Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹31.4 L+₹66,665.02 (2.17%)Rejected-Finance | L2 | Rejected-Finance Rejected being L 2 | |
| 3 | L3₹32.9 L+₹2.2 L (7.23%)Rejected-Finance | L3 | Rejected-Finance Rejected being L 3 | |
| 4 | L4₹40.0 L+₹9.3 L (30.2%)Rejected-Finance | L4 | Rejected-Finance Rejected being L 4 | |
| 5 | L5₹40.3 L+₹9.6 L (31.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being L 5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Aug 2020, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR / MAINT / REPLACEMENT OF INTERNAL ELECTRIFICATION WITH FITTING AND FIXTURES AT BASE HOSP, SOI, PD AND SURYA AUDITORIUM AND DOMESTIC COOLING APPLIANCES IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2020_MES_358466_1
GE/EM/LKO/HOSP/T-32 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category b (i), c (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹90,000
Yes
1 Oct 2020
4 Jul 2020
3 Aug 2020
4 Jul 2020
1 Aug 2020
20 Jul 2020
Amount
Supply and fixed in repairs of starting capacitor of 80-100 /100/120/120/150 Mfd capacity in plastic / metal container all as directed.
Supply and fixed in repairs of running capacitor 36 Mfd capacity in plastic container all as directed.
Supply and fixed in repairs of running capacitor 50+2/50+6 Mfd capacity in plastic container all as directed.
Supply and fixed in repairs starting relay for 1.5 TR /2 TR compressor all as directed.
Supply and fixed in repairs over load protector for 1.5 TR / 2TR compressor all as directed.
Supply and fixed in repairs Thermostate switch for 1.5 TR / 2 TR split AC all as directed.
Supply and fixed in repairs Swing Motor for 1.5 TR / 2 TR Indoor unit all as directed.
Supply and fixed in repairs reverse cycle solenoid valve in split/window type AC 1.5 /2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as directed.
Supply and fixed in repairs suction copper pipe line heavy duty ½'' dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
Supply and fixed in repairs discharge copper pipe line heavy duty 1/4" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 TR 2 TR capacity all as specified and directed.
Supply and fixed in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as directed.
Dismantling of defective condensing unit of split type AC of 2 TR capacity and supply & fixing new condensing unit complete with condensing coil, coil frame, wiring kit and running capacity, relay condensing motor with blade complete all as directed.
Material & labour for servicing of indoor and outdoor unit of 1.5 TR /window type of capacity AC by means of electric blower and water under pressure cleaning & washing of condensing coil / cooling coil by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc. complete all as specified and directed.
All as per item No. 14 above but 2 TR capacity
Dismantling of burnt blower motor of 1.5 TR /2 TR split AC ( indoor unit) and supply & fixing blower motor of same manufacturer of AC of Make of AC Carrier/Voltas /Blue star as per sample complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required Qty complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas non CFC compatible to R- 710 type or as eqvlnt in required Qty complete all as specified and directed.
Supply and fixed in repairs of suction valve size 1/2" complete all as specified and directed .
Supply and fixed in repairs of discharge valve size 1/4" complete all as specified and directed.
Supply and fixed in repairs of air filter made out Nylon suitable for 1.5 TR split AC capacity air conditioners of any Make and model all as directed.
Supply and fixed in repairs of air filter made out Nylon suitable for 2 TR split AC capacity air conditioners of any Make and model all as directed.
Carrying out pressure leak test of split ACs 1.5 / 2.0 TR by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site all as specified and directed.
Carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site all as specified and directed.
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR /2TR 3 TR including unserviceable corded electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit /match the existing system all as specified and directed.
S&F Compressor rotary suitable for reversible cycle split type AC 1.5 TR (Original sealed unit is to supply ) of Make Blue Star, Videocon, Samsung, or its equivalent of other specified make as approved by GE.
S&F Compressor rotary suitable for reversible cycle split type AC 2.0 TR (Original sealed unit is to supply ) of Make Blue Star, Videocon, Samsung, or its equivalent of other specified make as approved by GE.
S & F in repairs sheet metal enclosure with metallic socket and MCB single pole 32 Amp and metallic plug top connected from mains to AC all as specified and directed .
S & F repairs metallic plug top of 16 Amps connected from mains to AC all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR/ 2 TR window AC and supply & fixing new blower motor, double shaft, 1/6 or 1/8 HP as per sample complete including making necessory electrical connection with suitable size copper conductor wire all as specified and directed.
Supply and fixed in repairs of aluminium blower / fan blade with alminium alloy bush, screw for window ACs complete as required at site complete all as directed.
Supply only PVC knob of window type AC complete all as specified and directed (Make :- LG /Carrier /Voltas).
Supply and fixing in repairs front grill quantity for window AC of 1.5 TR /2TR of Make National / Cosmo all as specified and directed.
Supply and fixed in repairs of mild steel stand factory fabricated made out of MS sheet 18 gauge floor/wall mounted, duly powder coated including nuts ,bolt, washer, fastners etc suitable for mounting of out door unit of split AC 1.5/2.0 TR at locations as directed.
Dismantling of indoor/out door unit of split type A/Cs of 1.5/2.0 TR capacity from their original locations and shifting it to other locations including servicing/overhauling of indoor/out door units,top up of refrigerant gas as required quantity and refixing it to locations where directed and making necessory electrical connection/connecting copper tubing of suction/discharge line and testing it upto entire satisfaction of Engineer-in-charge.
Dismantling of defective worn out wiring of window/split AC of capacity 1.5 TR /2/3 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and remote hand set to shut /match the existing system all as specified and directed. (Make of AC and remote :- Carrier /LG -HI SERIES).
Supply and fixed in repairs of PVC insulated three core stranded copper cable of size 80/20 all as specified and directed.
Dismantling of defecting window type AC capacity 1.5 TR / 02 TR complete with connected other items and cordless remote control and repairing servicing oiling and greasing of moving parts, mounting / fittings from one place to another place/ location along with making hole into the wood / hard wood & making good disturbed surfaces and testing complete after installations all as specified and directed by Engineer-in-charge (Extra refrigerant gas and electrical accessories where will be measured and paid for separately).
Supply only of alkaline Coil Cleaner for servicing / cleaning to condensing / cooling coil of window type AC & Walk-in-cooler Make-C-Shine.
Supply only of Spray Pump with plastic container of 1000 ml capacity for servicing / cleaning to condensing / cooling coil of window type AC & Walk-in-cooler
Supply and fixing single phase preventer suitable for three phase compressor of capacity 7.5 TR complete all as specified and directed.
Supply and fixed in repairs Single phase Compact cooling fan motor assembly 230 volt 50 Hz 1/6 HP Along with guard etc for 2 TR walk-in-cooler complete all as specified and directed.
M&L for servicing of window type AC 1.5 TR/2.0 TR capacity by means of electric blower and water under pressure cleaning & washing of condensing coil / cooling coil by soap solution or recommended chemical, coiling & greasing of moving parts such as blower motor etc complete of following capacity all as specified and directed.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with with non CFC refrigerant gas matching with R-22 in required quantities and testing complete (Note:Refrigerant gas R-22 will be provided by department under Sch"B")
All as item no 45 above but refrigerator of capacity 165/286/300/310 litre capacity charging of refrigerant gas R-22/R-134 all as specified and directed
S&F in repairs starting relay, open type for refrigerator of capacity 190/300/310 litres all as directed.
S & F in repairs of over load protector for 1/6 HP refrigerator of capacity 190/300 /310 litres all as directed.
S & F in repairs thermostat defrost type for refrigerator complete all as directed.
S & F in repairs door gasket for refrigerator of 165 / 170 / 180 litres capacities, any make all as directed by Engineer-in-Charge.
All as per item No. 50 above but 286 /300 /310 litres capacities
S & F in repairs freezer door with spring for Refrigerator of 165 / 170 / 180 litres capacities all as directed by Engineer-in-Charge.
All as per item No. 52 above but for 286 /300 / 310 litres capacities
M&L for renewal of sealed unit Compressor of FOR Compressor 1/6 TR ( 240 to 320 litres ) REFRIGERATOR) capacities duly charged with refrigerent non CFC charged complete all as specified and directed (Make-Kalvinator/ Whirlpool)
M&L for renewal of sealed unit Compressor 1/8 TR( for 165 to 210 litre REFRIGERATOR) capacities duly charged with refrigerent non CFC charged complete all as specified and directed (Make-Kalvinator/ Whirlpool)
Collection of unserviceable/defective (sealed unit original ) and charging oil/gas refrigerant after assembling and testing the other compressor complete from MES store yard of AGE E/M (Ref & AC) and transporting to shop of authorised dealer & depositing back (sealed compressor) to MES store Yard as directed by Engineer-in-Charge.
Dismantling of existing repairable water cooler of any make and capacity from its position including disconnecting of electric connections, transporting to Contractor's workshop including loading and unloding for renewal of defective parts and reassembling and transporting back to site including installation in original position and making electric connections and water supply connections complete all as specified. Note :- Parts renewed shall be measured and paid separately under appropriate item(s)).
Dismantling of worn out MS box of water cooler for accessories such as starting capacitor, running capacitor, relay etc. and supply & fixing MS box of size 150mm x 200mm x 250 mm made out of galvanised MS sheet of 22 gauge and finishing the surfaces to match with the existing complete all as specified and directed
Dismantling of top cover of water cooler of following capacity and S&F new top cover of following sizes 68cm x 61cm made out of 22 gauge GI sheet comprising CP MS handle of suitable size, PVC gasket, inner lining of glass wool of density not less than 48 kg/cum, locking arrangement, aluminium hinges etc and spray painting the top cover to match with the existing complete all as specified and directed
All as per item No 59 above but new top cover of size 72.5cm x 55cm x 3mm
Dismantling of wornout legs of water cooler and S&F new legs of size 125mm x 125mm x 150mm made out of 16 gauge sheet including welding, rivetting and reinstalling the motor after repairs complete all as specified and directed.
Supply & fixing (in repairs) CP Brass push cock (inner or outer threaded) of 15 mm bore size complete all as directed by the Engineer-in-Charge.
S&F in repairs float valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified.
Supply & fixing (in repairs) running capacitor 25 mfd (conforming to IS:2993 - 1975) AC 440 volts in plastic container complete all as specified and directed.
All as per item No. 64 above but 36 mfd
All as per item No. 64 above but 50 mfd
Supply & fixing (in repairs) overload protector for 1.00 TR compressor complete all as specified and directed .
M&L for providing angle iron stand for desert cooler/water cooler of 18"/20" size made out of 35mm x 35mm x 5mm size MS angle iron including all necessary welding and including one coat of red oxde primer including preparing of surfaces complete all as directed by the Engineer-in-Charge.
Dismantling of existing repaireable deep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor's workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. all as specified and directed by EIC :- (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
Supply and Fixing in repairs of starting relay for 190/300 Ltr. Capacity deep freezer all as specified and directed.
Supply and Fixing in repairs of starting relay for 190/ 210 Ltr. Capacity deep freezer all as specified and directed.
Supply and Fixing in repairs of over load protector suitable for 210 / 300 Ltr deep freezer all as specified and directed.
S&F in repairs of running capacitor for /190210 / 300 Ltr capacity deep freezer all as specified.
S&F in repairs of thermostate suitable for 190/210 / 300 Ltr. Capacity deep freezer all as specified and directed.
S&F in repairs of starting capacitor for 210 / 300 Ltr. Capacity deep freezer all as specified and directed.
Taking down defective compressor of 310 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar capacity deep freezer of any Make and depositing same in AGE E/M EXT(HOSP) yard and Supplying and fixing sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing complete all as specified and directed by Engineer-in-Charge.
All as per item No. 76 above but 240 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed.
Dismantling of liquid line filter of refrigerator of 190 litre capacities and supply & fixing new liquid filter , assembling of filter by replacing bolts & gasket etc complete all as specified and directed.
Taking out defective blower motor and transporting blower motor of any make and capacity 1/16 HP from AGE EM EXT (WS) AC Yard to workshop and dismanteling the burnt winding and rewinding blower motor with existing size of supper enamelled copper winding wire including insulation, varnishing, greasing and testing complete and transporting back to storeyard all as directed.
Taking down desert cooler of any size and make from existing position i.e. stand/pillar installed at any location of building(s) including making arrangements for loading/ unloading such as rope and ladders etc. for repairs and taking back after repairs & reinstalling in its position and testing complete all as directed (Note : Necessary repairs and renewal of parts will be measured and paid for separately under appropriate items(s)
Repairing of leakage of tank by brazing/soldering of any size of desert cooler, testing the leakage water complete all as directed.
S&F in repairs of PVC front grill all as directed by EIC ( Make Orient/ Anchor or equivalent of other specified make)
S&F in repairs of of control switch/dimmer electronic 600 watt all as directed.
S&F in repairs of set of panels made out of PGI sheet 22 gauge thick with wood wool pads, in required quantity duly filled complete as per sample and all as directed by EIC
Taking out defective pumps vertical/ horizontal type from desert cooler and S&F new Horizontal pump/ vertical pump of desert cooler and fixing in position all as directed. Make Bajaj/ Crompton
S&F in repairs of wood wool pad of desert coolers suitable for 450 mm/500 mm sweep complete.
S&F in repairs of desert cooler body, suitable for 400 mm/500 mm/600mm sweep exhaust fan /kit, made out of 22 gauge PGI sheet with front grill and side panel with switch regulator complete all as specified and directed. Make ;- Champion or equivalent of other specified make.
Taking out defective /perished hard board any size from window frame and S&F 3mm thick hard bed suitable for 450mm/500mm sweep desert cooler all as specified and directed.
S&F in repairs of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18" sweep size suitable for desert cooler all as specified and directed by EIC. (Make:- Jyoti / Champion / Summer Cool)
Replacing capacitor single phase A/C 250 volts for ceiling fan/kit fan motor and blower motor 2.5 Mfd
All as per item No. 91 above but 4.00 Mfd
Transporting kit fan motor of any make of desert cooler from AGE E/M (Ref & AC) yard to contractor workshop dismantling of motor, taking out burnt winding and rewinding with the same size of supper enameled copper wire including insulating, varnishing, greasing and replacing defectivde bushes & shaft and testing and transporting back to AGE E/M (Ref & AC) yard all as directed by EIC.
S&F (In repair) Gun metal globe or gate valve, with iron wheel head, screwed both end for iron pipe and fixed all as directed by EIC size 15mm dia
S&F in repairs of PVC connection 15 mm dia with brass ferule both and length 600 mm all as specified. Make Prayag/ Polytuf
S&F ( in repairs) float valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified.
S&F (in replacement) copper cable twin core PVC insulated and sheathed size 23/0076 ISI mark for pannel wiring of desert cooler.
S&F in repairs of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24"/18" sweep desert cooler all as directed by EIC.
Taking down carefully desert cooler from existing position from stand or pillar removing the side poanels, taking out the used wood wool pads or stravy/pads and its disposal to a distance next 50 meter and spray painting to the desert cooler (inside/outside) alongwith exhaust fan/kit fan without disumbing the electric connectiioon with two coats of symthetic enamel paint of approved shade or tint including necessary preparation to steel furface and reaseembling, reinstalation of the desert cooler to its existing location complete all as specified and directed for the desert cooler of size Desert cooler of 600mm sweep exhaust fan/kit fan including steel stand.
S & F in Replacement of of 13 TR Water colled condenser suitable for existing plant including R 407 refgrant gas as suiatble qty with testing and commisioning all s specified and directed .
S & F in Replacement of 13 TR SCROLLED COMPRESSOR suitable for existing plant including R 407 refgrant gas as suiatble qty with testing and commisioning all s specified and directed .
Taking down carefully aluminium point wiring 1.5 Sqmm of light /fan /switch socket 5/15 Amps point complete including switch and making good distrubed surface of wall / ceiling etc all as specified
M&L point wiring for one light/fan point/bell controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified. Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB .
M&L point wiring for one socket outlet point 5 amps on independent board controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified.Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB (Note : cutting chasising included in quoted rate )
All as per above item No 104 hereinbefore but one socket outlet point on same baord with other switches with 1.5 sq mm single core multistranded PVC insulated FRLS cable including 1.5 sq mm single core multi stranded copper cable used as continuous earth wire.Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB .
M&L point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly complete all as specified.Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB .
S & F switch piano flush button single, pole one way, 6 Amp ( ISI marked) complete all as specified and directed.
Supply and fixed polycarbonate switch and socket combined 5 Amps . Complete all as specified and directed
Supply and fixed polycarbonate switch and socket combined 15 Amps . Complete all as specified and directed
S&F epoxy powder coated distribution box double door SPN 8 way, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal door all as specified and directed. (Make :- Legrand Cat No. 6077 11 or equivalent of other specified make.
S&F MCBs SP, 6 to 32 Amps, 240 Volts in DBs catered here in after complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCBs are including in unit rate of each MCB of any rating)
SPN, 32 to 63 Amps, 240 Volts (Cat No. 6032 48 to 6032 54 of Legrand or equivalent of other specified of other specified make)
SPN, 6 to 32 Amps, 240 Volts (Cat No. 6032 48 to 6032 54 of Legrand or equivalent of other specified of other specified make)
S&F LED light fitting 9W for mirror with clear glass complete making connection complete all as spcified and directed
S&F (in repair) epoxy powder coated distribution box SPN 4 way, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal door all as specified and directed. (Make :- Legrand Cat No. 6077 10 or equivalent of other specified make.
M&L for sub main wiring comprising two core, 6 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 6 Sq mm nominal cross sectional area on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified (Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tenderer). (Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB .
Supply & fixing submain wiring with 2 single core, 4 sqmm PVC insulated and unsheathed, multi stranded with copper conductor cable using colour code for phase red and for neutral black in and including 4 sqmm PVC insulated and unsheathed copper conductor solid cable in green colour concealed from common earth point and connected to earth dolly drawn through PVC rigid conduit 25mm bore, heavy grade (ISI marked) with and including all accessories, fixed to wall/floor with saddles and spacers, as in repairs etc, complete all as specified and directed. NOTE:- (i)Two run of 4sqmm, one run of 4 sqmm and PVC pipe shall be measured as one unit only. (ii) Cable shall be of ISI marked of make M/s Finolex / M/s Nicco/ M/s Plaza/ M/s Havells. (iii) Cutting / chassing shall be included in quoted rate
Supply & fixing exhaust fan 450mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.Make: Bajaj/CG
Supply & fixing exhaust fan 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.Make: Bajaj/CG
Supply and fixing LED tube light fitting 18W Retro Bar Professional WH 5700K/CW 6500K. prewired including providing connection of size 23/.0076 of required length form ceiling rose to the tube light fitting complete all as specified Cat No. BJCEB LED Tube (Single) of Bajaj equivalent of other specified make.
S&F Energy Efficiency Recessed Mounted LED luminire Suitable for 2x2 Grid Ceiling with making of holes in existing ceiling (False / Gypsum ) . The luminaire is offers of two colours Grey(GR) and White (WH) in combination with Profiled and flat diffuser.RC365 B - Profiled diffuser , RC366B : Flat diffuser. Lumen Output of 3300 Lumens. Constant current electronic driver and making connection with suitable size copper conductor wire complete all as specified and directed Cat No. RC365B LED33-5000 PSU OD WH of Philips or equivalent of other specified make.
Supply only flexible copper cable three core suitable for connection CFL fitting 2 x36 watt /3 x 36 watt complete all as specified and directed
S&F Distribution Board TPN with and including of DPX MCCB 35 KA 160 Amps MCCB FP, as incomer and SP/TPN MCBs as outgoing protection class IP 54, 4 way (DPX 160+12) with metal door double door Cat No 607913 of Legrand or equivalent other specified Make.(Note :- FP MCCBs 35 KA 160 Amps 1 No and 12 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this this item )
Supply & fixed LED recess mounting round type ceiling lights 15 watt complete all as specified and directed.
S & F in repair Sheet metal earth plug, socket, single pole and neutral with single pole MCB 20 Amps 240 Volts complete all as specified and as directed. Make : Havells Cat Pat No. DPSSN 020 or equivalent in Legrand / Indo Asian.
S & F Penta door bell electric suitable for AC 230 volt, single pole completeall as specified and directed. Make :- Anchor/ RIDER.
S & F switch bell push flush type 5 Amp (ISI marked) complete all as specified and directed.
Supply and fixing flexible pipe of 20 mm dia complete all as specified and directed
M&L (in repair) ceiling rose 3 phase/PVC/polycarbonate, isolated body specified make all as specified.
Supply only plug top 15 Amps 220 volt 50 hz complete all as specified and directed
Earthing complete with GI plate electrode of size 600x600x 6mm buried directly in ground vertically to depth of not less than 2.25 mtr below ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground connected to GI 4 mm dia earth wire by means of bolts, nuts and washers etc made out of GI, earth strip protected by GI pipe medium grade 40mm bore up to 7.5 mtr and connecting to Gen Set, Neutral/Body, including necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10 cu C/C on both ways as reinforcement complete all as shown in electrical plate No 3 of MES Schedule Part I, complete all as specified and as directed.
Supply and fix Isolator 63 Amps FP AC 230 volt 50 hz . Complete all as specified and directed
Supply and fix ceiling fan 1200 mm sweep AC 230 volt 50 Hz including accessories .Complete all as specified and directed
Supply and fixing LED tube rode 18/20 watts yellow in colour of Make Bajaj or equivalent of other specified make.
Supply and fixing LED bulb 36 watts 4 pin suitable for CFL fittings 2x36/3x36 watts of make Bajaj/CG or equivallent to other specified make.
S&F in repairs LED bulb cross pin18 watts yellow in colour of Make Bajaj or equivalent of other specified make.
S & F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA
S & F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 25 KA
Enviro India
M/s ARPIT ENTERPRISES
LUCKNOW REFRIGERATION CORPORATION
M/s Hanspal Enterprises
Avion Industries
PUMA POWER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .