Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹45.7 L+₹2.4 L (5.52%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹45.9 L+₹2.6 L (6.00%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹51.5 L+₹8.2 L (18.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | Rejected-Technical NEAR OLD INDIAN OIL DEPOT JALANDHAR JAMMU BYE PASS ROAD PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹41.7 L
EMD Value
₹83,380
Closing Date
11 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
SPL REPAIR FOR ELECTRIC SUPPLY SYSTEM AT MES INSTALLATION UNDER AGE E/M-I OF GE (N) MAMUN
2023_MES_633180_1
GE(N)/M-65/2023-24
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹83,380
13 Feb 2024
16 Dec 2023
13 Jan 2024
16 Dec 2023
11 Jan 2024
30 Dec 2023
Amount
Supply and fixing in replacement of battery bank constant current, constant voltage (CCCV) battery charging (float or boost) unit to charge 30 Volt DC battery bank fitted with digital volmeter and ammeter, SCR controlled and consisting of double wound transformer (provide with best quality CRGO lamination core high efficiency) an SCR/diode bridge, smoothing chock, capcitor and electric ckts for controlling the voltage and current placed on rack made out of angle iron frame and solid square bars as required suitable for floor mounting including 15 Nos batterys of 2V each 110 AH. The charger shall have indication for main supply, mode of charging (float or booast) polarity better reverse and over load conditions polarity for over load short cicuit reverse polarity and surge transient. The charger have to alarm on fuse blowing and in meter shall be provided with suitable capacity of MCB. Other technical specification shall be as under :- (a) Input voltage/working voltage 180-270V (b) Normal input voltage 240V AC, 50 Hz, single phase. (c) Float cum boost charging automatically changes from one state to another states as per batter should give the visual indication either float or boost based in charging mode.
Disconnecting electrically, dismantling and taking out old unserviceable HT busbar chambers complete all as specified and directed .
Supply, fixing, commissioning and testing of HT 11 KV, busbar chamber of suitable size, outdoor type, floor mounted, made out of CRCA sheet of thickness 3.15 mm and CPRI approved including weather proof, dust and vermin proof, having IP - 65 rated protection and painted with powder coated having 8 tank process, with common elecrolytic, sleeve insulated Aluminium busbar not less than 400 Amp capacity and mounted on high quality insulators, 3 phase having phase to phase and phase to body designed with a minimum distance of 200 mm alongwith double door and locking arrangements duly provided with 11KV danger notice plate including provision of angle iron frame for errection of panel made out of 50mm x 50mm x 6mm angle iron with each leg of 900 mm long duly painted with two coats of synthetic enamel paint over a coat of redoxide primer including providing plain cement concrete block of grade (1 : 3 : 6) type C-1 (using 20 mm graded crushed stone aggregrate) with internal ducts for incoming and outgoing cables, complete earth work (excavation, returning filling in and disposable of suplus soil to a distance not exceeding than 50mtr) in any type of soil and making all electric connections complete all as specified and as directed.
Disconnecting electrically, dismantling and taking out old unserviceable LT panel, feeder pillar box complete all as specified and directed .
M&L for earthing complete with GI earth plate electrode of size 60cm X 60cm and thickness not less than 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including using GI strip as earthing lead of size 32x6 mm by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia GI pipe connected to equipments and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 making test point and all connections complete all as specified & directed.
All as srl item No 11 above but using GI wire 4mm dia as earthing lead.
Disconnecting electrically and taking out LT cable of size up to 150 Sqmm from trenches/cable duct/through wall/pole carefully complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately.
All as per item 13 but cables of size 185 Sqmm to 300 Sqmm
Relaying of LT cable of size up to 150 Sqmm (retrieved from item No 13 above) after repairs in same or other indicated location (including making good all distributed wall surfaces/ flooring/tilling/road to match with existing specification) and testing on completion complete all as directed.
All as per item 15 but cables of size 185 Sqmm to 300 Sqmm
Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 300 Sqmm 3.5 core (including making good all distributed wall surfaces/ flooring/tilling/road to match with existing specification) and testing on completion complete all as specified directed.
All as per item No 17 but cable of size 240 Sqmm 3.5 core.
All as per item No 17 but cable of size 185 Sqmm 3.5 core.
All as per item No 17 but cable of size 150 Sqmm 3.5 core.
All as per item No 17 but cable of size 95 Sqmm 3.5 core.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm complete all as specified directed. Make: Denson/ M seal/3 M.
Supply and fix Cable end jointing kit for 1100 volt grade cable for outdoor termination, heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5/4 core complete all as specified directed.
All as per item No 23 but for cable of size 70 to 150 Sqmm 3.5 core.
All as per item No 23 but for cable of size 185 to 300 Sqmm 3.5 core.
Material and labour for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing/ fixed to walls or pole cut to piece complete all as specified and as directed. Note: Clampsof size 25x4mm for fixing pipe, nuts, bolts washers shall be measured separately.
All as per srl item No 26 but GI tubing of size 80mm bore.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth for laying of cables, foundation of poles or stays and for rerouting of cables complete all as specified and as directed.
Returning filling, in including spreading , levelling, watering and well ramming in layers not exc 25 cm each complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable (punned thickness i.e 18cm shall be measured and paid) complete all as specified and as directed.
Supply and laying unreinforced precast concrete cable cover, class LV type 1, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
Deduct : Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 93,813.25 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
KULBHUSHAN AGGARWAL
Ashoka Engineers
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .