Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | ₹44.0 L Quoted ₹44.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹45.1 L+₹19,450.50 (0.43%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | ₹45.1 L+₹19,450.50 (0.43%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹45.6 L+₹72,719 (1.62%)Rejected-AOC | ₹45.6 L+₹72,719 (1.62%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹46.2 L+₹1.3 L (2.96%)Rejected-AOC | ₹46.2 L+₹1.3 L (2.96%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹46.3 L+₹1.4 L (3.17%)Rejected-AOC | ₹46.3 L+₹1.4 L (3.17%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Jan 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
CONVERSION OF LT OH LINE TO LT UG CABLE AT DGQA OFFICE COMPLEX UNDER AGE EM NO II OF GE UTILITY SECUNDERABAD
2019_MES_309905_1
GE(U)/SEC/TOKEN/41 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹96,000
Yes
17 Feb 2020
27 Dec 2019
24 Jan 2020
27 Dec 2019
22 Jan 2020
10 Jan 2020
Amount
(a) MCCB 4 Pole 400-400 Amps 35KA -01 No. adjustable type (incommer) (b) MCCB 4 Pole 200-250 Amps 35KA -1 No. adjustable type (Outgoing) (c) MCCB 4 Pole 160 Amps 25KA -03 Nos. (Outgoing) (d) MCCB 4 Pole 100 Amps 16KA -03 Nos. (Outgoing) (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 SetNote : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces (c) The panel shall be Fabricated from a reputed firm(CPRI Approved) . Make of MCCB's:Havells/L&T/HPL
(a) MCCB 4 Pole 250 Amps 35KA -01 No. adjustable type (incommer) (b) MCCB 4 Pole 200-250 Amps 35KA -2 No. adjustable type (Outgoing) (c) MCCB 4 Pole 160 Amps 25KA -03 Nos. (Outgoing) (d) MCCB 4 Pole 100 Amps 16KA -03 Nos. (Outgoing) (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces (c) The panel shall be Fabricated from a reputed firm(CPRI Approved) . Make of MCCB's:Havells/L&T/HPL
Supply and lay in trenches/fixed to walls/poles etc testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm incl taking out of existing cable all as directed.
All as per item No:03 above but 4 Core 16 Sqmm
All as per item No:03above but 3.5 Core 25 Sqmm
All as per item No:03 above but 3.5 Core 35 Sqmm
All as per item No:03 above but 3.5 Core 50 Sqmm
All as per item No:03 above but 3.5 Core 70 Sqmm
All as per item No:03 above but 3.5 Core 95 Sqmm
All as per item No:03 above but 3.5 Core 120 Sqmm
All as per item No:03 above but 3.5 Core 150 Sqmm
All as per item No:03 above but 3.5 Core 185 Sqmm
All as per item No:03 above but 3.5 Core 240 Sqmm Note for item No 3 to 13 :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
Supply and lay GI tubing , 100 mm bore light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge. Make :- ISI
All as per item No 14 above but 80 mm bore
All as per item No 14 above but 50 mm bore
All as per item No 14 above but 40 mm bore
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 150 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete including taking out old unserviceable one all as specifide and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 35 mtrs each depositing the same for cleaning the site all as directed by the Engr-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25cm thick using excavated soil
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed by Engr-in-Charge.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured as 18cm for payment purpose.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and top 200 mm thick with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
S&F PVC separators for suitable for LT over head line of 5 conductors and all as specified and directed by EIC
Disconnection and removing burntout MCCB's from the existing panels, supply, install, test and commissioning of new MCCB's 415 volts 4 pole 35 KA breaking capacity Adjustable type of 400 Amps Capacity including making conncetions complete all as specified and directed. Make : L&T/Legrand/Havells.
All as per item No 30 above but MCCB's 415 volts 4 pole 35 KA breaking capacity Adjustable type of 315-350 Amps Capacity
All as per item No 30above but MCCB's 415 volts 4 pole 35 KA breaking capacity fixed type of 250 Amps Capacity
All as per itemNo 30 above but MCCB's 415 volts 4 pole 35 KA breaking capacity fixed type of 200 Amps Capacity
All as per item No 30 above but MCCB's 415 volts 4 pole 35 KA breaking capacity fixed type of 160 Amps Capacity
All as per item No 30 above but MCCB's 415 volts 3pole 35 KA breaking capacity fixed type of 160 Amps Capacity
All as per item No 30 above but MCCB's 415 volts 4pole 35 KA breaking capacity fixed type of 100 Amps Capacity
All as per item No 30 above but MCCB's 415 volts 3pole 25 KA breaking capacity fixed type of 100 Amps Capacity
M&L for cleaning thoroughly the street light poles/LT distribution poles of any height and any description (Maximum 11 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coat of synthetic aluminium paint over existing coat of paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPERLAC)/ BERGER (LUXOL)
All As per item No: 37 but for Two pole structure
All As per item No: 37 but for Four pole structure
Taking out and refixing of steel tubuler poles 8/9 m long comple all as specified and directed. Note : rate quoted by the contractor inclusive of Excavation, PCC,Transportation, Dismantling of PCC etc
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with PCC (1:2:4 , type B1) cover ,of 450 x 450 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL.
S&FMCCB box made of sheet of 2mm thick size 30X20X15 CM Powder coated Suitable for fixing at Pole including two set of clamps comprising of the following i) MCCB 63 Amps 16 KA TP WITH BOTH SIDE SPREADER LINK.
Supply and Replace Change over switch 200 amps side handel ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 400 amps side handle /Cubical panel mounting ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying two Coats of Synthetic Enamel Paint (First quality) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
Supply and Replace Spreader link suitable for MCCB up to 125 Amps after taking proper shutdown in existing panel /feederpiller box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 160 A after taking proper shutdown in existing panel /feederpiller box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 200/250 A after taking proper shutdown in existing panel /feederpiller box complete all as directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 185 to 300 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 70 to 150 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 25 - 50 Sqmm 3.5 core complete all as specified and directed
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 160 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 02 NosMake Legrand model no: 420017/ Equivalent from Schinder/L&T/Hagar c)MCCB TP,63 Amp, 3 Pole, 415 Volt, 16 KA Breaking Capacity duly connected to Bus-bar as OUTGOING - 04 N0s.MAKE : Legrand model no: 420003 /L&T/Hagar (d) LED indicating lamps with holder for main supply indicating RYB - 01 set(03 Nos) Make AE/L&T (e) Instrument fuse holder, fused 4 amps - 06 Nos Note: (i) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (ii) All MCCB to be connected with both side Spreader Link. The rate shall deemed to be include in the item rate
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– (a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.b) MCCB 125 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 02 NosMake Legrand model no: 420016/ Equivalent from Schinder/L&T/Hagar
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of size 1MX.75mX.35M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– (a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 NosMake Legrand model no: 420015/ Equivalent from Schinder/L&T/Hagar
Cutting the existing road straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size 100 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size upto 400 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
Cement Concrete 1:3:6 TYPE C2 (40mm Graded Stone Aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork AND FOR FOUNDATION OF GI PIPE , BOLLARD LIGHT (as/if required), complete all as specified and as directed.
Cement Concrete 1:3:6 Type C1 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as/if required), complete all as specified and as directed.
Supply and fixing bracket/clamps made of MS flat strips, angle iron suitable size and shape duly fabricated to be fixed with GI bolts/nuts and washer for fixing of GI bracket, PVC conduit, pole junction box or flood lights all as directed and specified
Dis connection existing LT UG cable of any size from pole/OH line and connect the same to feeder piller box by using cable glands , lugs etc as required complete all as directed
Supply and replace contactor ML 3 with coil operating voltage 230 Volt complete all as directed
S & F Timer Analog Type Suitable for 24 hours operation of street light of 16 amps capacity ( LEGRAND/AVV/CG)
Supply and fix MCB TPN 32 Amps 10 KA, C Curve complete all as directed
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc. and Serviceable Materials keep in Safe Custody for Re-use, complete all as specified and as directed.
Dismantling Insulators from Poles of any description and any size including Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the disturbed Span including Line Spacer, etc. Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
DPS sales and services india
vvcenterprises
The Deccan Engineering and Refrigeration Company
SUN LIGHT HOUSE
Srinivasa Consructions
STANDARD AGENCIES
POWER CONSTRUCTION COMPANY
Sri Balaji Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .