₹27,178
Closing Date
2 Mar 2026, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
SITC of Air Conditioning Machines at proposed I and CA Department at Block - II, 2nd Floor, Writers Buildings.
2026_WBPWD_1003834_1
WBPWD/EEKED/eNIQ-34Q3rd/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Writers Buildings
Please refer Tender documents.
5 documents required · 5 mandatory
₹27,178
O/o The Executive Engineer, Kolkata Electrical Div
5 Mar 2026
11 Feb 2026
5 Mar 2026
11 Feb 2026
2 Mar 2026
21 Feb 2026
20 Feb 2026
Supply & Delivery of commercial Grade conceal Non inverter Split Air conditioner (IDU&ODU) with fully metal enclose IDU having following specification: Minimum Cooling Capacity: 6900W IS Compliance- IS 1391 Refrigerant- R410A/R32 Compressor - Rotary/scroll Evaporator & Condenser Coil: Copper (LCD (wireless / wired Remote) and All other accessories Operating outdoor Temperature - 50°C and above Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard. Make:- Daikin / Hitachi / Voltas / Bluestar
Supply & Delivery of commercial Grade conceal Non inverter Split Air conditioner (IDU&ODU) with fully metal enclose IDU having following specification: Minimum Cooling Capacity (W) - 5000W IS Compliance- IS 1391 Refrigerant- R410A/R32 Compressor - Rotary/scroll Evaporator & Condenser Coil: Copper (LCD wireless / Wire Remote) and All other accessories Operating outdoor Temperature - 50°C and above Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard. Make:- Daikin / Hitachi / Voltas / Bluestar
Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC
SITC of commercial Grade conceal inverter Split Air conditioner (IDU&ODU)with fully metal enclose IDU having following specification [all necessary accessories for hanging indoor & outdoor unit as per site condition & As per Direction of EIC]: Minimum Cooling Capacity: 14000W IS Compliance- IS 1391 Refrigerant- R410A/R407C/R32 Compressor - Rotary/ Scroll Evaporator & Condenser Coil: Copper CFM/Tr - 400 LCD wirless / wired Remote and All other accessories operating outdoor Temperature - 45°C and above Power supply - 415 V 3-Ph,50Hz (+ Tolerrance as per applicable standard) Safety Features: Overheating protection for compressor, LP HP cut out, single phase prevension Make:- (Daikin / Mitshubishi Heavy / Voltas/Hitachi )
REFRIGERANT PIPING WITH INSULATION Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410A/R407C refrigerant & 19 mm thick Nitrile Rubber 'class O' Insulation tube with supports & brackets as per direction of EIC.
Liquid Line (3/8" dia) without rubber insulation (make: Rajco / Mandev / Royku)
Suction Line (5/8" dia) with 19 mm thick nitrile rubber insulation Al foil covered (make: Rajco / Mandev / Royku)
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 3 core x 2.5 mm² (Make- RR Kable / Finloex / Polycab).
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 4 core x 2.5 mm² (Make- RR Kable / Finloex / Polycab).
S & Installation of Extra Add-on Items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC.
Supply & Laying 1.1KV grade 3 core 4 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC)
DRAIN PIPE Supply and fixing of Drain piping by UPVC with 6mm thick nitrile rubber insulation and necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc:
Supply & Laying 20 mm hard PVC pipe (heavy type) for water discharge
Supplying, fabrication & fixing M.S. Angle Frame for installation of 8 nos Outdoor unit . the structure having 50 x 50 x5 mm MS angle for main bottom support grouted on wall and in between main support 25 x 5 mm ms strip . For railing vertical & horizontal support is made by 25 x 25 x 5 mm Angle for safety of maintenance; including cutting holes , welding , painting and mending good damage as per EIC
Supply & Fixing Powder coated Linear type extruded aluminium Square Grill (Make: premire/systemair/Air enterprise / Airmaster) without VCD
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. - With out angle iron support 150x50x1.25mm (18SWG)
S/F 3 mm thick ACP Board for covering the IDU complete with linkages, levers, fittings, angle iron supports, trap door incl. all accessories as per direction of EIC (Make : Aludecor / Pratap)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.77 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
BOQ_2461048.xls
BOQ • 0.33 MB
2911.pdf
Tender Documents • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .