Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC WARD NO 6 KOKRAJHAR BAZAR ROAD P O DIST KOKRAJHAR BTC ASSAM | DHUBRI | ASSAM | 783331 | ₹1.8 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | Not Admitted-Fee/PreQual/Technical CHINMOY PATH LAKHIMI NAGAR GUWAHATI P O DISPUR P S DISPUR DISTRICT KAMRUP M ASSAM PIN 781006 | KAMRUP METRO | ASSAM | 781006 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
3 Nov 2020, 2:00 pmClosed
The Chief Engineer,PWRD (EAP),Assam
O/o The Chief Engineer,PWRD (EAP),Assam Fatasil Ambari,Guwahti- 781025
Renovation and Upgradation of Warehousing Facilities under the scheme of APART in existing Warehouse Complex at Paschim Boragaon in Kamrup(M) District.
2020_PWD_18857_2
CE/APART/67/2020/6
Open Tender
Civil Works - Building
Lump-sum
270 days
Kamrup
Please refer tender documents
7 documents required · 7 mandatory
₹5,000
State Project Director,ARIAS SOCIETY
₹3.9 L
O/o The Chief Engineer,PWRD (EAP),Assam
12 Apr 2021
6 Oct 2020
3 Nov 2020
6 Oct 2020
3 Nov 2020
6 Oct 2020
6 Oct 2020 - 17 Oct 2020
17 Oct 2020
Amount
CIVIL WORKS Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinary soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m.
Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop 1cement: 3sand :6coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). Using Mixer Machine In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture, plasticiser M20 grade concrete or Prop. 1:1.5:3.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M25 grade concrete.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). In super structure above plinth level upto first floor. Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. Without using admixture, plasticiser M20 grade concrete or Prop. 1:1.5:3.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). In super structure above plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. Without using admixture, plasticiser M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). In super structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. Without using admixture, plasticiser M25 grade concrete
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut. Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness. Using 25mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth exceeding 1.0M.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL TMT Corrosion resistant steel (CRS) reiforcement bar
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level). From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL. Super Ductile (SD) TMT reinforcement bars
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level). Other ISI approved TMT reinforcement bar (SRMB/SAI/BISCON/X TECH) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (d) In proportion 1:6.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (b) In proportion 1:4.(1 cement:4 sand)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (c) In proportion 1:5.(1 cement:5 sand)
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary. In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). 112mm thick brick wall. In cement mortar in proportion 1:4. (1 cement:4 sand)
Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. 20 mm thick
CERAMIC TILES A) ON FLOOR Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Executive range Somany/ Orient/Nitco/Asian Make Of size 400x400 mm and above
CERAMIC TILES B) ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). b) Executive range Somany/ Orient/Nitco/Asian Make ii) Of size 250mmx350mm and above
ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (B)VITRIFIED i)Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) a). Premium
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Rough Side In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Fair Side In cement mortar 1:4
Extra for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. ii) 15 mm thick plaster b) In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side c) In cement mortar 1:5
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
White washing with lime on wall surfaces (two coats) to give an even shade including throughly brooming the surface to remove all dirt, dust,mortar drops and other foreign matter.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. In cement mortar 1:5.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing wall with two coats of acrylic emulsion exterior coatings of approved brand of required shade by thinning by adding water as per the specification of manufacture after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. (c) Asian paint / Berger paint / ICI paint/J&N paint/Nerolac.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. Priming coat with distemper primer
Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. Top coat
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying one self-priming coat acrylic emulsion paint of approved brand, thinning by adding water as per specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. Unicem Shakti.
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per the specification of manufacture after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. Unicem Shakti.
Applying a floating coat of concrete floor hardner Nitoflor Hardtop or Nitoflor Hardtop standard of Fosroc (india) Ltd. over freshly prepared concrete floors followed by sprinkling of Nitoflor Hardtop or Nitoflor Hardtop standard and finishing surface using power trowel as specified and directed by the department (Concrete floor & base courses to be measured and paid separately). (b) Medium duty
Demolishing plain cement concrete including disposal of debris as directed for all levels (ii) Prop (1 : 3 : 6) or richer mix
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Extra for cutting reinforcement in RCC or RB work at all levels (Payment to be made on cross sectional area of RCC or RB work obtained by multiplying the length of the cut reinforcement and thickness of the member).
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling of existing steel windows/ steel ventilators/ steel windows and steel ventilators without damaging the walls, removing to a safe place and necessary repairs to the edges of walls.
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (ii) Area of door/window above 3.00 m2
Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S bars with round headed bolts and nuts or screws. Plain grill Fixed to Brickwork/PCC/RCC
Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. c) In M.S. angles, channels, Tees etc.
Steel work riveted and/ or bolted/ riveted in built up sections, frame work including cutting, hoisting, fixing in position and applying a priming coat of red- lead paint up to 4.6m height above plinth including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists with connecting plates/ angle cleats
Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or conmbination of following sections of (i) Square Section (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or conmbination of following sections of (i) Square Section (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications b) Using other ISI marked approved brand tube
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
Providing Iron Plastic Laminated corrugated coloured sheet Roofing at all levels including fitting and fixing galvanised J or L hooks, bolts and nuts of 8 mm diameter with Bitumen washer 35 mm x 35 mm x 3 mm and G.I. Diamond washer 40 mm x 40 mm x 3 mm complete excluding cost of roof truss, purlins etc. (Roof trusses, Purlins etc. to be measured and paid separately). (a) 0.50 mm thick
Providing Colour Coated (Iron Plastic Laminated Sheet) Ridging including supplying and fixing necessary galvanised screws / washer etc. complete as specified and directed. (A) 0.50 mm thick (i) 150 mm lapping
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (v) 0.60 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (v) 0.60 mm thick
Providing,fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 63mm x 38mm x 2.5mm section of approved brand(HINDALCO/NALCO/BALCO/JINDAL/Other equivalent primary producer) with door style of size 50mm x 45mm x 2.0mm, top rails 50mm x 45mm x 2.5mm, middle rail 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (ii) 5mm frosted glass
Providing and fixing anodised aluminium framed single leaf door of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mmx15mmx1.2mm complete with automatic hydraulic floor mounted door closure, butterfly type handles, special cylindrical locks, concealed type tower bolt,neoprene dryset rubber gusket, etc.complete as directed by the Department at all levels. (i)5mm thick frosted glass and 12mm thick prelaminated board
Providing drain with cement concrete (1:3:6)10cm thick sides 10cm thick bed over brickflat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire length and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections having thickness 1.9 mm of approved brand (HINDALCO/JINDAL/BHAGWATI/SAI(with proof of purchase of ingot from primary producer)/Other equivalent without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 3 Track sliding window 5mm clear glass
Electrical Works Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Long point up to 10.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq.mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537. Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 12 way SPN double door
Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make, Crabtree Xpro make) 4 way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager, Crabtree Xpro make) 6 to 32A
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series(ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Hager make) 250A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 63A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 100 A
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider, legrand, L&T make) 200A
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 K and Charcoal 96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x5 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENT make)
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 1-2 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 3 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE),CRABTREE as per direction of department. 1 module
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE),CRABTREE as per direction of department. 2 module
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 & 1/2 Core A2XFY 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 & 1/2 Core A2XFY 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 & 1/2 A2XWY A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 & 1/2 A2XWY A2XFY 120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supplying including installation of cast iron cable marker as specified and directed by the deptt.
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 70.00 - 150.00 Sq.mm., 3/ 3.5/ 4 Core cable.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 100 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying including installation of 4'' dia. C.I. earth pipe complete as required and as directed by the department.
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three) section having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGR make) 410 SP 66 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV TECHNICAL DATA CJ100D5P GENERATOR SET SPECIFICATIONS 100/80 3. No. of Phases. 3 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. 6BTA5.9G5 3. No. of Cylinders. 6 4. Aspiration. TURBO CHARGED after COOLED 5. Cooling. Water Cooled. 6. Governor. Mechanical 7. Battery Capacity Rating. 12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 16.9 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 WITH SRANDARD CONTROL PANEL
SANITARY WORKS Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 160mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 110mm dia.
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately). Jaquar Make (a)Continental /Clarion (ii) Bibcock long thread
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (i)15mm dia
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 50mm dia
Supplying and fitting ball valve as specified and directed. a) 25 mm dia. (gun metal)
Supplying and fitting ball valve as specified and directed. b) 20mm dia. (gun metal/Copper)
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. a) 50 mm dia (Heavy type)
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE 40mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE 160mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE 200mm diameter
Labour for sinking tube well with 40mm (internal) dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
Supplying fitting and fixing brass Tez filter 2.00 metre long.
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complete as directed. i) Maya popular - 6
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levels including below G.L. as diected and specified Exposed on walls. 50 mm dia (Medium) Using TATA make
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levels including below G.L. as diected and specified Exposed on walls. 40 mm dia (Medium) Using TATA make
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levels including below G.L. as diected and specified Exposed on walls. 32 mm dia (Medium) Using TATA make
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levels including below G.L. as diected and specified Exposed on walls. 25 mm dia (Medium) Using TATA make
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levelsincluding below G.L. as diected and specified Exposed on walls. 20 mm Dia (Medium) Using TATA make
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levelsincluding below G.L. as diected and specified Exposed on walls. 15 mm Dia (Medium) Using TATA make
Supplying fitting and fixing GI. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.l. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting H.W, clamp etc complete at all levelsincluding below G.L. as diected and specified (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. f) 15 mm dia (Medium) i) Using Tata make
Flushing, clearing, washing and watering of the tube well
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With F.P.S. bricks with class designation 75
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With F.P.S. bricks class designation 75
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. 8" Gravel filling
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. Boulder filling
Providing and laying block masonry out of best available first class Aerated Autoclave Blocks of specific thickness of desired Compressive strength (Certificate to be produced) as per drawing & details, in line, level and plumb for super structure at all heights, including galabid, bagle wall, load walls, columns, pillasters, etc., in cement mortar 1:6 including scaffolding, raking of joints, curing etc., complete as per drawings and specifications. (Rate should be including Scaffolding) (i)In super structure from plinth level upto 3.0 m (b) For 150mm thick Block
Steel work in single section for air inlet made of frame of ms angle 40x40x6mm joints metred welded with four numbers 15 cm long lugs of ms flat 20x6mm to act as hold to be fixed in cement concrete blocks of size 230x100x100 mm in cement concrete mix(1cement:2coarse sand:4 stone aggregate 12.50mm nominal size)including and fixing GI wire fabric to be fixed with 15x3 mm ms flat beading tack welding including applying priming coat of zinc chromate yellow prime cleats are to be provided on inner side to withold/support the covering.Slanted MS flat strips of size 40x40x6mm to be provided as per the drawing.Complete air inlet to be manufactured and fixed in position as per the drawing as per the the direction of Engineer in Charge. Note: Cement concrete blocks shall be paid separately under relevant item
Providing and fixing 1.25 mm thick M.S.sheet steel door with frame of 40x40x6mm angle ,3mm thick gusset plate at junction and corners by using M.S.angle 40x40x6 mm diagonal braces,necessary fittings like bush hinges, handles,tower bolt , sliding doorbolt as per the drawing including a priming coat of approved steel primer of zinc chromate yellow primer.Complete door manufactured and fixed in position as per the drawing as per the direction of Engineer in Charege.
Providing integrated flooring of mixed M-25 grade (1:1:2) & of thickness 125mm by Vaccum dewatering in fresh cement concrete works laid by leveling with screed vibrator, dewatering of excess water in fresh vaccum pump with bottom filter mat & top filter mat duly sealing edges all-round finishing with power floater & trowel to attain hard surface with all lead & lift etc. all labour, materials, 40 HP generator for power supply, tools & plants to be borne by the contractor & work as directed by the engineer in charge. The contractor shall submit the details & specifications for equipment like vaccum pumps water separator, filtering mat etc. approved by the authority well in advance. The contractor should submit the relevant standard methodology of vaccum dewatering to the consultant & get it approved well in advance including groove cutting of size 5mm wide and15mm deep for providing control & construction joints including backer rod in Joint filling with sealent compound of approved make
Providing and fixing multi vent roof ventilators(Turbo ventilator)on the top of roof with high performance industrial multi vent room ventilator of minumum 530 mm dia neck/throat of Aluminium alloy designed to a capacity of 1850 CFM including FRP(Fibre Reinforced Plastic) venture dome 1.5 mm thick and all require accessories as per technical specification.Multi roof ventilators to be got approved from E.I.C. before installation .The rate includes cutting /making holes in the roofing sheet
Extra for providing neat cement polish in plinth over cement mortar plaster as directed by the engineer in charge
Providing and fixing horizontal single/multi stage pumping set with CI body, bronze impeller, stainless steel sheet and connected by a flexible coupling to a totally enclosed fan cooled indication motor mounted on common structural base plate with all pump accessories complete as per specificaions including rubber neoprendined vibration eliminators mounting pad and expansion bellow in suction discharge connection between pump and piping, motor to be suitable for 415V 3 phase 50 Hz AC supply. A.MAIN PUMP FOR HYDRANT & SPRINKLER Type of pump - Centrifugal End Suction/ Vertical on line Capacity - 2280 LPM Head -56 MWC HP - ( Power requirements as per Clause 7.4.1.5 of TAC's Fire Protection Manual)` Motor RPM - 2850
Providing and fixing horizontal single/multi stage pumping set with CI body, bronze impeller, stainless steel sheet and connected by a flexible coupling to a totally enclosed fan cooled indication motor mounted on common structural base plate with all pump accessories complete as per specificaions including rubber neoprendined vibration eliminators mounting pad and expansion bellow in suction discharge connection between pump and piping, motor to be suitable for 415V 3 phase 50 Hz AC supply. B.JOCKEY PUMP FOR HYDRANT & SPRINKLER Type of Pump - Centrifugal End suction/ Vertical on line Capacity - 180 LPM Head -56 MWC HP- 10 H.P. Motor RPM- 2900
Providing and fixing standby single/multistage horizontal centrifugal pump set of CI body bronze impeller, stainless steel shaft. The pump shall be connected by a flexible coupling to a suitable capacity of diesel engine with automatic starting alongwith battery charger, panel, including MS base plate and mountings. The diesel driven pump shall be complete with diesel tank with level indicator, exhaust piping insulated etc. complete as described in technical specifications. Type of Pump - Centrifugal End suction Capacity - 2280 LPM Engine BHP- (As per Clause No. 74.5.2.3 TAC's of Fire Protection Manual ) Head -56 MWC RPM - 1800
Providing and fixing pressure switches for every individual pump to operate at drop of pressure set for.
Providing and fixing double flanged vertical air vessel fabricated from 8mm MS plate with dished ends 450mm dia and 2m high common for fire and jockey pumps complete with Air release valve and GM gate valves in drain and all connecting nozzles etc.
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 120 sq.mm
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 25 sq.mm
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 4 sq.mm
Supply and fixing of perforated 2mm thick CRCA sheet steel powder coated cable tray of following sizes complete with bends/tees/joints, coupling plate and nuts, bolts etc. including providing and fixing of MS painted hanger etc. as required. 75x50mm
Supply and fixing of perforated 2mm thick CRCA sheet steel powder coated cable tray of following sizes complete with bends/tees/joints, coupling plate and nuts, bolts etc. including providing and fixing of MS painted hanger etc. as required. 150x75mm
Structural supports as required for cable trays complete with installation with anchor fastner/grouting as applicable. Painting with red oxide and 2 coats of enamel paint of colour as specified by Owner/Consultant.
Providing, laying, terminations of copper wire and strip of undernoted sizes in surface for connection etc. with lugs. 8 SWG wire
Providing, laying, terminations of copper wire and strip of undernoted sizes in surface for connection etc. with lugs. 25x6mm (strip)
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 25mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 50mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 100mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 150mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 200mm(6mm thick)
Providing and fixing FOOT VALVE WITH STRAINER with M.S. flanged connection. 100mm
Providing and fixing FOOT VALVE WITH STRAINER with M.S. flanged connection. 200 mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 80mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 150mm
Providing and fixing pressure gauge (0-10 Kg/Cm. Sq.) complete with isolation valve.
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 65 mm
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 80mm
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 100mm
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 150mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 25mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 50mm
Providing and fixing gunmetal four way collecting head with 63mm dia instantaneous type inlet with built in check valve for fire brigade connection to underground tanks as per IS: 904.
Providing and fixing standard draw out connection with 63mm dia instantaneous type coupling with all accessories as approved by fire authorities for installation at under ground tank.
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 25mm
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 80mm
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 100mm
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 150mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 including necessary earth excavation and refilling, masonary supports complete in all respect. (For under ground piping). 80mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 including necessary earth excavation and refilling, masonary supports complete in all respect. (For under ground piping). 100mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 including necessary earth excavation and refilling, masonary supports complete in all respect. (For under ground piping). 150mm
Providing and fixing gunmetal ISI marked obligue pattern fire hydrant valve with 80mm dia flanged inlet and 63mm dia instantaneous type female type lug and all accessories as per IS: 290-1983 'Type 'A' with hydrant matching flanges, gasket, nuts and bolts etc. complete in all respects. Single headed
Providing and fixing 63mm dia 15 Mtr. long flexible hose including gunmetal male and female instantaneous type coupling (IS: 903), machine wound with copper wire complete in all respects with ISI certification. RRL Hose pipe
Providing and fixing 63mm dia 15 Mtr. long flexible hose including gunmetal male and female instantaneous type coupling (IS: 903), machine wound with copper wire complete in all respects with ISI certification. CP Hose pipe
Providing and fixing of gun metal 63mm dia short branch pipe with 20mm dia nozzle, ISI marked (IS: 903).
Providing and fixing fire hose cabinet of size 900x600x300 fabricated from 16 gauge MS sheet of fully welded construction with hinged double front door with locking arrangements and partially glazed with 5mm thick glass stove enamelled fire red finish with fire hose written on front suitable to house 2x15 hose with couplings, one branch pipe (for external yard hydrants). Design to be got approved by Engineer-in-Charge before fabrication.
Providing and fixing first aid fire hose reel drum wall mounting swinging type fitted with 36 mtrs. 20mm dia high pressure rubber hose to IS: 5132 with 5mm outlet gunmetal nozzle with shut off valve (IS: 884).
Providing and fixing G.M. stop valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes. 25mm
Construction of brick masonary chamber 1200x1200 inside 75 class designation brick work in cement mortar 1:5 for sluice valve with CI surface box 400x400x75mm inside with hinged cover fixed in M-15 grade cement slab and necessary excavation foundation concrete 1:5:10 and inside plastering with cement mortar 1:3 finished with a floating coat of neat cement complete as per standard design with FPS bricks.
Providing and laying of hume pipe NP-2 class conforming to IS: 458 at road crosing with excavation, back filling, ramming and making good in all respects. 300mm
Providing and fixing cast iron slim seal wafer type non-return valve (as per IS: 5312) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects. 100mm
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 80mm
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 100mm
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 150mm
Providing and fixing gunmetal 2 way fire brigade connection head with 63mm dia instantaneous type inlet with built in check valves for fire brigade connection to fire risers (IS: 904-1965). A wall mounted box of MS construction with glass door to house the above mentioned components.
Providing and fixing portable fire extinguisher water type (gas cartridge) with cylinder fully charged of 9 litres capacity complete with standard discharged valve with tube CI bracket for wall mounting etc. conforming to IS: 940.
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 5 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 2171.
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 2878.
Providing and fixing portable fire extinguisher mechanical foam type with cylinder initially fully charged with foam compound of 9 litres capacity, complete with standard discharge valve with tube CI bracket for wall mounting etc. conforming to IS: 10204.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 25mm dia.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 65mm dia.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 80mm dia.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 100mm dia.
Providing, fixing, testing and commissioning of gun-metal ball valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes: 25mm dia.
Providing, fixing, testing and commissioning of 15mm dia horizontal (side wall type) bulb type sprinkler set to operate at 57 Deg. C (UL/FM/FOC/TAC listed/approved).
Providing, fixing, testing and commissioning of 15mm dia horizontal (extended side wall throw) bulb type sprinkler set to operate at 57 Deg. C (UL/FM/FOC/TAC listed/approved).
Providing, fixing, testing and commissioning pendent/upright of 15mm dia quartzoid bulb type sprinkler set to operate at 57 deg. C (UL/FM/FOC/TAC listed approved).
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 80mm dia.
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 100mm dia.
Providing and fixing M.S cabinet fabricated from 16 gauge M.S. sheet with double front glass door and locking arrangement with suitable shelves including space for 50 spare sprinkler and one spanner properly fixed in the shelves and cabinet painted with enamel paint of approved shade, size 900x600x150mm.
Providing and fixing installation control valve with turbine type automatic alarm gong with quarter mile hooter, also with control valve drain and test drive as per manufacturer's speicifcations. (Size 80mm dia).
Providing and fixing gunmetal 2 way fire brigade connection head with 63mm dia instantaneous type inlet with built in check valves for fire brigade connection to sprinkler system (IS: 904-1965). A wall mounted box of MS construction with glass door to House the above mentioned components.
Providing and fixing cast iron slim seal wafer type non-return valve (as per IS: 5312) including nuts, bolts 1.5mm thick CAF gasket sheets complete in all respects. 100mm
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. BN021C LED 20 PSU CW GR S2 [TL]
Supplying,installation,testing and commissioning of the following integral flood lighting luminaires conforming to IP 65 / IP 66 suitable for vertical and horizontal mounting applications pressure die cast powder coated aluminium alloy housing with corrosion resistance powder coating using nano Technology transparent injection moulded poly carbonate UV stabilized diffuser having high impact strength to withstand min IK09 with high power LED and unique flood optics to ensure uniform light distribution and maintenance free system ideal for area lighting, high mast lighting, sports lighting and billboard. The luminaires should be equiped with external surge protection device to withstand 10 KV / 5KV including connection with 2.5 sqmm 3 core PVC insulated round copper conductor as required and as directed by the department. BVP 120 LED 35 CW FG S1 PSU GR [CH ]
Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Supply, Fitting Fixing of Shock Treatment Chart
Supplying installation, testing and commissioning of electro hydraulic dock leveler serving as per detailed specification approved by the department and as under Location of the Dock Leveller - Loading Platform
A provisional sum of Rs 3,80,000.00 (Rupees Three Lakh Eighty Thousand Only) to be quoted by the bidder in the Basic Rate coloumn without changing the value of Rs 3,80,000.00 for unknown items of resettlement of existing temporary market sheds and EMP requirements beyond the provison of SOR is provided which shall be operated and expended in whole or in part at the instruction of Enginner-in-Charge
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .