Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ok |
| 2 | Accepted-Technical | Accepted-Technical OK |
Tender Value
₹18.0 L
EMD Value
₹36,082
Closing Date
19 Aug 2026, 4:00 pmClosed
DIRECTOR NISER
NISER
Major Plumbing Work on as and when required basis in NISER Campus Jatni
2026_NISER_920448_1
NISER/ IWD-Civil/Util/10/26-27/18
Open Tender
Civil Works
Works
730 days
NISER Jatni
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹36,082
31 Aug 2026
4 Aug 2026
20 Aug 2026
4 Aug 2026
19 Aug 2026
4 Aug 2026
4 Aug 2026 - 12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing at all height and loaction (including scaffolding & support system required for work). This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on wallsPN - 16 Pipe, 20 mm OD (SDR-7.4) | 50 | Metre | - | - |
| 2 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing(including scaffolding & support system required for work). This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on wallsPN - 16 Pipe, 25 mm OD (SDR-7.4) | 50 | Metre | - | - |
| 3 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing(including scaffolding & support system required for work). This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on wallsPN - 16 Pipe, 32 mm OD (SDR-7.4) | 50 | Metre | - | - |
| 4 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing(including scaffolding & support system required for work). This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on wallsPN - 16 Pipe, 40 mm OD (SDR-7.4) | 20 | Metre | - | - |
| 5 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on walls PN - 10 Pipe, 50 mm OD (SDR-11) | 20 | Metre | - | - |
| 6 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing(including scaffolding & support system required for work). This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on wallsPN - 10 Pipe, 63 mm OD (SDR-11) | 20 | Metre | - | - |
| 7 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing (including scaffolding & support system required for work). This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. PN - 16 Pipe, 20 mm OD (SDR-7.4) | 50 | Metre | - | - |
| 8 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing(including scaffolding & support system required for work). This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. PN - 16 Pipe, 25 mm OD (SDR-7.4) | 50 | Metre | - | - |
| 9 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing(including scaffolding & support system required for work). This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. PN - 16 Pipe, 32 mm OD (SDR-7.4) | 50 | Metre | - | - |
| 10 | Providing and fixing PPR UnionsPPR Union 20mm (including scaffolding & support system required for work) | 10 | Each | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_967260.xls
BOQ • 0.34 MB
technical.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .