Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.2 LAdmitted-Finance | -17.90% | ₹14.2 L | L1 | Admitted-Finance |
| 2 | L2₹14.3 L+₹11,902.08 (0.84%)Admitted-Finance | -17.21% | ₹14.3 L+₹11,902.08 (0.84%) | L2 | Admitted-Finance |
| 3 | L3₹14.5 L+₹30,876.43 (2.18%)Admitted-Finance | -16.11% | ₹14.5 L+₹30,876.43 (2.18%) | L3 | Admitted-Finance |
Tender Value
₹17.2 L
EMD Value
₹34,500
Closing Date
16 Jul 2026, 5:00 pmClosed
VICE CHAIRMAN GHAZIABAD DEVELOPMENT AUTHORITY
GDA OFFICE VIKAS PATH GHAZIABAD
RENOVATION WORK OF LIBRARY BUILDING LOCATED IN SHASTRI NAGAR SCHEME, GHAZIABAD
2026_GDAUP_1165938_1
677/4/PA-T/2026-27 Dt. 01.07.2026 (S.no-03)
Open Tender
Civil Works
Percentage
60 days
GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,009
AS PER LINK PROVIDED IN TENDER DOCUMENT
₹34,500
2 Sept 2026
2 Jul 2026
18 Jul 2026
3 Jul 2026
16 Jul 2026
3 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. DSR E/M 2025 item no 1.10.1 Group A Rs 1189.00/per point .(1189.00 x 0.838=996.38) | 16 | nos | 996.38 | ₹15,942.08 |
| 2 | Rewiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. DSR E/M 2025 item no 1.16 Rs 1064.00/per point .. (1064.00 x 0.838 = 891.63) | 2 | nos | 891.63 | ₹1,783.26 |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. DSR E/M 2025 item no 1.13 Rs 587.00/per point ..(587.0 x 0.838 = 491.90) | 8 | nos | 491.91 | ₹3,935.28 |
| 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. DSR E/M 2025 item no 1.15.1 Group A Rs 687.00/per point .(687.0 x 0.838 = 575.70) | 5 | nos | 575.71 | ₹2,878.55 |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required DSR E/M 2025 item no 1.14.1 Rs 267.00/per point . (267.00 x 0.838 = 223.75) | 150 | rmt | 223.75 | ₹33,562.5 |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. DSR E/M 2025 item no 1.17.2 Rs 77.00/per point .(77.00 x 0.838 = 64.52) | 150 | rmt | 64.53 | ₹9,679.5 |
| 7 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025 Colour Matching) <3, Maximum power consumption should not more than the specified rating .with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. (8.9.1) 18- 22 Watt. DSR E/M 2025 item no 8.9.1 Rs 681.00/per point .(681.00 x 0.838 = 570.68) | - | nos | 570.68 | - |
| 8 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(8.9.2) 24- 26 Watt as above item no 7 DSR E/M 2025 item no 8.9.2 Rs 692.00/per point .(692.00 x 0.838 = 579.89) | - | nos | 579.89 | - |
| 9 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 63 DELHI SCHEDULE OF RATES (E&M)-2025 (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air
delivery 210 CM/Min (Minimum) DSR E/M 2025 item no 9.2.3 Rs 2695.00/per No .(2695.00 x 0.838 = 2258.41) | 6 | nos | 2,258.41 | ₹13,550.46 |
| 10 | Supply Installation, Testing and Commissioning of Air Cooled Hi Wall splitype Air conditioners complete with Indoor unit(IDU), Out door unit (ODU) surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU cooper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz 1 phase AC supply capable of performing cooling, dehumidification, air circulation a following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor an Printed Circuit Board (PCB), Must comply:Electrical cable IS 694 or 12 9968 temperature sensing control IS /International Electro technica Commission (IEC) 60730, hermetic compressor IS 10617, heat exchange IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPW specification and IS: 1391 Part II 2023. The system shall be able to operat up to 50 DC (out door ambient temperature). Inverter Type -Cooling only 8.2.4 1.0 TR with 5 star BEE rating DSR 32.2.2/2025 | - | nos | 34,006.04 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
677_3.pdf
Tender Documents • 1.40 MB
BOQ_2186743.xls
BOQ • 0.36 MB
Corri_1.pdf
PDF • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .