| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹25.4 L+₹2.7 L (12.0%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹27.9 L+₹5.2 L (23.1%)Rejected-Finance | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹29.3 L+₹6.6 L (29.3%)Rejected-Finance 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L4 | Rejected-Finance Not become lowest bidder |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
3 Feb 2021, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
PROVISION OF DEFICIENT 02 SUPPLY PIPE LINE NETWORK FOR SIX BEDS OF 12 BEDDED ICU OF MH JHANSI AND OTHER SANCTIONED AND MINOR WORKS UNDER AGE E/M AT GE JHANSI
2021_MES_409339_1
GE/JHA/TOK/64 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹22,000
Yes
19 Feb 2021
4 Jan 2021
6 Feb 2021
4 Jan 2021
3 Feb 2021
21 Jan 2021
Amount
Material and labour for Solid drawn, seamless, de-oxidized, non-arsenical, half-hard, tempered and de-greased copper pipe conforming to EN 13348: 2008 with and including all copper fittings. All copper pipes should be de-greased & delivered capped at both ends. Copper fittings shall be made of copper and suitable for a steam working Pressure of 17 bar and especially made for brazed socket type connections. All copper fittings should be conforming to EN 1254-1, should be factory degreased, certified, and individually packed and identified for medical use. Fittings should be kite marked. Installation of piping shall be carried out with utmost cleanliness. Only pipes, fittings and valves which have been de-greased and fittings brought in polythene sealed bags shall be used at site. Pipe fixing clamps shall be of nonferrous or nondeteriorating plastic suitable for the diameter of the pipe. All joints shall be made of copper to copper and brazed by silver brazing filler material without use of any flux. All brazing shall be done by using a brazing rod CP 104 (5% silver copper phosphorous brazing alloy) and copper-to-brass or gunmetal shall only be joints using brazing rod AG 203 (43% Silver-copper-zinc-brazing alloy) manufactured to EN-1044. Inert gas welding technique should be used by oxygen free Nitrogen gas inside copper pipes while brazing to avoid carbon deposition. Adequate supports shall be provided while laying pipelines to ensure that the pipes do not sag. Suitable sleeves shall be provided wherever pipes cross through walls / slabs. All pipe clamps shall be non-reactive to copper. After erection, the pipes will be flushed and then pressure tested with dry air at a pressure equal to 1.5 times of the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours. All the piping system shall be tested in the presence of the site-engineer or his authorized representative. All exposed pipes should be painted with two coats of synthetic enamel paint and colour codification should be as per IS : 2379 of 1963. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition complete all as specified and as directed by Engineer-in-Charge for the following sizes:- Make: Metalco / Maxflow / Mandev / Metal Gems / Lawton
22 mm (OD) with 1.0mm thickness
15mm (OD) with 0.9mm thickness
Material and labour for Line Isolation valve, Non Lubricated, 900 turn level, Ball type, suitable for oxygen service. All valves shall be pneumatically tested for twice the working pressure and factory degreased for medical gas service before supply complete all as specified and directed by Engineer-in-Charge for the following sizes:- Make : RN / RB
22 mm dia
15 mm dia
Supply, installation, testing and commissioning of three gas Microprocessor Controlled Alarm for Pneumatic & Vacuum Services with and including the following provisions:- (i) Digital Display of Line Pressure for all the services with factory calibrated pressure sensors. (ii) Color coded LED Display of Line pressure status (High – Caution – Normal – Caution–Low) (iii) Audible Alarm for High & Low pressure condition. (iv) Test and Alarm Acknowledge (Mute) facility. (Alarm acknowledge (Mute) time span is programmable from 1 to 60 min). (iv) Programming facility of alarm limits from front panel (Password protected). (vi) Facility to connect to remote alarm box by potential free contacts provided in the alarm box. (vii) Small and compact design. (viii) Imported highly sensitive gas pressure sensors & USA/CE marked power supply. (ix) Mounted on a powder coated MS box. (x) Nut & Nipples are to be provided for connection with Pneumatic supply line. (xi) Low voltage internal operation with input power supply of 220V AC. (xii) Battery Backup (xiii) Easy wall mounting facility. Make: ABS System / MGPS / Global Medlife Solutions / GCE
Supply and fix BPC (Back Pressure Compensated) Flow meter with Humidifier of accurate gas flow measurement with and including the following features and provisions:- (i) Control within a range of 0 – 15 lpm (calibration within +/- 10% ). (ii) It should meet strict precision and durability standard. (iii) The flow meter body shall be made of brass chrome plated materials. (iv) The flow tube and shroud components shall be made of clear, impact resistant polycarbonate. (v) Flow Tube shall have large and expanded 0 – 5 lpm range for improved readability at low flows. (vi) Inlet filter of stainless steel wire mesh to prevent entry of foreign particles. (viii) The humidifier bottle shall be made of unbreakable polycarbonate material and autoclavable at 121 degree Centigrade temperature. Make: ABS System / MGPS / Global Medlife Solutions / GCE
Supply and fix Horizontal Bed Head Panels for ICU with and including the following features and provisions:- (i) Efficient, safe & Robust design in extruded alluminium section. (ii) Smooth curved surfaces, with acceptable colour choice. (iii) It Should have an integrated rail system to mount accessories. (iv) Segregation of services i.e. low voltage supplies, high voltage supplies, and medical gases should be maintained throughout. (v) Entire pipe line should run in continuous horizontal panels with no break for each unit & length as per area where it has to be installed. (vi) Provision for Oxygen outlet - 02 Nos, Vacuum outlet - 01 No, Medical air out let - 01 No, Infusion pump mount pole with adopter for mounting at least two pumps and Electrical outlets- 02 Nos Combined 16A / 6A switch socket. Make: ABS System / MGPS / Global Medlife Solutions / GCE
Supply and fixing of three gases area Valve Box for medical use for three Gas Service of size 15mm X 15mm X 22mm) with NIST Connection & S.S.Valve for O2 supply system complete all as specified and directed by Engineer-in-Charge. Make: ABS System / MGPS / Global Medlife Solutions / GCE
Supply and installation of Ward Vacuum Unit, light weight and compact. The unit should consist of a regulator, A 1000 ml. Reusable collection jar, made of unbreakable poly carbonate material and fully autoclavable at 134 degree centigrade. A wall bracket for mounting the jar assembly on the wall. The vacuum regulator shall be infinitely adjustable and have vacuum gauge which indicates suction supplied by the regulator. Safety trap shall be provided inside the jar to safeguard the regulator from overflowing complete all as specified and directed by Engineer-in-Charge. Make: ABS System / MGPS / Global Medlife Solutions / GCE
Supply and fixing of Gas Outlets with respective gas probe and Hose pipes with the following specifications, features and provisions:- (i) Should fully comply and meets with NFPA-99 standards. (ii) All gas outlets should be duly USFDA or CE marked by the European notified body and should comply with BS 5682 or DIN 13260-2 standard. Copy of certificate to be provided. (iii) Terminal units should have gas indexing geometry. Other gas specific indexing geometries are not acceptable. Terminal unit front fascia should be metal and it should be 100% metal. (iv) Terminal units socket castings shall be permanently coated with a low friction fluoropolymer for maximum reliability and service life. (v) Outlets should be manufactured with a 165 mm long Copper inlet pipe stub which is silver brazed to the outlet body. The inlet pipe should be capable of swiveling by 360 degrees for enabling the same to be connected to the pipeline system. (vi) Outlet should be equipped with a primary and secondary check valve and the secondary check valve should be rated at minimum pressure of 200 psi. (vii) Gas specific components shall incorporate the gas identity marking permanently stamped or cast into the component surface. (viii) In the event the primary check valve is removed for maintenance there should not be any leakage (on-line maintenance should be possible w/o disrupting the functioning of other outlets). (ix) Outlet bodies should be gas specific by indexing each gas service to a gas specific dual pin indexing arrangement on the respective identification module. (x) A large color-coded front plate should be used for ease of gas identification and aesthetic appeal. (xi) Probe roller pins shall be manufactured from stainless steel. (xii) Wall mounted terminal units shall be provided with white ABS mounting box with matching fascia. The mounting box shall have smooth rounded corners to avoid the possibility of injury. A bezel shall be available to cover the plaster edge, provide a neat and easily to clean finish. (xiii) The latch valve assembly should accept only corresponding gas specific adaptors. (xiv) All outlets should be cleaned and degreased for medical gas service, factory assembled and tested, complete all as specified and directed by Engineer-in-Charge for the following type of gas outlets:- Make: ABS System / MGPS / Global Medlife Solutions / GCE
Oxygen gas outlet with matching probe
Vacuum gas outlet with matching probe
Air- 4 bar gas outlet with matching probe
Supply and fix H.P. Tube for Oxygen and Air-5 bar CE Certified
Supply and fix L.P. Tube for ward vacuum unit CE Certified
Material and labour for sub main wiring with 2runs x 2.5 sqmm(Ph & N) + 1run x 2.5 sqmm (earth wire) with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Make of Conduit-AKG/ Atul/ Kalinga/Modi/Precision and Make of Wire - Havells/ Polycab/ Finolex / KEI / Gloster Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (iii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables to avoid any damage to the structure.
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix socket, 6 pin, 6A / 16A Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix 90 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system Lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying complete all as specified and directed by Engineer-in-Charge. Make: Bajaj / Philips / Wipro / Havells
Supply and fix 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 4 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Polycab / Gloster / Universal / Havells / KEI
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to 4mm dia GI wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply, installation & testing of Electric Water Heater storage type, vertical, 25 Liters capacity, minimum 3 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temperature setting and mild steel inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed. Make : Racold/ Venus / Usha / Bajaj
Supply, installation & testing of Electric Water Heater storage type, vertical, 50 Liters capacity, minimum 3 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temperature setting and mild steel inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed. Make : Racold/ Venus / Usha / Bajaj
Material and labour for Tube, 'medium grade' galvanized, with all fittings such as socket, bend, Tee, reducer, union etc of size 15mm bore and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge . Make : Tata / Jindal / Zenith / Prakash Surya / Swasthik
Supply and fix Bib tap, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge. Make : Soma / Leader / Zoloto / JAQUAR / KINGSTON / Marc / Gem / Sieco.
Supply and fix angle valve, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge. Make : Soma / Leader / Zoloto / JAQUAR / KINGSTON / Marc / Gem / Sieco.
Supply, install and testing of evaporative desert cooler having nominal air flow capacity of 3000 Cum per hour with metallic body made out of 23 SWG GI sheet along with front grill and three side shutters with cooling pads etc and body fitted with heavy duty fan motor, copper wound, 1/7 HP, 1360/1400 RPM, three speed control, single phase, 230V, 50Hz with 450mm fan blades and 18 Watt submersible pump complete with float valve, PVC distribution pipe, control switch complete suitable for desert cooler including connecting cord PVC insulated and PVC sheathed copper conductor cable 3 core, 1.5 sqmm confirming to IS:694 up to 2.50 mtrs long fitted with mounted plug top 3 pin, 6 Amps ISI marked complete all as specified and directed by Engineer-in-Charge. Make of Cooler Kit & Pump : CG Power / Khaitan / Marathon Electric Make of Wire : Havells / Polycab / KEI / Gloster Make of Plug Top: Anchor / Glodmedal / SSK / Havells / GM
Supply and erection of Hot dip galvanized tapered octagonal pole of height 7.0 meters in single or double section having top dia 70mm and bottom dia 130mm made up of 3mm thick sheet and welded with a base plate of size 200mm x 200mm x 12mm thick complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 600mm long embedded in PCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of TPN aluminium bus bar system suitable for connecting up to 4 core, 16 sqmm aluminium cable and 01 No. of 6A SP MCB for street light protection inside the pole shaft including provision of 3 core, 1.50 sqmm PVC insulated PVC sheathed copper conductor cable 1100 volts grade conforming to IS:694 from pole junction box to street light fitting drawn through inside of pole . Radium reflector band / strips of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in black colour on yellow background at suitable place on the pole complete all as directed by Engineer-in-Charge. Note: (i) Excavation, Earth Work, RFR etc and RCC shallow foundation as per manufacturer's design shall deemed to be included in quoted rate and nothing extra shall be paid on this account. (ii) Complete detailed drawing of pole and its foundation drawing as per manufacturer's recommendations shall be submitted and got approved from GE before procurement. Make : Bajaj / Philips / Utkarsh
Supply and fix galvanized single overhang 1000mm long GI bracket made from 48.3 mm (OD) ERW pipe for street light octagonal pole with 15 degree of angle for mounting street light fitting complete all as specified and directed by Engineer-in-Charge.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed by Engineer-in-Charge.
Supply and fix 100 Watt LED flood light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP65 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of thickness 5 mm provided with the fixture complete all as specified and directed by Engineer-in-Charge. Make: Havells / Philips / Wipro / Bajaj
M&L for Power Cables, 16 sqmm, 4 core, Aluminum Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured Galvanized Wire or Galvanized Steel Strip, PVC Sheathed, 1100V Grade As Per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles/walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting as per site requirement and testing on completion complete all as specified and directed by Engineer-in-Charge Note: Excavation, earth work and provn of cable protection pipe shall be measured and paid separately under relevant items. Make: Finolex / Havells / Polycab / RPG / KEI / Universal / Gloster
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of cable / pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Kisan / Prince / Tirupati /Supreme / Jain Irrigation Sys
Taking down carefully aluminum / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switches, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, 60 mm deep with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:- Make: Conduit-AKG/ Atul/ Kalinga/Modi/Precision . Wire - Havells/ Polycab/ Finolex / KEI
One light / exhaust fan / ceiling fan/ bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item No. 36 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) Make: Conduit-AKG/ Atul/ Kalinga/Modi/Precision. Wire - Havells/ Polycab/ Finolex / KEI
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
Notes for item No. 36.00 to 38.02: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be dine on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
Supply and fix switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix socket 6 Amps, 2-in-1, 5 pin flush type universal 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix bell push switch flush type 6 Amps, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix call bell ding dong, AC, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix electronic fan regulator rotary type in 5 steps 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
S & F 7 W LED lamp, retrofit type suitable for B-22 holder base with polycarbonate diffuser. Make : Bajaj / Havells / Wipro / Philips/Osram
Supply and fix LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20/22 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. Make: Philips / Havells / Wipro / Bajaj / Osram
Supply and fix integrated LED batten 9/10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. Make: Philips / Havells / Wipro / Bajaj / Osram
Supply and fix integrated LED bulkhead luminaire 10 Watt with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. Make: Philips / Havells / Wipro / Bajaj / Osram
Supply and fix LED street/security light fitting 25 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge. Make: Philips / Havells / Wipro / Bajaj / Osram
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
Supply and fix MCB distribution board, TPN, 4 way with in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately. Make : Legrand / L&T / Schneider / Hager
Supply and fix MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately. Make : Legrand / L&T / Schneider / Hager
Supply and fix MCB 63A, 10 KA, TPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make : Legrand / L&T / Schneider / Hager
Supply and fix MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make : Legrand / L&T / Schneider / Hager
Supply and fix MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make : Legrand / L&T / Schneider / Hager
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. Make: Polycab / Gloster / Universal / Havells
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Kisan / Prince / Tirupati /Supreme / Jain Irrigation Sys
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of cables / pipe and making good the disturbed surfaces by providing PCC 1:2:4 after laying of pipes and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix Hot Press Molded SMC meter box of size not less than 700mm X 480mm X 210mm, double door with transparent glass windows for viewing the meter reading without opening the door, minimum IP-43 degree of protection for indoor use for accommodating 04 Nos X 1 Phase 2 Wire energy meter including cutting the wall surfaces for flush mounting of meter box and making good with cement plaster, putty and paint to match with the existing surface etc as per site requirement complete all as specified and directed by Engineer-in-Charge. Make: Sintex / EPP Composites Pvt Ltd / Hensel
Supply & testing of Metal Top Deep Freezer, 400 Ltrs capacity with corrosion resistant body with high density PUF insulation with R-134a ecofriendly refrigerant, suitable for operation on 230V, 50 Hz, single phase AC supply complete all as specified and directed. Make : Usha / Bluestar / Voltas / Carrier
Supply, installation & testing of Water Cooler, storage capacity 120 Ltrs and normal cooling capacity 60 Litrs per hour with stainless steel body with 02 Nos brass chromium plated cold faucets, with R-134A ecofriendly refrigerant, suitable for operation on 230V, 50 Hz, single phase AC supply complete all as specified and directed. Make : Usha / Bluestar / Voltas /Carrier
M&L for sub main wiring with 2runs x 1.5 sqmm(Ph & N) + 1run x 1.5 sqmm (earth wire) with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Make of Conduit-AKG/ Atul/ Kalinga/Modi/Precision and Make of Wire - Havells/ Polycab/ Finolex / KEI / Gloster Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (iii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables to avoid any damage to the structure.
Supply, connect & testing of automatic volatge stabilizer for low and high voltage cut-off, single phase, AC, 50 HZ, 4 Amps rating, suitable for input voltage range 135V - 280V for deep freezer complete all as specified and directed by Engineer-in-Charge. Make: V-Guard / Volina / Microtek /Sinettrac / Aplab / Power ware
ROHIT ENTERPRISES
M/s Ratan Mechanical Works
ADARSH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .