Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.8 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹6.7 L+₹74,463 (12.6%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹7.9 L+₹1.9 L (32.7%)Rejected-Finance PAIDI POST FARIDPUR BHOGI NAGINA ROAD BIJNOR UP 246701 | BIJNOR | BIJNOR | UP | 246701 | 3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Fatehgarh
AGE(I) Fatehgarh
REPAIR AND MAINT OF WINTER APPLIANCES AND CERTAIN MISC WORK AT FATEHGARH CANTT UNDER AGE(I) FATEHGARH.
2022_MES_549983_1
AGE(I)/FAT/ET-21 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
PLEASE REFER TO TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹17,000
Yes
21 Nov 2022
1 Oct 2022
24 Oct 2022
1 Oct 2022
22 Oct 2022
8 Oct 2022
1 Oct 2022 - 7 Oct 2022
Amount
Taking down Geyser of capacity 50 ltrs from its existing position after disconnecting inlet and outlet water connection including material and labour for spray painting to Geysrs with one coat of Ist grade synthetic enamell paint of approved colour after preparation of old steel surface including writing serial / MES number as specified (with black colour paint with each letters/figures(in Block) of height n.exc 2 cm ) and refixing the Geysers to its existing position on completion of painting including making inlet/outlet water connection and testing complete all as specified and directed.
dittto as above but for geyser of capacity 25 ltr …… ditto as above…………
Taking down carefully storage type water heater (Geysers) of any make of 50 litrs capacity at any height opening for inspection compete Including heating element inner copper tank etc. De-scaling cleaning and re-assembling of Geysers after repairs carrying out and re-fixing in same position (spares parts as required for repair geyser are measured and paid separately) including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as directed by the Engineer-in Charge.
dittto as above but for Geysers of capacity 25 ltrs .
Supply only 1.5 KW Heating Element, Push/ Screw type with ‘O’ ring complete all as directed.
Supply only 2.0 KW Heating Element, Push/ Screw type with ‘O’ ring complete all as directed.
Supply only 2.0 KW Heating Element, Push/ Screw type with ‘O’ ring with and including aparatus plate assembly suitable for Recold Make geyser as per sample complete all as directed.
Supply only Geyser assembly suitable for 25 ltr capacity ISI marked including dismantling of old unserviceable geyser assembly complete all as specified & directed.
Supply only Geyser assembly suitable for 50 ltr capacity ISI marked including dismantling of old unserviceable geyser assembly complete all as specified & directed.
Supply only thermostate suitable for 50 Ltr Geyser ISI marked complete all as specified & directed.
Supply only thermostate suitable for 25 Ltr Geyser ISI marked complete all as specified & directed.
Supply only bottom cover suitable for 25 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
Supply only bottom cover suitable for 50 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
Supply only LED indicating lamp 230 volts 50 HZ AC suitable for geyser any type (round,squire or rectangular type) any capacity complete all as specified & directed.
S&F in replacement metal clad plug & socket DB with plug top including one MCB single pole 32 Amps 240 volts 50 HZ complete all as specified & directed.
Supply only PVC connection heavy duty 15mm dia 45 cm long with PTMT nuts complete all as specified & directed.
Supply only pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
S&F in repair bib taps 15 mm bore chromium plated fancy type screwed down for iron pipe or for brass ferrule complete all as specified & directed.
M&L for sub main wiring with two single core 6 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 6.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly including dismantling all as specified. ( Note :- Two runs of 6 sqmm (FRLS) and one run of 6.0 sqmm (FRLS) copper conductor shall be measured as one unit length.)
S&F in replacement VTPN DB Multiphase Out going suitable for Mounting MCCB as Incomer of rating 63 Amp Vertical distribution board 4 way with suitable Amp rated bus bar having IP- 42 protection and double metal door concealed in wall with MCCB 63 Amp, 16KA 4 Pole 415V complete connection with aluminium thimbles as required complete all as specified.
Dismantling complete solar water heating system of capacity 500 LPD per day including hot & cold water pipes and hot water tank complete. Repairing the system fixing back in position and testing complete all as specified and as directed. Note:- Rates quoted by the contractor shall deemed to be included for:- (a) Making good the worn out missing nuts bolts, washers, union sockets, flanges and screws etc . (b) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube throughly cleaning the complete panel, making the tubes scale free, and re-assembling the panel. (c) Cleaning hot and cold water tanks. (d) All other materials shall be measured and paid separately under respective items.
dittto as above but for capacity 300 LPD….. dittto as above ….
dittto as above but for capacity 200 LPD….. dittto as above ….
dittto as above but for capacity 100 LPD….. dittto as above ….
S&F MCB single pole & neutral SPN 6 to 32 Amp C series 10KA complete all as specified and directed.
Supply and fixing in repairs solar energy collector panel flat plate type complete of capacity 100 ltrs per day complete all as specified and directed.
Supply only solar energy collector panel glass (Collector toughened Glass) complete of capacity 100 ltrs per day complete all as specified and directed by Eng-in-charge.
Supply only solar panel gasket made out of fine rubber to make system air tight, dust, and water proof complete all as specified and directed.
Supply and fixing in repairs steel water tubing 15/20 mm bore medium grade galvanised with all fittings for transportation of hot water from hot water tank to supply point duly insulated and insulation secured with tape and covered with aluminum sheet 1 mm thick all as recommended by the manufacturer complete all as specified and directed.
Supply and fixing in repairs Gun-metal, globe / angle cock or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15 mm bore pipes.
S&F in replacement of plug top 15 Amp complete all as specified and directed.
S&F in replacement single phase static energy meter of accuracy class 1.0 240 Volt, 50Hz , with Backlit LCD display of rating 5 - 30 Amp measures and display in Kwh,V, I, KW,PF, last month history of Kwh with special features like TOD, Tamper proof, logging, optical communication port & display in absence of power with transperant hinge box including taking out old unsv electric meter and deposited to MES store complete all as specified and directed.
Supply & fixing in repair 'rotational moulded polyethylene water storage tanks of capacity 300 liters (cylindrical vertical with closed top three layer) hoisted and fixed in position conneting all inlet and outlete connection complete all as specified.
MS. BK BROTHERS AND CO
S.M. KAZIM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .