Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-Finance | ₹34.8 L | L1 | Accepted-Finance QUALIFIED |
| 2 | L2₹35.1 LAccepted-Finance | ₹35.1 L | L2 | Accepted-Finance QUALIFIED |
| 3 | L3₹35.2 LAccepted-Finance SHOP NO 48 HOSANNA LAXMI VENKETESWARA LAYOUT 2ND CROSS MARAGONDANAHALLI K R PURAM POST BANGALORE 560036 | BENGALURU URBAN | KARNATAKA | 560036 | ₹35.2 L | L3 | Accepted-Finance QUALIFIED |
| Sl No | Description | Qty | Unit | AATHITHYABUILDERS L1 | AURA ENTERPRISES L3 | Gee Kay Projects L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exc 1.5 m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard / dense soil etc complete all as specified and as directed | 253.1 | Cum | 400 ₹1.0 L | 380 ₹96,178 | 330 ₹83,523 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified and as directed | 147.1 | Cum | 200 ₹29,420 | 108 ₹15,886.80 | 141 ₹20,741.10 |
| 3.00 | Removing excavated soil not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed | 125.5 | Cum | 200 ₹25,100 | 118 ₹14,809 | 204 ₹25,602 |
| 4.00 | M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundations and mass concrete etc complete all as specified and as directed | 14.7 | Cum | 4,200 ₹61,740 | 3,800 ₹55,860 | 4,200 ₹61,740 |
| 5.00 | M&L for Reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Foundation, including rafts, footings, plinth beam etc complete all as specified and as directed | 17.2 | Cum | 6,500 ₹1.1 L | 6,280 ₹1.1 L | 7,800 ₹1.3 L |
| 6.00 | M&L for Reinforced cement concrete M-25 (desing mix) using 20 mm graded stone aggregates as in slab supported on walls, beam and columns in floors, roofs landing balconies canopies etc complete all as specified and as directed | 15.7 | Cum | 6,500 ₹1.0 L | 6,280 ₹98,596 | 7,800 ₹1.2 L |
| 7.00 | M&L for Reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in beam, cantilevers, bressumers, lintels over 1.5 mtr span etc complete all as specified and as directed | 2.9 | Cum | 6,500 ₹18,850 | 6,280 ₹18,212 | 7,800 ₹22,620 |
| 8.00 | M&L for Reinforced cement concrete (M-25) design Mix using 20 mm graded stone aggregates as in column, pillars, piers, posts and struts etc complete all as specified and as directed | 7.6 | Cum | 6,500 ₹49,400 | 6,280 ₹47,728 | 7,800 ₹59,280 |
| 9.00 | Supply only Liquid water proofing compound, ISI marked, all as specified and as directed | 11.3 | Litre | 150 ₹1,695 | 118 ₹1,333.40 | 204 ₹2,305.20 |
| 10.00 | M&L for Pre-cast cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in solid block masonry exc. 10 cm in width and setting in cement mortar (1:6) etc complete all as specified and as directed | 32.5 | Cum | 6,500 ₹2.1 L | 6,800 ₹2.2 L | 6,810 ₹2.2 L |
Updated dates
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
2 Feb 2026, 6:00 pmClosed
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
PROVN OF TOILET BLOCK WITH CONNECTED FITTINGS NEAR MSI COMPLEX AT HQ MEG AND CENTRE UNDER GE (NORTH) BANGALORE
2025_MES_745521_1
86508/E8
Open Tender
Civil Works
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹74,000
5 Jun 2026
20 Dec 2025
9 Feb 2026
20 Dec 2025
2 Feb 2026
13 Jan 2026
20 Dec 2025 - 27 Dec 2025
Excavating in trenches not exc 1.5 m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard / dense soil etc complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified and as directed
Removing excavated soil not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed
M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundations and mass concrete etc complete all as specified and as directed
M&L for Reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Foundation, including rafts, footings, plinth beam etc complete all as specified and as directed
M&L for Reinforced cement concrete M-25 (desing mix) using 20 mm graded stone aggregates as in slab supported on walls, beam and columns in floors, roofs landing balconies canopies etc complete all as specified and as directed
M&L for Reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in beam, cantilevers, bressumers, lintels over 1.5 mtr span etc complete all as specified and as directed
M&L for Reinforced cement concrete (M-25) design Mix using 20 mm graded stone aggregates as in column, pillars, piers, posts and struts etc complete all as specified and as directed
Supply only Liquid water proofing compound, ISI marked, all as specified and as directed
M&L for Pre-cast cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in solid block masonry exc. 10 cm in width and setting in cement mortar (1:6) etc complete all as specified and as directed
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions with fair finished square or rectangular flat surfaces of concrete complete all as specified and as directed
M&L for Formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with fair finished flat surfaces of concrete etc complete all as specified and as directed
M&L for formwork to sides and soffits of floor or roof beam, beam and haunching, girders, bressummers, lintels cantilevers, shelves including supports, overhangs etc also splays between floor and beam with fair finished flat surfaces etc complete all as specified and as directed
S&F Factory made pressed steel frame of profile size 125 X 60 mm for door with one ore more rebate, made of 1.25 mm thick M S sheet includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
M&L for cement concrete 1:3:6 type C-0 using 12.5mm graded stone aggregate as in hold fast and filling of pressed steel chowkat etc complete all as specified and as directed
S&F Flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed
M&L for Preparation of new wood or wood based surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face etc with wood free EPS complete all as specified and as directed
S & F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F GI tubing medium grade 20 mm bore with all fitting laid in trenches/walls/Roads for cable protection complete all as specified and as directed
S&F Gun metal Gate valve with iron wheel head, screwed both ends for iron pipe 50mm dia and fixed all as specified and as directed
S&F Sheet glass 4mm thick of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares not exc 0.50 sqm in each pane complete all as specified and as directed
S&F Figured glass 4mm thick, pin head type and glazing with oil putty in squares in not exc 0.5 sq.m in each pane etc omplete all as specified and as directed
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
All as per item No 31 herein before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and as directed
M&L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in 75 mm thick sub base to flooing etc complete all as specified and as directed
M & L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick backing coat in cement mortar (1:3) complete all as specified and as directed
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed (NOTE : Sheet glass/figured glass and wire mesh will be measured and paid separately).
M&L for rendering 5 mm thick cement mortar (1:3) on fair faces of brick work or concrete ceiling surface finished even and smooth without using extra cement etc complete all as specified and as directed
M&L for Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe -E-165 etc complete all as specified and as directed
M&L for rendering 10 mm thick cement mortar (1:6) on fair faces of brick work or concrete surface finished and smooth without using extra cement etc complete all as specified and as directed
M&L for preparing newly plastered surface of ceiling and applying three coat of white wash etc complete all as specified and as directed
M&L for Preparing new plastered suface of walls and applying two coats Distemper acrylic emulsion, white or tinted over a coat of self primer etc complete all as specified and as directed
M&L for preparation of new plastered wall surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
M&L for Glazed ceramic coloured tiles 300X450X7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over & including backing coat 10 mm thick cement mortar (1:3) complete all as specified and as directed
M & L for water proofing treatmennt over RCC roof slab all as per following specification complete all as specified and directed :- (i) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Applying compatible primer/bonding bitumen @ 0.40 Litre/Sq m (iii) Applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions (iv
S&F PVC (SWR) vent cowls of 75 mm dia complete all as specified and directed
M&L for Hard core with broken stone or boulder of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15 cm thick water and rammed to a true surfac etc all as specified and as directed
Filling soil under floors Spreading and levelling in well layers not exc 25 cm thick including watering, ramming as required etc complete all as specified and as directed
M&L for PCC 1:3:6, type C-1, using 20 mm graded aggregates as in 75 mm thick plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade "A" complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard / dense soil etc complete all as specified and as directed
M &L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc complete all as specified and as directed
Excavating in trenches not exc 1.5 m wide and exc 1.5m but not exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard / dense soil etc complete all as specified and as directed
M&L Pre-cast Cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregates as in solid block masonary exc 10 cm in width and setting in CM (1:4) all as specified and directed.
M&L for PCC (1:2:4) type B-0 using 12.50 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregates as in copings, Chajja kerbs, roof padding/staging of water tank etc including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L for Rendering 10 mm thick Cement mortar (1:4) on fair faces of brick / concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for Screed bed/rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction, finishing even & smooth without using extra cement etc complete all as specified and as directed (Notes : WPC shall be measured and paid seperately)
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipe 200 mm dia bore after they are laid & tested complete all as specified and directed.
M & L for Point Wiring with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories including GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :-
One light point controlled by one switch
One fan/exhaust point controlled by one switch/regulator
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 3.5 core laid in trenches/wall all as specified and as directed
S&F LED batten with luminaire suitable for indoor applications 18/20 Watts capacity, 4 feet long with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed.
S&F LED batten with luminaire suitable for indoor applications 10 Watts capacity, 2 feet long with polycarbonate housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed.
Supply and fix Modular switch 1 way 6A,1 module all as specified and directed.
Supply and fix Modular Socket, 6Amps - 2/3 pin combined 2 module all as specified and directed.
S&F MCB TPN 240 volts 32 Amps C curves complete all as specified and as directed
S&F MCB single pole 240 volts 6 to 32 Amps, C curves complete all as specified and as directed
Supply and fix Modular Fan step regulator, 120W - 2 module all as specified and directed.
S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F MCB Distribution board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar as specified and as directed.
M&L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 100mm centre to centre both ways, funnel with watering pipe wire mesh and lugs
, test point complete all as specified and as directed.
S&F LED bldg security light fitting 30Watts capacity with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection complete all as specified and as directed. (Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes specified in P S herein after)
S&F Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
S&F Exhaust Fan 225mm Sweep , steel body AC single phase, 230Volts with blade and frame and louver all as specified & directed.
M&L for sand cushioning with a layer of river sand under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed
Supply & laying sub class burnt "B" bricks for cable protection, all as per Para 19.75 of SSR Part-I complete all as specified as directed
One 3 pin socket out let 5 Amps on independent board Note for Item No 98 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board in the item rate quoted.
S&F GI tubing medium grade 25 mm bore with all fitting laid in trenches/walls/Roads for cable protection complete all as specified and as directed
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
tender86508.pdf
Tender Documents • 1.35 MB
BOQ_834790.xls
BOQ • 2.92 MB
Download all tender documents and submit your bid