Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹28.9 L+₹70,121.90 (2.48%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Not Being lowest bidder | |
| 3 | L3₹29.0 L+₹73,583.38 (2.61%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest bidder |
| Sl No | Description | Qty | Unit | RAJENDER ENTERPRISES L3 | M/s Rohit Construction Co. L2 | J.D INFRA ENGINEERING L1 |
|---|---|---|---|---|---|---|
| 1.01 | Supply and fixing as in repairs LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB, CPRI approved, with IP-65 protection, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with double door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned below :- | 1 | Each | 1,84,000 ₹1,84,000 Lowest | 1,90,000 ₹1,90,000 | 2,20,000 ₹2,20,000 |
| 1.02Busbars:- TPN-1000 A, aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming:- (i) MCCB 4 pole , 415 V with MICROPROCESSOR release of capacity 630 Amps 36 KA - 01No (ii) CT's 600/5 -03 No with one selector switch . (iii)digital Ampere Meter 0 - 500 A with selector switch (v)digital Voltmeter with selector switch (vi) RYB indication lamps with toggle switch | ||||||
| 1.03Outgoing:- (i) MCCB, 4 pole 400 A, 35/36 KA -01 No (ii) MCCB, 4 pole 250 A, 35/36 KA -01 No (iii) MCCB, 4 pole 160 A, 25 KA -01 No (iv) MCCB, 4 pole 100 A, 16 KA -02No (v) Timer switch complete with contactor, timer, MCB etc - 01 Set Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. Note:- (i) A clear space of 200mm shall be kept from floor level for switchgear compartment. (ii) Each compartment shall be numbered / lettered as approved by GE. (ii) LT panel shall be fixed in PCC foundation as per manufacturer recommendation and the cost of the same shall deemed to be included in unit quoted rate. (iv) Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the bulk order | ||||||
| 2.01 | All as per serial item No. 1 here in before but with the following fittings & fixures :- | 2 | Each | 1,18,000 ₹2,36,000 | 1,15,000 ₹2,30,000 Lowest | 1,30,000 ₹2,60,000 |
| 2.02(i) MCCB, 4 pole , 35 KA , 400 Amps -01 No ( Incomming) (ii) MCCB , 4 pole , 35KA, 250 Amps -01 No (Out going) (iii) MCCB , 4 pole , 25KA, 160 Amps -02 No (Out going) (iv) Ammeter(0-500A), Voltmeter(0-500V)with necessary CTs with selectror switchs - 01set (V)Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 600 Amp for 3 phase and neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge | ||||||
| 3.01 | All as per serial item No. 1 here in before but with the following fittings & fixures :- | 1 | Each | 1,43,000 ₹1,43,000 Lowest | 1,45,000 ₹1,45,000 | 1,80,000 ₹1,80,000 |
| 3.02(i) MCCB, 4 pole , 35 KA , 400 Amps -01 No ( Incomming) (ii) MCCB , 4 pole , 24 KA, 160 Amps -02 No (Out going) (iii) MCCB , 4 pole , 16 KA, 63 Amps -04No (Out going) Timer switch complete with contactor, timer, MCB etc - 01 Set (iv) voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (v) Ameter of size 96 x96 mm ( 0-150A) with built in selector switch (vi) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 600 Amp for 3 phase and neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge | ||||||
| 4.01 | All as per serial item No. 1 here in before but with the following fittings & fixures :- | 3 | Each | 90,000 ₹2,70,000 Lowest | 1,00,000 ₹3,00,000 | 1,10,000 ₹3,30,000 |
| 4.02(i) MCCB, 4 pole , 35 KA , 250 Amps -01 No ( Incomming) (ii)MCCB , 4 pole , 16 KA, 63 Amps -04 No (Out going) Timer switch complete with contactor, timer, MCB etc - 01 Set (iii) Digital voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (iv) Digital Ameter of size 96 x96 mm ( 0-150A) with built in selector switch (v) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 500 Amp for 3 phase and neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge | ||||||
| 5.01 | Supply installation testing and commissioning in repair APFC PANEL 50KVAR (15KVAR x 2, 10KVAR x 2) Automatic power factor correction panel consisting of following
125A 433V 3P 50Hz 16KA Fixed Manual Type Moulded Case circuit breaker (MCCB) with thermal magnetic release for overload and magnetic shortcircuit (TMD) as Incomer for APFC.
APFC RVT Relay (RVT)
15 KVAR metallised polypropelen capacitor bank
10KVAR metallised polypropelen capacitor bank
Capacitor duty contactor for switching on & switching off 15 KVAR capacitor bank (MNx 32)
Capacitor duty contactor for switching on & switching off 10KVAR capacitor bank (MNx 25)
32A,3P,10KA MCB for protection of 30KVAR Capacitor Bank
25A,3P,10KA MCB for protection of 10KVAR Capacitor Bank
Note :- (i) The Quoted rate shall include construction of foundation/plinth of PCC 1:2:4 type B-2 all as per manufacturer's instruction and standard drawing. Height of foundation shall be 800mm out of which 500mm shall be above ground level | 1 | Each | 1,16,000 ₹1,16,000 | 1,20,000 ₹1,20,000 | 95,000 ₹95,000 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Oct 2025, 6:00 pmClosed
GE AF NAL
GE AF NAL
AS DESCRIBED IN BILL OF QUANTITIES
2025_MES_732181_1
GE (AF) NAL /T-40/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF NAL
AS PER NIT AND TENDER DOCUMENTS category b(I) and class D and above
9 documents required · 9 mandatory
₹500
GE AF NAL
₹70,000
Yes
25 Nov 2025
23 Sept 2025
22 Oct 2025
23 Sept 2025
20 Oct 2025
7 Oct 2025
23 Sept 2025 - 3 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TENDER_T40.pdf
Tender Documents • 1.76 MB
BOQ_819773.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .