| 1 | L1₹6.8 LAccepted-AOC GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹7.8 L+₹73,545 (10.4%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹8.2 L+₹1.1 L (16.2%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹9.9 L+₹2.8 L (39.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY |
Tender Value
₹7.5 L
EMD Value
₹15,060
Closing Date
14 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
SPECIAL REPAIR TO E/M INSTALATION AT SHALATENG GARRISON UNDER AGE (I) CIF (K).
2023_MES_597900_1
CA NO. AGE (I) CIF (K)-10/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹15,060
Yes
28 Jun 2023
24 May 2023
16 Jun 2023
24 May 2023
14 Jun 2023
7 Jun 2023
Amount
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supply, installation, testing and commissioning in replacement of CPRI approved LT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system conforming to IS:8623/93, indoor type floor mounting factory made type weather proof, vermin proof, fabricated out of MS CRCA sheet of 3.15mm thick having copper bus bar of rating 400amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner and outer shells. The inner shell duly compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1400mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC 1:3:6, including accomodating the following control gears and suitable size of digital Voltmeter & Ammeter with CTs :-
Supply, installation, testing and commissioning in replacement of CPRI approved LT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system conforming to IS:8623/93, indoor type floor mounting factory made type weather proof, vermin proof, fabricated out of MS CRCA sheet of 3.15mm thick having copper bus bar of rating 400amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner and outer shells. The inner shell duly compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1000mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC 1:3:6, including accomodating the following control gears and suitable size of digital Voltmeter & Ammeter with CTs :-
Supply and replacement of MCCB of capacity 40 Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity 36 KA, 4 Pole, 415 Volts, 50 Hz complete all as specified and directed.(Make- L&T/Legand)
Supply and replacement of MCCB of capacity 63 Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity 36 KA, 4 Pole, 415 Volts 50 Hze complete all as specified and directed.(Make- L&T/Legand
Supply and replacement of MCCB of capacity 100Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity 16KA, 4 Pole, 415 Volts 50 Hz complete all as specified and directed.(Make- L&T/Legand
Supply and replacement of MCCB of capacity 125Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity 36KA, 3 Pole, 415 Volts 50 Hz complete all as specified and directed.(Make- L&T/Legand
Supply and replacement of MCCB of capacity 160Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity 36KA, 4 Pole, 415 Volts 50 Hz, complete all as specified and directed.(Make- L&T/Legand
Supply and replacement of MCCB of capacity 350Amp,adjustable over load and short circuit with micro processing release setting, breaking capacity 50KA, 4 Pole, 415 Volts 50 Hz, adjustable type complete all as specified and directed.(Make- L&T/Legand
Supply and fixing in replacement of Deluxe Automatic Star Delta Submercible Pump Starter with overload relay range of 22-40 amps for 20 HP centrifugal pump set, complete all as specified and directed. Make Havells (Cat Pt. No.1HPREVRD). or equivalent
Supply and fixing in replacement of Deluxe Automatic Star Delta Submercible Pump Starter with overload relay range of 27-35 amps for 15 HP submersible pump set complete all as specified and directed. Make Havells (Cat Pt. No.1HPREVPD). or equivalent
Supply and fixing in replacement of on load change over switch 100 amp capacity Euroload four pole changeover conforms to IS;13947 (part-3) IEC;60947-3 complete all as specified and directed. makeHavells(cat no IHCNFEOIOO)
Supply and fixing in replacement of on load change over switch 320 amp capacity Euroload four pole changeover conforms to IS;13947 (part-3) IEC;60947-3 complete all as specified and directed.make Havells(cat no IHCNFEO320 )
S & F CPRI approved LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening overall size not less than 1200 x 1000 x 450 mm, CPRI approved, IP -52 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 600 Amp rating for 3 phase and bus bar of same capacity for neutrall 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under :
S & F CPRI approved LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening overall size not less than 750 x 600 x 400 mm, CPRI approved, IP -52 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 350 Amp rating for 3 phase and bus bar of same capacity for neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under :
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified as directed by the Engineer-in-Charge.
Providing and laying plain cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate, as in coping including necessary form work and fair finishing of exposed surfaces without using extra cement , complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron strip 25 x 4mm as earthing lead by means bolts, nuts, check nuts and washers made out of galvanised iron, 32 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh including provision of concrete pit in plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I, using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Note :- An amount of Rs.26,800.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S A Q ENTERPRISES
M/S SHIMAR STAR GLACIER
M/S Choudhary Jalaldin
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .