| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹6.7 L+₹1.3 L (24.2%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC NOT LOWEST |
| Sl No | Description | Qty | Unit | cooltech engineering services L1 | Shree Ayyappa Engineering L2 |
|---|---|---|---|---|---|
| 1.00 | Taking out unserviceable submersible pump set 3 phase, 415 volts, 50 Hz of 03 to 05 HP including vertical column GI pipes of any size alongwith submersible cable from existing borewell at any depth and kept in safe custody for reinstallation after repairs and including lowering the submersible pump set into the borewell duly reconnecting and jointing of new or taken out vertical column GI pipes of any length along with new or taken out submersible cable by providing water proof jointing complete carefully by using necessary chain pulley /T&P / tripod etc complete all as specified and directed. Note :- (i) New column GI pipes and submersible cable shall be measured and paid separately. | 2 | Each Job | 4,300 ₹8,600 Lowest | 5,000 ₹10,000 |
| 2.00 | Dismantling the submersible pump set of capacity 3 HP to 5 HP, 3 Phase, 415V, 50Hz of any type/make and carrying out servicing, overhauling, greasing and examine carefully ,repairs and replacement of minor spare parts such as pump shaft key, rotor key, sand guard, pump fixing stud, oil seal, neck ring, guide vane, adopter bearing bush, suction strainer, nuts, bolts and washers etc and including replacement of spares Viz: Counter thrust bearing , thrust bearing with CI housing , pump sleeves , motorbearing bush , impeller radial flow of stain less , impeller mix flow SS , revolving plate , cable etc. and assembling and refixing of pump and motor , including painting to pump and motor with two coats of anti corrosive paint over a coat of red oxide primer after preparation of surfaces . Testing after repair , complete all as specified and directed.
Note :- (i) The rate quoted by contractor shall deemed to be included of all replacement of minor spare parts other than supply only. (ii) The cost of transport to civil trade shop for repairs is deemed to be included in rate quoted by the contractor. (iii) Labour charges for replacement of items under supply only are deemed to be included in rate quoted by the contractor | 2 | Each Job | 3,900 ₹7,800 Lowest | 5,000 ₹10,000 |
| 3.00 | Supply only counter thrust bearing suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed | 2 | Each | 430 ₹860 Lowest | 505 ₹1,010 |
| 4.00 | Supply only thrust bearing with CI housing suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed | 2 | Each | 830 ₹1,660 | 300 ₹600 Lowest |
| 5.00 | Supply only pump sleeves suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed. | 2 | Each | 330 ₹660 | 300 ₹600 Lowest |
| 6.00 | Supply only motor bearing bush suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed. | 2 | Each | 330 ₹660 Lowest | 500 ₹1,000 |
| 7.00 | Supply impeller radial flow stainless steel suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed. | 8 | Each | 630 ₹5,040 Lowest | 715 ₹5,720 |
| 8.00 | Supply only impeller mix flow stainless steel suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed. | 8 | Each | 630 ₹5,040 Lowest | 640 ₹5,120 |
| 9.00 | Supply revolving plate suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed. | 2 | Each | 280 ₹560 Lowest | 290 ₹580 |
| 10.00 | Dismantling the centrifugal/MOno block/Booster pump set of capacity 3 HP to 5 HP, 3 phase, 415 volts, 50 Hz of any type/make and carrying out servicing, overhauling, greasing and examine carefully , repairs and replacement of minor spare parts such as gaskets of any type, gland rope, shaft key,terminal board, mechanical seal, shaft sleeve, gland plate, nuts, bolts and washers and including replacement of spares Viz: copuling set with rubber bush, gun metal impeller, ball bearing (D.E), ball bearing (N.D.E), stailess steel shaft, external fan, delivery flange, suction flange, bearing housing and ressembling, including painting to pump set and base frame with two coat of synthetic enamel paint of existing colour after preparation of surfaces to achieve smooth finish including reconnecting of pipes and electric connection to existing system and testing complete all as specified and directed.
Note :- (i) The rate quoted by contractor shall deemed to be included of all replacement of minor spare parts other than supply only. (ii) The cost of transport to civil trade shop for repairs ideemed to be included in rate quoted by the contractor. (iii) Labour charges for replacement of items under supply only are deemed to be included in rate quoted by the contractor | 4 | Each Job | 2,400 ₹9,600 Lowest | 3,200 ₹12,800 |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
4 Feb 2026, 6:00 pmClosed
GARRISON ENGINEER DAMAN
Garrison Engineer Daman, Tat Rakshak Vihar, Dalwada, Nani Daman Post, Daman (UT) PIN 396210
REPAIR AND MAINTENANCE OF WATER PUMP SETS, CONTROL PANELS, WATER PIPE LINE, VALVES, CLEANING OF UG SUMP AND ASSOCIATED WORK AT POWAI, BORIVALI, WORLI, CG MALAD
2026_MES_748141_1
8923/E8
Open Tender
Civil Works
Works
330 days
WORLI, BORIWALI, POWAI, MALAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER DAMAN
₹12,000
2 Apr 2026
12 Jan 2026
7 Feb 2026
12 Jan 2026
4 Feb 2026
27 Jan 2026
Taking out unserviceable submersible pump set 3 phase, 415 volts, 50 Hz of 03 to 05 HP including vertical column GI pipes of any size alongwith submersible cable from existing borewell at any depth and kept in safe custody for reinstallation after repairs and including lowering the submersible pump set into the borewell duly reconnecting and jointing of new or taken out vertical column GI pipes of any length along with new or taken out submersible cable by providing water proof jointing complete carefully by using necessary chain pulley /T&P / tripod etc complete all as specified and directed. Note :- (i) New column GI pipes and submersible cable shall be measured and paid separately.
Dismantling the submersible pump set of capacity 3 HP to 5 HP, 3 Phase, 415V, 50Hz of any type/make and carrying out servicing, overhauling, greasing and examine carefully ,repairs and replacement of minor spare parts such as pump shaft key, rotor key, sand guard, pump fixing stud, oil seal, neck ring, guide vane, adopter bearing bush, suction strainer, nuts, bolts and washers etc and including replacement of spares Viz: Counter thrust bearing , thrust bearing with CI housing , pump sleeves , motorbearing bush , impeller radial flow of stain less , impeller mix flow SS , revolving plate , cable etc. and assembling and refixing of pump and motor , including painting to pump and motor with two coats of anti corrosive paint over a coat of red oxide primer after preparation of surfaces . Testing after repair , complete all as specified and directed. Note :- (i) The rate quoted by contractor shall deemed to be included of all replacement of minor spare parts other than supply only. (ii) The cost of transport to civil trade shop for repairs is deemed to be included in rate quoted by the contractor. (iii) Labour charges for replacement of items under supply only are deemed to be included in rate quoted by the contractor
Supply only counter thrust bearing suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed
Supply only thrust bearing with CI housing suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed
Supply only pump sleeves suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed.
Supply only motor bearing bush suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed.
Supply impeller radial flow stainless steel suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed.
Supply only impeller mix flow stainless steel suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed.
Supply revolving plate suitable for submersible pump sets of capacity 3 HP to 5 HP complete all as specified and directed.
Dismantling the centrifugal/MOno block/Booster pump set of capacity 3 HP to 5 HP, 3 phase, 415 volts, 50 Hz of any type/make and carrying out servicing, overhauling, greasing and examine carefully , repairs and replacement of minor spare parts such as gaskets of any type, gland rope, shaft key,terminal board, mechanical seal, shaft sleeve, gland plate, nuts, bolts and washers and including replacement of spares Viz: copuling set with rubber bush, gun metal impeller, ball bearing (D.E), ball bearing (N.D.E), stailess steel shaft, external fan, delivery flange, suction flange, bearing housing and ressembling, including painting to pump set and base frame with two coat of synthetic enamel paint of existing colour after preparation of surfaces to achieve smooth finish including reconnecting of pipes and electric connection to existing system and testing complete all as specified and directed. Note :- (i) The rate quoted by contractor shall deemed to be included of all replacement of minor spare parts other than supply only. (ii) The cost of transport to civil trade shop for repairs ideemed to be included in rate quoted by the contractor. (iii) Labour charges for replacement of items under supply only are deemed to be included in rate quoted by the contractor
Supply only coupling set with rubber bush for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Gun metal impeller for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Ball bearing (D.E) for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Ball bearing ( N.D.E) for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Stainless steel shaft for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only External fan for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Delivery flange for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Suction flange for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Supply only Bearing housing for centrifugal pump set 3 HP to 5 HP complete all as specified and directed.
Dismantling the centrifugal/mono block/booster pump set of capacity 7.5 HP to 15 HP, 3 phase, 415 volts, 50 Hz of any type/make and carrying out servicing, overhauling, greasing and examine carefully , repairs and replacement of minor spare parts such as gaskets of any type, gland rope, shaft key,terminal board, mechanical seal, shaft sleeve, gland plate, nuts, bolts and washers and including replacement of spares Viz: copuling set with rubber bush, gun metal impeller, ball bearing (D.E), ball bearing (N.D.E), stailess steel shaft, external fan, delivery flange, suction flange, bearing housing and ressembling, including painting to pump set and base frame with two coat of synthetic enamel paint of existing colour after preparation of surfaces to achieve smooth finish including reconnecting of pipes and electric connection to existing system and testing complete all as specified and directed. Note :- (i) copuling set with rubber bush, gun metal impeller, ball bearing (D.E), ball bearing (N.D.E), stailess steel shaft, external fan, delivery flange, suction flange, bearing housing, if required shall be measured and paid separately as supply only (ii) The rate quoted by contractor shall deemed to be included of all replacement of minor spare parts other than supply only. (iii) The cost of transport to civil trade shop for repairs ideemed to be included in rate quoted by the contractor (iv) Labour charges for replacement of items under supply only are deemed to be included in rate quoted by the contractor
Supply only coupling set with rubber bush for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Gun metal impeller for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Ball bearing (D.E) for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Ball bearing ( N.D.E) for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Stainless steel shaft for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only External fan for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Delivery flange for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Suction flange for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Supply only Bearing housing for centrifugal pump set 7.5 HP to 15 HP complete all as specified and directed.
Material and Labour for rewinding of submersible motor of capacity of 3 HP to 5 HP, 3 phase, 415 volts, AC of any type/make with copper winding wire with polywrap of existing gauge and number of turns including removing old burnt out winding carefully without damaging to other parts and testing complete all as specified and directed.
Material and Labour for rewinding of centrifugal motor of capacity of upto 5 HP , 3 phase, 415 volts, AC of any type/make with copper winding wire with polywrap of existing gauge and number of turns including removing old burnt out winding carefully without damaging to other parts and testing complete all as specified and directed.
Material and Labour for rewinding of centrifugal motor of capacity of 7.5 HP to 15 HP, 3 phase, 415 volts of any type/make with super enamelled copper winding wire of existing gauge and number of turns including removing old burnt out winding carefully without damaging to other parts and testing complete all as specified and directed.Note for item No's 30 to 32 :- The cost of transport to civil trade shop for rewinding is deemed to be included in rate quoted by the contractor
Removing of old unserviceable DOL starter from existing position after disconnecting of electric connection and supply and fix new DOL starter three phase, 415 volts, 50 Hz suitable for 1HP to 3HP pumpset complete with inbuilt accessories such as contactor, relay, timer etc and fully prewired in sheet steel enclosure and connecting to the existing system including testing complete all as specified and directed. Make :- L&T/Siemens/Crompton
Removing of old unserviceable DOL starter from existing position after disconnecting of electric connection and supply and fix new DOL starter three phase, 415 volts, 50 Hz suitable for 5HP pumpset complete with inbuilt accessories such as contactor, relay etc and fully prewired in sheet steel enclosure and connecting to the existing system including testing complete all as specified and directed.Make :- L&T/Siemens/Crompton
Removing the unserviceable single phasing preventor after disconnecting of electric connection and supply and fix new single phasing preventor 415V, AC, 50Hz suitable for pumpset upto 15 HP and reconnecting of electric cables and testing complete all as specified and directed. Make : Minilec / L&T / Siemens
Supply and Fix LED phase indicating lamp R-Y-B colour as required at site complete with base holder suitable for AC, 240 volts and testing including removing of old unserviceable lamps complete all as specified and directed. Make : Minilec / L&T / Siemens/AE
Supply and Fix digital type voltmeter 0-500 volts range, flush type, AC, 50Hz in existing panel boards after disconnecting of cables and testing including removing of unserviceable voltmeter complete all as specified and directed. Make : Minilec / L&T / Siemens /AE
Supply and Fix digital type ammeter 0-50 Amps range,flush type with appropriate CTs, AC, 50Hz in existing panel boards after disconnecting of cables and testing including removing unserviceable item complete all as specified and directed. Make :- AE / L&T / Secure / Enercon
Supply only submersible cable 3 core, 4 sqmm copper conductor multistranded,1100 volts grade, flat type, PVC insulated, sheathed and testing complete all as specified and directed.Make :- Finolex /Polycab / Havells
Material and labour for fabrication of duct cover made out of mild steel chequered plate of 7mm thick with provision of lifting handles, fire points, ladders, pipe supports and bracings etc made out from mild steel angle iron, channel, flat iron of suitable sizes including and welding as per site requirement and carry out two coat of synthetic enamel paint of red colour to fire points and grey colour to ladder, supports,duct cover etc over a red oxide primer including removing old rusted unserviceable items complete all as specified and directed.
Supply and fix in repair MCB SP 6-32 Amps,10KA,'C' series, 240 volts and , complete all as specified and directed. Make :- L&T / Havells / Schneider
Supply and fix in repair MCBs , TPN 63 Amps,10 KA ,'C' series, 415 volts , complete all as specified and directed. Make :- L&T / Havells / Schneider
S & F Pressure gauge 4" dial 0-21 kgs rating with taking down old u/s pressure gauge of any type
M&L for Repair of foot valve 50 mm to 100 mm size (As per site) after disconnecting & removing the foot valve from balancing tank , and refitting/relaying after rectification by replacing heavy duty leather gasket, nuts & bolts if any complete all as directed by Engr-in-Charge
M & L for detecting water leakage/blockages in underground water pipe lines, turning off/On water and draining the system as required, with necessary excavation at location of leakage/blockage and carrying out repair of GI/CI pipe of any size with tightening of loose connection, removing & cleaning blockage, replacement of u/s fittings & repair/replacement of joints, all as specified and direted by Engineer In Charge Note: 1. Excavation & Earthwork, Additional Pipe, Joint and jointing material shall be included in the quoted rate. 2. GI / CI fittings such as bends, elbows, tees, reducers, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc of any size shall be included in the quoted rates.
Supplying , Laying and testing galvanised steel tubing of size 50 mm dia "medium grade" in any lengths with all GI fittings such as bend, tee, short piece, socket, union, nipple, connector, elbow etc and laid in trenches / on wall /floor / road cross etc and including removing/taking down of old unserviceable pipes and fittings , complete all as specified and directed. Make :- Jindal / Tata / Surya prakash
All as per srl item No 48 here-in-above but of size 40 mm dia.
All as per srl item No 48 here-in-above but of size 32 mm dia.
All as per srl item No 48 here-in-above but of size 25 mm dia.
Cutting existing Galvanised iron pipes of 40mm or 50mm dia and screwing existing steel tubing for alterations or additions complete all as specified and directed.
Supply, fixing, jointing and testing, non return valve 40/50 mm dia , gun metal body, screwed ends, suitable for GI pipe or fittings and testing including removing old unserviceable item complete all as specified and directed. Make:- KIRLOSKER / LEADER /BIR / VENUS.
Taking out the unserviceable gate valve of any type and supply and fix gun metal gate valve of size 50 mm dia with iron wheel head screwed both ends suitable for iron pipes/fittings complete all as specified and directed. Make:- KIRLOSKER / LEADER /BIR / VENUS.
All as per srl item No 54 here-in-above but of size 40 mm dia.
All as per srl item No 54 here-in-above but of size 25 mm dia.
M & L for Preparation of old painted surfaces and applying two coats of synthetic enammel paints as directed by Engr-in-Charge on external surfaces of water pipe lines, chambers, pump, motors with brush application complete all as specified and directed by Engr-in-charge.
Cleaning the semi underground/terrace reservoir of cap upto 45000 Ltrs by draining the complete water and removing the complete mud/ silt and and washing the complete inner surface of the tank by mechanical method and writing the date of cleaning on surface of tank with white synthetic enamelled paint on black background including covered the opening hole of tank with chicked wire mesh with iron frame , hinges and locking arrangement complete all as directed by Engr-in-Charge. Note: (i) Each tank at different location (ii) T&P, material, labour involved in cleaning shall be arranged by the contractor without any extra cost to the department.
M & L for carry out water quality anyalsis for bacterial , chemical and biological analysis including for collection of water samples from the Pump House at powai, Panvel, Murud janjira or form location as specified by Engineer-in-charge and testing from Govt approved testing laboratory , submitting of report from minium following parameters . (a) Turbudity (NTU) (b) pH (c ) Total Hardness as CsCO2(mg/l) (d) Iron as Fe(mg/l) (e) Magnesium as Mg (mg/l) (f) E-coli or thermotolerant coliform bacteria (g) Remarks of Govt testing lab . Notes: 1. Saperate water samples should be collected & tested for Each location as specified above (03 Locations in a gap of 06 Months(02 times from each location)). 2. Not Carrying out water test/Non submission of water test report in respective month will impose penalty at the two times of quoted rates
Material and Labour for construction of brick masonary valve chamber 900 x 900 x 900 mm (internal dimensions), 15 cm thick foundation by using PCC 1:4:8 (type D2), brick work in cement mortor 1:6,10 mm thick plaster internally and 15 mm thick externally in CM 1:4 above ground level, 6 mm thick MS sheet cover with hinges, with hold fasts and locking arrangement fixed to angle iron frame made out of 40mmX40mmX6mm complete with two coat of synthetic enamel paint over one coat of red oxide primer on all metal works and two coat of white wash on all plastered surfaces of valve chamber including excavation, earth work in any strata including disposal of surplus soil to a distance of not exc 50 mtr complete all as specified and directed
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
Cutting of existing bituminous surface/PCC hard standing by using mechanical method of any type for laying of pipe and making good of disturbed surfaces to match with adjoining surface complete all as specified and directed. Note:-PCC for making good shall be measured and paid separately)
Material and Labour for for PCC 1:3:6, type C2 (40 mm graded stone aggregate) as in foundations / making good of disturbed surfaces / filling mass concrete complete all as specified and directed
Supply and fix in new foot valve 40/50 mm dia including checking , removal and refixing and removal of old foot valve from sump complete in all respect all as specified and directed.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip 25 x 4 mm size by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) and RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing of earthing on completion complete all as specified & directed. Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length, removal and refixing of existing interlocking tiles/PCC required for earthing strip connection to earthpit and making good.
Supply and fix galvanised iron strip of size 25 x 4 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal including taking down old strip complete all as specified & directed.
Supply only calcium based granual high strength chlorine hypochlorite 65 to 70% for drinking treated water complete all as directed.
Development of bore well of upto 780 mm bore and not less than 50 meters deep of as per existingdepth at the pressure not less than 6kgs/SqCm by using suitable air Compressor and connecteditemems to improve the yield of bore well incl replacing of broken casing with as per existing type and sizel inci welding, cuting, lowering, dismantling, boring, PCC complete all as specified and directed NOTE: (i) Transportation of air compressor / boring machine along with tools and accessories at differentlocation for devolopment of bore well shall be the responsibility of contractor and the rate quoted will be deemed in the quoted rate). (ii) M&L for removing the blockage in bore well casing pipe at the depth not less then 50 meters from ground level by means of bocky or any means without damaging the casing (filter and blind pipe) upto the depth of bore. (iii) Replacement of damaged/broken casing pipe or unaligned/iregular then the same will be replaced / repaired or aligned by proper way for smooth unctioning of borewell without any cost to the dept. (iv) Payment will be made only after successfully testing the yield of water. Note: Above all maintenance works shall be done in all areas of Mumbai Area under GE Daman all as specified and directed by Engr-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_837819.xls
BOQ • 1.52 MB
RAR.rar
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .