Loading…
Loading…
Tender Value
₹17.2 L
EMD Value
₹34,500
Closing Date
16 Jul 2026, 5:00 pm
VICE CHAIRMAN GHAZIABAD DEVELOPMENT AUTHORITY
GDA OFFICE VIKAS PATH GHAZIABAD
RENOVATION WORK OF LIBRARY BUILDING LOCATED IN SHASTRI NAGAR SCHEME, GHAZIABAD
2026_GDAUP_1165938_1
677/4/PA-T/2026-27 Dt. 01.07.2026 (S.no-03)
Open Tender
Civil Works
60 days
GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,009
AS PER LINK PROVIDED IN TENDER DOCUMENT
₹34,500
2 Jul 2026
2 Jul 2026
18 Jul 2026
3 Jul 2026
16 Jul 2026
3 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. DSR E/M 2025 item no 1.10.1 Group A Rs 1189.00/per point .(1189.00 x 0.838=996.38) | 16 | nos | 996.38 | ₹15,942.08 |
| 2 | Rewiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. DSR E/M 2025 item no 1.16 Rs 1064.00/per point .. (1064.00 x 0.838 = 891.63) | 2 | nos | 891.63 | ₹1,783.26 |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. DSR E/M 2025 item no 1.13 Rs 587.00/per point ..(587.0 x 0.838 = 491.90) | 8 | nos | 491.91 | ₹3,935.28 |
| 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. DSR E/M 2025 item no 1.15.1 Group A Rs 687.00/per point .(687.0 x 0.838 = 575.70) | 5 | nos | 575.71 | ₹2,878.55 |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required DSR E/M 2025 item no 1.14.1 Rs 267.00/per point . (267.00 x 0.838 = 223.75) | 150 | rmt | 223.75 | ₹33,562.5 |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. DSR E/M 2025 item no 1.17.2 Rs 77.00/per point .(77.00 x 0.838 = 64.52) | 150 | rmt | 64.53 | ₹9,679.5 |
| 7 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating .with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. (8.9.1) 18- 22 Watt. DSR E/M 2025 item no 8.9.1 Rs 681.00/per point .(681.00 x 0.838 = 570.68) | - | nos | 570.68 | - |
| 8 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(8.9.2) 24- 26 Watt as above item no 7 DSR E/M 2025 item no 8.9.2 Rs 692.00/per point .(692.00 x 0.838 = 579.89) | - | nos | 579.89 | - |
| 9 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 63 DELHI SCHEDULE OF RATES (E&M)-2025 (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air
delivery 210 CM/Min (Minimum) DSR E/M 2025 item no 9.2.3 Rs 2695.00/per No .(2695.00 x 0.838 = 2258.41) | 6 | nos | 2,258.41 | ₹13,550.46 |
| 10 | Supply Installation, Testing and Commissioning of Air Cooled Hi Wall splitype Air conditioners complete with Indoor unit(IDU), Out door unit (ODU) surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU cooper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz 1 phase AC supply capable of performing cooling, dehumidification, air circulation a following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor an Printed Circuit Board (PCB), Must comply:Electrical cable IS 694 or 12 9968 temperature sensing control IS /International Electro technica Commission (IEC) 60730, hermetic compressor IS 10617, heat exchange IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPW specification and IS: 1391 Part II 2023. The system shall be able to operat up to 50 DC (out door ambient temperature). Inverter Type -Cooling only 8.2.4 1.0 TR with 5 star BEE rating DSR 32.2.2/2025 | - | nos | 34,006.04 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
677_3.pdf
Tender Documents • 1.40 MB
BOQ_2186743.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid