Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.6 LAccepted-AOC ERODE | ₹24.6 L Quoted ₹26.2 L | 1 | Accepted-AOC First Lowest |
| 2 | 2₹27.8 LRejected-AOC NO 225 SOUTH STREET VASISTAPURAM POST THUNGAPURAM VIA KUNNAM TALUK PERAMBALUR DISTRICT 621 716 | ARIYALUR | TAMIL NADU | 621716 | ₹27.8 L | 2 | Rejected-AOC Second Lowest |
| Sl No | Description | Qty | Unit | HariRam Constructions L1 | VR Engineering Construction L2 |
|---|---|---|---|---|---|
| 1.00 | Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 10 persons capacity passenger lift with Machine room as per the following Technical specifications including all taxes and duties.
Technical specifications.
1. Location :Model School Girls Hostel at Nagalur.
2. No of Lift : 1 No
3. Type of lift : Passenger lift.
4. Capacity of lift : 10 persons capacity passenger lift (680 Kgs)
5. Speed : 1 Metre / Sec
6. Type of Drive: specific variable voltage variable frequency V3F drive with enhanced ride comfort and leveling functions.
7. No. of floors: Ground +4 floors
8. Total Travel: 13.2 metres(Approximate)
9. Levelling Accuracy: High level accuracy with smooth and jerk free stopping.
10. Construction of Car: High quality stainless steel car, Neat hair line finish with mirror and handrails.
11. Position of machine: Directly above the lift well.
12. No. of landing entrance: 5 Nos
13. No. of car entrance: one in front only.
14. Car entrance door: power operated V3F drive Centre opening sliding stainless steel scratch proof door with hair line finish.
15. Landing entrance door: power operated V3F centre, opening sliding stainless steel door with hair line finish with provision for emergency key opening at all landings.
16. Lift well existing: 1900mm (width) x 2100mm (depth) (As per IS 14665 Part I 2000) | 1 | No | 22,20,338.98 ₹22.2 L | 23,55,000 ₹23.6 L |
| 1.0117. Lift pit depth 1600mm 18. Car size: 1300mm (width) x 1350mm (Depth) as per IS 14665 (part I) – 2000) 19. Car clear opening: 900mm width x 2000mm height (as per IS 14665) (part I) – 2000) 20. Lift machine room available: 4350mm width x 5000mm (depth as per IS 14665 part I – 2000) 21. Power supply: 400/415 V, 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, AC supply for light. 22. Control: Micro computer (Micro processor) based simplex selective collective control with/without attendant. 23. Car fittings: compact fluorescent lighting with 1No 300mm sweep cabin fan with elegant look and with comfortable ventilation inside the car. 24. Lift well: R.C.C. construction with brick masonry. 25. Indication: UP/Down digital direction and position indicator for all landing and in car 26. Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device. 27. Emergency light: Battery operated light to be provided with Automatic charging device. 28. FireMan’s switch: To be provided at ground floor 29. Minor builders work: included in the scope. 30. Scaffolding: Included in the scope 31. Sill angles and facia plates: included in the scope. 32. Steel for lift machinery: Included in the scope. | |||||
| 1.0233. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 34. Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 35. Provision of intercom with phone: To be provided by lift contractor with one handset in the lift car and another handset in the lift machine room with telecom exchange unit with one trunk and three extension link proton 103, matrix telecom unit and required length of single twisted pair with thickness of 0.5 mm to 1 mm connecting the handsets and telecom exchange unit. 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor announciator with music. 38. Special features: a. Infra red door sensor with full height screen. b. Full width half height rear panel mirror. c. Tubular stainless steel hand rail in cars. d. Voltage stabilizer for circuit control. e. Stainless Steel signal fixtures. f. Vandal proof S.S. Button with S.S. cover g. SS door frames for landing doors. h. VF door operator. i. Call Register signal j. Stainless steel facia plate for car operating panel and landing fixtures. k. Steel ladder for machine room. l. On – Off switch for fan and light m. Over load warning indicator with audio announcement. | |||||
| 1.0339. Provision of architraves covering all three sides upto a width of 300 decolum sheet on plywood with TW frame with aluminium beading architraves should also cover the thickness of still level door frame at the landing and indicator boxes at all landings. 40. Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, single reduction worm gear, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. 41. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of not less than one year. 42. Site testing in accordance with IS 14665 should be carried out at the time of handing over. 43. Supply of operation and maintenance manual with necessary tools for operation. | |||||
| 2.00 | GST @ 18% | 1 | No | 3,99,661.02 ₹4.0 L | 4,23,900 ₹4.2 L |
Tender Value
₹24.6 L
EMD Value
₹22,500
Closing Date
1 Jul 2025, 3:00 pmClosed
The Superintending Engineer
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Providing Additional 1 No 10 Person Passenger Lift in the Model School Girls Hostel Building at Nagalur in Kallakurichi District
2025_PWD_565738_1
6/TVM-CLE/25-26/2/ Dt.20.05.2025
Open Tender
Electrical Works
Nagalur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹22,500
18 Feb 2026
11 Jun 2025
1 Jul 2025
11 Jun 2025
1 Jul 2025
11 Jun 2025
Amount
Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 10 persons capacity passenger lift with Machine room as per the following Technical specifications including all taxes and duties. Technical specifications. 1. Location :Model School Girls Hostel at Nagalur. 2. No of Lift : 1 No 3. Type of lift : Passenger lift. 4. Capacity of lift : 10 persons capacity passenger lift (680 Kgs) 5. Speed : 1 Metre / Sec 6. Type of Drive: specific variable voltage variable frequency V3F drive with enhanced ride comfort and leveling functions. 7. No. of floors: Ground +4 floors 8. Total Travel: 13.2 metres(Approximate) 9. Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 10. Construction of Car: High quality stainless steel car, Neat hair line finish with mirror and handrails. 11. Position of machine: Directly above the lift well. 12. No. of landing entrance: 5 Nos 13. No. of car entrance: one in front only. 14. Car entrance door: power operated V3F drive Centre opening sliding stainless steel scratch proof door with hair line finish. 15. Landing entrance door: power operated V3F centre, opening sliding stainless steel door with hair line finish with provision for emergency key opening at all landings. 16. Lift well existing: 1900mm (width) x 2100mm (depth) (As per IS 14665 Part I 2000)
33. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 34. Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 35. Provision of intercom with phone: To be provided by lift contractor with one handset in the lift car and another handset in the lift machine room with telecom exchange unit with one trunk and three extension link proton 103, matrix telecom unit and required length of single twisted pair with thickness of 0.5 mm to 1 mm connecting the handsets and telecom exchange unit. 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor announciator with music. 38. Special features: a. Infra red door sensor with full height screen. b. Full width half height rear panel mirror. c. Tubular stainless steel hand rail in cars. d. Voltage stabilizer for circuit control. e. Stainless Steel signal fixtures. f. Vandal proof S.S. Button with S.S. cover g. SS door frames for landing doors. h. VF door operator. i. Call Register signal j. Stainless steel facia plate for car operating panel and landing fixtures. k. Steel ladder for machine room. l. On – Off switch for fan and light m. Over load warning indicator with audio announcement.
39. Provision of architraves covering all three sides upto a width of 300 decolum sheet on plywood with TW frame with aluminium beading architraves should also cover the thickness of still level door frame at the landing and indicator boxes at all landings. 40. Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, single reduction worm gear, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. 41. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of not less than one year. 42. Site testing in accordance with IS 14665 should be carried out at the time of handing over. 43. Supply of operation and maintenance manual with necessary tools for operation.
VR Engineering Construction (BID ID -1387680)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid