Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 77 FORT VIEW COLONY NEAR KOTESWER TEMPLE ASRAM GWALIOR FORT RODE KOTESWER GWALIOR MADHYA PRADESH 474012 | GWALIOR | MADHYA PRADESH | 474012 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical EXPERIENCE CRITERIA NOT FULFILLED |
| 3 | Rejected-Technical MOTI MARKET LASHKAR JAYENDRA GANJ LASHKAR VILLAGE TOWN LASHKAR CITY GWALIOR GWALIOR MADHYA PRADESH 474009 INDIA | GWALIOR | MADHYA PRADESH | 474009 | Rejected-Technical EXPERIENCE CRITERIA NOT COMPLIED |
Tender Value
Refer Docs
EMD Value
₹23,998
Closing Date
6 Dec 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
2IC EXECUTIVE ENGINEER ELECT BSF ACADEMY TEKANPUR
OFFICE OF 2IC EXECUTIVE ENGINEER ELECT BSF ACADEMY TEKANPUR
Annual repair and maintenance of various capacity window split tower split ductabale ACs AHUs installed under BSF Academy Tekanpur for the year 2023 24
2023_BSF_782975_1
45/5178/NIT/ENGG/ELECT/2023-24
Open Tender
Electrical Works
Item Rate
365 days
BSF ACADEMY TEKANPUR
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹23,998
8 Dec 2023
29 Nov 2023
7 Dec 2023
29 Nov 2023
6 Dec 2023
29 Nov 2023
Amount
High pressure cleaning of various capacity Window / Split / Tower AC of all size by using high pressure water jet cleaning machine mixing of cleaning agents and AL-Cleanoil coil cleaning chemical altra shine i/c sundries and transportation charges of AC mechanic as required.
Onsite technical inspection for R/M of various capacity Window / Split / Tower AC of all size by AC mechanic with all required testing tools, Dismantling of defective PCB/ fan motor/ compressor/ capacitor/ contactor/ defective circuit/card and identification of fault i/c removal of defective part and deposit in engneering store i/c transportation charges of AC mechanic as required.
Providing and replacement of suitable capacity /size of fan motor for 1.5 ton / 2.0 ton Split/Tower AC including connecetion and testing etc as per requirement. ( Make : Carrier/LG/Voltas/Same specification make)
Providing and replacement of fan blade suitable for 1.5 ton / 2.0 ton Window/Split/Tower AC including fitting and testing etc as per requirement. ( Make : Carrier / LG / Voltas / Same specification make)
Providing and replacement of blower motor suitable for 1.5 ton /2.0 ton Window/Split/Tower AC including fitting and testing etc as per requirement. ( Make : Carrier/LG/Voltas/ Same specification)
Rewinding of fan motor i/c replacement of bush/bearing, shaft, oiling & greasing as reqd. for 1.5 ton /2.0 ton Split / Tower AC including connecetion and testing etc
Providing and replacement i/c dismentling and installation of PCB Circuit suitable for 1.5 ton /2.0 ton capacity as per requirement.
Testing/repiring i/c dismentling and installation of PCB Circuit suitable for 1.5 ton /2.0 ton capacity as per requirement.
Providing fixing/ replacement of heating /cooling sensor suitable for 1.5 ton /2.0 ton Window/Split/Tower AC as per requirement. ( Make : Carrier/LG/Voltas/Same specification make)
Providing /fixing of Air filter suitable for 1.5 ton /2.0 ton Window/Split/Tower AC as per requirement. ( Make : Carrier / LG / Voltas / Same specification make)
Providing and replacement of capacitor unit of 50MFD suitable for compressor of 1.5/ 2.0 Ton Window / Split / Tower AC making all connection & earthing. ( make : Havells/epcos/Tibcon)
Providing and replacement of capacitor 4mfd/6mfd suitable for 1.5 ton /2.0 ton capacity Split / window / Tower AC as per requirement (make : Havells/epcos/Tibcon)
Providing testing replacement including installation of 1.5 ton capacity compressor including suitable gas charging pipe welding etc as per requirement Compressor make : kirloskar/blue star/toshiba/hitachi/LG/Emerson/Danfoss
Providing testing replacement including installation of 2.0 Ton capacity compressor including suitable gas charging pipe welding etc as per requirement Compressor make : kirloskar/blue star/toshiba/hitachi/LG/Emerson/Danfoss
Providing and filling of fresh refrigerant (R-22/R-410/R-32 etc) suitable for 1.5ton/2.0 ton air conditioner as per requirement including Testing and Repair of leakage of 1.5 ton /2.0 ton capacity window/split/tower AC unit. etc as required
Providing and fixing of single phase contactor suitable for 1.5 ton /2.0 ton AC as per requirement
Providing and fixing of outdoor heating coil suitable for 1.5 ton capacity window/split/tower AC as per requirement
Providing and fixing of outdoor heating coil suitable for 2.0 ton capacity window/split/tower AC as per requirement
Providing and replacement of suitable capacity /size of outdoor fan motor for Split duct AC including connection and testing etc as per requirement.
Providing and replacement of outdoor fan motor blade suitable for Split Duct AC including fitting and testing etc as per requirement.
Providing and replacement of Filter Drier suitable for fixing in line with 5.5 tr compressor including fitting and testing etc as per requirement.
Providing and replacement of Expansion valve suitable for fixing in line with 5.5 tr compressor including fitting and testing etc as per requirement.
Rewinding of outdoor fan coil unit motor i/c replacement of bush, shaft, oiling & greasing as reqd. for Split duct AC including connecetion and testing etc
Providing testing replacement including installation of 5/5.5 ton capacity compressor including suitable gas charging etc as per requirement make : kirloskar/blue star/toshiba/hitachi/LG/Emerson/Danfoss
Providing and fixing of three phase contactor suitable for split Duct AC as per requirement
Providing and fixing of NO & NC Add-on block suitable for split Duct AC as per requirement
Replacement of defective PCB along with the remote control by the means of supplying and fixing the new PCB along with the remote control including connection and testing etc. as required. Make- Honeywell (T6861H2WB) / Seimens(RDF310.2/MM)
Providing testing replacement including installation of 12 ton capacity compressor including suitable gas charging etc as per requirement make : kirloskar/blue star /toshiba /hitachi/LG/Emerson/Danfoss
Providing and replacement of Filter Drier suitable for fixing in line with 12 Tr compressor including fitting and testing etc as per requirement.
Providing and replacement of Expansion valve suitable for fixing in line with 12 tr compressor including fitting and testing etc as per requirement.
providing and filling of Nitrogen gas cylinder for checking of leakage (7 cum capacity)
providing and installation of control panel including all necessary switchgears and control wiring for 16.5 tr AHU
providing and fixing of thermostat alongwith SPMS power supply and wireless connection switches I/C making all connection etc as reqd.
providing and fixing of Zero speed switch alongwith sensor unit for sensing RPM of outdoor unit of each compressor with adjustable ITD/NTD setting as per site condition and making all the connection with AHU controle panel for proper feedback of outdoor operation and command to commpressor etc at site as per site direction of engg in charge as reqd.
Providing of miscellaneous items for repair maintenance of AC's
Brazing Rod
Gas Torch
Valve 3/8
Dead nut
Copper pipe of 1/2 & 1/4 with insulation
Insulation 9 mm thick 2 mtr long
Packing Tape (2" width length 25-50 mtr)
V-Belt A 950 / A 36 (for blower motor of 16.5 Tr AHU)
Bearing 6203 2Z (for blower motor of 16.5 Tr AHU)
Bearing 6205 2Z (for blower motor of 16.5 Tr AHU)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .