Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAccepted-AOC | ₹6.1 Cr | L1 | Accepted-AOC L1 being lowest bidder |
| 2 | L2₹6.2 Cr+₹16.6 L (2.73%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹6.2 Cr+₹16.6 L (2.73%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹6.5 Cr+₹37.1 L (6.09%)Rejected-Finance | ₹6.5 Cr+₹37.1 L (6.09%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹6.6 Cr+₹51.5 L (8.47%)Rejected-Finance | ₹6.6 Cr+₹51.5 L (8.47%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹6.6 Cr+₹53.0 L (8.72%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹6.6 Cr+₹53.0 L (8.72%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹6.3 Cr
EMD Value
₹12.6 L
Closing Date
28 Jun 2025, 6:00 pmClosed
HQ CHIEF ENGINEER PATHANKOT ZONE
HQ CHIEF ENGINEER PATHANKOT ZONE
ADDN ALTN AND SPECIAL REPAIR TO CERTAIN JCOs OR MD ACCN AND FAFA ACCN AT PEERU MEHTA VIHAR TAWI COMPLEX AND RAIPUR SATWARI AT JAMMU
2025_MES_700474_2
CEPZ-22/2024-25
Open Tender
Civil Works
Item Rate
548 days
GE SATWARI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE SATWARI
₹12.6 L
Yes
1 Aug 2025
3 Jun 2025
5 Jul 2025
3 Jun 2025
28 Jun 2025
14 Jun 2025
Amount
Taking down chowkats or frames with shutter (without taking off shutter from the frame) not exceeding 1.5 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing rubish material from site ; complete all as specified and directed by the Engineer in Charge.
Taking down chowkats or frames with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm & not exceeding 4 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing rubish material from site ; complete all as specified and directed by the Engineer in Charge.
Material & Labour Factory Made Box type steel windows , double shutter (up to 4 storey), outer frame made out of ERW tube 'P' section (60mm x 45mm x 25mm) mullion of ERW tube 'P' section 60mm x 30mm x 25mm and shutters of ERW tube 'P' section (50mm x 35mm x 20mm) section of frame mullion and shutter shall be 16 gauge openable shutters side hung including pintol hinges with two nos of MS tower bolts 150mm size on each shutter steel handle and stopper of 'Z' section as specified complete with sash bars dovetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings/opening for cooler/AC where required steel windows will be double shutter external glazed and internal wire gauze complete all as specified and as per drg No CEPZ/C-TD-27/13, sheet 1/4 to 4/4 ; complete all as specified and directed by Engineer -in-Charge. Note:- The quoted rate against this item shall also includes :- (a) For provn of one shop coat of zinc chromate primer on all exposed steel surfaces and one coat of coal tar on the ends of steel frame in contact with brick/concrete surfaces. (b) 04 Nos MS steel lugs of 20mm x 5mm MS flat 200mm long over all welded to frames. (c) PCC blocks in PCC (1:2:4) type B1 for embedding lugs. (d) MS grill 10mm square bar spacing 100mm centre to centre. (e) Window should be paneled with 4mm thick plain float glass for windows and frosted glass for ventilator. (f) Windows shall Stainless Steel wire mesh size 0.36 mm nominal dia of wire and average width of aperature 1.40mm for wire mesh shutter.
Supply and fixing for pressed steel frames of size 105mm x 60mm made out of 1.25mm thick MS sheet for doors single rebated with & including mild steel 04 nos hinges (02 x at top, 01x midldle & 01x bottom) medium weight 100 mm long and 25mm x 3mm flat iron in 06 x holdfast, tie bar including necessary fixing lugs, hold fast, lock strike plate and fixing arrangement etc with & including priming one shop coat of zinc chromate primer on all exposed steel surfaces and making good the disturbed surfaces in cement mortar 1:3 or cement concrete 1:2:4 type B-1 ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for pressed steel frames of size 125mm x 60mm made out of 1.25mm thick MS sheet for doors single rebated with & including mild steel 08 nos hinges (04 x at top, 2 x midldle & 02 x bottom) medium weight 100 mm long and 25mm x 3mm flat iron in 06 x holdfast, tie bar including necessary fixing lugs, hold fast, lock strike plate and fixing arrangement etc with & including priming one shop coat of zinc chromate primer on all exposed steel surfaces and making good the disturbed surfaces in cement mortar 1:3 or cement concrete 1:2:4 type B-1 ; complete all as specified and directed by the Engineer in Charge. ; complete all as specified and directed by the Engineer in Charge.
Material and labour for cement concrete 1:3:6 type C-0 using 12.5 mm graded crushed stone aggregate as in back fill of pressed steel door frames including necessary form work ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for Pressed steel cup board frame of MS sheet 1.25 mm thick size of frame 60mm x 40 mm with rebate of 20 mm wide and 12 mm deep with & including PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregates as in filling to back of Pressed steel cup board frame chowkhats including necessary butt hinges 100mm size ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for Solid PVC Door Frame of size 50mm x 47mm made out of made out of 5mm wood grain printed PVC sheet and edges will painted to match with printed sheet, reinforced with M.S. Square tube,fixing in opening as per specifications and drawing including and making good the disturbed surfaces of walls in cement mortar 1:3 or cement concrete 1:2:4 type B-1 ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for stainless steel grade SS-304 works factory made Box type hollow section 0.80 mm thick, size for vertical and top rail 100mm x 35mm, size of middle rail 150mm x 35mm and bottom rail of size 200mm x 35mm single rebated comprises wire gauged skelton shutter including 2 Nos 150mm stainless steel handles, 200mm stainless steel tower bolts( 02 Nos) and 01 No 300mm long stainless steel sliding door bolts ; complete all as specified and directed by the Engineer-in-Charge. Note :- Wire gauged to be measured and paid Separately.
Supply and fixing for 30mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for 30mm thick second Class hard wood glazed & gauzed shutter with sash bar in square/rectangle and skelton shutters open rebated and prepare to receive glass, gauge etc but divided into squares with plain chamfered or rounded mitred and rebated sash bars,stiles and rails as specified in SSR 2009 Part-I Sec 8 clause 8.24(a) ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet polyurethne painted on the front face & 2mm plain colour PVC sheet on back face, in frame at site ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for Factory Made WPC (Wood Plastic Composite) single extruded 100% lead free ROHS certified board of 18mm thick pre laminated shutter for kitchen cabinet and cupboards. The laminated shutter should be pre laminated side with different design and other side plain white , fixed with screws to timber frame work including 2mm thick PVC edge banding of same colour of MDF board fixing with nails/rasin around the shutter. The 18mm board should be 100% lead free, water proof, termite proof and borer proof and should have woods screw holding capacity ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for Factory Made 5mm thick PVC Sheet of density 600Kg/cbm manufacured by an ISO 900-2008 certified company as in paneling for back side (wall side) and also manufacurer's test report and test certificate is mandotary with each and every supply of the material complete as per manufacturer's specifications ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for framed work as in doors or gates and water tank stage,Cooler Stand, balcony railing and similar work etc with angle or other section, tubular pipe (circular/ ractangular) with flat and square guard bar, rails, braces, etc.complete, drilled for fixing of steel sheeting or other covering, Doors etc, to be prepared for hanging or sliding including necessary cutting in bricks/concrete wall and fixed with hooks and hinges or steel hanging door fittings and fastening and fixing FE 290 Gde E-165 ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for stainless steel grade (SS-304) works of flat iron, square bar, round bars etc. as in framed work such as grills, guard bars, gratings etc including bending, cutting and welding as necessary ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for 1.25 mm thick Mild steel, plain black sheet in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc as required complete including cutting out of existing sheet if required ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for butt hinges of stainless steel medium weight of size 100mm ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for Aluminium handles, fabricated type, anodised of Size 125mm, anodised section and fixed ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for Aluminium anodised, barrel tower bolts size 150mm of extruded section and fixed ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for Aluminium alloy, anodised, sliding door bolt of Size 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing in repairs Stainless Steel helical ordinary rat tail rod pattern spring 150mm including roller and roller plate complete including fixing to pressed steel frames necessary welding work including taking down the old unserviceable door spring ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for aluminium hanging floor door stopper,Twin rubber stopper,size 100mm , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing in repairs 25mm outer dia Stainless steel chromium plated decorative drapery rod of thickness 20 gauge and for every 01 RM length, with stainless steel brackets near to ends with Stainless Steel designed finials (Design approved by GE) for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows ( including necessary fittings) & including taking down the old unserviceable rod ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for continuous (piano) hinges Width of flaps (when open) 30mm , heavy duty mild steel, bright finish or electro galvanised suitable for 19mm thick shutter and fixed ;complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for hasp & staple safety type Stainless Steel with stainless steel hinges pin including bolt to hinges plate fixed with screws of 75 mm in length ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing for 50mm magnetic catches with brass body and striking plate including letting in as fixed ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for 100mm long Stainless Steel handles of glossy finish with stainless steel screws ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for roughening surfaces of old concrete floor or old plastered skirting by picking, sweeping clean and washing down with water to remove dust etc and brushing surface with neat cement slurry with 3.0 kg of cement per square metre, removing serviceable material to store and rubbish off the premises & removal of rubbish material out of MoD land ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazzo dado from wall surface (but not backing), removing serviceable tiles to store , rubbish off the premises & removal of rubbish material out of MoD land ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Ceramic edge cut joint free coloured or printed light shade tiles 8 to 10mm thick (square/ rectangular) polished area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match , over & including 15mm thick screed bed in Cement mortar (1:6) ; complete all as specified and directed by the Engineer in Charge.
Material and labour for Ceramic edge cut joint free coloured or printed light shade tiles 08 to 10 mm thick (square/ rectangular) polished area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , as in vertical surfaces dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match , over & including 10mm thick screed backing in Cement mortar (1:4) ; complete all as specified and directed by the Engineer in Charge.
Material and labour for Non Skid Digital Ceramic joint less coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match the surface , with & including over 15mm thick screed bed in Cement mortar (1:6) ; complete all as specified and directed by the Engineer in Charge.
Material and labour for Glazed Ceramic Coloured Digital tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over & including 10mm thick screed backing in Cement mortar (1:4) ; complete all as specified and directed by the Engineer in Charge.
Material and labour 18 to 20 mm thick, pre-polished kota stone in step, jambs, window cills in one piece and other of size not less than 580 mm x 580mm slab flooring , over and including 20mm thick screed bed in CM 1:6 ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour 18 to 20 mm thick, pre-polished kota stone in riser, wall cladding,pillars in one piece and other of size not less than 580 mm x 580mm slab flooring over and including 15mm thick screed bed in Cement mortar (1:4) ; complete all as specified and directed by the Engineer in Charge.
Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling etc; exposing the reinforcement without disturbing, the reinforcement free from rust by sand blasting/using chemical and Material & Labour for apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places additional reinforcement welding with existing reinforcement as directed wherever required binding RCC 50mm x 50mm (10 mm gauge welded mesh ) & tack , securing with clips / blinding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to four storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster with chicken wire mesh in cement mortar 1:4 with water proofing compound @ 3% by weight of cement and recron 3 S as per manufacturer instruction cleaning & removing of waste meterial etc and apply two coats of Dr fixit / Pidilite / Sika / Fosroc new coat ezee at interval of 8 hours cure for the surfaces ; complete all as specified and directed by the Engineer in Charge.
Demolition of reinforced cement concrete of any discription and any position( ground to 4th floors) and removing the rubbish from the work site out side defence premises ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Reinforced cement concrete M-20 (Nominal Mix) type B1 ( using 20 mm graded crushed stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.(Column footing , Column and PB) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for flat rough finished surfaces of concrete ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for use and waste form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roof and not exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n.exc. 20cm wide for rough finished surfaces of concrete ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platform (01x hole drilled for gas pipe in each kitchen platform) and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15mm thick screed bed in Cement mortar (1:4) ; complete all as specified and directed by the Engineer in Charge.
Material and labour for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing the surfaces with sand paper to make surfaces even and smooth ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for applying two coats of synthetic enamel paint on new wooden surfaces of any description over a coat of pink primer having width/girth exceeding 10 cm complete including preparation of surfaces necessary filling with putty as and where required to make and rubbing the surfaces with sand paper to make surfaces even and smooth ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling & Complete removal of existing roof treatment of any description viz ; tar felt or membrane surface or roof tiles under layer, taking down of cement plaster, PCC, brick tiles and mud phuska of any thickness etc. including grubbing up of tree roots, grass roots and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc ; with & including filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying PCC padding on roof with and including removing all the debris to a distance as directed by the Engineer-in-Charge.
Material and labour for Plain cement concrete 1:2:4 type B-0 using 12.5 mm graded Crushed stone aggregate as in roof paddding, surfaces finished even and fair without using extra cement to receive cement plaster ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Rendering 15mm thck in Cement Mortar (1:4) on new Concrete surfaces of roof padding and including mixing of water proofing compound (WPC shall be measured and paid separately) , surfaces finished even and smooth without using extra cement to receive treatment on roof Complete ; complete all as specified and directed by the Engineer-in-Charge
Material & labour for Water Proofing Treatment to roof surfaces (in Four Coats) With fiber reinforced elastometic liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius to RCC roof slab, Roof reatment shall be carried out in four coats to newly plastered roof surfaces as per the procedure given below :- (a) Apply First Coat of fiber reinforced elastometic liquid water proofing membrane as described above with 33% dilution as priming coat as directed by Engineer-in-Charge and allow it to dry brfore next coating. (b) Laying Second Coat of fiber mesh 0.3mm thickness weave in leno pattern having weight 45 Grams Per Sqm and pasting it properly with overlap of 50mm as directed by Engineer-in-Charge and allow it to dry brfore next coating. (c) Apply Third Coat of fiber reinforced elastometic liquid water proofing membrane as described in para (a) above but undiluted @ 0.45 Litres Per Sqm of roof surfaces as directed by Engineer-in-Charge and allow it to dry brfore next coating. (d) Applying Fourth & Final Coat of fiber reinforced elastometic liquid water proofing membrane as described in para (a) above but undiluted @ 0.45 Litres Per Sqm of roof surfaces as directed by Engineer-in-Charge. (e) The water proofing treatment shall be carried out by the authorised applicator of manufacturer, Contractor shall submit a triparty agreement (between contractor, said manufacturers of Fiber Reinforced Elastomeric Liquid Water Proofing Membrance and their Authorised Applicator) on Non Judicial Stamp Paper to GE and shall be approved by the GE before commencement of roof treatment work at site(Refer Schedule "A" notes).
Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical surfaces(not exceeding 45cm depth of sunken) complete specified as under and as directed by the Engineer-in-charge :- (a) Cleaning the surfaces with wire brush/coir brush, removing loose material like dust particles,dirt etc and after that laying 75mm thick PCC 1:2:4 (using 20mm graded crushed stone aggregate) for maintain the outward slope. (b) Rendering 15mm thick in cement mortar(1:3) using coarse sand including mixing of liquid WPC in mortar @200ml per bag of cement of 50kg, trowel even and smooth with steel trowel on sunken surfaces. (c) Creating fillet covering of 50x50mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on horizontal and vertical surfaces. (e) Provision of glass fiber mesh of 2x2mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72hrs of above coating (g) Joining the sanitary pipes with the waterproofing tape having bridging ability of more then 1.5mm (h) Filling the gap between the wall opening and sanitary pipe with non shrink cementeous grout. Note: (i) The complete waterproofing treatment shall be carried out by the manufacturer or their authorized applicators as approved by the GE.(ii) The plan area of floor shall be considered for measurments & payment.
Material and labour for PCC 1:5:10 type E2 using brick aggregate as in mass filling surfaces finished even & fair without using extra cement ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 40mm dia Galvanised Iron tubing Medium grade laid under floors as a spout pipe in sunken floors ; complete all as specified and directed by the Engineer-in-Charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing unserviceable material from the work site ouside defence premises ; complete all as specified and directed by the Engineer-in-Charge.
Supply only Liquid water proofing admixture ; complete all as specified and as directed of as per manufacturers instruction.
Disconnecting , dismantling and taking down the old unservicable existing water storage tank and removing to store of capacity exc 250 ltrs but n exc 500 ltrs ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for Rotational moulded polyethylene water storage tanks of 500 litres capacity,(cylindrical vertical with closed top) white in colour, hoisted and fixed in position all as specified in SSR 2009 Part-I (as per IS 12701-1996) with & including Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed for 20mm bore pipe (Minimum weight 20mm-210gms) , including making connections, connecting up pipes, securing access covers etc ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Gun metal, globe or gate valves of 20mm , with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of 20mm ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 75 mm thick PCC 1:2:4 type -B-2 (using 40 mm graded crushed stone aggregate) as in floors surfaces finished even & smooth without using extra cement ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour 25mm thick PCC 1:2:4 type B1 using (20mm graded crushed stone aggregate) as in floors and surfaces finished even & rough to recive the floor tiles etc ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 50mm thick cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3metres interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand) ; complete all as specified and directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) ground floor to 4th floors and pavings not exceeding 15cm thickness (below or above ground level ) and removing the rubbish from the work site out side defence premises ; complete all as specified and directed by the Engineer-in-Charge.
Taking up or down steel water tubing of 15 mm bore pipe and connections,including cleaning for re-fixing or removal to store ; complete all as specified and directed by the Engineer-in-Charge.
Taking up or down steel water tubing of 20 mm bore pipe and connections,including cleaning for re-fixing or removal to store ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing GI tubes 'medium grade' galvanised, 15 mm bore, ISI marked with all fittings such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors Including cutting hole in brick/concrete wall ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for GI tubes 'medium grade' galvanised, 20 mm bore, ISI marked with all fittings such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors Including cutting hole in brick/concrete wall ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for cutting chases, pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring,etc,and making good,cutting n.exc 10 cm girth in brick walls ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs angle valve with wall flange , cast copper alloy, chromium plated fancy type screwed for 15mm iron pipe ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs two way angle valve with wall flange , cast copper alloy, chromium plated fancy type screwed for 15mm iron pipe ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Bib taps, 15mm dia long body fancy type,chromium plated , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs 15mm dia chromium plated brass wall mounted sink mixer swan neck type for mixing hot & cold water screwed down for iron pipe including necessary fitting ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repair 15mm dia CP Central hole basin mixer cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs 15mm dia CP brass wall mixer 03-in-01 with provision of over head shower system (quarter turn) for mixing hot & cold water screwed down for iron pipe including necessary fitting ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs chromium plated shower rose 125mm square size with arm 15mm dia 195mm long with bend 45 degree with brass flange ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs PVC connection 15mm x 600mm including PTMT check nut at both ends screwed for iron pipe of 15 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs kitchen or laboratory sinks made of 1mm thick stainless steel sheet , with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm complete with waste coupling 100mm dia & PVC waste pipe 32mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Stainless Steel Kitchen plate rack for made out of 1 mm thick sheet and having partions as per sample. The over all size (30"x36"x10") fixed with steel fastners or steel screw ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs vitreous chinaware white wash hand basin with pedestal of size 58cm X 45cm complete including CP Waste coupling ,waste pipe of 32 mm ,complete fixing arrangement and cutting for and pinning in walls & making good ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs vitreous China corner wash hand basin, size 525 mm x440 mm x 140 mm or suitable size & any design approved by GE , Incl waste coupling and 900 mm long 32mm bore HDPE waste down pipe including Mild steel brackets ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs WC Orissa pattern white with integral foot rest 580mm x 440 mm including S/P traps & PCC bedding in 1:2:4 type B1 using 20mm graded crushed stone aggregates and making good disturbed floor connecting to trap and flush pipe ; complete all as specified and directed by the Engineer-in-Charge.(Rate of including in taking out and removal of old WC seat unhygienic condition)
Supply and fixing in repairs vitreous china wash down water closet pan (trap S/P type) (Pedestal pattern) white, including PVC Seat cover for EWC pan (White ) of standard quality including hinges bolt ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs PVC valveless,syphonic action type, dual flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm 'L' bend for IWC and EWC of capacity 10 litres and making good to dismantled/damaged floor/surfaces, fixing in repair ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Towel Rail 600mm long of stainless steel fixed with and includiing chromium plated brass screw and wooden/ Plastic cleats. (Minium weight 190gms) ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs stainless steel Soap Dish/Oval suitable size ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Glass Shelf 450 mm long ; complete all as specified and directed by the Engineer-in-Charge.
Dismantling PVC/Cement/CI pipes 50mm to 110mm dia including all fittings like bend,branch pieces, connectors, heel rest bend etc Incl Cutting through brick/RCC/PCC Wall and removing from site ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC (SWR) type B pipes 110mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC (SWR) type B pipes 110mm bore single socketed, in any length with rubber ring joints fixed to walls ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC (SWR) type B pipes 75mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC(SWR) type B pipes 75mm bore single socketed, in any length with rubber ring joints fixed to walls ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, UPVC (SWR) , bends with access door for 75 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, UPVC(SWR) , bends with access door, for 110 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing PVC (SWR) 110mm branch piece, single (single Y) equal or unequal ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC(SWR), junction single, (single 'T') equal or unequal for 75 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC(SWR), junction single, (single reducer 'T') equal or unequal for 110mm x75 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, UPVC(SWR), junction single, (single 'T') with access door equal or unequal for 75 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, UPVC(SWR), junction single, (single 'T') with access door equal or unequal for 110 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, UPVC (SWR) , bends for 75 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, UPVC(SWR) , shoes bends for 110 mm bore ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repair UPVC (SWR) Floor trap plain wih stainless steel grating having dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregates ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC (SWR) multi floor trap plain with stainless steel grating having dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregates ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC (SWR) vent cowl 75 mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing UPVC (SWR) vent cowl 110 mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quoin, arches pillars but excluding ashlar facing dressed stone work and precast concrete article, with & including Removing mortar from and cleaning useable bricks, stacking for measurement including all extra handling and removal and disposing off rubbish ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Brick work using old useable bricks retreived from demolition (serial item no.109 above), straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 ; complete all as specified and directed by the Engineer-in-Charge.
Taking down cement plaster (Height up to 4th story) on brick or stone walls or stone walls etc, including raking out joints, hacking for key, scrubbing down with water, etc ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for rendering 15mm thick (Height up to 4th story) on fair faces of brick or concrete surface walls, in cement mortar (1:4) , rendering is to be finished even and smooth without using extra cement (up to 4th storey with necessary scaffolding ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour rendering 15mm thick (Height up to 4th story) on fair faces of brick or concrete surface walls, in cement mortar (1:6) , rendering is to be finished even and smooth without using extra cement ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for rendering 5mm thick (Height up to 4th story) on fair faces of concrete surface of ceilings, in cement mortar 1:3, rendering is to be finished even and smooth without using extra cement ; complete all as specified and directed by the Engineer-in-Charge. Note for Srl Item No. 112 to 115 :- Work under Srl Item No. 112 to 115 of BOQ shall be carried out up to four storey height buildings and the necessary scaffolding, trestles, ladders, craddles necessary for execution of work and protective measures , safety measures shall be arranged by the contractor for labour at thier own & rates quoted by the contractor are inclusive of this aspect.
Material and labour for applying one coat of synthetic enamel paint on old painted steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth and apply one coat of primer where requred ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for complete removal of existing treatment on wall/Ceilling, roof projectios, including facia, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 60 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour (up to 4th storey with necessary scaffolding); complete all as specified and directed by the Engineer-in-Charge.
Material and labour for water proof cement based putty @ 1 Kg (undiluted) Per Square Metre of average thickness 1mm over the plastered / old prepared painted exterior wall surfaces (up to 4th storey with necessary scaffolding) with & including prepration of surfaces by scrapping to prepare the surface, and sanding of the putty surfaces with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pads of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps :- Step 1 :- Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of minimum 2.5 kg putty per minute. Step 2 :- Apply the first coat of prepared mixer with the help of fully automatic airless spray machine of putty application, finishing the surface even and smooth in level without any undulations and sanding of the putty surfaces with mechanical wall sander. Step 3 :- Allow 6 to 8 hours time to dry the putty surfaces, & Apply the further coat of prepared mixer with the help of fully automatic airless spray machine of putty application to meet the requirement, finishing the surface even and smooth in level without any undulations & sanding of the putty surfaces with mechanical wall sander.
Material and labour for one coat of water based premium acrylic smooth exterior grade primer @ 0.9 Litres (undiluted) Per Ten Square Metre diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 Litre per minute having a pressure of 3300 PSI and Allow 6 to 8 hours to dry the surface for painting of subsequent coats (walls up to 4th storey with necessary scaffolding) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50 Antifugal, Anti Algai properties in two coats @ 1.79 litres (unndiluted) Per Ten Square Metre diluted with water as per manufacturer instructions applied over priming surface with fully automatic airless spray machine of paint application with a flow speed of min 1litre per minute having a pressure of 3300 PSI & Allow 6 to 8 hrs to dry the surface in between subsequent coats of paint (up to 4th storey with necessary scaffolding) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for water proof cement based putty @ 1 Kg (undiluted) Per Square Metre of average thickness 1mm over the plastered / old prepared painted interior wall / ceiling surfaces (up to 4th storey with necessary scaffolding) with & including prepration of surfaces by scrapping to prepare the surface, and sanding of the putty surfaces with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pads of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps :- Step 1 :- Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of minimum 2.5 kg putty per minute. Step 2 :- Apply the first coat of prepared mixer with the help of fully automatic airless spray machine of putty application, finishing the surface even and smooth in level without any undulations. Step 3 :- Allow 6 to 8 hours time to dry the putty surfaces, Apply the further coat of prepared mixer with the help of fully automatic airless spray machine of putty application to meet the requirement, finishing the surface even and smooth in level without any undulations.
Material and labour for one coat of water based premium acrylic smooth interior grade primer @ 0.9 Litres (undiluted) Per Ten Square Metre diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 Litre per minute having a pressure of 3300 PSI and Allow 6 to 8 hours to dry the surface for painting of subsequent coats (walls up to 4th storey with necessary scaffolding) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for water based premium acrylic smooth interior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50 Antifugal, Anti Algai properties in two coats @ 1.79 litres (unndiluted) Per Ten Square Metre diluted with water as per manufacturer instructions applied over priming surface with fully automatic airless spray machine of paint application with a flow speed of min 1litre per minute having a pressure of 3300 PSI & Allow 6 to 8 hrs to dry the surface in between subsequent coats of paint (up to 4th storey with necessary scaffolding) to interior wall / ceiling surfaces ; complete all as specified and directed by the Engineer-in-Charge. Notes for Srl Item No.117 to 122 of BOQ :- The rates quoted by the bidder for Srl Item No.117 to 122 of BOQ shall also includes the under mentioned aspects and & nothing extra shall be payable :- (a) Work shall be carried out by the authorised applicator of manufacturer of water based premium acrylic smooth exterior emulsion , Contractor shall submit a triparty agreement MoU (between contractor, said manufacturers of and their Authorised Applicator) on Non Judicial Stamp Paper to GE and shall be approved by the GE before commencement of work at site (Refer Schedule "A" notes). (b) Work shall be carried out up to 4th storey height buildings and the necessary scaffolding, trestles, ladders, craddles necessary for execution of work and protective measures , safety measures shall be arranged by the contractor for labour at thier own & rates quoted by the contractor are inclusive of this aspect. (c) Removing of nails & making good holes, cracks etc. (d) Work in patches and in narow / widths, bands, cornices, plasters etc shall also be carried out and cutting in edge to line, where necessary. (e) Spreading and removing covering to doors, windows, floor, fittings etc and to protect them from splashes. (f) Washing floors, cleaning glass , joinery, electric fittings, wrining etc from drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (g) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work at site.
Material and labour 75mm thick Cement Concrete type D-2, 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to floors 75mm thick ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in sub base to floors ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for 60mm thick factory made chamfered edge cement concrete paver block made of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Chequered Cement concrete tiles 30cm x 30cm and 25mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey pigment cemen tand pigments and in floors, and cut and polished , over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 20mm thick cement concrete tiles, of size 30cm X 30cm with grey cement and pigment , jointed & pointed in cement mortar (1:3 and laid over 15mm thick bedding layer in cement mortar 1:4 ; complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing stainless steel peg set of six hooks ; complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing fancy type glass corner shelf 300 mm radius made of 5 mm thick toughened glass with CP railing fixed with screw ; complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing CP nozzle for aqua guard water purifier ; complete all as specified and directed by the Engineer-in-Charge.
Supply, Repair and Fixing of Single 110 mm PVC / SWR down take pipe fixing done with Pipe Supporting Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Mounted System-110 mm (4") Dia PVC/SWR pipe running vertically with wall distance 75 mm (3") ;Pipe Support Clamping made of :- (a) Profile Bracket having Wall Distance 75 mm (3") made of Low Carbon Hot Roll Gauge Corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm width x 3 mm thickness with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921 and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. (b) Continuous Slotted "C" Channel with ribs to be used of size 250 mm (10") made of Low Carbon Hot Roll Gauge Corrected Oil Pickeled & Drawn (HROP D) steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. (c) U bolt Rubber Mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 1000 hrs with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing:- As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade :- IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty :- for one unit :- (i) Profile Bracket Wall distance 75 mm (3") - 2 Nos. , (ii) Continuous Slotted C Channel of Size 250 mm (10") - 1 No ,(iii) U Bolt for 110 mm (4") dia PVC / SWR Pipe - 1 No. (iv) Fixing Nail of thickness 6.5 mm and length 63 mm (2 1/2"); Zn coated - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance. Make : ISI Marked as approved by GE.
Supply, Repair and Fixing of Single 75mm PVC / SWR down take pipe fixing done with Pipe Supporting Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Mounted System - 75mm (3") Dia PVC / SWR pipe running vertically with wall distance 75 mm (3") ; Pipe Support Clamping made of :- (a) Profile Bracket having Wall Distance 75 mm (3") made of Low Carbon Hot Roll Gauge Corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm width x 3 mm thickness with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921 and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. (b) Continuous Slotted "C" Channel with ribs to be used of size 250 mm (10") made of Low Carbon Hot Roll Gauge Corrected Oil Pickeled & Drawn (HROP D) steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. (c) U bolt Rubber Mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 1000 hrs with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing:- As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade :- IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty :- for one unit :- (i) Profile Bracket Wall distance 75 mm (3") - 2 Nos., (ii) Continuous Slotted C Channel of Size 250 mm (10") - 1 No. , (iii) U Bolt for 110 mm (4") dia PVC / SWR Pipe - 1 No. , (iv) Fixing Nail of thickness 6.5 mm and length 63 mm (2 1/2"); Zn coated - 4 nos. , Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance. & Make : ISI Marked as approved by GE.
Material and labour for capillary rise treatment of wall base coat ; Berger HS latex plus (or equivalent) consumption base coat; 0.3 kg/Sqm " Second and third coat ; Lates shield 2K (or equivalent), Consumption top coat : 3kg/Sqm system requirement density; 2.0 kg; Compressive strength ; 0.5 N/Sqmm, ; complete all as specified and directed by the Engineer-in-Charge..
Material and labour post construction anti termite treatment of soil under existing floor and plinth protection using emulsion @ 1 litre per hole; 300mm apart including drilling and plugging 12mm dia hole with cement mortar 1:2 (1 cement ;2 coarse sand) to match the existing floor; complete all as specified and directed by the Engineer-in-Charge's.
Removing/Chipping and cleaning of existing concrete carefully by low impact high frequency hammer without damaging the existing concrete for any thickness all as specified and as per manufacture instruction (area of loose concrete shall be considered for payment) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour applying two coats of alkaline rust converting primer of approved quality on existing reinforcement having dia 8mm and more including cleaning the reinforcement wire brushing to remove loose rust spalls as per manufacture instructions(Length of reinforcement bars shall be measured for payment) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for providing anti corrossive treatment of reinforcement by any approved make rebar corrossion protection system to existing reinforcement having dia 8mm and more, process is to be completed as per manufacturer instructions (exposed length of reinforcement bars shall be measured for payment) ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for applying two component epoxy resin concrete bonding coat on prepared RCC surface as per manufacturer specifications including preparition of surface ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for applying in layers up to 20mm thickness pre-batched one component polymer modified dual shrinkage compensated cementious patch repair mortar over slab, beam, columns, staircase slabs chejjas etc ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for applying in layers above 20mm thickness pre-batched one component polymer modified dual shrinkage compensated cementious patch repair mortar over slab, beam, columns, staircase slabs chejjas etc ; complete all as specified and directed by the Engineer-in-Charge.
Supply, laying for underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 50 sq mm 3.5 core cable confirming to IS-7098 Part-I (1988) with latest ammendments including taking out the old unserviciable cable fropm the trenches ; complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5metre in width and not exceeding 1.5metres in depth and getting out in any type of soil ; complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm ; complete all as specified and directed by the Engineer-in-Charge.
Removal of excavated surplus material to a distance not exceeding 50metres and depositing where directed at a level not exceeding 1.5metres above the starting point ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for cutting of bituminous road / floor / culvert / PCC hard standing for laying of pipe / cables not exceeding 1.5 metre wide and not exceeding 1.5 metre deep including refilling with material, watering, well ramming / compacting and making good with PCC 1:2:4, type B-1( using 20 mm graded crushed stone aggregates ) 100 mm thick ; complete all as specified and directed by the Engineer-in-Charge.
Supply & laying for dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying,stretching and testing the cable in trench ; complete all as specified and directed by the Engineer-in-Charge. Note :Only the punned thickness shall be measured for payment purpose.
Supply & laying for sub class 'B' dry bricks old size laid flat over the cable abutting each other as mechanical protection, length of cable equal to width of brick ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for GI pipe ''light grade'' for road crossing / on wall / on pole with fixed clamps, nuts, bolts for cable protection of size 40 mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Material and labour for GI pipe ''light grade'' for road crossing / on wall / on pole with fixed clamps, nuts, bolts for cable protection of size 80 mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Taking up or down GI pipe with all fittings including cleaning of old pipe for refixing of size 50mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Taking up or down GI pipe with all fittings including cleaning of old pipe for re- fixing of size 20mm/25mm dia ; complete all as specified and directed by the Engineer-in-Charge.
Supplying, laying, jointing & testing in replacement of galvanised steel tubing 20mm bore medium grade with screwed joint together with all fitting such as bends, elbows, tees, short pieces and union etc laid in wall/roof/ceiling including connection of over head tank with floot valve ; complete all as specified and directed by the Engineer-in-Charge.
Supplying, laying, jointing & testing in replacement of galvanised steel tubing 50mm bore medium grade with screwed joint together with all fitting such as bends, elbows, tees, short pieces and union etc laid in wall/roof/ceiling including connection of over head tank with floot valve ; complete all as specified and directed by the Engineer-in-Charge.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) of size 50mm bore with screwed joint together with all fitting such as bends, elbows, tees, short pieces and union etc laid in wall/roof/ceiling including connection of over head tank with floot valve ; complete all as specified and directed by the Engineer-in-Charge
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) of size 25mm bore with screwed joint together with all fitting such as bends, elbows, tees, short pieces and union etc laid in wall/roof/ceiling including connection of over head tank with floot valve ; complete all as specified and directed by the Engineer-in-Charge
Supply and fixing in repairs of gun metal gate valve with iron wheel head 50mm ISI marked including dismantling & taking down the old unserviciable valve ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs of gun metal gate valve with iron wheel head 25mm ISI marked including dismantling & taking down the old unserviciable valve ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of gun metal gate valve with iron wheel head 20mm ISI marked including dismantling & taking down the old unserviciable valve ; complete all as specified and directed by the Engineer-in-Charge.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials for taking credit and making good disturbed surfaces of walls, floors and roofs etc all as specified and as directed.
Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed.
Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting and making good disturbed surfaces complete all as directed.
Material & labour for Point Wiring for One Light / Fan/ Exhaust Fan point controlled by one, one way switch 6 Amp , with cable of size 1.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One Light point controlled by two, two way switches 6 Amps , with cable of size 1.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One Fan/ Exhaust Fan point controlled by one switch 6 Amps & one regulator, with cable of size 1.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One bell/ buzzer point controlled by one switch 6 Amps, with cable of size 1.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One 3 pin switch socket outlet point 5 Amps on independent board, with cable of size 1.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One 3 pin switch socket outlet point 5 Amps on same board with other switches, with cable of size 1.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One 3 pin switch socket outlet point 15 Amps on the independent board , with cable of size 2.5 Sqmm multi stranded copper conductor FRLS insulated and unsheathed Meadium duty cable in colour code including continuous earth wire with cable of size 2.5 sqmm copper conductor flexible FRLS insulated drawn in and including new concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , including new modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer in Charge.
Material & labour for Point Wiring for One Light / Fan/ Exhaust Fan point controlled by one, one way switch 6 Amp , with cable of size 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed meadium duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn through existing concealed PVC/Steel conduit and accessories, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc ; complete all as specified and as directed by the Engineer in Charge.
Material & labour for Point Wiring for One 3 pin switch socket outlet point 5 Amps on independent board , with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed meadium duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated ISI marked drawn through existing concealed PVC/Steel conduit and accessories, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc ; complete all as specified and as directed by the Engineer in Charge.
Material & labour for Point Wiring for one 3 pin socket outlet 16 Amp independent , with cable of size 2.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed meadium duty cable in colour code including contineous earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated ISI marked drawn through existing concealed PVC/Steel conduit and accessories, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc ; complete all as specified and as directed by the Engineer in Charge.
Supply and fixing Modular Switch, one way 6 Amps , 1 module ; complete all as specified and directed by the Engineer-in-Charge. 1 module
Supply and fixing Modular Switch, Two way 6 Amps , 1 module ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Modular Switch, one way 16 Amps, 1 module ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Modular Socket 2/3 pin, 6 Amps 2 module ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Modular Socket 3 pin, 6 A/16 Amps 2 module ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Modular Bell push flush type SP 6 Amps, 1 module ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface backlite 65 mm x 50 mm 2/3 terminals ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing lamp holder PVC type with back plate for lamp holder fitting ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED lamp suitable for B22 holder of capacity 10 Watt ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing call bell (Ding Dong) 240 V, 50 Hz with PVC rectangular block for mounting of call bell Size of Block 175 mm x 100 mm x 50 mm ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED Light Fitting 1 x 18 Watts, 220 Volts, Batten integrated LED chanel fitting integral sleek extruded polycarbonate LED chanel with acrylic cover, cool day white with all accessories ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED Light Fitting 10 Watt Batten integrated LED chanel fitting integral sleek extruded polycarbonate LED chanel with acrylic cover,Neutral/cool day white with all accessories ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing energy saving new generation LED Light Fitting 10Watt , IP65 bulk head luminaire with opal diffuser ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclosure distribution board SPN 8 way 240 volts with IP 43 protection and double door, Bus bar rating 100 Amps, suitable for mounting MCBs ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB, single pole, 240 volts, 6 to 32 Amps with rupturing capacity 10KA, ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB, single pole & neutral, 240 volts, 32 to 63Amps with rupturing capacity 10KA, ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for submain wiring with two run of 6 Sqmm FRLSH PVC insulated copper conductor alongwith one run 6 sqmm earth wire of FRLSH PVC insulated copper conductor single core cable , multistranded with and including suitable size of PVC concealed conduit and all accessories concealed in walls / roofs / ceiling etc. earth dolly, terminated in terminal box ; complete all as specified and directed by the Engineer-in-Charge. Note :- Two runs (2 x 6 Sqmm) of copper conductor and one run of earth copper conducter (1 x 6 Sqmm) shall be measured as one length .
Taking down and refixing of Ceiling fan any size/sweep, including oiling, Greasing and cleaning and applying two coats of synthetic enameled paint after preparation of surface complete over a coat of primer ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing ceiling fan complete with blades with clamp, Hooks and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compatible with modular electronic regulator of any make and fixing of hook by anchor fastner ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Anti Suicide Fan Rod of suitable size and length with the provn, If the load on fans exceeded 22 kgs, than the smart rod/pipe opens from its centre and spring in the pipe expands, The fan Rod should be tested at Govt of India's MSME Labs for its functinaly and the test report from Labs should be submitted to the Engineer in Charge installation ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing of exhaust fan, steel body AC single phase. 230 V of size 300 mm sweep with, blades, frame and louvers and including making of holes in walls etc and making good the disturbed surface as per existing ; complete all as specified and directed by the Engineer-in-Charge.
Taking down and refixing of Exhaust fan any size/sweep, including oiling, Greasing and cleaning and applying two coats of synthetic enameled paint after preparation of surface complete over a coat of primer, ; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for complete earthing with galvanised mild steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR 2009 Part-I and testing on completion ; complete all as specified and directed by the Engineer-in-Charge.
Taking down existing electric meters of any type/capacity after disconnecting the electrical connections and depositing to MES store yard with and including refixing in the new location alongwith all electrical connections ; complete all as specified and directed by the Engineer-in-Charge.
Taking down existing geyser of any type/capacity after disconnecting the electrical connections and depositing to MES store yard with and including refixing in the same loaction after repair alongwith all electrical connections ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing electric water heater, Storage type steel body vertical type with Glass lined /porcelain enamel coated steel inner tank and glass line double ceramic heating element upto 2 kw capacity of 25 ltrs, BEE 5 Star rated complete with all accessories such as sefty valve, thermostate , NRV,connection piece etc. including anchor bolt fastners and making good surface as per existing wall ; complete all as specified and directed by Engineer In Charge.
Supply and fixing Vertical Distribution Board (VTP&N) 4 way double door suitable for and MCCB four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar ; complete all as specified and directed by Engineer In Charge.
Supply and fixing 4 Pole MCCB 63 Amp, 415 Volts with rupturing capacity 16 KA ; complete all as specified and directed by Engineer In Charge.
Material & Labour for wire sizes of 1.5 Sqmm FRLSH PVC insulated copper conductor single core cable , multistranded and including through of existing Concealed conduit and all accessories fixing on walls / roofs / ceiling etc for invertor connection ; complete all as specified and directed by Engineer In Charge.
Supply and fixing of 15 Amp Plug top 240 V, for invertor connection ; complete all as specified and directed by Engineer In Charge.
Supply and fixing modular type fan regulator step down type 120 Watt, 2 module ; complete all as specified and directed by Engineer In Charge.
Note: The schedule of credit has been attached in tender in PDF format and amount of credit schedule i.e. Rs 16,44,623.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.
GUPTA CONSTRUCTION (BID ID -3332029)
M/S Shesh Paul Gupta (BID ID -3332098)
bamral builder (BID ID -3331452)
vijay builders (BID ID -3330397)
PAWAN KUMAR (BID ID -3331917)
M/s Khajuria Construction Co. (BID ID -3330147)
mohanlal gupta (BID ID -3338916)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tenderdocument.pdf
Tender Documents • 3.26 MB
BOQ.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .