Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹19.7 L+₹5.0 L (34.2%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹20.1 L+₹5.4 L (36.7%)Admitted-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Not fulfilling the criteria as stipulated in NIT and MoC 2020 for fresh Enlistment |
| Sl No | Description | Qty | Unit | M/S J J ENTERPRISES L2 | M/S SHARADA ASOCIATE L3 | SV ASSOCIATE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Repairs/ comprehensive maintenance of VRF plants of DAIKIN make of capacity ranging from 12 to 20 HP (i.e 36 HP -02 Nos and 44 HP - 03 Nos) having various outdoor units of following capacity round the clock including maintaining the plants twenty four hours for desired temperature of 21+/-3 degree celcius without interuption including repairs/ replacement of damaged/ unserviceable minor/major all types of parts i.e controlling valves, copper tubings, nitrile rubber insulation, and all electrical/ electronics components, control wirings, sensors,Thermistors, thermocol inner packs,indoor/ outdoor fan motor windings, vibration pads, condensor Coil, PCB, Drain Pump, Blower, Motor, expansion Valve, addressing Board , Remote controller, Cooling Coil, Refrigerant Piping as per existing size, painting of rusted out door stands and connected accessories, drainage lines, pre filters control/ communication wirings, earthings, leak test, accessories of LT control panel and all other accessories not mentioned in this schedule complete all as specified and directed.
(a) Out door unit of capacity 20 HP -02 Nos. | 11 | PER MONTH | 22,000 ₹2,42,000 | 22,500 ₹2,47,500 | 18,000 ₹1,98,000 Lowest |
| 1.01 | (b) Out door unit of capacity 18 HP -04 Nos. | 11 | PER MONTH | 23,000 ₹2,53,000 | 22,500 ₹2,47,500 | 20,000 ₹2,20,000 Lowest |
| 1.02 | (c) Out door unit of capacity 12 HP - 04 Nos. | 11 | PER MONTH | 22,000 ₹2,42,000 | 22,500 ₹2,47,500 | 20,000 ₹2,20,000 Lowest |
| 1.03 | (d) Four way casette type indoor Unit of any capacity -78 Nos. | 11 | PER MONTH | 25,000 ₹2,75,000 Lowest | 25,000 ₹2,75,000 Lowest | 25,000 ₹2,75,000 Lowest |
| 1.04 | (e) Split hi wall type indoor unit of any capacity -16 Nos . | 11 | PER MONTH | 13,000 ₹1,43,000 | 13,500 ₹1,48,500 | 4,000 ₹44,000 Lowest |
| 1.05Notes for Items No 1 to 1.04 :- (a) AC Mechanic skilled- 01 No (duly trained) has to attend MES AC/VRF plant complaint cell for all VRF units mentioned above for attending to the complaints on daily basis and shall report to the concernJE/ Engr-in-charge at the AC/VRF complaint cell for receiving the complaints. AC mechanic shall be responsible to rectify the minor faults, routine cleaning, dry servicing of plants & filters and routing cleaning of plants area. Wet servicing of whole plants (IDU & ODU) should be carried by the contractor on monthly basis and any number of helper required for his assistance shall be provided by contractor and the cost of all above requirements shall deemed to be included in quoted rates. b) The contractor shall ensure that visit of OEM manufacturer Engineer on monthly basis and report/ servicing of outdoor units which shall be submitted to this Office. The charges for all OEM procedures shall deemed to be included in the quoted rates. The reports of OEM Engineer shall be produced before submitting RARs. (c) AC mechanic must be experienced in VRF Plants and capable of carrying out any type of maintenance or attending breakdown in above mentioned plants. (d) Incase of any breakdown, the additional man power if required will be arranged by the contractor without any price adjustment. Any breakdown shall be attened within 24 hrs & rectified within 48 hrs failing to which a penalty of Rs. 2500/- per day will be imposed. (e) The cost of replacement of all minor/major parts which are not mentioned in schedule 'A' shal deemed to be included in the quoted rates under item No 1 to 1.04. | ||||||
| 2.00 | Supply and fix Compressor for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 1 | EACH | 1,80,000 ₹1,80,000 | 1,75,000 ₹1,75,000 | 75,171 ₹75,171 Lowest |
| 3.00 | Supply and fix Control Board , for Out door units according to the existing cat pt no. of VRF 12 to 20HP Unit including testing complete all as specified and directed. | 3 | EACH | 35,000 ₹1,05,000 | 37,000 ₹1,11,000 | 15,550 ₹46,650 Lowest |
| 4.00 | Supply and fix MNET Board, for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 3 | EACH | 13,000 ₹39,000 | 12,500 ₹37,500 Lowest | 16,300 ₹48,900 |
| 5.00 | Supply and fix Noise filter for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 3 | EACH | 14,000 ₹42,000 | 15,000 ₹45,000 | 6,500 ₹19,500 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
26 Aug 2026, 6:00 pmClosed
SHRI DARSHAN KUMAR, EE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTENANCE OF SPARE PARTS INCLUDING ANNUAL MAINTENANCE CONTRACT AND OTHER CONNECTED WORKS FOR VARIABLE FREQUENCY DRIVE AT VAYUSENA NAGAR NAGPUR
2026_MES_762097_2
8822/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹40,000
21 Sept 2026
4 Aug 2026
28 Aug 2026
4 Aug 2026
26 Aug 2026
11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairs/ comprehensive maintenance of VRF plants of DAIKIN make of capacity ranging from 12 to 20 HP (i.e 36 HP -02 Nos and 44 HP - 03 Nos) having various outdoor units of following capacity round the clock including maintaining the plants twenty four hours for desired temperature of 21+/-3 degree celcius without interuption including repairs/ replacement of damaged/ unserviceable minor/major all types of parts i.e controlling valves, copper tubings, nitrile rubber insulation, and all electrical/ electronics components, control wirings, sensors,Thermistors, thermocol inner packs,indoor/ outdoor fan motor windings, vibration pads, condensor Coil, PCB, Drain Pump, Blower, Motor, expansion Valve, addressing Board , Remote controller, Cooling Coil, Refrigerant Piping as per existing size, painting of rusted out door stands and connected accessories, drainage lines, pre filters control/ communication wirings, earthings, leak test, accessories of LT control panel and all other accessories not mentioned in this schedule complete all as specified and directed.
(a) Out door unit of capacity 20 HP -02 Nos. | 11 | PER MONTH | - | - |
| 1.01 | (b) Out door unit of capacity 18 HP -04 Nos. | 11 | PER MONTH | - | - |
| 1.02 | (c) Out door unit of capacity 12 HP - 04 Nos. | 11 | PER MONTH | - | - |
| 1.03 | (d) Four way casette type indoor Unit of any capacity -78 Nos. | 11 | PER MONTH | - | - |
| 1.04 | (e) Split hi wall type indoor unit of any capacity -16 Nos . | 11 | PER MONTH | - | - |
| 2 | Supply and fix Compressor for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 1 | EACH | - | - |
| 3 | Supply and fix Control Board , for Out door units according to the existing cat pt no. of VRF 12 to 20HP Unit including testing complete all as specified and directed. | 3 | EACH | - | - |
| 4 | Supply and fix MNET Board, for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 3 | EACH | - | - |
| 5 | Supply and fix Noise filter for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 3 | EACH | - | - |
| 6 | Supply and fix Fan board for Out door units according to the existing cat pt no. of VRF 12 to 20 HP Unit including testing complete all as specified and directed. | 3 | EACH | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.19 MB
BOQ_876741.xls
BOQ • 0.45 MB
TENDERDOCS8822.pdf
Tender Documents • 0.31 MB
CRIEDIT8822RETENDER.pdf
Tender Documents • 0.05 MB
8822CORRIGENDUM.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .