| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.0 LAccepted-AOC 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹58.4 L+₹3.0 L (5.40%)Rejected-Finance | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹62.2 L+₹6.8 L (12.3%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹64.2 L+₹8.7 L (15.8%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹64.6 L+₹9.2 L (16.6%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
3 Nov 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT OF INTERNAL WIRING SUBMAIN WIRING SWITCH SOCKETS AND DBS OF OTM BLDGS IN RS AREA AT NAVY NAGAR AND REPAIR REPLACEMENT OF LIGHTENING CONDUCTOR AVIATION LIGHTS SERVICE CABLE AND ALLIED WORKS OF RS AREA AT NAVY NAGAR UNDER GE NW NAVY
2022_MES_555148_1
8103/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar
Class C
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.4 L
Yes
2 Jan 2023
29 Sept 2022
5 Nov 2022
29 Sept 2022
3 Nov 2022
20 Oct 2022
29 Sept 2022 - 18 Oct 2022
Amount
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling/floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin socket outlet, 5 Amps on the same board with other switches
One 3 pin socket outlet, 5 Amps, on the independent board
One bell point controlled by one push button
All as per item No 2.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch complete all as specified and directed by Engineer-in-Charge
Material and labour for wiring for circuit/submain wiring alongwith earth wire of sizes 2x4.0 sq. mm for phase and neutral and 1x2.5 sq. mm as earth wire 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories PVC insulated multisheathed single core multi stranded copper conductor complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement with electric bell ding dong, AC, 230V single pole complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as specified and directed by Engineer-in-Charge Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply and fixing in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as specified and directed by Engineer-in-Charge Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply and fixing in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply and fixing in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply and fixing in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply and fixing in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked complete all as specified and directed by Engineer-in-Charge. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and Supply and fixing in replacement with modular PVC Gang box of 12 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module complete all as specified and directed by Engineer-in-Charge. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
All as per Item No- 13.00 above but of modular PVC Gang box, 8 module.
All as per Item No- 13.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 13.00 above but of modular PVC Gang box, 4 module.
All as per Item No- 13.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 13.00 above but of modular PVC Gang box, 1/2 module.
Supply and fixing modular white cover plate with frame, 12 module.
Supply and fixing modular white cover plate with frame, 8 module.
Supply and fixing modular white cover plate with frame, 6 module.
Supply and fixing modular white cover plate with frame, 4 module.
Supply and fixing modular white cover plate with frame, 3 module.
Supply and fixing modular white cover plate with frame, 1/2 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab complete all as specified and directed by Engineer-in-Charge
All as per Item No-25.00 above but Slim LED integrated batten of 10 Watt 2ft complete all as specified and directed by Engineer-in-Charge
Taking down old existing unserviceable recessed mounting/hanging light fittings and Supply and fix LED box type pendant luminaires with efficient optics ensuring perfectly uniform illumination, optimised and unparalleled light distribution 20 Watt, 240V, 4ft CDL/NW. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings or suspension wire of 1.5 mtr is included (02 nos) for hanging with ceiling surfaces by fastener bolt as per site requirement and as specified and directed by Engr-in-Charge. The contractor shall provide test certificate from authorized lab.
Taking down old existing unserviceable recessed mounting/hanging light fittings and Supply and fix 1' x 4' LED luminaires CRCA housing, white powder coated, with polymer diffuser complete with all accessories suitable for recessed mounting 36 Watt, 240V, CDL/NW. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings or suspension wire of 1.5 mtr is included (02 nos) for hanging with ceiling surfaces by fastener bolt as per site requirement and as specified and directed by Engr-in-Charge. The contractor shall provide test certificate from authorized lab complete all as specified and directed by Engineer-in-Charge
Taking down old existing unserviceable recessed mounting light fittings and Supply and fix 1' x 1' LED luminaires CRCA housing with efficient optics ensuring perfectly uniform illumination, with polymer diffuser complete with all accessories suitable for recessed mounting 18 Watt, 240V, CDL/NW. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings as specified and directed by Engr-in-Charge. The contractor shall provide test certificate from authorized lab complete all as specified and directed by Engineer-in-Charge
Taking down old existing unserviceable recessed mounting light fittings and Supply and fix 2' x 2' LED luminaires CRCA housing with efficient optics ensuring perfectly uniform illumination, with polymer diffuser complete with all accessories suitable for recessed mounting 36 Watt, 240V, CDL/NW. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings as specified and directed by Engr-in-Charge. The contractor shall provide test certificate from authorized lab.
Taking out Old U/S and Supply and fixing of MCB TPN DB 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 100 A Copper Busbar for phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 DB's for provision for 63/100 MCB TPN as incomer and SP/TP MCB's as outgoing complete all as specified and directed by Engineer-in-Charge
Taking out Old U/S and Supply and fixing MCB DB SPN double door conforming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls complete all as specified and directed by Engineer-in-Charge
All as per Item No- 32.00 above but of MCB SPN DB 4 way complete all as specified and directed by Engineer-in-Charge
Taking out Old unserviceable and Supply and fixing MCB SPN, 32 Amp, 10 KA, 230 Volt complete all as specified and directed by Engineer-in-Charge
Taking out Old unserviceable and Supply and fixing MCB, single pole, upto 20 Amp, 10 KA, 230 Volt complete all as specified and directed by Engineer-in-Charge
Taking out Old U/S and Supply and fixing of MCCB DB VTPN 8 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100/125 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed by Engineer-in-Charge.
Taking out Old unserviceable and Supply and fixing of MCCB DB VTPN 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100/125 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed by Engineer-in-Charge
Taking out Old unserviceable and Supply and fixing of MCCB 100A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu complete all as specified and directed by Engineer-in-Charge
Taking out Old unserviceable and Supply and fix MCB SP 63A, 10kA, 240V complete all as specified and directed by Engineer-in-Charge
Taking out Old unserviceable and Supply and fix MCB TP 63A, 10kA, 415V. complete all as specified and directed by Engineer-in-Charge
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge
Taking out unserviceable exhaust Fan and deposit to MES Store, supply and replacement with exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connecting with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 45 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on complete all as specified and directed by Engineer-in-Charge. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
Supply and fixing in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable and Supply and fix On load change over switch in sheet metal enclousers 4 pole of capacity 63 Amp, 415 V, 50Hz including terminal shrouds, source separator and phase barriers conforms to IEC 60947-3 suitable for horizontal as well as vertical mounting on wall surface complete all as specified and directed by Engineer-in-Charge
All as per Item No- 46.00 above but of capacity 100 Amp, 415 V, 4 pole.
All as per Item No- 46.00 above but of capacity 200 Amp, 415 V, 4 pole.
Taking down old unserviceable and Supply and fix Plug and socket distribution box of CRCA sheet steel powder coated conforming to IS 8623-1 & 3, IEC 61439-1 & 3 for single phase, nuetral and earth of capacity 20 Amp, 240 V, 50Hz controlled by housed MCB SP 20 Amp, mounded/flushed on wall surfaces complete all as specified and directed by Engineer-in-Charge Note : MCBs shall be measured and paid separately under respective items.
All as per Item No- 49.00 above but for three phase and nuetral of capacity 32 Amp, 415 V, 4 pole controlled by housed MCB TPN 32 Amp.
Taking down old unserviceable and Material and labour for fixing of snap-on trunking system with cover, angles, bends and all fixing accessories and fittings of size 50x80 mm, on wall/ceiling surfaces and refixing of UG cables/submain inside the trunking and made connection complete all as specified and directed by Engineer-in-Charge. Make- Legrand Cat No-075601 or equivalent in Honeywell/Obo.
Taking out old existing unarranged submain cables/communications cable/conduits/casing caping from wall surfaces and keep a side and refixing the same after making good of wall surfaces under cable trunking/trays complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable and Supply and fix Isolator TPN 63A, 10kA, 415V. complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable and Supply and fixing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 25 sqmm 4.0 core on wall/ceiling surfaces by proper saddeling with GI clamp and accessories and made connection with existing DBs/Panels by fixing of suitable size cable glands complete all as specified and directed by Engineer-in-Charge
Material & labour for early streamer emission air terminal (Cirprotec NLP-2200) ESE lightning rod having corrosion resistant stainless chrome body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186, working on the principle of early streamer emission technology which will offer level 1 protection for up to 64 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to be protected including taking out old, U/S lightning rod complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno or approved by GE.
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitabe for mounting on building RCC roof with arrangement of neccessary anchoring and PCC including taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno or approved by GE.
Supply and fixing of digital electromechanical lightning even counter housed in weather proof resistance including taking out old, U/S copper strip complete all as directed by Engineer-in-Charge. Make- JEF Techno or as approved by GE.
Material and labour for air termination, single pointed aluminium rod, 12mm dia, 300mm long fixing over the GI Tube with the clamps after taking out old/unserviceable one all as specified and directed by Engineer-in-Charge
Supply and fixing Aluminium strip of size 25 x 3.15 mm fixed on walls/roof top with saddles and screws mounted suitable insulators after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge
Supply and fixing or embeded in to the PCC, Tubes medium grade galvanised, with all fitting, 40mm dia after taking out old/unserviceable one all as specified and directed by Engineer-in-Charge
Fixing only existing loose/hanged aluminium strip on wall/roof of high rise buildings up to 14 Floor with clamp, bracket complete all as specified and directed by Engineer-in-Charge
Material and labour for Comprehensive testing and checking of early streamer emission air terminal lightening protection system to be compliance as under : - ESE (Nimbus 2200) : (i) Check the physical appearance of Nimbus 2200 ESE. Note any arcing mark on the outer surface of NLP 2200. (ii) Testing efficiency of Nimbus 2200 ESE lightning arrester by using Test kit (Cirprotech). (iii) Provide the appearance and testing report of NLP 2200 Mast: (i) Physical appearance of mast (ii) Check the mast stability - Foundation fitness (Physical checkup) Down conductor : (i) Physical damage on down conductor (ii) Continuity of down conductor from ESE to Test link (iii) Check the down conductor termination - tightness and termination corrosion Test link : (i) termination physical check up for any damages (ii) Corrosion check up physically Counter : (i) Present reading from the counter will be noted and submitted to client (ii) Any physical damage in counter will be observed and details of observation to be submitted. Earth Pit : (i) Proper termination of Down conductor to earth pit (ii) Earth pit resistance value. To be maintained upto <1 ohm. If found higher then necessary steps to reduce the value will be suggested in comments
Supply & fixing of single core PVC insulated and PVC Innersheathed cable with aluminium conductor cable size 1x70 Sqmm 1100 Volt grade stranded aluminium conductor after taking out old, U/S earthing strip complete all as specified and directed by Engineer-in-Charge
Material and labour for PVC conduit pipe 25mm bore, medium mechenical stress for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+14 bldgs by proper clamping from roof to bottom complete all as specified and directed by Engineer-in-Charge
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or equivalent as approved by GE.
Material and labour for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge
Material and labour for Galvanised iron strip 25 x 4mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fixing test point terminal block for connecting the earth pit and down conductor or Aluminium strip, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw after taking out old/unserviceable one all as specified and directed by Engineer-in-Charge
Supply and fix weather proof hot pressed moulded PVC box with connector not less than 5x5 cm after taking out old one complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable aviation light fittings from roof surfaces of G+14 bldg and Supply & fixing of Twin LED aviation light 2 x 6 watt comprising of aluminium housing with polycarbonate diffuser, enclosed with glass cover in frame (with total lumen output not less than less than 100 lumens/Watt) with ingress protection IP 65 and surge protection device of 5 KV capacity etc incl necessary, angle iron supports , clamps etc for installation complete and testing on complete all as specified and directed by Engineer-in-Charge.
Material and labour for wiring for circuit/submain wiring alongwith earth wire of sizes 2x1.5 sq. mm for phase and neutral and 1x1.5 sq. mm as earth wire 1100 volts grade cable, FRLS, passing through PVC conduit including accessories PVC insulated multisheathed single core multi stranded copper conductor complete all as specified and directed by Engineer-in-Charge
NOEL ENGINEERS
Darpan Construction
AGRAWAL ASSOCIATES
SHREE JAGDISH FURNITURE CO.
Chakshu Enterprise
Genius Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .