Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC 101 103 KARNALGANJ KANPUR | L1 | Accepted-AOC Lower rate | |
| 2 | L2₹8.3 L+₹2,617 (0.32%)Rejected-AOC 577 C BLOCK YASHODA NAGAR YASHODA NAGAR KANPUR NAGAR UTTAR PRADESH 208011 | KANPUR NAGAR | UTTAR PRADESH | 208011 | L2 | Rejected-AOC Higher Rate | |
| 3 | L3₹8.7 L+₹43,989 (5.34%)Rejected-AOC | L3 | Rejected-AOC Higher Rate |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
18 Aug 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Electricity Construction Div., RPH, Kesco., Kanpur
Attending Breakdown all complete work etc. under EUDC-I, Kesco., Kanpur
2020_KESCO_489735_2
14/Const./2020-21
Open Tender
Construction Works
Item Wise
365 days
EUDC-I, Kesco, Kanpur
Please refer to tender document
2 documents required · 2 mandatory
₹1,180
Kesco
₹10,000
5 Nov 2020
31 Jul 2020
18 Aug 2020
1 Aug 2020
18 Aug 2020
1 Aug 2020
180 days
Repairing of damage of H.T./L.T. S.T. Pole comprising following works:-
Opening the binding for taking out the conductor and dismantling the concern X-arm/bracket from pole/rail.
Taking out the damaged pole from ground by digging the pit or by cutting with gas cutter and its proper stacking.
Repairing of damaged S.T. Pole by providing M.S. Angle 50x50x6mm, 3 Nos. each of 1 meter long by clamping at 2 points and its welding including its all related work.
Erection of old/new S.T. Pole size 9.0 Mtr. to 13.00 Mtr. including digging of Pit back filling and ramming.
Dismentalling of damaged S.T. Pole of very critical position with the help of crane after removing all the accessories from damaged pole and its all related work including digging of pit or by cutting with gas cutter.
Mounting of New/old H.T./L.T. X-arm/bracket on the pole/rail.
Dismounting of 33KV/11KV pin insulator and G.I. Pin on the pole after opening of binding.
Repairing of 33/11KV damaged X-arm and proper shaping including drilling of holes whatsoever is required with the help of gas healing and welding.
Laying, stringing, tensioning & binding ACSR dog conductor for 3Ø 3 wire 33KV O.H. line.
Resagging of conductor on old/new line after replacement of damaged pole/erection of new pole and all related work.
Dismounting of damaged disc insulator of disc insulator string after replacement of damaged insulators including, removing of conductor from disc fitting.
Mounting of 33/11KV Pin insulator with G.I. Pin including binding of conductor with insulator.
Fixing and grouting of stay rod including digging of pit, binding of stay wire and its all related work including cost of cement.
Dismentalling of Aearail Bunched Cable from L.T./H.T. O.H. (damaged) line.
Loading, Carriage and unloading of Aearial Bunched Cable (HT/LT) from store to work site and vice-versa.
Laying of Aearial Bunched Cable for Erection of L.T./H.T. O/H Line.
Mounting and erection of Single Phase Distribution box.
Mounting and erection of Three Phase Distribution box.
Opening and reconnection of consumer connection for shifted/replaced of pole.
Fixing of angle/guarding channel on S.T. Pole/Rail Pole for laying of guarding.
Laying, Stringing, tensioning and final sagging of Earth Wire/G.I. wire.
Cross lacing of guarding by G.I. wire (approximate 5 lacing of each span)
Fabrication and erection of Distribution T/F fencing of frame size 3x2.4 Mtr. including cost of M.S. Angle size 40x40x5 and M.S. Flat size 35x5, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil & dust.
Taking out new/old cable from cable drum and then after transportation from store to work site or vice-versa.
H.T. Cable
L.T. Cable
A.B. Cable of different size.
Digging of cable trench in size of 30 cm wide and 60 to 90 Cm meter deep as per site requirement for laying of cable-
Normal Soil
Kharanja Road
Metallic Road
Tiles Road
Laying of cable in the above digging, trench, covering with bricks, sand and back filling.
H.T. Cable
L.T. Cable
Laying of H. T. cable through Hume/C.I./MS. pipe in digged trench and back filling.
H.T. Cable
L.T. Cable
Taking out (old & used) H.T. cable by digging of trench from site and then rolling in to bundles.
H.T. Cable
L.T. Cable
Laying, stringing, tensioning & final sagging of 33 KV/11 KV XLPE Cable (Size 3x50 to 3x300 Sq.mm) pole to pole as O/H line.
Laying of Cable through trench less method (HDD) without HDPE Pipe
Laying of L.T. Cable through moling method.
Restoration of Metallic/RCC road after proper repairing with appropriate materials.
Making of HT AB Cable box/cable box for 33 KV/11 3x50 to 3x300 mm2 for XLPE/PILCA cable (Jointing kit will be provided by Kesco.)
Mounting of 11 KV HT AB Cable box/ 33 KV/11 KV cable box on pole as well as on H.T.P.B./Outdoor Metering Cubical/H.T.M.C. the work includes proper clamping of cable box on both ends.
Without pipe
Making Plinth for H.T.P.B. By brick work in size of 1.2x1 .2x1.0 meter as well as plastering of 12 mm thick on all the exposed sides of the plinth.
Loading, Carriage and unloading of H.T.P.B. form store to work site and then after erection on the relay constructed plinth.
Providing and erection of HTPB/LTPB and making its plinth by brick work size 1.2x1.2x1 Mtr including 11 mm thick plastering on all exposed sides of the plinth.
Making Plinth for L.T. P.B. By brick work in size of 1.2x0.75x1.0 meter as well as plastering of 12mm thick on all the exposed sides of the plinth.
Distribution T/F work
Loading, carriage & unloading of distribution Transformers (Up to 630 K.V.A.) from store to site & vise-versa.
Erection of Distribution T/F on plinth/D/pole structure.
Connection of H.T. Jumper from fuse set to H.T. Busing of the transformer.
Fitting of L.T. D.B. by brackets & clamps on double pole structure & L.T. Cable Connection from T/F bushing to L.T.D.B.
Connection of L.T. cable from L.T.D.B to L.T.O.H.
Erection of O/D type Metering unit :-
Loading, carriage & unloading of O/D type metering unit from store to site & vice-versa.
Erection of O/D type Metering unit on D/P Structure.
Connection of H.T. Jumper to HT Bushing of O/D type Metering unit.
Making of 11 KV H.T. Section points by brackets, clamps & Insulator, tightening of Line, binding of conductor & proper connection.
Disconnection of H.T./L.T. Lines, Shifting of T/F from ground to a safe place for construction of T/F plinth.
Shifting of T/F from ground to plinth and re-connection of H.T. L.T. Lines as well as earthing for proper completion.
Stringing of H.T./L.T. Cable in different sizes as same as H.T./L.T. overhead line :
Single Core L.T. Cable
3 ½ Core L.T. Cable
11 KV H.T. Cable
Supply of 40mm dia Class 'B' G.I. Pipe 40' long including M.S. flat 50x6 mm along with all related materials required for distribution T/F earthing work.
Boring 39' deep & connection of neutral bushing with G.I. Pipe through M.S. flat/earth wire with proper connection arrangement.
Providing of one jeep gang with T & P on duty on special accessories.
Providing one pedal gang with T & P on duty on special accessories.
Construction of T/F plinth, suitable for mounting of distribution transformer. Size of the plinth will be 1.2 x 1.2 x 1.2 meter solid with brick work. 75 mm thick C.C. in ratio 1:4:8 with cement, coarse sand and brick ballast laid on the base and 75 mm thick done on all the exposed sides to the plinth.
Dismentalling of 11 KV TPMO from existing Double pole.
Erection of 11 KV TPMO on Double pole.
Attending L.T. defective Air Circuit Breaker to make it functional by making adjustment in alignment or by replacing defective MCCB (MCCB will be provided by Kesco.).
Attending defective L.T. A Panel/B Panel of under ground cable network either by making proper adjustment or replacing defective part other than MCCB.
Earthing of support by sagging of M.S. earthing rod 20mm and connecting with earth wire and related work.
Laying of control cable including digging of trench and back filling.
Dismentalling of damaged 33 KV O/D Type C.T./P.T. from structure, dismentalling of wiring and earthing and its all related work.
Mounting of 33KV O/D Type C.T./P.T. on erected structure in proper position its wiring and earthing and its all related work.
Dismentalling of damaged 33KV lighting arrestors from structure and its all related work as opening of clamps etc.
Mounting of 33KV lighting arrestor on erected structure including its re-fabrication for matching holes, mounting in proper alignment itsearthing and its all related work as connecting to lower bus-bar.
Fabrication of earth electrode from 36mm/40mm M.S. Round bars 3 meter long making one end pointed upto 15cm. including cutting of round bar.
Erection of earth electrode 36mm/40mm by making pit of size 2’x2’ then pegging the earth electrodes with filling the pit with water and hammering the electrodes by hammer upto 0.5 meter proper below ground level.
Earhting of yard/structure/S/G with M.S. Flat 50x6mm connecting with main Mate/Risers/Earth electrodes after its bending shaping and welding the strip including cost of M.S. Flat.
Chopping of tree branches lying in the route of existing line touching the tree branches to the phase line conductor making fault to the feeder, for 3” to 18” dia or as per requirement of site.
Carriage of following stock materials from store to site of work as and when required or back to store from site (Old and damaged material):-
S.T. Pole 9.0 meter to 13.00 meter.
M.S. Rail 10.0 Mtrs. To 13.0mtr.
33KV Lighting arrestors
33KV C.T./P.T. Outdoor Type
33KV Isolator
33KV Metering Cubical
11KV Switchgear Panel
33KV M.O.C.B/V.C.B./I.D. Panel
33KV Control Relay Panel
Repairing of 33 KV Old Isolator by replacing the jaws and blades or by oiling and greasing of moving parts or by adjustment of moving mechanism or by leveling the whichever is required for smooth operation of isolator and its all related work.
Dismentalling of old and damaged 33KV Isolator from structure by cutting the old bolts and nuts and removing all mechanism with the help of Gas Cutter. It includes removing of jumpers with Isolator clamps and all related work.
Erection of 33KV Isolator on erected Isolator structure in proper alignment fitting its complete moving mechanism its proper adjustment, leveling and oiling, greasing including cost of nuts and bolts what so ever required including any type of fabrication required for the work.
Dismentalling of old & damaged lower bus bar of Dog/Panther conductor, dismentalling of clamps connectors from all concerning equipment
Dismentalling of old & damaged upper of ACSR Dog/Panther Conductor, Dismentalling of Disc Insulator string.
Fabrication of Busbar Gantry.
Erection & Grouting of Busbar Gantry.
Shifting of 11KV S/G New/Damaged Panels/Control relay panel from unloading point to C/R or C/R to loading point.
Erection of New/Old 11KV switchgear panel in control room building in proper alignment, grouting of Anchor bolts matching of switchgear with each other matching of bus bar and related work and its earthing including cost of cement and M.S. Flat.
Shifting of 33KV S/G Panel from unloading to C/R building at place of erection or place of erection to loading point.
Erection of new (Old 33KV) Indoor S/G Panel in control room building in proper alignment, grouting of Anchor Bolts, matching of base channel holes of switchgear and its all related work as grouting of panel and its earthing. It includes cost of cement and M.S. Flat.
Dismentalling of old/damaged existing 33KV S/G Panel including opening of internal connection.
Providing and fixing of flexible copper bond 30mm vide 30cm long and connecting with neutral support structure to T/F neutral bushing and proper tightening
Erection of new lower bus-bar with ACSR Dog/Panther conductor from T/F 33KV Terminal to upper bus-bar connecting with all intermediate equipment and its all related work.
Dismentalling of old/damaged existing 11KV S/G Panel including opening of inter connection.
Making of 33KV M.O.C.B./V.C.B. plinth in size of 1.5x2.4x1.0 meter with brick work cement, sand ratio 1:6 making proper pockets for anchor bolts grouting its plastering around with smooth finish including cost of cement.
Erection of new Upper Busbar with ACSR Dog/Panther Conductor including mounting of disc insulator string.
Shifting of 33KV M.O.C.B./V.C.B./M.C.B. from unloading point to place of erection of 33KV switch yard and dismentalling of its wooden packing of shifting of damaged equipment's as above from plinth to loading point.
Erection and grouting of 33KV MOCB/VCB structure on MOCB/VCB plinth in 1:2:4 ratio with stone ballast.
Dismentalling of 33KV M.O.C.B./VCB from erected structure with the help of crane.
Erection of 33KV M.O.C.B./VCB on erected structure with the help of crane in proper alignment and its all related work.
Making all control cable connection in C.T., M.O.C.B./VCB mechanism, C.T. Junction Box, Transformer Control relay panel D.C. Battery Charger, ACDB Transformer indication board 11KV switchgear including proper termination ferruling and dressing with related work whichever is required.
Erection of 33KV metering cubicle/33KV control Relay Panel in control room in proper alignment including its earthing and related work.
Dismentalling of H.T./L.T. Jumpers from line to each phase.
Taking out 33/11KV XLPE/PILCA cable from drum/complete drum of cable from store its loading carriage and safe unloading by truck/bullock cart at site of work or from site to store.
Digging of suitable pit for making joint of cable for straight through joints and to manage the cable jointer for above joint with complete meggering and all related work and covering the bricks and backfilling. The jointing kit will be provided by Dept. size total 1.5x4 meter and 2 meter deep.
Excavation of old H.T. cable from ground and carrying it upto Kesco Store.
Dismentalling of connected cable box on pole/S/G Panel/Cable support structure.
Mounting of cable box on pole, S/G panel cable support structure with handling of concerning cable and its proper fixing.
Making jumpers from cable box to line, cable support switchgear panels, section poles of each phase.
Painting of Steel Tubular Poles after rubbing, cleaning with emery paper and coating one coat of redoxide on full length of pole and then two coat of Aluminium paint upto X-arm from top including cost of paint and redoxide paint used should be ISI mark Ist class enamel paint.
Making plinth of single pole of 400 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of cement, stone & sand etc.
Grouting of pole with cement brick ballast and coarse sand as per standard specifications.
Digging of cable trench for taking out old/damaged XLPE/PILCA, 3x50 to 3x300sqmm 33/11KV cable & taking out the above Cable from digged trench and back filling of digged trench.
Fabrication of following structure with M.S. Channel, M.S. Angle, M.S. Flat etc. in required size & length including cutting drilling, holes, welding and assembling.
Cable Support Structure
Neutral Support Structure
Fuse Set Unit
Erection and grouting of following structure with 1:4:8 C.C. 25mm brick ballast in required size as proper alignment and making plinth of all structure in 1:2:4 CC mix with 20mm stone grit, 15cm above ground level to smooth finish and proper curing including cost of cement.
Cable Support Structure
Neutral Support Structure
Fuse Set Unit
Unloading of following power T/F main tank filled with oil, along with its all accessories like radiators, conservator tank T/F oil vent pipe etc. from Truck by crane and proper stacking.
10/8/6 MVA, 33/11/6.6 KV T/F
5/3/1.5 MVA, 33/11/6.6 KV T/F
Dismentalling of following power T/F including draining of T/F oil from radiators if necessary dismentalling of all accessories, as Radiators, vent pipe conservator Tank from main Tank of T/F (Either one or all) and its proper stacking.
10/8/6 MVA, 33/11/6.6 KV T/F
5/4/3 MVA, 33/11/6.6 KV T/F
Shifting of T/F Tank Empty/filled by dragging or by crane of following running/damaged T/F from unloading point to plinth of T/F or from T/F plinth to shifting/loading point distance upto 25 meters and its placing in proper alignment on plinth of Transformer.
10/8/6 MVA, 33/11/6.6 KV T/F
5/4 MVA, 33/11/6.6 KV T/F
3/1.5 MVA, 33/11/6.6 KV T/F
Loading carriage & unloading of main tank of T/F alongwith radiators &its all accessories & material of following T/F from store to site of work or worksite to store in between 20 Km. distance.
10/8/6 MVA, 33/11/6.6 KV T/F
5/4/3 MVA, 33/11/6.6 KV T/F
10/8/6 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with no of two cranes and trolla.
Erection of radiators, conservator tank vent pipe and all other accessories on main tank of following T/F including oil filling and all related work.
10/8/6 MVA, 33/11/6.6 KV T/F
5/4/3 MVA, 33/11/6.6 KV T/F
Dismentalling of earthing of running/damaged transformer at two points with the help of gas cutter.
Dismentalling and taking out the cable support structure by cutting with gas cutter for shifting of T/F including cutting of earthing of cable support structure wherever is required including its all related work.
Dismentalling and taking out the neutral support structure by cutting with gas cutter alongwith removing of flexible copper bond and its proper stacking.
Erection and welding of cable support structure with the help of welding including earthing of support in proper alignment and all related work.
Erection & welding of neutral support structure with the help of welding including earthing in proper alignment and all related work and fixing of flexible copper bond.
Earthing of T/F at two points by extending the existing M.S. Flat with main earthmate by welding.
Fabrication of neutral support structure with M.S. Angle and M.S. Flat.
Erection and grouting of neutral support structure with 1 : 4 : 8 CC ratio in proper alignment and plinth 15 Cm. above ground level and smooth finish.
Disconnecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
Connecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
Fabrication of isolator structure as per standard design.
Erection and grouting of Isolator structure in proper alignment and making plinth 15 Cm. above ground level with smooth finish.
Construction of power T/F plinth suitable for 5/10 MVA 33 KV T/F in size of 3 x 3 x 1.5 Mtr. Digging of pit in size of 3.5 x 3.5 x 1.2 Mtr. Of CC work at bottom in size of 3.5 x 3.5 x .15 Mtr. With ratio of 1:4:8 its proper ramming and curing thereafter brick work in size of 3 x 3 x 0.8 Mtr. with 1 : 6 CC Sand ratio, thereafter CC work on top in size of 3 x 3 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing.
T/F Flexible copper bond 30mm vide 30 Cm long & connecting with neutral support to T/F neutral bushing & proper tightening.
Providing of one jeep gang with T.& P on duty on special accessories.
Providing one padel gang with T.& P on duty on special accessories.
Loading carriage & unloading of Rail Pole Pcs. 3 Mtr. long from store to site for power Transformer.
Fitting of 3 Mtr. long Rail Pole on plinth under Power Transformer base.
Dismentalling, erection of Switch yard fencing, civil work such as mounting and dismounting of Piller, Ten set and others
Transportation charges of centrifuging machine to and fro for execution of work.
Transportation charges of T/F oil from store to site.
Erection of Double Pole Structure by digging of Pit.
Providing of copper bus bar for making L for T/F bushing and fabrication & fitting of L connection and related work.
Khan Traders and Electrical Works
Kamadgeri Traders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .