Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹6.2 L+₹10,960.32 (1.81%)Accepted-Finance | L2 | Accepted-Finance ok | |
| 3 | L3₹6.6 L+₹60,080.16 (9.94%)Accepted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | L3 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹13,500
Closing Date
12 Mar 2020, 11:15 amClosed
Executive Engineer (EnM) WnS (WEST)
C-2A Block Janakpuri BPS New Delhi-110058.
Replacement of LT Panel and some Misc. Work at site Old Faridpuri BPS.
2020_DJB_189174_16
e-NIT No.29 / EnM (WEST)/ 2019-20
Open Tender
Miscellaneous Works
Works
15 days
C-2A Block Janakpuri BPS New Delhi
Please refer Tender Documents
3 documents required · 3 mandatory
₹500
Yes
DJB Account No. 50448339804
₹13,500
Yes
23 Mar 2020
4 Mar 2020
12 Mar 2020
4 Mar 2020
12 Mar 2020
4 Mar 2020
LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1800MM x1600x375mm. Having following components of approved make.
MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,400Amp with spreader & Handle - Make L&T/siemens
MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,125Amp with spreader& Handle Make L&T/Siemens
MCB Single pole 6Amp. Make L&T/Havells
MCB Triple pole 63Amp. Make L&T/Havells
MCB Triple pole 32Amp. Make L&T/Havells
PVC insulated copper flexible cable single core 25sq mm Make: Havells
Power capacitors 415V unit of 20Kvar Make: Epcos
Over load relay 66-110Make: L&T/siemens
Over load relay 6-10 Make: L&T/siemens
Digital Amp. Meter Make AE/L&T
Digital Volt Meter0-500V -Make AE/L&T
Motor protection Relay Make: L&T/Siemens
Power contactor 220V 3phase95Amp. Make L&T/siemens
Power contactor 220V 3phase70Amp. Make L&T/siemens
Power contactor 220V 3phase25Amp. Make L&T/siemens
Star delta timer on delay make: L&T/Siemens
Indicating lights LED type RYB & ON/OFF Make:-L&T/Havells
Current Transformer 250/5, 100/5, 30/5 Make AE /Advance
On load change over switch 200 Amp. Open execution type Make:- L&T
Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect.
Loading ,unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface for Installation of the panel at site on base frame ,laying of cable ,termination of cable both incoming & out going side
Testing & commissioning of panel, as per required parameters with relevant IS .testing of the panel prior to switching on as follow (i) contuinity and earth testing (ii) meggaring of all equipments for phase to phase, neutral to body, neutral to earth and Phase to earth (iii) Checking for all tightness of nut and bolts (iv) Alignment of doors etc (v) Interlocking tests. All function test
Excavation of Earth, approx 10' X 2' X 3' Deep dismantling of rusted demage suction line . Dismantling of Demage rusted M.S. suction line with the help of Gas cutter, electric-welding set. Job i/c refitting of New M.S. pipe, flange, M.S. Taper, Replacement of sluice valve, rubber packing, nut bolt etc. by the electric welding set, gas cutter, with the help of manual labour, Re-filling & levelling of Earth.
S/O M.S Black Pipe, Conforming to IS :1239 Gr 330 of 4.85 mm thick 100 mm dia Make:- Jindal/TATA
Supply of M.S. Flange 100 mm dia 15 mm thickness
Supply of 100 mm dia thickness 8 mm 90 degree double flange bend
Supply of C.I D/F non rising spindle sluice value PN :1.0, IS:14846,CI body / wedge / bronze- ring / ss 410 shaft- construction & SS IS:6603 Gr 12 Cr 12 of size 100 mm dia Make:- kirloskar / Ivc.
Supply of C.I D/F swing type non return value as per IS:5312(Part 1&2) PN1.0 CI body, door/Bronze to rubber rings/SS 410 Hinge pin construction of size 100mm dia Make:- kirloskor / Ivc
Supply of M.S. Nut bolts and washer of different sizes as per site requirements
Supply of Neoprene Rubber packing sheet
Painting of all the pipe line, pump and motor at site
Fitting of delivery pipe line and sluice valve & NRV with proper-alignment ,connection the motor from panel to starter replacement of pipe line ,flange , nut bolts , washer . the job include all tools and tackles, loading and unloading , safety equipments and other precautions etc. i/c Testing and commissioning of load and unload to complete satisfaction of Engineer In- Charge.
HYDROCON ENGINEERS
M G Traders and Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .