| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.9 L+₹55,198.33 (1.56%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹36.2 L+₹84,261.13 (2.38%)Rejected-Finance 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹38.0 L+₹2.6 L (7.35%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹39.4 L+₹4.0 L (11.2%)Rejected-Finance 2 GA 29 HOUSING BOARD MANU MARG ALWAR 301001 | ALWAR | RAJASTHAN | 301001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
3 Feb 2021, 6:00 pmClosed
GE NASIRABAD
GE Nasirabad Nasirabad cant, Pin 305601 (raj)
PROVN OF SECURITY FENCING FROM MH NASIRABAD TO NH AJMER NASIRABAD ROAD, CHOTI BAZARI TO MH NASIRABAD ROAD ADDN ALTN TO SECURITY FENCING OF OUTER PERIMETER OF CHOTI BAZARI PROVN OF SECURITY FENCING IN REAR AREA OF OTM ACCN OF 813 FD WKSP COY
2021_MES_412129_1
8124/E8
Open Tender
Civil Works
Item Rate
183 days
NASIRABAD
AS PER NIT AND CLASS D CATEGORY a(i) BLDG WORKS
6 documents required · 6 mandatory
₹500
GE Nasirabad
₹92,000
Yes
18 Feb 2021
13 Jan 2021
5 Feb 2021
13 Jan 2021
3 Feb 2021
28 Jan 2021
13 Jan 2021 - 25 Jan 2021
Amount
Surface dressing not exc 15cm deep in soft/loose soil.
Surface excavation in any type of soil not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in any type of soil, complete, all as specified & directed.
Excavation in trenches not exc 1.5 metre wide and exc 1.5 metre but not exc 3.0 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in any type of soil, complete, all as specified & directed.
Excavation in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M&L for PCC 1:3:6, type C2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete, all as specified & directed.
M&L for PCC 1:4:8, type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete, all as specified & directed.
S&F mild steel work as in angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) and similar works conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
Supply only mild steel galvanized chain link fencing 4 mm dia of mesh wire, mesh size 100x100 mm complete all as specified and as directed. Make :- TATA (Wiron)/JINDAL
Fixing only mild steel galvanized chain link fencing, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire.Note :- Supply only chain link fencing shall be measured and paid for separately.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L for cement concrete1:2:4 type B0 (12.5 mm graded stone aggregates) as in copping including necessary form work etc complete all as specified and directed.
Supply and fixing 4.00 mm dia galvanised medium coated as per IS 4826 steel wire as required for fixing chain link fencing etc all as specified and dircted by Engr-In-Charge. Make: TATA (Wiron)/Jindal
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5 cm long and dia of neck 5 to 10 mm complete all as specified.
S&F galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc as directed.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. Make :- TATA (Wiron) /JINDAL
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified.
M&L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint, complete all as specified & directed.
M&L for preparation of new steel and iron surfaces of any descriptionnot exc 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
M&L for reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete, all as specified & directed.
All as per description of serial item No. 23.00 here-in-before but 6 to 10mm dia in stirrups, spacers and binders.
M&L for reinforced cement concrete 1:2:4 (Nominal mix), type B1 using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like, complete, all as specified & directed. .
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete, complete, all as specified & directed.
M&L for reinforced cement concrete 1:2:4 (Nominal mix), type B1 using 20mm graded crushed stone aggregate in columns, pillars, piers, posts, struts and the like, complete, all as specified & directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete, complete, all as specified & directed.
S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
Supply and, laying, including jointing, testing or fixing or passing through pipe, trench or duct, commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade size 10 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge. Make Polycab/Asian/Gloster/Finolex.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top cable including spreading, levelling, watering and consolidation, complete all as specified and directed by Engineer-in-charge. Note: Punned thickness only shall be measured and paid.
Supply and laying of bricks of old class ‘B’ as protection cover to UG cable, laid flat adjoining to each other width wise, complete, all as specified.
Supply and laying GI tubing 40 mm bore, light grade with all fittings, laid in trenches/under floor or fixed on pole/on wall for cable protection.
S&F street light Engineering plastic one piece moulding control box with locking arrangement made out of HDPE and FI clamp 25x3mm complete including one MCB SP 6 Amp 240 Volt complete with 02 Nos aluminium busbar of rating 63 Amp for single phase and neutral on porcelain based insulators and fixing clamps to pole for street lights, complete all specified & directed. Make :- Sintex/ Hensel /SHI/BRITE
Supply, errecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31), 09 metre long, complete with cast iron base plate, pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire lenght of pole, including bracket made of 1.2 m long 40mm bore GI light grade pipe, made to shape with 2x MS clamps & nut-bolts for fixing bracket to poles including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint, complete all as specified and directed.(Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed. Note:- (a) Cost of numbering of pole shall be deemed to included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately.
S&F PVC insulated sheathed copper conductor cable 1.5 sqmm multi-stranded 1100 volt grade, three core for connecting street light fitting from pole to connector DB, complete, all specified and directed.
S & F LED street light luminaries 72 Watt made of single piece Aluminium Die cast with powder coated in RAL-7032 shade with heat distribution fins onhousing with UV stabilized toughned flass cover and should have secondary lens on each LED for better light distribution .The system luminaire efficiancy should be > 110 LM/W with high power LED's. LED driver should be potted and BIS certified with efficiency > 85 % frequency 50 HZ,Operating voltage range 120V-270V, current not more than 0.320 Amp, PF 0.95, THD (I) < 10 %, supported with 5 KV internal and 10 KV external SPD, Humidity 10% to 90 % RH, working temperature - 20⁰ C to 50⁰ C lige expectancy of LED should be 50000 burning houres with minimum 70 % initial lumene maintained, CRI >70, complete, all as directed. Make:- Cat Part No LSTP-72-CDL-M OF Crompton or equivalent from Philips/Wipro
M&L for carrying out boring under the black top road for crossing of LT cable/protection pipe by mechanical boring machine or otherwise without damaging black top surface of road for fixing of GI pipe 80 mm bore under the road complete all as specified and directed.
kirtiman traders
SHREE BALAJI TRADING CORPORATION
Abdul Gani Abdul Sattar
B.S Constructions
VIPRABANDHU CONSTRUCTIONS
PD GUPTA AND COMPANY
M/S AL ASMA ENTERPRISES
M/S JAGDAMBA ENTERPRISES
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .