Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.4 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹39.7 L+₹1.6 L (4.17%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | 3₹42.2 L+₹4.1 L (10.7%)Rejected-AOC | 3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | 4₹44.3 L+₹6.2 L (16.3%)Rejected-AOC | 4 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Mar 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
PROVN OF SPL REPAIR TO CAPACITOR BANK PANELS,STP AND BLDG NO. T/84 SINGLE OR ACCN UNDER GE SATWARI
2020_MES_326359_1
GEJM-77/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE SATWARI
₹80,000
Yes
1 May 2020
18 Feb 2020
19 Mar 2020
18 Feb 2020
17 Mar 2020
3 Mar 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of pipe line ,connection etc and getting out all in hard and dense soil.
Excavation in trenches for laying underground cables, poles and stays in any type of soil (soft) not exceeding 1.5m wide and not exceeding 1.5m deep and getting out.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Dismantling timber scantlings 40 Sqcm & over in section, in any position in unframed work.
Dismaniting of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete.
Dismantiling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
Taking down chowkhats or frames (without taking off shutters from the frame) not exceeding 1.5 sqm each and removing from site complete all as specified.
Taking down shutters exceeding 1.0 sqm but not exceeding 2.0 sqm each and removing from site complete all as specifeid.
Taking down cement plaster of any description on brick walls etc. Including racking out jointing, hacking for key, scrubbing down with water and removing all the demolished material outside cantt area.
Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench
Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class 'B' bricks.
M&L for machine cut Kota Stone slab flooring 16- 18mm thick over 20mm thick screed bed in C:M 1:6 and jointed with grey cement slurry mixed with or without pigment to match the shade of the slab including rubbing and mirror polishing complete all as directed by Engr-in-Charge.
M&L for machine cut Kota stone slab 16-18mm thick in riser of steps, skirting, dado and pillar laid over 15mm thick in cement mortar 1:4 and jointed with grey cement slurry mixed with or without pigment to match the shade of the slab including rubbing and mirror polishing complete all as directed by Engr-in-Charge.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 sqm, as in skirting and jointed in neat cement slurry and pointed in white or coloured cement to match on 10mm thick rendering complete all as specified. .
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Make : Tata, JSW, Essar (Sample as approved & kept in GE's sample room).
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. Make : Tata, JSW, Essar (Sample as approved & kept in GE's sample room).
Supply and fixing GI snap grid frame work (Grid size 605cm x 605cm) for false ceiling consisting of main runner 'T' of size 24mm x 32mm and 0.3mm thick , Secondary runner 'T' of size 24mmx25mm and 0.3mm thick, GI angle 24mmx24mm and 0.4mm thick, Bottom exposed capping of width 24mm of all T-sections shall be of 0.25mm thick PPGI, hot dipped galvanised steel with zink coating not less than 120gm / Sqm, ceiling grid system duly suspended by 4mm dia GI wire hanging from existing purlins /roof slab with butterfly clips including Gypsum ceiling tiles of size 595 x 595 x 9 mm laminated with 0.07 mm thick polyvinyl film on the face side and 10 micron metalized polyester film on the back side fixed on GI snap grid including taking down of old us material complete all as specified and directed by Engr-in- Charge.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, incl providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hardcore, etc., to store and rubbish not exc. 50 m.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:4 complete.
Material & labour for pressed steel frame of size 125mm x 60mm made out of 1.25mm sheet for doors double rebated including mild steel hinges medium weight 100mm long and 25mm x 3mm flat iron in holdfast, tie bar including necessary fixing lugs, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:3:6 type C-I.
Material & labour for pressed steel frame of size 105mm x 60mm made out of 1.25mm sheet for doors double rebated including mild steel hinges medium weight 100mm long and 25mm x 3mm flat iron in holdfast, tie bar including necessary fixing lugs, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:3:6 type C-I.
S&F 35mm thick 2nd class HW rail and style plain, framed, factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated.
S&F 35 mm thick 2nd class HW, glazed and skelton shutters open rebated and prepared to receive glass / gauge (without sash bar) edges of forming plain chamfered orrounded fitted with cut and mitred bead for securing glass/gauge etc size of shutter as per SSR part-1 section 8 clause 8.24(a).
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aparture 1.40mm and fixed with tinned tacks or galvanised wire staples.
M&L for preparation of new wood or wood based surface and applying two coats of synthetic enamel paint over one coat of pink primercomplete all as specified.
M&L for preparation of old wood or wood based surface and applying one coat of synthetic enamel paint complete all as specified.
S&F 100mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all specified.
S&F extrude aluminium alloy handles, fabricated type, anodised size of 125 mm long complete.
S&F for Aluminium anodised, barrel tower bolts of extruded section and fixed of size 150mm complete.
S&F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete.
Material & labour factory made steel windows double shutter box type, outer frame made out of ERW TUBE 'P' section (65x45x25mm) and shutters of ERW TUBE 'P' section (50x35x20mm) operable shutters side hung including pistol hinges with two Nos of MS Tower bolts 150mm size on each shutter steel handle and stopper of 'Z' section as specified complete with sash bars dovetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings/ opening for cooler/AC where required. Steel windows will be double shutter external glazed and internal wire gauzed complete all as specified and as per Drg No CEPZ/TD-324/07 1/3 to 3/3 all as specified and directed by Engr-in-Charge. Note : The quoted rate against the above item shall also include (i) for Provn of one coat of coal tar on the ends of steel frame in contact with brick/conc surface (ii) 04 Nos MS Steel lugs of 20x5mm MS flat 20cm long over all welded to frames (iii) PCC block for embedding lugs.
Rendering 15 mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified.
Preparation of new surface of walls and applying two coats oil bound distemper over chalk whiting complete all as specified.
Rendering 15 mm thick in CM 1:4 on brick wall surface or concrete surface finished even and smooth without using extra cement complete all as specified.
Preparation of new surface of walls and applying two coats of cement base paint including priming surface with alkali resistant priming paint complete all as specified.
Preparation of new plastered surfaces including filling of small holes etc and applying three coats of of white wash over wall surface.
Hacking out old broken glass (any thickness size, quality or description) from wooden/steel frames or stone, concrete or brick surrrounds, glazed with putty or fixed with beads.
S&F 3 mm thick sheet glass ordinary quality and glazing with steel pins, oil putty to steel windows and, beads nails etc to wooden surfaces as in square n exc 0.50 sqm in each pane, all as specified. Make; Saint Gobain, Modi guard.
M&L for preparation of old steel surfaces exc 10cm in width or girth not otherwise described and applying one coat of synthetic enamel paints all as specified.
M&L for two coats of oil bound distemper to old plastered surfaces including preparation of surfaces complete all as specified and directed by Engr-in-charge.
Preparation of old plastered surfaces including filling of small holes etc and applying two coats of of white wash over wall surface.
M&L for two coats of cement base paint to old plastered surfaces including preparation of surfaces complete all as specified and directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for supporting of CI/GI pipes,header etc all as specified and directed.
Rendering 10mm thick in CM 1:3 as in ceilings or concrete surfaces such as chajjas, upward facia, downward facias and similar items finished even of smooth including dubbing coat without using extra cement upto any height including all necessary scaffolding complete all as specified.
Demolition of (Cement concrete unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing all the demolished material outside cantt area.
M&L 75mm thick plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection finished even and smooth without using extra cement complete all as directed.
Demolition of brick work built in cement mortar.
M&L for brick work with subclass 'B' old size bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces built in cement mortar 1:4 and finished even and smooth without using extra cement.
M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in surface channels and drains.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S&F rolled mild steel Fe-410-W(Gde-250) quality-B for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete.
S&F framed work such as grills granties, etc with ends of bars shouldeded etc and similar work conforming to Fe 290, Gde E 165.
Steel tubing galvanized (light grade) 40 mm bore conforming to IS-1239 forpassing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50x6mm clampsmade to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as directed by Engr-in-Charge
Cleaning of civil unit (Receiving chamber, screen channel, MBBR unit, Tube settle unit, chlorine contact tank and sludge drying bed) of the plant as directed by Engr-in Charge
M & L for replacement of tube settler media from tube settler tank of plant. PVC COOL tubes CD-TS120 (Loose leaves) surface Area: 11m2/m3 at 60 deg angle inclination, vertical ht 750mm
Supply and installation in replacement of fine bubble EPDM diffuser Dia 90mmx1000mm diffuser with 1 inch air inlet connection and SS 304 nipple EPDM membranes duly clamp. Type of diffuser : Tubular, Non-clog, Non-buoyant MOC of membrane : EPDM/PTFE layered EPDM MOC of diffuser internal : PP Silt size : Less than 1mm Area of influence zone : 2.5 Sqm Optimum through put - 10 cum/hr maximum allowable pressure - 0.7 kg/cm2. Make : SCOGEN
Taking out unserviceable butterfly valve and supply and fixing new butterfly valve (As per existing type) of cast iron both ends for flange fitting of size 200 mm dia complete
Taking out unserviceable butterfly valve and supply and fixing new butterfly valve (As per existing type) of cast iron both ends for flange fitting of size 150 mm dia complete
Taking out unserviceable butterfly valve and supply and fixing new butterfly valve (As per existing type) of cast iron both ends for flange fitting of size 100 mm dia complete
Taking out unserviceable butterfly valve and supply and fixing new butterfly valve (As per existing type) of cast iron both ends for flange fitting of size 80 mm dia complete
Taking out unserviceable butterfly valve and supply and fixing new butterfly valve (As per existing type) of cast iron both ends for flange fitting of size 50 mm dia complete
Supply and fixing rubber tyre coupling of existing size and type as specified and directed.
M&L for taking out old unsv pressure gauge indicator and replacement the same as per existing size complete and testing all as specified and directed by Engr-in-charge.
Supply and fixing in replacement PVC insulated and PVC sheathed flat submersible cable 16 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed. Make Polycab/Finolex/Havell,s
M&L for taking out old unsv MS Pipe of size 250 mm and replacement the same on appropriate size complete and testing all as specified and directed by Engr-in-charge.
M&L for taking out old unsv MS Pipe of size 150 mm and replacement the same on appropriate size complete and testing all as specified and directed by Engr-in-charge.
M&L for taking out old unsv MS Pipe of size 100 mm and replacement the same on appropriate size complete and testing all as specified and directed by Engr-in-charge.
M&L for replacement of filteration jalli along with control handle of reciving chamber ,screen chamber in each stage as per existing size of STP with existing gauge and size complete and testing all as specified and directed by Engr-in-charge.
M&L for Painting of the pump Sets,voltage by removing old paint, cleaning the surface removing all dust and oil from the surfaces with two coat of synthetic enamel paint with spray paint as per existing colour as directed by Engr-in-Charge
M&L for Painting of the pipe line upto 250 mm dia by removing old paint, cleaning the surface removing all dust and oil from the surfaces with two coat of synthetic enamel paint with spray paint as per existing colour and writing the direction and supplying area in capital letters as directed by Engr-in-Charge
Lifting & lovering of non clog submersible pump set any size from the main reciving chamber of STP as directed by Engr-in-Charge
M & L for strip opening of non clog submersible motor ,taking out roter from stater taking out burnt winding from the stater cleaning the core and rewinding the same with PVC insulated copper wire of existing gauge including other winding material as directed by Engr-in Charge of Cap up to 15 HP
M & L for Replacement the defactive part of submersible pump sets are as under:-
M & L for Replacement Thrust bearing of non clog submersible motor 15 HP all as specified and directed by Engr-in-charge.
M & L for Replacement Gun metal bushes for non clog submersible motor 15 HP all as specified and directed by Engr-in-charge.
M & L for Replacement Impellers for non clog submersible pump 15 HP all as specified and directed by Engr-in-charge.
M & L for Replacement Bowl bush for non clog submersible pump 15 HP all as specified and directed by Engr-in-charge.
M & L for Replacement Neck ring for non clog submersible pump 15 HP all as specified and directed by Engr-in-charge.
M&L for dismantling and de-coupling 20HP air blower pump from the electric motor and re-assembling the pump on existing foundation complete with motor after repair/overhaulding with following and testing complete all as specified and directed.The cost of transportation to and fro workshop is deemed to be included in the quoted rate. a) Adjustment of safety valve. b) Replacement of spring assy . c) Re-metaling/turning of pump shaft. d) Replacement of oil ENKLO 320, oil seal, bearing, filter. e) Replacement of belts ,& pressure gauge.
Replacement of automatic star delta starter three phase of size 25 HP as directed by Engr-in-charge
M & L for opening of pipe line up to 250 and cleaning ,washing and refixing the same on its original position as directed by Engr-in Charge
Repair and Maintenance of MBBR unit of plant civil work ie plastering water proofing as required at site or as directed by Engr-in -Charge
M&L for LT underground cable XLPE insulated armoured heavy duty 1100 volts 3 1/2 core grade with aluminium conductor multistranded including centre gland lugs jointing materials etc laid in trench or fixed it to wall including connecting testing and commissioning complete for 50 Sqmm x 3.5 core cable.
M&L for LT underground cable XLPE insulated armoured heavy duty 1100 volts 3 1/2 core grade with aluminium conductor multistranded including centre gland lugs jointing materials etc laid in trench or fixed it to wall including connecting testing and commissioning complete for16 Sqmm x 3.5 core cable.
Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 60 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back open able double door system lockable/open able by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely duat and vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, factory fabricated (Factory approved from CPRI) having modern fabrication and followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following:-
(a) TPN, Aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) MCCB TPN,415 volt ,50Hz 100 Amps, -01 Nos (incommer) (c) MCCB TPN,415 volt ,50Hz 63 Amps, -03 Nos (O/G) (d ) MCB SPN 06 amps, -01 Nos (O/G) (e) On load change over switch 100 Amp -01 No (f) Multifunctional digital meter to read electrical parameters viz current, voltage, frequency, energy etc – 1 Nos (g) Indication lamp RYB-1 sets
Supply, laying for replacement of unserviciable undergroundLT cable 1100 Volts grade heavy duty electric cable PVC insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes 25 Sqmm x 3.5 core Note:- Earthwork/excavation shall be measured seperately
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable PVC insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes 35 Sqmm x 3.5 core Note:- Earthwork/excavation shall be measured seperately
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable PVC insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes 50 Sqmm x 3.5 core Note:- Earthwork/excavation shall be measured seperately
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable PVC insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes 70 Sqmm x 3.5 core Note:- Earthwork/excavation shall be measured seperately
Supply, installation, testing & commissioning of APFC with APP technology capacitor bank of 100 KVAR, Feeder Pillar, (IP-65) suitable for outdoor installation made out of 3.15mm thick CRCA sheet (CPRI Approved) consisting of 1/2/5/10/15 KVAR capacitor unit in tier formation housed in an integrated cubical type automatic switching "ON" & "OFF" control panel with dust and vermin proof hinged and lockable door complete with interconnection, bonding to earth and painting (suitable for 400/440 volts, 3 phase 50 Hz supply system). Automatic switching with microprocessor based relay "ON" & "OFF" control panel for 100 KVAR capacitor in and including interconnection with LT panel with appropriate size of electric cable. Each panel consists of following:- INCOMING (a) MCCB 3 pole 320 Amp, 36 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 422001 or equivalent make of SIEMENS(3VL)(as incoming) -01 Nos
INDICATING PANEL (a) Digital multi functional meter which shows PF, Volts, Amps etc complete. (Make C&S, L&T, Havells) (b) Aluminium bus bars of suitable capacity, fixed on insulators, coated with PVC sleeves with red, yellow, blue colour. (c) Phase indicating lamps each backed up with suitable MCB. (Make C&S, L&T, Havells) (d) Indicating lamp of each rating of KVAR capacitor unit to indicate that unit is "ON/OFF". (Make C&S, L&T, Havells) (e) Intelligent power factor relay with 16 stages with 03 Nos CT 3 phase (Make C&S, L&T, Havells) OUTGOING 15 Nos of heavy duty contactors as per rating of KVAR. (Make C&S, L&T, Havells) 15 Nos of MCB TP suitable as per rating of KVAR.(Make C&S, L&T, Havells) 02 Nos 01 KVAR APP technology capacitor banks. (Make C&S, L&T, Havells) 04 Nos 02 KVAR APP technology capacitor banks. (Make C&S, L&T, Havells) 03 Nos 05 KVAR APP technology capacitor banks. (Make C&S, L&T, Havells)
Supply, installation, testing & commissioning of APFC with APP technology capacitor bank of 75 KVAR, Feeder Pillar, (IP-65) suitable for outdoor installation made out of 3.15mm thick CRCA sheet (CPRI Approved) consisting of 1/2/5/10/15 KVAR capacitor unit in tier formation housed in an integrated cubical type automatic switching "ON" & "OFF" control panel with dust and vermin proof hinged and lockable door complete with interconnection, bonding to earth and painting (suitable for 400/440 volts, 3 phase 50 Hz supply system). Automatic switching with microprocessor based relay "ON" & "OFF" control panel for 75 KVAR capacitor in and including interconnection with LT panel with appropriate size of electric cable. Each panel consists of following:- INCOMING (a) MCCB 3 pole 200 Amp, 25 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 420208 or equivalent make of SIEMENS(3VL)(as incoming) -01 Nos
INDICATING PANEL (a) Digital multi functional meter which shows PF, Volts, Amp etc complete (Make C&S, L&T, Havells) (b) Aluminium bus bars of suitable capacity, fixed on insulators, coated with PVC sleeves with red, yellow, blue colour. (c) Phase indicating lamps each backed up with suitable MCB. (Make C&S, L&T, Havells) (d) Indicating lamp of each rating of KVAR capacitor unit to indicate that unit is "ON/OFF" (Make C&S, L&T, Havells) (f) Intelligent power factor relay with 12 stages with 3 CTs of 3 phase. (Make C&S, L&T, Havells)
Supply, installation, testing & commissioning of APFC with APP technology capacitor bank of 35 KVAR, Feeder Pillar, (IP-65) suitable for outdoor installation made out of 3.15mm thick CRCA sheet (CPRI Approved) consisting of 1/2/5/10/15 KVAR capacitor unit in tier formation housed in an integrated cubical type automatic switching "ON" & "OFF" control panel with dust and vermin proof hinged and lockable door complete with interconnection, bonding to earth and painting (suitable for 400/440 volts, 3 phase 50 Hz supply system). Automatic switching with microprocessor based relay "ON" & "OFF" control panel for 35 KVAR capacitor in and including interconnection with LT panel with appropriate size of electric cable. Each panel consists of following:- INCOMING (a) MCCB 3 pole 160 Amp, 16 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 420007 or equivalent make of SIEMENS(3VL)(as incoming) -01 Nos
INDICATING PANEL (a) Digital multi functional meter which shows PF, Volts, Amp etc complete (Make C&S, L&T, Havells) (b) Aluminium bus bars of suitable capacity, fixed on insulators, coated with PVC sleeves with red, yellow, blue colour. (c) Phase indicating lamps each backed up with suitable MCB. (Make C&S, L&T, Havells) (d) Indicating lamp of each rating of KVAr capacitor unit to indicate that unit is "ON/OFF" (Make C&S, L&T, Havells) (f) Intelligent power factor relay with 08 stages with 3 CTs of 3 phase. (Make C&S, L&T, Havells)
Supply, installation, testing & commissioning of APFC with APP technology capacitor bank of 20 KVAR, Feeder Pillar, (IP-65) suitable for outdoor installation made out of 3.15mm thick CRCA sheet (CPRI Approved) consisting of 1/2/5/10/15 KVAR capacitor unit in tier formation housed in an integrated cubical type automatic switching "ON" & "OFF" control panel with dust and vermin proof hinged and lockable door complete with interconnection, bonding to earth and painting (suitable for 400/440 volts, 3 phase 50 Hz supply system). Automatic switching with microprocessor based relay "ON" & "OFF" control panel for 20 KVAR capacitor in and including interconnection with LT panel with appropriate size of electric cable. Each panel consists of following:- INCOMING (a) MCCB 3 pole 100 Amp, 16 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 42005 or equivalent make of SIEMENS(3VL)(as incoming) -01 Nos
INDICATING PANEL (a) Digital multi functional meter which shows PF, Volts, Amp etc complete (Make C&S, L&T, Havells) (b) Aluminium bus bars of suitable capacity, fixed on insulators, coated with PVC sleeves with red, yellow, blue colour. (c) Phase indicating lamps each backed up with suitable MCB. (Make C&S, L&T, Havells) (d) Indicating lamp of each rating of KVAr capacitor unit to indicate that unit is "ON/OFF" (Make C&S, L&T, Havells) (f) Intelligent power factor relay with 06 stages with 3 CTs of 3 phase. (Make C&S, L&T, Havells)
M& L For Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick buried directly in ground to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal and common salt and connected with and including GI strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of GI 40 mm bore GI pipe light grade from earth plate up to testing point for protection of GI strip and 20 mm bore GI pipe (light grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 1991 complete all as specified Note : (i) RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80 mm thick, reinforcement with 8 mm tor steel in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth electrode shall be projected upto test pit using necessary arrangement with suitable size GI pipe and the rate in the unit rate of item (iii) RCC cover shall be painted with red paint over a primer coat and the rate includes in the unit rate of item
SATISH AND CO
CELMAC REGD
M/S S K Electricals Regd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .