 750mm x 250mm including complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S.square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded pre-laminated PVC sheet having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined suitable PVC sheet beading and joined together with solvent cement and provision of partially louvered frame supply and fixing in the frame at site. Complete all as per specification & sample kept in GE office and as directed.
M&L for teak wood lipping, 6mm thick fixed with nails to 18mm thick veneered particle borad including polishing complete all as specified and as directed.
S&F continous (piano) hinges, mild steel, bright finish complete all as specified.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of of brass polished bright finished complete all as specified and as directed.
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and as directed.
M&L for providing 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate admixed with integral WPC complete all as specified and as directed.(Note: Supply only WPC shall be measured and paid saparately.)
M&L for 10 mm thick cement plaster on brick/ concrete surface in CM 1:3, finished even and smooth surface with out using extra cement but with& using water proofing compound at the rate of 2% of cement by weight complete all as specified and as directed.. (Note: Supply only WPC shall be measured and paid saparately.)
M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound complete all as specified and as directed. (Note : Supply only WPC shall be measured and paid separately)
M&L for providing 40mm dia GI pipe spout projecting at least 150mm beyond outer face of wall complete all as specified and as directed.
M&L for glass fibre reinforced acrylic modified cementious coating system with base coat of Sika Top @ Seal 107 or equivalent @ 1.50 Kg/Sqm fibre reinforcement Sika ® Fab-1 and top coat with Sika Top® Seal-107@ 1.50 Kg/Sqm or equivalent of FOSROC or PIDILITE complete all as specified and directed
S&F framed work such as grills, grating etc. with ends of bars shouldered and /or riveted , or forged into spikes; framed guard bars; barred iron doors; ladders; cooler stand framed balusters; walkways; parapet railings on tubular form; framework of water tanks and similar works conforming to Fe290. Gde-E-165 complete all as specified and as directed. Note : Provision of openable arrangement for placing coolers on stand shall be made in window grill wherever required.
Supply only Integral waterproofing compound.
S&F powder coated aluminium sections (minimum thickness of powder coating 50 micron ) for doors, windows, beading for grill with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated aluminium window and ventilator shutters, side hung type with/ without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2 Nos) suitable handle (1 No) complete all as specified and as directed.
S&F aluminium anodised barrel tower bolt, extruded section 100mm size complete all as specified and as directed.
Taking down wooden door shutter exc 1.00 Sqm and n. exc 2.00 Sqm each and refixing in same opening complete all as spd & directed
S&F powder coated (minium thickness of powder coating 50 micron) aluminium section for shutters suitable for three/four track window and aluminium section weighting more than 0.5 kg/m of sliding members incl all necessary fittings and fixtures, jointing cleats, rubber packing etc complete all as specified and as directed.
Supply and fix CP waste coupling 32mm size with PVC waste pipe, plugs and washers for kitchen sink complete all as specified and as directed.
S&F of floor door stopper of alumimium alloy body and tongue, anodised, with hard drawn steel spring including vulcanised rubber piece of 140mm long complete all as specified and as directed.
M&L for followings :-i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)(i) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved)(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and as directed. (Height of building upto 4 story)
M&L for providing rust proof /anti corrosive treatment to bars -i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(ili) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note: Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coatina complete all as specified and as directed. (Height of bldg upto 4 story).
M&L for providing PMM (Polymer modified cementitious mortar ) :-(i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes) (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note: Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed (Height of bldg upto 4 story).
Supply & fixing 12mm dia steel sheer connector in grid pattern in between old core and Eac new concrete as wherever directed by Engr-in-charge and as specifed by manufactuer Including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA). (The cost of drilling hole &chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed (Height of building upto 4 story)
M&L for Providing & Pouring Micro concreting M-40 grade -(i) Dry concrete substrate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes) (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make: MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc, Adding of aggregates will be permitted only as per manufacturer's recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note: The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item. (Height of building upto 4 story)
M&L for Drilling & chemical anchoring of new rebars/stirrups -i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under -8 mm dia bar - drilling length 80 to 100 mm Note: Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item
M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under -16 & 20 mm dia bar - drilling length 160 to 180 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASE or equivalent FOSROC/SIKÀ) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
Impregnating cream for injection into masonary or concrete wall 230mm thick against capilary rising humidity. Rising bar super strong (Product no. 201) of chowgale building chemicals or equivalent pidlite/Drfixit/sika/phosrock complete all as specified and directed Method of Application Methodology (a) The surface must be sound , absorbent, clean, free of dust, oil, paint, curing agents , loose cement or lime plaster & concrete, debris, or any separation layers. (b) The plaster must be knocked off at least 50cm beyond the visibly penetrated area. (c) Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. All sharp edges/joints need to be levelled ; loose concrete to be removed. (d) Drill boreholes at ground level horizntally. The boreholes are drilled horizontal into the masonry. (e) The holes should be drilled until a depth of approx 5cm (for a 6cm thick wall) before the end of the wall is reached. The boreholes should have a diameter of 12mm upto a maximum of 15mm and should be spaced approx 100-120mm apart and the vertiacal offset is 6cm maximum (f) Before inserting rising bar super strong or equivalent the boreholes must be clean from boring dust by using air pressure. It is not necessary to pre-wet the boreholes. (g) For applying of rising bar of super strong or equivalent the dosing system inserted as far as possible into the bore holes. While dosing the product uniformly, the injection nozzle is pulled out leading to a completely filled boreholes (h) Treatment of highly absorbent masonary mught required repeated filling of the boreholes. depending upon extent of damage, rising bar superstrong or equivalent can be re-injected into the same hole after 24 hrs. depending on observency, application or masonry thickness 0.1 to 0.15 ltr/m with 10cm wall thickness.
M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members :- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed.(Height of building upto 4 story)
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and as directed.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for colour machine pressed precast concrete glossy finished interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade laid over 25mm thick sand cushion with grey cement and pigment complete all as specified and as directed. (Note : Sand filling to be measured and paid seperately)
M&L for sand filling under floors for cushion bed to interlocking paver block complete all as specified and as directed.
M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
All as per item No.138.00 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders complete all as specified and as directed.
M&L for RCC M-25 design mix cement concrete (20mm graded aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs and in shelves and the like all as specified and directed.
S&F FRP chajjas of 450 mm wide suitable for various openings including fittings and fixtures upto 4 storey bldg complete all as specified and as directed.
Refixing of balconey grill without damage inclucing welding, cleaning rust and apply zink priper and fixing same place without any damage to existing structure etc complete all as specified and directed by Engr-in-Charge. (Note : Removing all balcaney grill up to 4 storey building without any damage and refixing same place the cost of refing is included in this item) (Height of building upto 4 story)
M&L for formwork soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200mm thick (Horizontal or slopping with rough finished surface of concrete all as specified and directed.
Supply and fix in repair Brass CP mixer swivel spout for mixing hot & cold water for Sink screwed down for 15mm bore iron pipe or ferrul of complete all as specified and directed.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets, regulators light fittings, conduits, sunken box, etc.) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specified and directed.
Material and labour for concealed point wiring with PVC insulated unsheathed multistranded colour code copper conductor in PVC conduit with FRLS cable1.5 Sqmm size 1100 volts grade conforming to IS:694 in box of 1.6 mm thick including one coat of synthetic enmelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit all as specified and directed for following (Note: Cost of cheesling cutting of existing surface and making good to match with exiating surface shall be deemed to be included in quoted rates.
One light/fan/bell point controlled by one way switch 6 amps.
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
One two way point controlled by 2 way switch 5 amps.
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for one 3 Pin socket 15A Indepentent board complete all as specified and as directed. (Note: Cost of cheesling cutting of existing surface and making good to match with exiating surface shall be deemed to be included in quoted rates.
S&F switch piano type 6 amps single pole one way complete all as specified and directed.
S&F of switch piano type 16 amps single pole one way complete all as specified and directed.
S&F of socket outlet multipurpose 2/3 pin 6 amps flush button type complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1, 3 pin 6 and 16 Amps complete all as specified and directed.
S&F of 2 way switch complete all as specified and directed.
S&F bell push switch complete all as specified and directed.
S&F of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers all as specified and directed.
S & F LED B22 1x 12 W, 220V,AC LED Lamp decorative wall mounting light fitting fixture made up of Aluminum body including LED 12 watt with System level efficacy of the Luminary is > 100 lm/W , Color Temperature-6500K, incncluding connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S & F of Lamp holder, PVC /Polycarbonete type with back plate suitable for batten fittings with connections complete all as specified and directed
Supply and fix LED bulb of 9 watt (B-22), including duly connecting, fixing with all accessories complete all as specified and directed.
Taking down sub main wiring of any sizes.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 10.00 sqmm (Main Cable and neutral) and one run of IC x 10.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 4.0 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and deposit to MES storeyard, complete all as specified and directed.
Supply, Installation, testing and commissioning of 1200 mm sweep BEE 5 star rated, Ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of insulation : B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery not less than 220 CMM,350 RPM (tolerance as per IS:374-2019), THD less than 10%,including remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply complete all as specified and directed.
S & F in repair 10 W bulk head fitting with system level efficiency >= 100lm/W, power factor =>0.9 color temperature 3000K,-6500K, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with adjustible thermal megnatic release complete all as specified directed.
S&F of single pole MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
S&F in repair LED batten luminarie surface mounted system wattage of 20 W and system lumin efficiency=> 100lm/W output power factor =>0.9 color temperature 3000K-6500K voltage range 150-230 V AC including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F 10 W LED light fitting 1X10 W 220 V AC decorative box type with driver, holder including LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F Exhaust fan 300 mm sweep, copper winding, metal body, four metal blades BEE approved/ISI marked, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 220-240 volt, single phase, AC supply and connecting up using flexible wire complete all as specified and directed.
S & F exhaust fan made of strudy engineering plastic complete mounted in suitable opening arrangement in brick wall window with louvers shutter 230 V 50 Hz 1200 RPM copper winding 250 mm sweep complete all as specified and directed.
S&F of Hot water storage type (Geyser)25 Ltrs capacity, BEE 5 star rated,vertical type with suitable size of fastner and incl provision and connecting up of ss braided pipe with adopter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glass lined tank with standing capacity upto 8 bar presuure, having heating element 2 KW, complete all as specified and directed.
M&L for modular AC Box with 20A SP mini MCB, Plastic enclosure & unbreakable Heavy Duty ISI mark Plug Top complete set dully concealed in wall complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
S&F surface mounting LED building security light fitting35 W 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with drive, lamp bracket with impact and corrosin resistant including thermal management in multiple optics complete IP 65/66 protection complete all as specified and directed.
M&L in repair for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode, burieddirectly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth lead protected by medium grade 15 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 B-1 ( including excavation and earth work, disposal of surplus soil to a distance not exc. 50 Mtrs) complete all as specified and directed. Note:-(a). PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (b). RCC pit cover shall be of pre-cast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover all as specified or indicated including testing on completion all as specified and directed.
L G BUILDERS (BID ID -3276126)
A R construction (BID ID -3274904)
H S KALSI AND BROS (BID ID -3275531)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .