| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.4 Cr | L1 | Accepted-Finance Lowest one |
| 2 | L2₹1.5 Cr+₹5.0 L (3.53%)Rejected-Finance | ₹1.5 Cr+₹5.0 L (3.53%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.5 Cr+₹7.9 L (5.59%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.5 Cr+₹7.9 L (5.59%) | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | - | Rejected-Technical Due to not enlisted in appropriate category |
| 5 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | - | Rejected-Technical Due to not enlisted in appropriate class |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
22 Jun 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR ROUTINE MAINT OF RO PLANT AND AC PLANT WITH MANNING OPERATION AND WATER SUMP AND REPAIR REPLACEMENT OF HT CABLES REPAIRS TO CAPACITORS AND OVERHAULING CALIBRATION FILTRATION OF HT EQPT AND MAINT OF DG SETS AT OUTLAYING AREA UNDER GE NW NOFRA
2023_MES_598861_1
8198
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE NW NOFRA
₹2.2 L
Yes
17 Oct 2023
27 May 2023
24 Jun 2023
27 May 2023
22 Jun 2023
16 Jun 2023
27 May 2023 - 9 Jun 2023
Amount
PART-I Manning and Operation of R.O Plant in three shifts round the clock 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 Hrs including sunday and holiday with cleaning and up keep of the installation operating the submersible pump installed in raw water bore well -02 Nos and operation of treated water pump set including taking care from any pilferage, theft or damage of RO plant etc complete all as specified and directed by Engineer-in-Charge. Notes :- (i) RO operator : 01 No per shift (ii) RO Plants- 02 Nos. (iii) Quoted rate shall be deemed to be for the both RO Plant and shall have out put water capacity not less than 40,000 liters per day. (iv) The Quality of out put water shall confirm to IS 10500 of 1991.
PART-II Routine maintenance of RO plants No. 1 & 2 installed at Vandana and Vishakha complex having out put capacity of drinking water not less than 40,000 ltrs / day, maintenance of chlorine dosing system,coagulant dosing system,antiscalant dosing system carrying out the routine maintenance recommended by the manufacturer for daily, weekly, monthly and quarterly including repairs/ replacement of parts such as bearings, repairs of pumps, filters, welding of cracked/ broken any mild steel items/ foundation, PVC pipes and their fittings, LT panel boards etc complete including painting to all equipment with synthetic enamelled paint complete and all as specified & directed by Engineer-in-Charge including testing of treated water in the approved laboratory for bacteriological test and potability test for every month. Notes :- (a) Chemicals required for operation of RO plant will be measured and paid seperately under Schedule 'A' Part - III (b) RO Plant shall be maintained for smooth functioning and for out put capacity of drinking water not less than 40,000 liters / per day.
PART-III Material and labour for overhauling and including replacement of minor spare parts of submercible pump of installed at Vandana and Vishakha complex complete all as specified and directed by Engineer-in-Charge.
Supply only Antiscalant chemical (Make : Aquachem /Acqua filtron/GE )
Supply only cleaning Chemical (Make: Aquachem/Agua pure/GE )
Disconnecting and taking out unserviceable multiple valve and supply fix with new multiple valve of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge. Make :- DEWS Aircon / Flow Max / Initiative
Disconnecting and taking out unserviceable cartridge filter and supply fix with new cartridge filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Disconnecting and taking out unserviceable carbon filter and supply fix with new Carbon filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Taking out old unserviceable membranes and supply & fix new Reverse Osmosis membrane all as specified and directed by Engineer-in-Charge. Make: Hydranautic/GE/ DOW/CSM
Disconnecting and taking out unserviceable Bore well submersible pump 3.0 HP and supply fix with new Bore well submersible pump horizontal type 3.0 HP capacity,Three phase,2880 rpm,50hz,head-80.5 meter, discharge-1.11 lps complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge. Make:KSB/CG/Kirloskar
Disconnecting and taking out unserviceable induction motor of 1.5 HP and supply fix with new induction motor of 1.5 HP Capacity, 3 phase,2860 rpm,50 HZ,415 Volts,Head range 35-50 meter complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.Make:Texmo/CG/Kirloskar
Disconnecting and taking out unserviceable open well submersible pump 1.5 HP and supply fix with new open well submersible pump horizontal type 1.5 HP capacity,single phase,2880 rpm,50hz,head-30 meter,discharge-3.42 lps complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.Make:KSB/CG/Kirloskar
Disconnecting and taking out unserviceable vertical type Pressure pump with motor 5.0 HP and supply fix with new Pressure pump with motor 5.0 HP capacity,single phase, suitable for RO plant complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.Make: KSB/Crompton/Kirloskar
Disconnecting and taking out unserviceable Mono block sumersible pump of 3.0 HP and supply fix with new Mono block sumersible pump of 3.0 HP , single phase complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.Make:Texmo/CG/Kirloskar
Disconnecting and taking out unserviceable control panel and supply fix with new control panel for RO plant complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and demonstration of chlorine residual test kit portable digitally operated range 0.1-1 PPM and 0.6 to 6 PPM with enclosure & orthodin solution bottle 500 ml capacity complete all as spificied and directed.
Supply and fix in repair LT XLPE Cable on wall/floor/ceiling with proper saddles, including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core. Make: Polycab/Plaza/Havells/Finolex
Taking down old unserviceable Foot valve 80 mm supply and fix new foot valve of 80 mm dia with flange/thread type as per site requirment all as directed by engineer in charge
Supply and fix in repair Submersible Cable on wall/floor/ceiling with proper saddles, including testing of Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 4 core. Make: Polycab/Plaza/Havells/Finolex
Taking down old existing VCPVC 15mm dia pipe , supply & lay CPVC pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. of size 40 mm Make:prince/sudhakar/Ashirvad
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of cap 01 lakh ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings suitable for borewell etc. sizes of 40 mm dia:
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings etc. sizes of 25 mm dia:
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings etc. sizes of 50 mm dia:
Taking down old unserviceable sluice valve 80 mm supply and fix new sluice valve 80 mm with wheel make: kirloskar/kartar/BIR
Disconnecting and taking out unserviceable sand core from FRP filter and supply fix with new sand core in FRP Filter of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable carbon media from FRP filter and supply fix with new carbon media for water softner in FRP Filter of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable FRP Housing of membrane and supply fix with new FRP Housing of membrane for supporting and balanceing existing membrane of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
M & L for Rewinding of unserviceable induction motor of 1.5 HP capacity 3 phase 50 Hz 415volt complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
Repair /replacement of old rusted semi undernground sump ladder . Supply and fixing iron ladder made out of angle iron 50 x 50 x 6 mm thick and 16 mm bar for step as per exising size and fixing to botton and top of the sump & welding , cutting , charge incuded all as directed by Engr- in-Charge
Taking down old u/s PVC tank and Supply and fix PVC moulded water storage tank of 7500 Ltrs capacity cylindrical vertical type complete with inlet, outlet, overflow, and wash out connection, closed top cover complete including hoisting in position etc all as specified and directed by Engineer-in-Charge. Make Sintex/ Infra/ Polycon
Taking down old unserviceable and broken PVC tank from G + 15 top of the building and fixing new tank the same position same location and fixing all out going and incomming pipes directed by engr -in-charge. Note : PVC tank of capacity will be paid and measured seperately under respective schedule.
Supply & fixing in replacement of dosing Pump high pressure single head gear motored adjustable dosing pump with accessories include lead tubing, connecting nuts, injection check valve, clay weight, ferules etc. Make Aquafit /Declibac or equvilent make approved by GE.
Supply only Calcium Hypochlorite in granular form in 45 Kg drum, having minimum 70% of available chlorine (Ca(OCI)) with anti-corrosive and anti-scaling properties suitable for human consumption. Make: PuriChlor (SRHSH). Note: Contractor shall produce letter of authorisation, COA with unique serial number and NSF certiifcate from manufactuer. Make Aquafit/Decliback/Purichlor
S&F HDPE of pressure rating 6kg/cm sq pipe of 110 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Make : Suprime /Prince or equivalent approved by GE
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Taking down old rusted pipe . Supply and fixing GI tubing 80 mm dia medium grade with all fitting such as tee, socket, bend, union etc in trenches complete. Make : TATA/Jindal/Zenith/surya prakash
Part -I Manning & operation of Central AC Plant two in number 32.5 TR make Kirloskar run at a time one compressor and one stand by for smooth functioning of entire system and to maintain the specific temperature 20+2ºC, RH 50+5% AC plant consists of the following items fitting/ fixtures/ device components for operation at Epoxy coating workshop boat pool 8hrs daily except Sunday and Holiday in one shift.(i.e 0800 To 1600 Hrs) one AC plant operator per shift and taking care cleaning etc any pilferage, theft or damage etc complete all as directed:- (a) Compressor make Kirloskar -02Nos. (b) Compressor motor HBB 50HP-02Nos. (c) Condenser water pump set mono block 7.5HP - 02 Nos. (d) Air handling unit with blower motor 10HP-01No. (e) AHU motor 10HP HBB-01No. (f) Cooling tower induced draft type -01No. (g) Electrical control panel cubical type floor mounted with maint switch MCBs voltmeter, Ammeter, Starter condenser etc. complete-01Set. (h) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cuts out with panel board installed gauges-01 Set (j) Digit type thermometer-01Set (k) Air supply duct with grill diffusers, dampers and heater etc. complete-01Set (l) Condensor MS piping 100mm with valves, pressure gauge, temperature gauge complete-01Set
Manning & operation of Central AC Plant of water cooled chillers 3Nos. x 50 TR (Two running,one standby) Total 150 TR make: voltas for smooth functioning of entire system and to maintain temperature of AC plant consists of the following items fitting/ fixtures/ device components for operation at INS SHIKRA . 16 hrs daily including Sunday and Holiday in two shift.(i.e 0600 to 1400 Hrs,1400 to 2200 Hrs ) one AC plant operator per shift and taking care cleaning etc any pilferage, theft or damage etc complete for the following:- (a) Compressor model No. ACCWC05000MNT-03 Nos. (b) Compressor motor 60HP-03Nos (c) Condenser / chiller water pump set mono block 10/7.5HP-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan-01No. (f) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (g) Digit type thermometer-01 Set. (h) Air supply duct with grill diffusers dampers and heater etc. complete-01Set. (j) Condenser piping MS 100/80/50mm dia with valves, pressure gauge, temperature gauge -01Set
PART-II Comprehensive maintenance of Central Air conditioning Plant of capacity 32.5TR X 2Nos comprising of following equipment mentioned under including cleaning, securing, gearing the merable parts of pump motors and painting of plants motor, cooling towers and pipes, cleaning of cooling tower etc complete all as specified and directed by Engineer-in-Charge at Boat Pool Workshop:- (a) Compressor make Kirloskar -02Nos. (b) Compressor motor HBB 50HP-02Nos. (c) Condenser water pump set mono block 7.5HP - 02 Nos. (d) Air handling unit with blower motor 10HP-01No. (e) AHU motor 10HP HBB-01No. (f) Cooling tower induced draft type -01No. (g) Electrical control panel cubical type floor mounted with maint switch MCBs voltmeter, Ammeter, Starter condenser etc. complete-01Set. (h) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cuts out with panel board installed gauges-01 Set (j) Digit type thermometer-01Set (k) Air supply duet with grill diffusers, dampers and heater etc. complete-01Set (l) Condensor MS piping 100mm with valves, pressure gauge, temperature gauge complete-01Set
Comprehensive maintenance inclduing Sundays & Holidays of central AC plant of water cooled chillers 3Nos. x 50 TR (Two running,one standby) Total 100 TR make: voltas, model No. AC WC05000MNT at INS SHIKRA complete with cooling tower AHU & other accessories for for the following:- (a) Compressor model No. ACCWC05000MNT-03 Nos. (b) Compressor motor 60HP-03Nos. (c) Condenser / chiller water pump set mono block 10/7.5HP-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan-01No. (f) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (g) Digit type thermometer-01 Set. (h) Air supply duet with grill diffusers dampers and heater etc. complete-01Set. (j) Condenser piping MS 100/80/50mm dia with valves, pressure gauge, temperature gauge -01Set.
PART-III Material and labour for pumping down and transfer existing refrigerant gas of compressor complete for over hauling of compressor, reciprocating open type Model No. AC- 470 Make:Kirloskar 32.5Ton capacity and dismantling complete assembly & replacing of minor unserviceable parts including matching of crank shaft boring polishing etc. replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required, maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge at Epoxy work shop Boat Pool. Note: (Major spare parts, compressor oil and refrigerant for topping up will be measured and paid seperately herein after as supply only).
Material and labour for pumping down and transfer existing refrigerant gas of compressor complete for over hauling of compressor, reciprocating open type Model No. 5H20 Make:Voltas 50Ton capacity and dismantling complete assembly & replacing of minor unserviceable parts including matching of crank shaft boring polishing etc. replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required, maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge at INS Shikra. Note: (Major spare parts, compressor oil and refrigerant for topping up will be measured and paid seperately herein after as supply only).
Supply only following items for compressor reciprocating model No AC-470. Make :- Kirloakar 32.5 ton and compressor reciprocating model No.5H20 Make :- Voltas 50 ton capacity
Main bearing
Liner assembly
Piston rings
Piston Oil rings
Piston pins
Suction valve reeds
Suction valve reed springs
Discharge valve reeds
Discharge valve reed spring
Discharge valve guide assembly
Connting Rod
Oil filter inner/ outer
Discharge valve retaining plate
Piston
Oil regulating valve
Connecting rod bearing of two
Loading/ unloading valves
Loading/ unloading rings
Crankshaft
Oil pump Assembly
Oil pump bush
Solenoid coil valve assembly
Taking down old unserviceable shaft seal assembly complete and supply and fix new shaft seal assembly suitable for 32.5 TR capacity central AC Plant all as directed by Engineer-in-Charge
Taking down old unserviceable shaft seal assembly complete and supply and fix new shaft seal assembly suitable for 50TR capacity central AC Plant all as directed by Engineer-in-Charge
Material and labour for expansion valve of AC plant capacity 32.5TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Boat pool. Make : Sporlon or equivalent
Material and labour for expansion valve model no- MV-52 of AC plant capacity 50TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Boat pool. Make : Sporlon or equivalent
Material and labour for pumping down the plant to preserve the existing in refrigerant gas & leak testing of plant by charging of nitrogen gas in to entire plant & monitoring for 24hrs to find the leakages, rectification of leak by brazing & replacement of necessary gasket packing wherever required including copper tubes of suitable size vacumising of the plant by vacum pump & keeping 24hrs for testing including rectification of leakages if any finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure complete testing of the plant for smooth functioning complete all as specified & as directed by Engineer-in-Charge.
Dismantling AHU of 3 x 50TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at INS SHIKRA.
Dismantling AHU of 2 x 32.5TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at INS BOATPOOL.
Removing the unserviceable liquid line valve of size 25mm dia from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 25mm dia including connected works as required for smooth functioning of AC plants complete all as specified and directed by Engineer-in-Charge
Material and labour for dismantling FRP cooling tower of capacity 50x3 TR at INS Shikra by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed
Taking out old unserviceable cooling tower fills sheets of 3X50 TR from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed at INS Sikra AC Plant
Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for 3x 50 TR Mihir make cooling tower as per existing at INS Shikra
Material and labour for disconnecting condenser for descaling, plugging them & providing of 15mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7flush with fresh water mixed with sodium carbonate tubes and cleaning with nylonbrush after closing the end covers, circulating diluted acid solution as specified above, to maintaine PH value as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge.
Replacement of Compressor Oil with new Compressor oil of Frizol 68 all as specified and directed by Engineer-in-Charge.
Removing old unserviceable discharge valve 25mm dia and supply and fix new discharge valve of size 25mm dia suitable for R-22 gas discharge line all as specified & directed.
Supply and fix in replacement of unserviceable / wornout 'V' belt of compressor, AHU etc of make fenner Dunlop / Nurlon as approved
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 125 mm dia
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 100 mm dia
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 80 mm dia
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 100 mm dia:
Removing the unserviceable solenoid valve 5/8" flare from the liquid line and supply and fix new solenoid valve 5/8" suitable for AC plant of various capacities complete with all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs CI Butter fly valve slim seal design with nitrile rubber lined seal with clutch lever (P10 or PN 16) as per IS 13095 of size 125 mm bore .Make: AUDCO/SANT/SIR as approved.
Ditto - as per item No 67 above but 100 mm bore.
Ditto - as per item No 67 above but 80 mm bore.
Ditto - as per item No 67 above but 65 mm bore.
Taking down old unserviceable Non Return valve and supply and fix new CI Non Return valve of size 100 mm Bore. Make: -Kirloskar /Kartar/Zolota/Leader as approved
Ditto - as per item No 71 above but 80 mm bore.
Ditto - as per item No 71 above but 65 mm bore.
Taking down old unserviceable Strainer of any make and size and supply and fix new Strainer of size 100 mm Bore.Kirloskar /Hammer/Zolota/Leader as approved
Ditto - as per item No 74 above but 80 mm bore.
Supply and fix Condensor safety valve suitable for chiller unit all as specified and directed by Engineer-in-Charge.
Removing old unserviceable over load relay assembly and supply fixing new overload relay assembly of same make and capacity all as directed.Make: L & T or its equivalent
Removing old unserviceable timer and supply & fix NewTimer of L&T make for Condenser motor all as specified & directed.
Supply and charge refrigerant Gas as per requirement.
Removing old unserviceable power contactor and supply & fix new power contactor 3TF-47 all as specified & directed by Engineer-in-Charge Make : Siemens or equivalent
Removing old unserviceable power contactor ML-2 and supply & fixing new power contactor ML-2 all as specified & directed.Make:L&T/Siemens/BCH
Removing old unserviceable power contactor ML-3 and supply & fixing new power contactor ML-3 all as specified & directed. Make:L&T/Siemens/BCH
Removing old unserviceable Auxilary contactor and supply & fix new Auxilary contactor all as specified & directed by Engineer-in-Charge. Make : L & T or equivalent
Removing old unserviceable power contactor and supply & fix new power contactor MNX -32 all as specified & directed by Engineer-in-Charge Make : L & T or equivalent
Removing the unserviceable pressure gauges HP/LP/OP from existing position and supply and fixing new pressure gauge of capacity 0 to 30Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Removing the unserviceable water pressure gauges from water line & supplying and fixing new water meter up to pressure 0-7Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 32.5 x 2 TR (65TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 50 x 3 TR (150TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Material and labour for cleaning complete DX type cooling coil of AHU with chemical solution caustic soda to remove impurities dust and foreign materials, complete with nylon brush and cleaning cooling coil with fresh water complete all as specified & directed for the cooling coil section of AHU of 3x50 TR Capacity AC plant at Boatpool Workshop.
Material and labour for disconnecting for Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure of 3x50 TR capacity at INS Shikra ACplant complete all as specified & directed by Engineer-in-Charge.
Material and labour for repairs to Microprocessor of 50 TR Capacity chiller unit including replacing diods , transistors and wiring etc for AC Plant at INS SHIKRA all as specified and directed
Material & Labour for LP/HP/OP cut out KP-1 Including taking down old one. Make:- Indofoss
Removing the unserviceable solenoid coil and Supply and fix new solenoid coil suitable for AC plant of various capacities complete with all as specified and as directed
Removing the unserviceable chiller water sensor and supplying and fixing new chiller water Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Removing the unserviceable pressure Sensor HP / LP / OP from and supplying and fixing new pressure Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Supply and errect factory fabricated rectangular square duct made out of 24 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable insulation from any surface and supply and fix nitrile rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape all as directed by Engineer-in-Charge.
Taking out old unserviceable AHU body & supply and fixing of factory fabricated double skin powder coated GI sheet of 21 gauge, 43 mm thick puf insulated CFC free for AHU body including proper door handles, corner supports cutting, bending, welding/ brazing/ wooden work/ structural support all as specified and directed by Engineer-in-Charge
Supply and fix in repairs DX type cooling coil made out of copper of any size and any rows suitable for 30000 CFM AHU unit complete all as specified
Supply and fix in repairs centrifugal fan blower set backward curved fan 640 RPM having velocity 8.84 M/Sec including drum and shaft absorbing power 9.6 KW along with anti-vibration spring isolators for minimizing vibrations (Blow/draw through type) suitable for 30000 CFM of the AHU unit all as specified and directed.
Supply and fix in repairs TEFC squirrel cageIP-55 protected VFD compatible induction motor of capacity 11 KW ,3 phase, 415 volts, 50 Hz ,1450 RPM suitable for 30000 CFM AHU unit and fixed on AHU base plate with suitable size nuts, bolts, washers including making electric connections of motors, earth connections with suitable size copper conductor cables, suction and delivery pipes connections complete all as per manufacturers instructions. Make:- Kirloskar/CG/NGPE complete all as specified
Taking down old unserviable diffusers / grill and supply and fix new suppli air diffusers / grill made of aluminum powder coated with damper as per existing size 0.75mtr x 075 mtr .
Taking down old unserviable Fire damper and supply and fix new Fire damper made out of GI sheet 16 G with fusible plug as per existing size 0.45mtr x 0.45mtr
Supply and fix in repairs volume control damper made out of galvanized iron or anodized aluminium with overlapping leafs to avoid any leakage from the damper suitable for AHU as per existing at site complete all as directed by Engineer-in-Charge of size 0.45mtr x 0.45mtr
Supply and fix in repairs leather type canvas in AHU duct of any size as per existing of size 1.50mtr length & 0.15cm dia.
Taking down old unserviceable AHU pre filter and Supply and fix new pre filters (EU-4)synthetic non oven type efficiency 90% down to particular size of 10 micron double knitted twisted polymer fabric (washable) rated with press drop of 6 mm WC to be mounted in AHU filter assembly size as per existing. Make: ASPAWYMAN/DYNA/MHP as approved
Material and labour for framed work with structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as directed including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Material and labour for dismantling FRP cooling tower of capacity 50x3 TR at INS Shikra by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed
Material and labour for dismantling FRP cooling tower of capacity 1x32.5 TR at Boat pool by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed
Taking out old unserviceable cooling tower fills sheets from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed
Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for cooling tower as per existing
Maintenance and Labour for complete overhauling of Air Compressor having Model No-22526259-80, Make: ATLAS COPCO and motor of 150H.P Capacity along with associated fittings and following mentioned as under all as specified and directed by EIC at integrated Boat centre Boat pool workshop (i)Dismantling, removal, overhaul, repairs and reassembly of twin screw compressor.(ii)Dismantling, and inspection of bearings and seals, replacement as required .(iii)Dismantling, overhaul and assembly of compressor drive motor (150HP)(iv) Dismantling & overhaul of compressor deliver valve.(v)Dismantling, cleaning of tubes, reassembly and testing of lubricating oil cooler.(vi)Dismantling, cleaning of tubes, reassembly and testing of discharge air cooler.(vii)Dismantling , cleaning, and testing of oil and water seperator.
M&L for Cleaning of Air handling ducts internally by using special T&P like robortic arm, air compressor, air jet nozzles, flipper, vaccum pump and a suction blower with hepa filter and check before and after the cleaning complete all as specified and directed
Rewinding of unserviceable electric motor 3 phase 50 Hz 415volt of following capacity pump set complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
(a) 20 HP Chiller Water Pump Motor .
(b) 15 HP Condenser Water Pump Motor.
(c) 5.0 HP Condenser Water Pump Motor.
(f) 40 HP Compressor Motor .
(g) 60 HP Compressor Motor .
(g) 10 HP AHU Blower Motor .
Over hauling of Monoblock pump set after removing from the base plate, disconnecting from pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacity of pumps and motors:-
(a) 20 HP Chiller Water Pump
(b) 15 HP Condenser Water Pump
(c) 5.0 HP Condenser Water Pump
Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)
M& L for Removing old burnt Transformer oil and Supply and toping of transformer oil with 50KV di-electric strength complete all as specified. Make: Power /Asian/Savita/Electric.
M&L for Dismantling of Damaged Breather and Supply and fixing in repair of breather with 500 Grams celica gel of indoor type transformer 300KVA TO 740 KVA, all as specified and directed by Engineer-in-Charge.
M&L for Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
Material and labour for Spray Painting of Transformer of following capacity,indoor type with Two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities complete and all as specified and directed by Engineer-in-charge.
Transformer 500KVA TO 740 KVA 11 KV /433Volt
Transformer 400KVA ,11KV/433Volt
Transformer 300KVA/200KVA ,11KV/433Volt.
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Transformer 500KVA TO 740 KVA,11KV/433Volt
Transformer 400KVA ,11KV/433Volt
Transformer 300KA/250KVA ,11KV/433Volt
Dismantlin of old damaged Cooling Fins and upply and fix in repair cooling fins of transformer of capacity 400/500 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Material and labour for loading into truck of faulty Transformer of capacity 250 KVA to 740 KVA with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
Material and labour for loading into truck of Transformer capacity 250KVA to 740KVA after carying out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting it inside the sub station and connecting all HT and LT cable connections and earthing connections complete all as specified and directed.
Material and labour for Dismantling the Core and taking out along with windings and cleaning oil tank of transformer 250 to 740KVA, 11KV/415Volts and removing sludges from tank, manufacturers specifications and standard practice complete all as specified and directed. (Note: Transformer Oil will be measured and paid seperately).
Material and Labour for Dismantling the faulty HV winding carefully from transformer of any type and capacity11KV/433Volts from core and rewinding the HV winding with suitable size of insulated copper wire as per manufacturers specifications and standard practice complete all as specified and directed.
Material and Labour for Dismantling the faulty LV winding carefully from transformer of any type and capacity,11KV/433Volts from core and re winding the LV winding with suitable size of insulated copper wire and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the HV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the LV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for refixing the core and windings assembly with insulating material and hardware of Transformer of any capacity and type,11KV/433Volts in to the oil tank with suitable fixing arrangements and re connecting HV and LV internal connections to HV and LV bushings and replacing gaskets of bushings,bottom and top valve, top cover, conservator and replacing celica gel breather and fixing top cover with conservators and reassembling all parts respect to original position and refilling of new transformer oil and filler to achieve the BDV Values and testing as per manufacturers specifications and standard practice complete all as specified and directed. (Note: transformer oil will be measured & paid seperately)
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type OCB trolly of rupturing capacity 250 MVA, 400 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts and new transformer oil shall be measured & paid seperatly) .
(i) Inspecting/overhauling of spring drive mechanism by checking mechanism, hold on catch assembly,trip bridge, z srew, Cam U, Aluminum trip bridge, Main trip lever assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of OLTLF assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling / cleaning and inspecting insulators, moving contacts ,fixed contacts,arcing chamber by carbon cleaner solution and apply dry graphite conductive sealant for contacts to avoid carbon deposits on contact surfaces. (iv) Inspecting/Cleaning of oil tank inside and out side surface by CRC throughly and replacement of transformer oil (60 litre for each OCB) and apply heavy duty grease for tank raising/lowering guide. (v) Assembling all items/components parts to the respective position & testing the breaker with High Voltage and Meggering before and after high voltage test complete.
Material and labour for painting of HT OCB capacity 250/350MVA,11KV, 400Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB all as per specified and as directed by Engineer-in-charge.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.)
(i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB and all as specified and as directed by Engineer-in-charge.
Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge. (Note: spare parts shall be measured & paid seperately.) :-
M&L for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge.
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB,ACB, measured and paid separately under relevant items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers. (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job. (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job. (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job. (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately)
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric FBB in door type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter /Ampermeter/CT/LED lamps of any type and discription etc and refixing the same,which shall be measured and paid as supply only under relevant items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately) (viii) Re welding of Doors with new Injus
Supply & fixing Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size with insulation sleeve complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply and fixing of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium bars, for cable terminations, duly fixed in the body of the panel board by and including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed.
Material and labour for repairing of Capacitor (APFC ) panel of 100KVAR to 250KVAR and carryout repairs as (i)Dismantling of Power contactor,TP,415Volts and auxiulary contactors and cleaning,Overhauling,servicing ,repairing thoroughly and replacing burnt contactors upto 63Amps including suitable capacity of copper wire single core,1100Volts grade -01 Job (New contactors will be measured & paid separatly)
Supply & fixing power pack ,230V AC input, 30V DC /110Volt DC out put suitable for VCB/OCB 11 KV as power back complete all as specified and as directed. Make : Alan/CG/Areva
Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare parts suitable for - VCB 11 KV , 630 amps indoor type of Make Schnieder/Siemens//CG complete all as specified and directed by Engineer-in-Charge.
Opening / Closing Push Button Assembly
Motor Charding mechanism gear box
Limit Switches
Closing Coil Assembly
Tripping Coil assembly
Spring Charging Motor
Auxiliary Switch with link
Spring return latch
Vaccum Interupter assembly
Spout Insulator assembly feeder side
Spout Insulator assembly Bus bar side
Potential Transformer,11KV/110Volt/Rout3,100VA burden Trolly mounted with HRC Fuse
Current Transformers,50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec
TNC Switch
Indicating Lamps red, white, blue, yellow 24/110V DC LED type
Vaccume insulator bottle
Dismantling of old burnt Spout insulator and Supply and fixing of spout insulator assembly for HT OCB 11 KV , 400 amps indoor type with current carrying parts complete all as specified and directed by Engineer-in-Charge.
Dismantling of old burnt through insulator and Supply and fixing in repair of OCB through insulator assembly with current carrying parts for OCB, 11KV, 400Amps, indoor type and complete all as specified and directed.
Supply and lay electrical LT insulation rubber matting as per ISI of size 1m x 2m x 19 mm thick. Make : Jaipuria Brothers
Cutting and removing grass, vegetation bushes etc from surrounding all installation roof and removing all rubbish to a distance not exceeding 50 m as directed.
Dismantling of old burnt gasket and Supply and fixing in repair of OCB oil tank gasket 3mm thick suitable for OCB, 11KV, 400Amps, indoor type complete all as specified and directed.
Dismantling old burnt Heaters and Supply & fix in repairs strip type heater 80watt with control wiring suitable for indoor OCB/VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately)
Dismantling of old damaged power factor Meters. Supply & fixing Digital power factor meter and all as specified and directed. Make:AE/MECO or equivalent make approved by GE
Dismantling of old damaged Lamps and Supply & fixing in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make:Teknic/ C&S /L&T
Dismantling of old damaged/burnt ACB with Bus Bar and Supply , fixing ,testing and commissionning in repair in existing panel electric moterised charced ACB. 4Pole, 630 Amps ,MDO ,50KA suitable for 415V, 3phase, AC supply including necessary modification in panel with 2mm thick CRCA sheet door and suitable size of Copper bus bar and all specified and directed. Make : Schneider/L&T/C&S/Havells/HPL / Legrand.
Dismantlin the old damaged Relay and Supply and fixing APFC Relay, 12Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed. Make - L&T/ Syntron/Sycon
Dismantling the Old damaged Caoacitor Bank and Supply and fixing Capacitor 5KVAR, Heavy duty type,415Volts,50Hz AC supply in existing panel complete as specified and directed by Engr-in-charge. Make: Prabodhan/Epcos/Havells/Schnieder
Ditto all as per item No.46 but of rating 10KVAR
Ditto all as per item No.46 but of rating 15KVAR
Ditto all as per item No.46 but of rating 20KVAR
Ditto all as per item No.46 but of rating 25KVAR
Dismantling of Old Damaged Contactor and Supply and fixing Power contactors Capacitor Duty(Type MOC of L&T) 50Amps Capacitor duty with 2NO+2NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder
Ditto all as per item No.51 but rating 40Amps
Ditto all as per item No.51 but rating 32Amps
Dismantling of old damaged MCB and Supply and fixing in repair of MCB,TP,C'Curve,63 Amps,415Volts,50Hz AC supply in existing panel with mounting rail complete all as specified and directed by Engr-in-charge.
Ditto all as per item No.54 but rating 40Amps
Ditto all as per item No.54 but rating 32Amps
Ditto all as per item No.54 but rating 20Amps
Dismantling of Old Damaged Contactor and Supply and fixing Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Dismantling of Old Damaged timer and Supply and fixing Time delay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Dismantling of Old Damaged CT and Supply and fixing Current Transformers,415V 600/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Dismantling of Old Damaged CT and Supply and fixing Current Transformers,415V 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : Make : AE/NSDA/MECO/C&S
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for HT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 11KV gradecomplete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge. Make – 3M/Denson/Raycham
Material labour for HT Cable Jointing work by Cutting the faulty cable and making END TERMINATION JOINT for 11KV grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 90 to 185 sq mm and all as directed by Engineer-In-Charge. Make – 3M/Denson/Raycham
Supply and laying HT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 185Sqmm 3 core and all as directed by Engineer-In-Charge.Make: Polycab/Havells/Nicco/Gloster
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 16 to 25 sq mm and all as directed by Engineer-In-Charge. Make: 3M/Raychem/Denson
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 35 to 50 sq mm and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge.Make : Polycab/Finolex/Havells/Gloster
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
S&F HDPE of pressure rating 6kg/cm sq pipe of 90 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Make : Suprime /Prince or equivalent approved by GE
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make : Polycab/Finolex/Havells/Gloster
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and labour for fixing angle Iron of size 25x25x6mm size and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/ACB'S/Changeover switc/Lugs.will be measured and paid separately)
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,630 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ Schneider/ABB./Havells
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,400 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ Schneider/ABB./Havells
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,315 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ Schneider/ABB./Havells
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,250 Amps,25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ Schneider/ABB./Havells
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,160 Amps,25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ Schneider/ABB./Havells
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,100 Amps,16kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ Schneider/ABB./Havells
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole, 250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge. Make : Legrand /Seimens/ L & T ./Havells
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 300Sqmm to 240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 185Sqmm to 150Sqmm -240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 95Sqm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 70Sqmm to 50Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 35Sqmm to 16Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 10Sqmm to 4Sqmm complete all as specified and directed by Engr-in-charge.
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in HT Panels Boards/Cable Connections including HT insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Spare Parts.will be measured and paid separately)
Supply and fix of power pack ,230V AC input, 30V DC /110Volt DC out put suitable for VCB/OCB 11 KV as power back complete Make : Alan/CG/Areva
Supply & fix in repairs strip type heater 80watt with control wiring suitable for indoor OCB/VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
Cutting metal road/hard standing for laying of cable and re metaling/making good the same to match the existing surface complete all as directed by Engr incharge.
Servicing of diesel engine of 125 KVA at INS Shikrs Power house,repair/replacement of the following components including opening engine and replacing all gaskets complete all as specified and directed by Engr-in -charge
(a) Cylinder head gasket to be repaire
(b) Element LO filter with O ring 1 set.
(c) Element fuel filter with O ring -1set
(d) Filter screen - 2 set
(e) Element air cleaner 1 No
(f) Element Bypass filter with O ring 1 No.
(g) All fuel,oil,and coolent and head need to be changed.
(h) Checking water temperature safety control
(j) Checking and correcting up impeller of water pump for excess play.
(k) Checking and correcting turbocharger oil leakage, tightening of mounting screws and nuts
(l) Cleaning, tightening all electrical connection of engine
(m) Checking generator brushes (Alternator) and commutator and replacing the brushes.
(n) Cleaning of entire engine.
(o) Checking exhaust and inlet manifold bolts and cap screw
(p) Checking engine blow by.
(q) Cleaning of radiator inside and outside by removing and refixing after cleaning.
(r) Checking and adjusting injector and valves.
(s) Cleaning fuel inlet connections and screw,
(t) Changing of governor oil.
(u) Replacing of radiator hoses of different sizes with clamps
(v) Checking of vibration damper.
Removing the old engine oil from the diesel engine sump of various DG sets, cleaning the oil sump thoroughly, supply and fill new engine oil of make Servo super 20W40 of Indian oil or equivalent grade of Hindustan Petroleum as directed by Engineer -in -Charge.
Repair/overhauling of self starter including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch, carbon brushes, brush spring etc. for the following DG Set.
Supply and replace PVC insulated battery lead of suitsble size with copper conductor cable of length 1.5 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete as specified and as directed.
Cleaning of the fuel tank of the following capacity DG sets after decaning the diesel, painting with one coat of approved colour synthetic enamel paint after thorough cleaning and preparation of surfaces, marking of fuel level gauge, fuel tank cap, writing of tank capacity
Supply and fixing 12 Volt 180 AH battery with 24 plates , liquied immersed and fully charged Make- -Exide/Amron
Checking the serviceability of any capacity DG set per month and rectified the minor repair as directed by Engr-In-Charge
Taking down burnt DG auto panel contactor . Supply and fixing in Replacement of DG auto panel contactor 04 pole MCX 33 AC-1:200A, Coil - 415 Volt 50 HZ and Auxilury contact - 2NO + 2NC Make : L & T / CG/Schneider
Taking down burnt DG auto panel contactor . Supply and fixing in Replacement of DG auto panel contactor 04 pole LC1D15004, Coil - 415 Volt 50 HZ and Auxilury contact - 2NO + 2NC Make : L & T / CG/Schneider
S&F HDPE of pressure rating 6kg/cm sq pipe of 63 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Suprime /Prince or equivalent approved by GE
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (using 20mm graded stone aggreagate) for base of pole including use and wste of form work complete all as specified and directed by Engineer-in-Charge.
Airef Engineers Pvt Ltd
Darpan Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .