Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-Finance | ₹1.2 Cr | L1 | Accepted-Finance Being Lowest Bidder |
| 2 | L2₹1.3 Cr+₹3.1 L (2.49%)Accepted-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | ₹1.3 Cr+₹3.1 L (2.49%) | L2 | Accepted-Finance 2nd lowest bidder |
| 3 | L3₹1.4 Cr+₹18.1 L (14.7%)Accepted-Finance 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | ₹1.4 Cr+₹18.1 L (14.7%) | L3 | Accepted-Finance 3rd lowest bidder |
| 4 | L4₹1.5 Cr+₹23.4 L (18.9%)Accepted-Finance | ₹1.5 Cr+₹23.4 L (18.9%) | L4 | Accepted-Finance 4th lowest bidder |
| 5 | L5₹1.6 Cr+₹41.1 L (33.2%)Accepted-Finance | ₹1.6 Cr+₹41.1 L (33.2%) | L5 | Accepted-Finance 5th lowest bidder |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
12 Sept 2020, 6:00 pmClosed
Arun Kumar Sharma
D3-18, 3rd Floor, RHQ, NR, AAI Operational Offices, New Delhi-110037
RMO of Int. and Ext. E.I., Power Supply system i/c Transformer, HT/LT Panel, AMF Panel, DG Sets, Fire Hydrant, Wet Riser, Fire Alarm and Detection system, Water Supply pumps, Airconditioners, Water Coolers at AAI Operational Offices, New Delhi
2020_AAI_51766_2
AAI/RHQ/NR/OC-ARMO/2020-22/02
Open Tender
Electrical Works
Item Rate
730 days
AAI Operational Offices, RHQ, NR
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,120
Airports Authority of India
₹3.9 L
29 Dec 2020
4 Sept 2020
17 Sept 2020
5 Sept 2020
12 Sept 2020
5 Sept 2020
5 Sept 2020 - 7 Sept 2020
Amount
Operation & Maintenance of 11KV/415V Sub-station equipments i/c HT Panel, Transformers, D.G. Sets (2x380 KVA & 2x500 KVA Cummins make), MV Panels & 02 nos. Submersible Pumps located at AAI Operational Offices by deploying following manpower on days as described below including tools & tackles and attending the break-down and preventive maintenance as per Conditions of Contract complete as required:- (Note:- (1) Contractor has to depute the required staff on days as mentioned below & (2) Contractor has to provide Reliever on Weekly Off / Holidays as mentioned below)
Electrician cum Operator - Skilled - 06 Nos. (i.e. 02 Nos. round the clock on all days in week & Reliever Shall be Provided on Weekly Off).
Helper - Unskilled - 09 Nos. (i.e. 03 Nos. round the clock on all days in week & Reliever shall be provided on Weekly Off).
Electrician cum Operator - Skilled - 01 No. (in general shift on all working days except Sunday)
Helper - Unskilled- 02 Nos. (in general shift on all working days except Sunday)
Extra Manpower for misc. works in case of any emergency for following type of manpower as & when required basis :-
Electrician (Skilled)
Khallasi (Unskilled)
Testing of Dielectric strength (BDV) of Transformer oil on yearly basis for 02 nos. 2000 KVA transformers and submission of report from government approved laboratory, including collection of sample from site, transfer to lab complete as required.
Dehydration & Filtration of Transformer oil with High Vaccum Filtration Machine to achieve BDV up to the level of relavent IS Dielectric strength as required including submission of oil test reports from government approved laboratory after dehydration of oil as and when required.
Supply and Toping up the transformer oil in conservator tank upto a required level with new treated transformer oil (including replacement of oil seal) as and when required.
Preventive maintenance, servicing, testing & calibration of the below mentioned different rating LT Air Circut Breakers (L&T make and C&S make) on yearly basis complete as required through OEM/Authorised service dealer as per OEM recommended standards including submission of test/maintenance report.
For First Year - 800 A, ACB, 415 V
For First Year - 2500 A, ACB, 415 V
For First Year - 3200 A, ACB, 415 V
For Second Year - 800 A, ACB, 415 V
For Second Year - 2500 A, ACB, 415 V
For Second Year - 3200 A, ACB, 415 V
Lifting & lowering of submersible pump along with column pipe, detaching one length of column pipe from rest of column pipe by opening nut & bolts in this manner taking out entire pump system & lowering of entire pump system in reverse order of above process including chain block & supporting pipes including complete installation, transportation, testing & commissioning/de-commisioning etc. complete as required.
Rewinding of following pump motors etc. as & when required with super enemelled copper winding wire, varnishing including greasing replacement of bearings/Bush, thrust support plate, repairing /replace of shaft including transporatation charges completed as required. (Dismantle material belongs to the contractor)
5.0 HP, 3 Phase Submersible Pump
7.5 HP, 3 Phase Submersible Pump
Supply & replacement of following consumable as and when required:-
Single Phase Preventer (VSP-2, 415V).
Operation & Maintenance of Int. & Ext. Electrical Installations at AAI Operational Offices, Rangpuri, New Delhi. The person attending the complaints shall note down the complaint from complaint register for immediate follow up action by arranging the store & deputing the staff for maintenance with following minimum manpower on days as described below incluing tools & tackles and attending the break-down and preventive maintenance as per Conditions of Contract complete as required: (Note:- 1. Contractor has to depute the required staff on days as mentioned below & 2. Contractor has to provide Reliever on Weekly Off / Holidays as mentioned below)
Supervisor - Highly Skilled - 01 Nos. (in general shift on all working days except Sunday)
Electrician - Skilled - 02 No. (in general shift on all working days except Sunday).
Rewinding of following fans with super enemelled copper winding wire including varnishing, changing of bearing, bush, oiling & greasing, assembling testing, transportation charges etc. complete as & when required.
Ceiling Fan upto 1400mm as & when required
Pedestal Fan upto 450 mm as & when required
Wall Mounted Fan upto 450mm as & when required.
Exhaust fan upto 450 mm as & when required.
Supplying of following size of PVC casing and capping as per AAI approved make list as required:-
20mm x 12mm
25mm x 16mm
Supply of 3.15 mfd Capacitors for fans as per AAI approved make.
Supply of 2.0 mfd Capacitors for fans as per AAI approved make
Supply of 18/20 watt Extruded Aluminium Retrofit LED Tubelight complete as required as per AAI approved make.
Supply of Tubelight Holder.
Supply of Uni. 20A & 10A Switch Socket combined unit box as per AAI approved make suitable for operation on 230 V, 50Hz, Single Phase, AC supply.
Supply of MCB TPN 'C' Series 63 A, 10 KA as per AAI approved make 'C' Series with short circuit fault indicator and suitable for operation on 240 V, 50Hz, 10kA, Single Phase, AC supply.
Supply of Flame Retardant PVC insulated single core copper conductor (flexible) cable suitable upto 1100V grade conforming to IS:694/1990 with latest amendments of AAI approved make of following size and coil length:-
1 x 1.5 sqmm (90 meter coil of each)
1 x 2.5 sqmm (90 meter coil of each)
1 x 4.0 sqmm (90 meter coil of each)
Supply of PVC insulated & PVC round sheathed copper conductor (flexible) industrial cable (multicore), 1100V conforming to IS:694/1990 with latest amendments of AAI approved make of following size :
3 x 1.5 sqmm (90 meter coil of each)
3 x 2.5 sqmm (90 meter coil of each)
3 x 4.0 sqmm (90 meter coil of each)
Supply & installation of SR18G microprocessor based protection release suitable for 800 A/ 2500 A/3200 A rating LT Air Circut Breakers (Make- L&T) complete as required.
Supply of following battery in charged condition in Buy back of following capacity of AAI approved make:-
Lead Acid battery Maintenance Free with at least 02 years warranty, 12 V, 150 AH or equivalent suitable for 380 KVA DG sets.
Lead Acid battery Maintenance Free with at least 02 years warranty, 12 V, 180 AH or equivalent suitable for 500 KVA DG sets.
Lead Acid Battery each having 2V, 100AH capacity suitable to form a battery bank for HT Auxillary circuit with at least 01 year warranty.
Operation & Maintenance of Fire Hydrant & Wet Riser system including main pumps, jockey pumps, diesel engine with pump and water supply pumps installed at AAI Operational Offices, New Delhi by deploying following manpower on days as described below incluing tools & tackles and attending the break-down and preventive maintenance as per Conditions of Contract complete as required:- (Note:- 1. Contractor has to depute the required staff on days as mentioned below & 2. Contractor has to provide Reliever on Weekly Off / Holidays as mentioned below)
Electrician Cum Operator - Skilled - 03 Nos. (i.e. 01 No. round the clock on all days in week & Reliever Shall be Provided on Weekly Off).
Maintenance of 90 BHP Fire Engine of Kirloskar make from OEM or its Authorised Dealer by conducting periodical preventive maintenance checks, 02 Nos. 'B' checks (including supply and installation of B-check spares) per year at an interval not exceeing 06 months as well as inparting necessary guidelines for conducting routine maintenance in conformity to the recommended service manual/instruction of the OEM, comprising of regular visits (at least 01 per month) by an authorised factory trained Service Engineer & attending the breakdown calls etc. complete as & when required at site complete as required for following two years.
For 1st Year (Maintenance & Monthly Visit)
Supply & installation of B-check Spares for 1st Year
For 2nd Year (Maintenance & Monthly Visit)
Supply & installation of B-check Spares for 2nd Year
Operation & Maintenance of Apollo based Addressable Intelligent Fire Alarm & Detection System comprising of panel with upto date Softwares, Card, Detectors, Batteries, Conventional Fire Alarm Panel, Fire Exit Signage, complete circuit & loop wiring etc. i/c all other associated accessories/ spares for satisfactory operation & making system serviceable, periodically cleaning & testing of Panels, Detectors, Manual Call Points, Response Indicators, Hooter etc. in confirming to OEM specifications, attending the breakdown/faults, checking serviceability & preventive maintenance by providing following manpower in general shift for operation & maintenance of the system upto the satisfaction of Engineer-in-Charge. (Note:- 1. Contractor has to depute the required staff on days as mentioned below & 2. Contractor has to provide Reliever on Weekly Off / Holidays as mentioned below):- (a) Fire Technician/Electrician - Skilled - 03 Nos. (i.e. 01 No. round the clock on all days in week & Reliever Shall be Provided on Weekly Off).
Supply of following materials/spares of AAI Approved make and suitable as per site requirement as and when required:
Addressable smoke detector suitable for Apollo Adressable Fire Alarm Panel with builtin LED and mounting base
Apollo Addressable intelligent addressable programmable sounder
Apollo Addressable Manual Call Point
Apollo Addressable Control cum Monitor Module
Apollo SR-65 Smoke Detector with base
Hooter
Conventional Manual Call Point
12V, 7AH Batteries for Existing Fire Panels.
Replacement of LED Fire Exit Signages with existing signages complete as and when required.
Supply of dual loop expansion card suitable for Apollo based Addressable Fire Alarm Panel, Model: Series 6000 as and when required.
Supply of 08 Zone Motherboard with power supply and battery charger for conventional softchip panel as and when required.
Operation & All inclusive Comprehensive Maintenance (AICMC) for the following type & rating of AC units incl. inverter & non inverter ACs of all makes including repair/replacement of all parts like fan motor, capacitor, PCB, supply/ charging/ topping/ replacement of refrigerant also including repair/replacement of faulty compressor as and when required, incluing tools & tackles and attending the break-down and preventive maintenance as per site requirement by deputing 01 No. Skilled AC Technician in general shift on all working days except Sundays complete as required:-
1.5/2.0TR Window type Airconditioners-72 Nos. Rate for First Year
1.5/2.0TR Window type Airconditioners-72 Nos. Rate for Second Year
1.5/2.0 TR Split type Airconditioners-38 Nos. Rate for First Year
1.5/2.0 TR Split type Airconditioners-38 Nos. Rate for Second Year
2.0 TR Cassette type Airconditioners- 21 Nos. Rate for First Year
2.0 TR Cassette type Airconditioners- 21 Nos. Rate for Second Year
3.0 TR Tower/Cassette type Airconditioners - 08 Nos. Rate for First Year
3.0 TR Tower/Cassette type Airconditioners - 08 Nos. Rate for Second Year
4.0 TR Cassette type Airconditioners - 10 Nos. Rate for First Year
4.0 TR Cassette type Airconditioners - 10 Nos. Rate for Second Year
Comprehensive Maintenance of 12 nos. Water Coolers of capacity upto 150/150 Ltrs. of all makes i/c repair/replacement of all parts including compressor, gas charging, plumbing work, cleaning of water tank etc. as required (Starting from March 2021)
I.T.C. of Window type AC units including supply and fixing of wooden frame complete as per site requirement.
I.T.C. of Split type AC units including complete copper supply & return piping/insulation, gas charging etc. complete as per site requirement.
Supply & replacement of decorative front grill of all makes and as per site requirement for Window type AC units complete as required.
Providing & installation of insulation on existing refrigerant piping along with protective PVC tape, clamping including dismantling of existing insulation etc. for Split AC units complete as per site requirement.
DSR Items Percentage above/below CPWD Schedule of Rates for E&M (2018) works totaling to Rs.5,00,000/- (Item to be executed as per the site requirement) (All DSR items Rate to be taken excluding GST)
CIS GLOBAL INFRATECH PRIVATE LIMITED
NATIONAL SAFETY ENGINEERS
SRS ENGINEERS
S. N ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .