Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 CrAccepted-AOC | ₹19.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹19.8 CrRejected-Finance B 604 VASUNDHRA APARTMENTS PLOT NO 16 SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹19.8 Cr | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹20.6 CrRejected-AOC C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹20.6 Cr | L3 | Rejected-AOC Other than lowest |
| 4 | L4₹21.4 CrRejected-Finance | ₹21.4 Cr | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹22.3 CrRejected-Finance A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹22.3 Cr | L5 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹12.3 L
Closing Date
14 Oct 2023, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
PROVN OF NEW COLLEGE BLDG AND LIVING ACCN FOR COLLEGE OF NURSING AT ARMY HOSPITAL (RR) UNDER GE (E/M) RR HOSPITAL DELHI CANTT-10
2023_MES_611927_1
CA NO CEDZ/TOKEN-17 of 2023
Open Tender
Civil Works
730 days
Delhi Cantt-10
MES contractor enlisted in MES under class SS cat a i having deposited Standing Security of Rs 1500000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹3,000
GE (E/M) RR Hospital, Delhi Cantt-10
₹12.3 L
Yes
1 Nov 2023
5 Aug 2023
16 Oct 2023
5 Aug 2023
14 Oct 2023
7 Oct 2023
5 Aug 2023 - 24 Aug 2023
Amount
INTERNAL WATER SUPPLY S&F 3-in-1 wall mixer with L band provision for overhead Shower with 115mm long bend pipe on upperside, connecting legs & wall flanges made of cast copper alloy, chromium plated fancy type, complete all as specified & directed
-Blank-
ROAD, PATH & CULVERT Preparation of newly laid concrete surface of any description over 10cm thick or width not otherwise described and apply two coat synthetic enamel paint over a coat of primer complete all as specified and directed.
EXTERNAL WATER SUPPLY M & L for pipe of 100 mm dia ductile iron, Class- "K-7" supplied and laid complete all as specified and as directed
RAIN WATER HARVESTING M&L for drilling 250 mm dia borehole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil up to 100 m depth including disposal of surplus soil to a distance not exc. 50 mtr away all as specified and directed.
S&F self preforated holes unplasticised PVC pipes 200mm dia casing pipe perforated holes complete all as specified and directed.
HOT WATER SUPPLY S&F rotational moulded polyethylene water storage tanks 500 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed.
M&L for Fabrication of stand and ladder arrangements for cold water storage tank from MS angle iron of size 50 X 50 X 6mm and 3.15mm thick MS base plate incl one primer coat one under coat and one finishing coat of synthetic paint all as specified and as directed
Supply and laying of CPVC pipes 20 mm SDR 11 & plain CPVC SDR 11 fitting on walls/ceiling or laying in floors alongwith nitrile rubber insulation on exposed surface including fittings for connecting with GI pipe complete all as specified.
Supply and laying of CPVC pipes 20 mm SDR 11 & plain CPVC SDR 11 fitting on walls/ceiling or laying in floors alongwith nitrile rubber insulation on exposed surface including fittings for connecting with GI pipe complete all as specified.
SUMMER APPLIANCES Supply and installation of water cooler non-CFC, stainless steel, electric driven single phase having storage capacity of 120 ltrs and nominal cooling capacity 60 ltrs/hrs including PCC foundation of suitable size for water cooler of suitable size and providing flexible PVC drain pipe as required complete all as specified and directed
Supply and installation desert cooler electric driven single phase PVC body, 3-speed, minimum 40 Litre tank capacity, honeycomb type cooling media, copper wounded motor with minimum 3000 Cum per hour flow capacity, minimum 20 feet air throw, complete all as specified and as directed.
S&F refrigerator, electric driven (single phase) capacity 195 Ltrs BEE 4 star rating complete all as specified and as directed.
S&F refrigerator, electric driven (single phase) capacity 310 Ltrs BEE 4 star rating complete all as specified and as directed.
S&F deep freezer 405 Ltrs (or next higher) single phase 240 Volts 50 Hz with sliding hardened glass top complete all as specified and as directed.
Supply, Installation Electronic Voltage Stabilizer metallic body and connecting with split AC having multi-protection Advance Technology with Transformer Single Phase Naturally Air Cooled Indoor type Wall mounted and designed for Input variation 170 Volt to 250 Volt with Output Voltage stabilized at 230 Volt with accuracy of (+) 2.5% and of capacity 1.0 KVA, complete all as specified and as directed
BOREWELL Drilling not less than 400mm bore hole by rotary method to any depth below the ground level in any kind of rock/soil upto 200 mtr deep including disposal of surplus soil to a distance not exc 50 mtr including transportation of drilling machine at site complete all as specified and directed. Note:- In case of encountering rock prior to 30 mtr depth ,the decision of Garrison Engineer for reboring shall be final and binding.Specific order in writing shall be issued by Garrison Engineer for reboring and the quantities shall vary accordingly complete all as specified and as directed.
Supplying,lowering & fixing in to bore 200 mm dia MS casing pipe,heavy duty as per IS-4270,6mm thick ERW duly welded,both sides socketed ends complete all as specified and directed.
Supplying,lowering & fixing in to bore 200 mm dia slotted MS casing pipe ,heavy duty as per IS-4270 ,6 mm thick ERW ( size and distribution of slots should be as per IS-8110) duly welded ,both sides socketed ends complete all as specified and directed.
Development of tube well by air compressor of capacity not less than 500 CFM at 150 to 200 PSIG approximate capacity as required on ground till to get clear water complete including carrying out yield test complete all as specified and directed.
Yield test for the above well by continuously pumping for 16 hrs to determine safe pumping yield complete all as specified and directed
Supply,installation,commissioning and testing of submersible pump set suitable for delivering water at 150 meter head with commensurating capacity electric motor of capacity 10 HP water cooled operating on 3 phase 415 volts 50 Hz AC supply including water pressure gauge 01 No. with brass cock and steel wire rope of adequate length supporting the pump in borewell complete all as specified and directed.
Supply,lowering and fixing GI Column pipe heavy duty flanged & drilled ISI marked 50 mm dia , as per IS 1239, 3 mtr long, GI flange 12mm thick slots cutting in flanges for passing of subermisible cable including all jointing material such as bolts,nuts and washers & packing sheet and connecting complete all as specified and directed.
Supply,installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel outdoor type,platform mounted ,suitable for 415 vots 3 phase 4 wire,50 Hz AC supply system ,having busbar chamber with insulated copper bus bar 32 Amps rating installed on porcelain insulators. weather proof ,powder coated,totally enclosed with IP 65 protection made out of CRCA sheet MS and 40 x 40 x 6mm thick angle iron frame work,powder coated finish over one coat of red oxide primer inside,front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom ) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 sqmm complete all as specified and as directed.
(a) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim.
(b) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(c) Micro processor based VVVF type main controller with closed loop system.
(d) Car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous.
(e) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking & other accessories.
(f) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being rescued.
(g) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing.
(h) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(j) Door sensor not less than 74 beam, 2D infra red full length
(k) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(l) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown.
(m) Do's & Don’ts chart on stainless steel to be installed inside the car cabin. Provision of display of contact numbers or other instructions.
(n) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.
(o) A hooter systen in case of lift failure along with suitable wiring .
All as per item No 21 here-in-before but suitable to carry 13 passengers
Supply and fixing sheet metal enclosure loadline DB VTPN, 4 way, double door in as incomer, IP-43 dust and vermin proof, vertical type suitable for MCCB as incomer duly fixed on wall on angle iron frame in and including following items complete all as specifed and directed:- (i) MCCB 100 Amps, TPN, 25KA, 50Hz, 415 volts with Thermal magnetic release-01 Nos (ii) RCBO, 40 Amps, 300mA, 4 pole-02 Nos (iii) MCB, 25 Amps, 10 Ka, TPN-01 Nos (Spare)
DG SET Supply, install, testing and commissioning of Auto mains faiure silent type, Accoustic Enclosed diesel engine driven Generating Set, 1500 RPM turbo changed after water cooled 4/6 cylinder and coupled with 100 KVA / 80 KW, 415 volts 0.8 PF (Lag) 50 Hz AC brushless, alternator, mounted on a common base frame alongwith all stn accessories i.e. fuel tank, electric control panel, battery with leads residential silencer as per std scope of supply with AMF (automatic on mains failure) panel type, 415 volts, 3 phase, 4 wire comlete relay panel for noise free compartement (accoustic enclosure) housing all as directed including following accessories for 100 KVA DG Set suitable for ambient condition at Delhi and conforming to condition under IS 4772, 10001/10002, 13364, BS 5514/2613/5000 with the following : -
(b) AC Alternator (Brush Less) : The AC alternator (Generator) shall be designed for an output of 100 KVA / 80 KW at full load for continous rating 10% for over load for one hour at 0.8 (lag) PF conforming to IS-4722 & 13364 or BS-5000 RPM 1500 including self excited and self regulating Electronic voltage panel with all accessories cable terminal for suitable size of glands earth terminal etc complete all as per OEM specifictions.
(c) Diesel Engine : The engine shall be vertical multi cylinder four stroke 1500 RPM water cooled with water pump asembly battery charging alternator of suitable instrument panel, electronic in built governor starting bateries heavy duty with leads (as recommended by the manufacturer) suitable size and length of exhaust pipe with necessary clading materials, exhaust coupling inside accousitc enclosure/ canopy, silencer and exhaust pipe above canopy al as fixtures all as per OEM specification complete as per IS 1602 or BSS-649 & suitale BHP for the generator, (BHP not less than 155 BHP) according to IS-10002, BS 5514, supply and installation of diesel engine driven generating set in cooperating engine of minimum 155 BHP/1500 RPM turbocharged after cooled water cooled with alternator of 100 KVA/ 80 KW, 415 V, 0.8 PF, 50 Hz, AC, brushless alternator mounted on a common base frame alongwith all standard accessories i.e. fuel tank, electric reinforcement of 8mm TMT bars & 100mm c/c borth directions including MS angle in frame of 40 x 40 x 3mm etc to acheive earth resistance less than 01 Ohm including testing complete relay panel for noise free compartment (acoustic enclosure) housing all as directed
(d) The tools as per the manuacturer's list shall be provided by the contractor alongwith the set at no extra cost. (e) Unit rate quoted shall deemed include the control cable from DG set to AMF panel, Diesel oil, Lub Oil, Coolant for Radiator etc for smooth functioning of DG Set during PH I & PH II complete testing (at factory premises before dispatch & at site after commissioning) and full tank filling of Diesel oil after PH I & II testing (at factory premises before dispatch & at site after commissioning) topping of Lub Oil, Coolant for Radiator etc required for commissioning and testing of DG Set
M & L Earthing with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to galvanised iron strip 32 x 6 mm dia by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
FIRE FIGHTING & FIRE ALARM SYSTEM S&F Fire Hydrant cabinet made of 16 gauge MS Sheet double compartment type with 4 mm thick glasses. The cabinet shall be firmly fixed to the wall with expansion bolts. The cabinet shall be powder coated both internally and externally also provide marking on both the compartment for identifying the hose reel or landing valve. The door shall be provided with suitable locking arrangement as per standards.The quote shall include fixing the cabinet to the wall & making good to the wall. The size of cabinet should be sufficient to accomodate the following accessories/items complete all as specified and directed.: a) 63mm dia instantaneous pattern single headed oblique hydrant valve with gun metal cap, GI chain twist release type plug. b) 2 lengths of 15mtrs. 63mm dia reinforced rubber lined hose with instantaneous male and female coupling. c) 1 no gun metal branch pipe with nozzle (63mm x 20mm) with Gunmetal gate/ ball valve (20mm) d) 20mm dia. Reinforced hose reel 30m length as per IS 5132 fitted with 6.35mm dia nozzle and shut off valve (IS 884 - 1969) . The hose reel shall be recessed swing type with reel drum.
S&F 5 kg capacity dry chemical powder (ABC) type (IS-15683) strobed pressure (fire rating 4A 144B) fire extinguisher, MS body with internal & external epoxy coating, safety release device on valve, stainless steel safety pin, UV resistant vinyal label, QR code, ISI marked complete all as specified and as directed.
S&F CO2 type fire extinguisher of 5 Kg capacity IS:15683 SQG (Fire rating 55B) with PESO approved cylinder, fitted inhouse with CO2 as with purity as per IS : 15222, Aluminium collar and valve wheel, metal lined rubber discharge hose, external PU paint coating, UV resistant Vinyl Label, QR Code complete all as specified and as directed.
S& F Meachanical foam 9 ltrs IS : 15683 Stored Pressure (AR-AFFF) Fire Extingusher, MS body with internal & external epoxy coating safety device on valve, 30 mm dia clear view pressure gauge with NRV, stainless steel safety pin, UV resistant vinyl label, QR code, ISI marked, complete all as specified and as directed.
Supply and fixing 6 sqmm 4 core copper conductor PVC insulated sheathed cable complete all as specifed and directed
EXTERNAL ELECTRIC SUPPLY Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated alluminum bus bar 750 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor cable adequate size. The scope of work includes the following :- (Main Panel)
(a) INCOMING (i) MCCB 4 Pole 415 volts grade 400 Amps rating and 36 KA rupturing capacity with adjustable Thermal and Magnetic setting releases - 01 No (ii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485 / MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) - 01 set (v) Cylinderical type heavy duty capacitor, 440 V, 10 KVAr, conforming to relevant IS incl suitable fixing and connection with bus bar - 01 Nos (b) OUTGOING (i) MCCB 4 Pole 415 volts grade 200 Amps rating and 35 KA rupturing capacity -01 Nos (for Hostel Bldg) (ii) MCCB 4 Pole, 415 volts grade 160 Amps rating and 35 KA rupturing capacity -01 Nos (Adm Bldg) (iii) MCCB 4 Pole, 415 volts grade 63 Amps rating and 25 KA rupturing capacity - 01 Nos (Spare) (iv) Space for spare MCCB 200 Amps - 2 Nos (c) Provn of Meter housing along with LT 3P-4W, digital energy meter, Class 1.0 accuracy as per relevant IS and IEC Standards, 40-200A current rating, Anti-tamper features, Self-diagnostic capability, Optical port / RS 232 ,40-200 Amp, 415 V, High Grade Polycarbonate Meter, having dual facility of meter reading from meter reading instrument including customer interface unit for data transfer. Make : SECURE / L & T / Siemens / HPL.to be provided for fixing incl electrical connection with required accessories i.e CT/PT, copper wire, lugs etc
Supply, Installing & testing and commissioning factory made and tested LT feeder pillar box (KIOSK) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 300 Amps for Phase and 150 Amps for Nuetral, installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron framework, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor cable of adequate size. The scope of work includes the following :- (LT Panel No 3 for DG Supply) (a) INCOMING (i) MCCB 4 Pole, 415 volts grade 250 Amps rating and 35 KA rupturing capacity with adjustable Thermal and Magnetic setting releases - 01 No (ii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF,PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485 / MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) - 01 set (b) OUTGOING (i) MCCB 4 Pole 415 volts grade 63 Amps rating and 25 KA rupturing capacity -04 Nos (for 2 Nos lift Adm bldg, 2 Nos lift hostel bldg) (ii) MCB TPN, 415 volts grade 32 Amps rating and 10 KA rupturing capacity - 02 Nos (for FF pump at Adm bldg& hostel bldg) (iii) Space for spare MCCB 63 Amps - 2 Nos
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated alluminum bus bar 150 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor cable of adequate size. The scope of work includes the following :- (LT Panel No 2 Near Mess)
(a) INCOMING (i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity with adjustable Thermal and Magnetic setting releases - 01 No (ii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485 / MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) - 01 set (iv) Cylinderical type heavy duty capacitor, 440 V, 5 KVAr, conforming to relevant IS incl suitable fixing and connection with bus bar - 01 Nos (b) OUTGOING (i) MCCB 4 Pole 415 volts grade 63 Amps rating and 10 KA rupturing capacity -02 Nos (for Principal Cottage & Mess Bldg) (ii) Space for spare MCCB 63 Amps - 1 Nos (c) Provn of Meter housing along with LT 3P-4W, digital energy meter, Class 1.0 accuracy as per relevant IS and IEC Standards, 20-100A current rating, Anti-tamper features, Self-diagnostic capability, Optical port / RS 232 ,20-100 Amp, 415 V, High Grade Polycarbonate Meter, having dual facility of meter reading from meter reading instrument including customer interface unit for data transfer. Make : SECURE / L & T / Siemens / HPL.to be provided for fixing incl electrical connection with required accessories i.e CT/PT, copper wire, lugs etc
Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station, 315 KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement : 2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming / outgoing cables / earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm MS all along the corner of the foundation CSS shall be from OEMs only. Licensed System Integrators of approved OEM are not allowed to supply . Package substation will have the following equipment :-
HT SWITCHGEAR
11kV 630 Amps 21KA / 3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of 1 nos. fixed motorized Vacuum Circuit Breaker Module with a direct cable module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. Vacuum Interrupter, RMU, LT Switchgear and CSS Enclosure shall be of same make to ensure life cycle optimization.
Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.
SF6 Gas pressure indicator.
Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO
Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 nos.
All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set
TRANSFORMER
315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date) Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. - One No. Winding Temperature Indicator with Alarm and trip Contact
LT PANEL
LVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 2 mm thick CRCA sheet
630 Amps 433V 4P 50Hz 50KA, Manual Type with microprocessor release Air Circuit Breaker (ACB)
MCCB 125 Amp, 4 pole, 415V, 25 kA rupturing capacity with adjustable Thermal and Magnetic setting releases”., 415V - 01 Nos
MCCB 250 Amp, 4 pole, 415V, 36 kA rupturing capacity with adjustable Thermal and Magnetic setting releases”., 415V - 01 Nos
MCCB 400 Amp, 4 pole, 415V, 50 kA rupturing capacity with adjustable Thermal and Magnetic setting releases”., 415V - 01 Nos
LED indication lamp -01 (R Y B, set of three)
Street light timer switch comprising of 3 pole contactor and time switch-01
Multifunction energy meter : three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets
100KVAR APFC panel with minimum 12 steps as per following tentive steps ( 5KVARX4, 10KVARX8) through 250A MCCB
All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturer's recomandation are included in scope of work.
OUTDOOR ENCLOSURE
Outdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment. Vacuum Interrupter,RMU,LT Switchgear, Multifunction meter and CSS Enciosure shall be of same make to ensure life cycle optimization.
SITE CLEARANCE Transplantation of green trees from hospital site to given location approximately 15.00 km distance from hospital site including excavation , bar lapping , lifting loading , transplantation ,transplanting, digging pits manure or sludge sand , fertilizer, flooding with water , dressing including removal of rubbish and surplus earth including maintenance for 18 months including weeding watering , spraying and fertilization complete complying with the guideline in consultation with department of forest & wild life all as directed by Eng-in charge.”
Description of Work / Item(s)
Amount
Total amount of Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Road, Path & Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (Boundary wall, gate & fencing) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (Rain water harvesting) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (Hot water supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of Sch 'A' Section X (Borewell) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of Sch 'A' Section XI (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Total amount of Sch 'A' Section XIII (Fire Fighting & FIRE ALARM SYSTEM E/M WORKS) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIII)
Total amount of Sch 'A' Section XIV (Lift) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIV)
Total amount of Sch 'A' Section XV (Demolition & Dismantling) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XV)
Total amount of Sch 'A' Section XVI (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVI)
Provide provisional lumpsum of Rs. 1237000.00 for provision of Basketball Court and Badminton Court
MAGO CONSTRUCTION PVT. LTD.
AMIT ASSOCIATES
NAND LAL PURI AND SONS PRIVATE LIMITED
NARSINGH DEVELOPERS LLP
MAHINDER PAL CONSTRUCTIONS PVT LTD
surendra infrastructure pvt ltd
Pooja Singla Builders And Engineers Pvt Ltd
Pooja Singla Builders And Engineers Pvt Ltd
Ktech Engineer Builders Co. Pvt. Ltd
MAGO CONSTRUCTION PVT. LTD.
MAHINDER PAL CONSTRUCTIONS PVT LTD
surendra infrastructure pvt ltd
NAND LAL PURI AND SONS PRIVATE LIMITED
NARSINGH DEVELOPERS LLP
Bidder Name
AMIT ASSOCIATES
Pooja Singla Builders And Engineers Pvt Ltd
Ktech Engineer Builders Co. Pvt. Ltd
surendra infrastructure pvt ltd
NAND LAL PURI AND SONS PRIVATE LIMITED
MAGO CONSTRUCTION PVT. LTD.
NARSINGH DEVELOPERS LLP
MAHINDER PAL CONSTRUCTIONS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid