Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance MADINA CHOWK MAISUMA GOW KADAL SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Finance |
Tender Value
₹52.9 L
EMD Value
₹1.1 L
Closing Date
27 Aug 2022, 4:00 pmClosed
Executive Engineer, ED-3rd srinagar
Office of Executive Engineer, ED-3rd srinagar
Replacement of Bare LT Conductor by LT AB Cable (120 sqmm) of 04 No 250 KVA DTs under Capex Budget 2022-23 (PDDSS2022100149) for areas falling within the jurisdiction of ED-3rd, (Partial Turnkey Basis- Cable to be provided departmentally)
2022_PDD_181230_1
ED-III/10 of 2022-23, Dated - 27/07/2022
Open Tender
Electrical Works
Turn-key
45 days
Office of Executive Engineer, ED-3rd srinagar
Refer SBD, Technical Specifications, Drawings
6 documents required · 6 mandatory
₹2,000
Executive Engineer, ED-3rd srinagar
₹1.1 L
2 Sept 2022
27 Jul 2022
29 Aug 2022
27 Jul 2022
27 Aug 2022
1 Aug 2022
28 Jul 2022 - 27 Aug 2022
Amount
Replacement of Bare LT Conductor by LT AB Cable (3X120+1x16+1X70) of 04 No 250 KVA DTs under Capex Budget 2022-23 (PDDSS2022100149) for areas falling within the jurisdiction of ED-3rd, (Partial Turnkey Basis- Cable to be provided departmentally)
Supply, Installation, Testing and commissioning of S.T. poles 8.0 Meter long swaged Type conforming to ST 410 SP-15, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded. 1. ZK DT 185 - 03 no. 2. ZK DT 244 - 0 3. WK DT 99 - 04 no. 4. Wk DT 102 - 02 no.
Supply, installation, testing and commissioning of Suspension/Tension Clamp (Anchor clamp / dead end clamp) suitable for LT ABC of 70 sq.mm. Bare messenger with eye hook 1. ZK DT 185 - 95 no. 2. ZK DT 244 - 91 no. 3. WK DT 99 - 25 no. 4. Wk DT 102 - 30 no.
Supply and Fixing of GI Pole Support Clamp including GI Nut and Bolts with washers for 11 Mtr Pole with size - 50x8x376 mm 9 mtr pole with size - 50x8x376 mm 8 mtr with size 50x 8x 332 mm 8 mtr or 9 mtr PCC with size 50x8x441mm 1. ZK DT 185 - 95 no. 2. ZK DT 244 - 91 no. 3. WK DT 99 - 25 no. 4. Wk DT 102 - 30 no.
Supply and Fixing of Cable tie (each packet contains 100 Nos.) 1. ZK DT 185 - 02 no. 2. ZK DT 244 -02 no. 3. WK DT 99 - 02 no. 4. Wk DT 102 - 02 no.
Supply and Fixing of Cable end caps 1. ZK DT 185 - 36 no. 2. ZK DT 244 - 34 no. 3. WK DT 99 - 10 no. 4. Wk DT 102 - 12 no.
Supply, Laying, Testing and Commissioning of 4 core 35 mm2 PVC Cable from AB Cable taping point through Piericing connector to PMDB (Pole Mounted Distribution Board) including Clamps/thimbles. 1. ZK DT 185 - 165 Mtr 2. ZK DT 244 - 123 Mtr 3. WK DT 99 - 180 Mtr 4. Wk DT 102 - 220 Mtr
Supply, installation, testing and Commissioning of Piercing Connector for street light connections (main line 70-120 sqmm/branch line section 4-25 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messenger 1. ZK DT 185 - 78 no. 2. ZK DT 244 - 75 No. 3. WK DT 99 - 22 No. 4. Wk DT 102 - 25 No.
Supply, installation, testing and Commissioning of Piercing Connector for DB connection from main ABC to DB (main line 70-120 sqmm/branch line section 4-25 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messenger 1. ZK DT 185 - 220 no. 2. ZK DT 244 - 164 No. 3. WK DT 99 - 120 No. 4. Wk DT 102 - 164 No.
Supply, installation, testing and Commissioning of Piercing connector for ABC to ABC Tee connection (main line 70-120 sqmm/branch line section 70-120 sqmm) insulated and insulated branching and bare and insulated branching in case of neutral messenger 1. ZK DT 185 - 15 no. 2. ZK DT 244 - 11 No. 3. WK DT 99 - 04 No. 4. Wk DT 102 - 12 No.
Supply, installation, testing and Commissioning of 3 Phase SMDB (Service Main Distribution Box) IP54 made from 20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line and for giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts. The job also includes disconnection/reconnection of consumer energy meter including providing of aluminium lugs, if required. 1. ZK DT 185 - 55 no. 2. ZK DT 244 - 41 No. 3. WK DT 99 - 30 No. 4. Wk DT 102 - 41 No.
Supply, installation, testing and Commissioning of LT Distribution Box for 250 kVA DTR with MCCB for incomer & Outgoing Circuits, Distribution Boxes made out of CRCA MS for controlling the L.T. feeders from the L.T. side of Distribution Transformers IS: 8623 (amended upto date) for enclosure Box & for degree of protection provided by enclosures of electrical equipments. The Aluminum Busbar for Phase & Neutral should be of size 25x8 mm and with Heat Shrinkable bus bar insulation tubing of Red Yellow-Blue & Black mounted on epoxy resin cast bus insulators fixed on suitable fixing arrangement with adequate clearance. The DB should have Bottom entery of Cable with proper Glands/grommets-Safety Screws Incomer 01 no. MCCB- 400 A Outgoing 03 no. MCCB - 200 A O/G Link Disconnector 09 no. - 200 A 1. ZK DT 185 - 02 no. 2. ZK DT 244 - 02 No.
Supply, installation, testing and Commissioning of LT Distribution Box for 250 kVA DTR with MCCB for incomer & Outgoing Circuits, Distribution Boxes made out of CRCA MS for controlling the L.T. feeders from the L.T. side of Distribution Transformers IS: 8623 (amended upto date) for enclosure Box & for degree of protection provided by enclosures of electrical equipments. The Aluminum Busbar for Phase & Neutral should be of size 25x8 mm and with Heat Shrinkable bus bar insulation tubing of Red Yellow-Blue & Black mounted on epoxy resin cast bus insulators fixed on suitable fixing arrangement with adequate clearance. The DB should have Bottom entery of Cable with proper Glands/grommets-Safety Screws Incomer 01 no. MCCB- 400 A Outgoing 02 no. MCCB - 200 A O/G Link Disconnector 06 no. - 200 A 1. WK DT 99 - 02 No. 2. Wk DT 102 - 02 No.
Supply, installation, testing and commissioning of 300mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type including Thimbles/Lugs/Clamps. 1. ZK DT 185 - 80 Mtr 2. ZK DT 244 - 80 Mtr 3. WK DT 99 - 80 Mtr 4. Wk DT 102 - 80 Mtr
Supply and fixing of GI Channel/Angle/Flat of sizes including clamps including GI nuts and bolts 1. ZK DT 185 -100 Kg 2. ZK DT 244 - 100 Kg 3. WK DT 99 - 120 Kg 4. Wk DT 102 - 120 Kg
Supply, installation, testing and commissioning of 70 mm² XLPE LT Cable Single Core, un-armoured, FRLS from Transformer LT DB neutral to Messenger Wire including PG Clamps including Thimbles/Lugs/Clamps. 1. ZK DT 185 - 10 Mtr 2. ZK DT 244 - 10 Mtr 3. WK DT 99 - 15 Mtr 4. Wk DT 102 - 10 Mtr
Supply, installation, testing and commissioning of 16 mm² Cable (2C) from LT DB box to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Thimbles/Lugs/Clamps. 1. ZK DT 185 - 635 Mtr 2. ZK DT 244 - 445 Mtr 3. WK DT 99 - 185 Mtr 4. Wk DT 102 - 250 Mtr
Providing of material and laying of Pole Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm 1. ZK DT 185 - 03 no. 2. ZK DT 244 - 0 3. WK DT 99 - 04 no. 4. Wk DT 102 - 02 no.
Supply and fixing of Pre insulated straight through joints suitable for 1(3X120+1x16(street light)+1X70(insulated/non-Insulated messenger) Cable 1. ZK DT 185 - 08 Set. 2. ZK DT 244 - 08 Set. 3. WK DT 99 - 06 Set. 4. Wk DT 102 - 06 Set.
Supply and Painting of poles with one coat of Red oxide Primer and two coats of Aluminium Paint 1. ZK DT 185 - 03 no. 2. ZK DT 244 - 0 3. WK DT 99 - 04 no. 4. Wk DT 102 - 02 no.
Providing and fixing of Insulation tape (red / yellow / black) 1. ZK DT 185 - 10 no. 2. ZK DT 244 - 10 no 3. WK DT 99 - 10 no. 4. Wk DT 102 - 10 no
Providing of material & Laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole 1. ZK DT 185 - 18 no. 2. ZK DT 244 - 12 no 3. WK DT 99 - 10 no. 4. Wk DT 102 - 06 no
Providing and Fixing of Misc Items such binding wire, screws, Thimbles of sizes, Clamps of sizes etc. 1. ZK DT 185 - 2 no. 2. ZK DT 244 - 2 no 3. WK DT 99 - 2 no. 4. Wk DT 102 - 2 no
Providing and fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 1. ZK DT 185 - 3 no. 2. ZK DT 244 - 6 no 3. WK DT 99 - 3 no. 4. Wk DT 102 - 3 no
Straightening of 9/8 Mtr ST Poles by way of opening the pits 1. ZK DT 185 - 15 no. 2. ZK DT 244 - 12 no 3. WK DT 99 - 6 no. 4. Wk DT 102 - 4 no
Dismantling of ACSR Conductor and LT Shackle Insulators along with U Clamps including Transportation including Carriage/Loading/unloading from site to Divisional Stores Bemina Ed-3rd 1. ZK DT 185 - 1500 Mtr 2. ZK DT 244 - 1200 Mtr 3. WK DT 99 - 1800 Mtr 4. Wk DT 102 - 1500 Mtr
Installation, testing and commissioning of 120 mm² AB Cable (3X120+1x16 (street light) +1X70( messenger)) XLPE (1.1kV, 3+1 C, Al) including loading from Divisional Stores at Bemina Ed-3rd, carriage and unloading at different sites (Cable to be Provided by the Department) 1. ZK DT 185 - 3.5 Km 2. ZK DT 244 - 2.5 Km 3. WK DT 99 - 1.5 Km 4. Wk DT 102 - 1.8 Km
M/S TOP TECH ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .