Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAdmitted-Finance | ₹3.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.6 Cr+₹14.5 L (4.22%)Admitted-Finance 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹3.6 Cr+₹14.5 L (4.22%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not Qualified |
| 4 | Rejected-Technical 6 LSC DDA MARKET PUSHPA BHAWAN COMPLEX MADANGIR SOUTH EAST DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | - | - | Rejected-Technical Technically not Qualified |
| Sl No | Description | Qty | Unit | Sharif ahmed and Sons L1 | SWASTIK ELECTROTECH PVT LTD L2 |
|---|---|---|---|---|---|
| 1.00Civil Work (A) | |||||
| 2.001) Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: | |||||
| 3.00 | 1.1) All kinds of soil | 200 | Sqm | 110 ₹22,000 Lowest | 110 ₹22,000 Lowest |
| 4.002.) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | |||||
| 5.00 | 2.1) All kinds of soil. | 10 | Cum. | 210 ₹2,100 Lowest | 295 ₹2,950 |
| 6.00 | 3)Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 10 | Cum. | 200 ₹2,000 Lowest | 265 ₹2,650 |
| 7.004) Supplying chemical emulsion in sealed containers including delivery as specified. | |||||
| 8.00 | 4.1) Chlorpyriphos emulsifiable concentrate of 20% | 50 | Ltr. | 200 ₹10,000 Lowest | 210 ₹10,500 |
| 9.005) Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : | |||||
| 10.005.1) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: | |||||
Tender Value
₹3.7 Cr
EMD Value
₹7.3 L
Closing Date
20 Oct 2023, 3:00 pmClosed
Executive Engineer
Office of the Executive Engineer (CD-I), Room No. AD-117A, Academic Building, IIT Delhi, Hauz Khas, New Delhi-110016
Comprehensive Maintenance of Civil work, Horticulture, Public Health Works, Service of Hospitality, Housekeeping, Pest Control and round the clock O and M of E and M services at Sonipat Campus of IIT Delhi
2023_IIT_776333_1
IITD/WORKS (SP-4377)/2022
Open Tender
Miscellaneous Works
Works
365 days
Indian Institute of Technology Delhi
As per tender document
16 documents required · 16 mandatory
₹1,500
Registrar IIT Delhi
₹7.3 L
7 Nov 2023
13 Oct 2023
23 Oct 2023
13 Oct 2023
20 Oct 2023
13 Oct 2023
Amount
Civil Work (A)
1) Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
1.1) All kinds of soil
2.) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.1) All kinds of soil.
3)Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4) Supplying chemical emulsion in sealed containers including delivery as specified.
4.1) Chlorpyriphos emulsifiable concentrate of 20%
5) Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
5.1) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:
5.1.1) With Chlorpyriphos E.C. 20% with 1% concentration
5.2) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
5.2.1) With Chlorpyriphos E.C. 20% with 1% concentration
6) Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
7) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
7.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
7.2) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
8) Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
9) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
9.1) Cement mortar 1:4 (1 cement : 4 coarse sand)
10) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
10.1) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
11.) 12 mm cement plaster:
11.1) 1:4 (1 cement : 4 fine sand)
12) 15 mm cement plaster:
12.1) 1:4 (1 cement : 4 fine sand)
13) Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
14) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
14.1) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
15.) Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
15.1) One or more coats on old work
16.) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
16.1) One or more coats on old work
17) French spirit polishing :
17.1) One or more coats on old work
18) Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
18.1) With cement mortar 1:4 (1 cement : 4 fine sand)
19) Providing and laying 60mm thick factory made cement concrete inter locking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
20) Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
20.1) Made of G.I. wire of dia 4 mm
21) Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
22) Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre leadas per direction of Engineer-in-Charge.
23) Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. (Old CC paver blocks shall be supplied by the department free of cost).
24) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
24.1) 15 mm nominal dia Pipes
24.2) 20 mm nominal dia Pipes
24.3) 25 mm nominal dia Pipes
25) Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
25.1) 15 mm dia nominal bore
25.2) 20 mm dia nominal bore
25.3) 25 mm dia nominal bore
26) Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
26.1) 25 mm nominal bore
27) Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
27.1) 20 mm nominal bore
27.2) 25 mm nominal bore
28) Providing and fixing gun metal non- return valve of approved quality (screwed end) :
28.1) 25 mm nominal bore
28.1.1) Horizontal
29) Providing and fixing uplasticised PVC connection pipe with brass unions :
29.1) 45 cm length
29.1.1) 15 mm nominal bore
30) Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
30.1) 100 mm diameter
31) Repainting G.I. pipes and fittings with synthetic enamel white paint with one coat of approved quality :
31.1) 20 mm diameter pipe
31.2) 25 mm diameter pipe
31.3) 40 mm diameter pipe
31.4) 50 mm diameter pipe
32) Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
32.1) 15 mm nominal bore
32.2) 20 mm nominal bore
32.3) 25 mm nominal bore
33) Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
34) Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
34.1) 15 mm nominal bore
35) Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
35.1) 15 mm nominal bore
36) Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
36.1) 15 mm nominal bore
37) Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
37.1) 15mm nominal bore
38) Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
39) Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection ofwork at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective ofduration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
40) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
(B) Up Keeping of Maintenance Work
41)Up-Keeping of maintenance work including day to day complaint servicing related to buildings, external landscape (Roads, boundary, footpath etc.), round the clock plumbing (internal/ external water supply, sewerage, drainage etc.), round the clock STP & WTP (operating Pumps, Motors, Starters and other allied services on Main Water Supply Pipeline Network and Tube well Pumps, Booster Pumps, Main Reservoir Plant, UG tanks, Overhead Tanks and STP including noting of Pressure Readings, Chlorination at various locations etc.), horticulture work (like grass cutting by hand/ machine and maintenance of flower beds, weeding, watering, hedge plantation and other gardening operations) and pest control etc. at all leads and lifts as per the schedule and directions of Engineer-In-Charge. Job work by specified nos. of workers with necessary tools required for 08 hours per day and 26 days per month as per the schedule. The detail of manpower to be engaged for above works mentioned at Annexure-A
41.1) Gardener/ Mali for Horticulture operations (As per deployment schedule to be approved by Engineer-In-Charge)
41.2) Helper/ Beldar/ Coolie for Civil Maintenance (As per deployment schedule to be approved by Engineer-In-Charge)
41.3) Valve/ Pump Operator for Civil Maintenance (As per deployment schedule to be approved by Engineer-In-Charge)
41.4) Mason for Civil Maintenance (As per deployment schedule to be approved by Engineer-In-Charge)
41.5) Carpenter for Civil Maintenance (As per deployment schedule to be approved by Engineer-In-Charge)
41.6) Plumber for Civil Maintenance (As per deployment schedule to be approved by Engineer-In-Charge )
41.7) Supervisor for Civil Maintenance (As per deployment schedule to be approved by Engineer-In-Charge)
Supply of Material
41.8) Providing specified quaintly required for upkeeping of maintenance work as per the schedule
41.8.1) Cement (PPC/OPC)
41.8.2) Stone aggregate 10 mm nominal size
41.8.3) Stone aggregate 20 mm nominal size
41.8.4) Find Sand / Jamuna Sand
41.8.5) Coarse Sand
41.8.6) Bicks of standard side class designation 7.5
41.8.7) Commercial wooden 19mm thick Board
41.8.8) 6 mm wooden ply
41.8.9) 12 mm commercial ply
41.8.10) Tape crete water proofing material
41.8.11) 15mm Ball cock (Float Ball Cock) complete set
(C) Housekeeping Services
42) Automated mechanized housekeeping services for I-Tech Building (Academia and Guest House Block), CRF Building, Staff Quarters, Basement and external landscape area at all leads and lifts by Sweeping, Mopping, Scrubbing, Buffing, Vacuum cleaning, Pressure washing etc. as per frequency of cleaning chart and directions of Engineer-In-Charge for period of one year including :
42.1) Job work by specified nos. of housekeeping workers required for 08 hours per day and 26 days per month as per the schedule.
42.1.1) Workers for Housekeeping Services (As per Schedule to be approved by Engineer-In-Charge).Staff to be trained to operate machines in the schedule)
42.1.2) Supervisor for Housekeeping Services (01 Nos. per day)
42.1.3) Manager for Housekeeping Services (01 Nos. per day)
43) Job work by various housekeeping machines/ equipments etc. required for 08 hours per day and 26 days per month as per the schedule.
43.1) Ride on Scrubber Drier(02 Nos. Per Day)
43.2) Back pack Vacuum Cleaner(03 Nos. Per Day)
43.3) Single Disc Scrubber (03 Nos. Per Day)
43.4) Heavy Duty High pressure Jet Washer(01 Nos. Per Day)
44) Providing specified quantity of Housekeeping chemicals, toiletries and consumable etc. required as per the schedule.
44.1) Bathroom Cleaner (R1), (20 Ltr. Per Month)
44.2) Hard Surface Cleaner/ All-purpose cleaning agent (R2) (20 Ltr. Per Month)
44.3) Glass Cleaner (R3), (15 Ltr. Per Month)
44.4) Furniture polish (R4), (10 Ltr. Per Month)
44.5) Toilet bowl cleaner (R6), (20 Ltr. Per Month)
44.6) Scale Remover (Removal of hard stains from Bathroom walls and Fittings (R9) (10 Ltr. Per Month)
44.7) Floor Cleaner for machines (R7 or Taski Spiral) (10 Ltr. Per Month)
44.8) Stainless steel polish,(10 Ltr. Per Month)
44.9) Wringers trolley (double Bucket 50Ltr, life 1 year)
44.10) Telescopic Rod (life 1 year)
44.11) Wash Room Cleaning kit holder within build stool ( life 1 year)
44.12) Sign Board (life 1 year)
44.13) Kentucky Mop (Life 6 month)
44.14) Dry Mop (Life 6 month)
44.15) Wiper (large) life 6 months
44.16) Wiper (Small) life 6 months
44.17) Dustbin capacity 100 ltr plastic (life 12 month)
44.18) Toilet Brush (life 3 months)
44.19) Dustbin foot operated for washrooms 15 ltr capacity (life 4 months)
44.20) Floor Scrubbing Brush with Handle (life 3 months)
44.21) Plastic Mug (life 6 months)
44.22) Kentucky Mop Refill
44.23) Dry Mop Refill
44.24) Odonil 100gm
44.25) Spray pump
44.26) Floor Duster Full size
44.27) Duster Check-Blue
44.28) Duster Check-Green
44.29) Vim Powder (1 kg Packet)
44.30) Scroch Brite (large)
44.31) Small chock pump
44.32) Plastic Juna
44.33) Broom Soft
44.34) Hard broom with long handle for Road sweeping
44.35) Face mask
44.36) Hand Gloves
44.37) Dustpan Plastic
44.38) Garbage bag big black
44.39) Garbage bag small Green
44.40) Glass squeeze
44.41) Feather Brush Heavy
44.42) Urinal Cubes
44.43) Urinal Screen V-Screen
44.44) Room Freshener
44.45) Hand wash liquid
44.46) Glass Cleaning kit (life 6 month)
44.47) Hit/ Bagyon spray
44.48) Terranova Marble Maintainer
(D) Hospitality services
45) Up-Keeping of Hospitality services for guest house including facility management/ room service, booking/ billing, check-in/ check-out of guest rooms etc. at all leads and lifts as per the schedule and directions of Engineer-In-Charge for period of one year including :
45.1) Job work by specified nos. of hospitality management workers required for 08 hours per day and 26 days per month as per the schedule.
45.1.1) Supervisor for Hospitality Management (01 Nos. per day)
45.1.2) Senior Accountant for Hospitality Management (01 Nos. per day)
45.1.3) Manager for Hospitality Management (01 Nos. per day)
Laundry Services and Rooms services
46) Providing laundry service for specified quantity of linen of guest rooms required as per the schedule.
46.1) Single Bed Sheet
46.2) Double Bed Sheet
46.3) Single Duet Cover
46.4) Double Duet Cover
46.5) Blanket
46.6) Pillow Protector
46.7) Hand Towel
46.8) Bath Towel
46.9) Curtain
47) Providing specified quantity of guest room ancilinaries, toiletries and consumable etc. required as per the schedule.
47.1) Bath soap bar (guest room pack 40 gm)
47.2) Toilet tissue paper roll (guest room pack)
47.3) Water bottle (1.0 ltr)
47.4) Tea/ coffee kit (single pack)
48) Disinfestations and Pest Control for I-Tech Building (Academia and Guest House Block), CRF Building, Staff Quaters, Basement and external lanscape area at all leads and lifts including deputing specialized manpower, application equipments and chemicals etc. as per frequency of treatment chart and directions of Engineer-In-Charge for period of one year including :
48.1) Effective disinfestations and satisfactory Pest Control Treatments designed through a program for reducing and controlling: Flies, American Cockroaches, German cockroaches, Lizards, Mosquitoes, Silverfish, Spider, Red ants and black ants, Rodents & Mice. (Termite & Bedbug Treatment not covered in this contract) Service Frequency & Manpower Employed : Agency will be deputing 2 Technician including reliever in all working days. 1 manager will visit fortnightly 1 Audit report of health & Hygiene shall be handover to you monthly/Bimonthly if required. Scope of Work : (i) C-GEL (Cockroaches Management Service) (ii) Crawling insect pest’s management (American Cockroaches, Silverfish, Spiders, red and black ants) (iii) House fly management (iv)Mosquito management services (v) ROD-X (Rodent Management Services)
ELECTRICAL WORKS
Operation & Maintenance manpower
1) Round the clock O&M of Electrical and mechnaical services of sonipat campus as per following
1.01) Operation &Maintenance [Routine & Preventive] and Break down maintenance of Complete Air-conditioning System of the Building including high side & low side of the Water Cooled Chiller Air conditioning plant (3 x 350 TR, Carrier make) comprising of all the machinery, equipment installed in the AC Plant room including cooling towers, Hot water cycle accessories, all AHUs and FCUs installed in building, VFDs, control panel, etc. for their proper operation.
1.02) Operation & Maintenance Routine & Preventive and Break down maintenance of the Complete Air Conditioning system of the Building including high side & low side of the Air Cooled Chilled water circulation Air conditioning plant (3 x 48 TR, Carrier make) comprising of all the machinery, equipment installed in the AC Plant room including all Air Handling Units (AHU), FCUs, VFDs, control panel, etc. for their proper operation.
1.03) Operation & Maintenance including Routine, Preventive and Break down maintenance of small AC units like Split, Window, Tower and Cassette type including their all accessories for proper cooling output at all times.
1.04) Maintenance including Routine, Preventive and Break down maintenance and daily checking of lifts installed in building including residential quarters for their proper operation at all times, proper ARD working, attending of lifts for rescue operation in case of exigency.
FIRE DETECTION AND FIRE FIGHTING SYSTEM
1.05) Maintenance including Routine, Preventive and Break down maintenance and daily checking of Fire Detection and Fire Fighting Systems installed in buildings including Automatic Fire Alarm Panels, Detectors, Fire pumps (main, DG, jockey), entire Wet Riser and Sprinkler System including all hydrants, hoses, proper operation of valves, and other portable extinguishing system periodical testing and checking and mock fire drilling etc. as required. The whole system should be ready at all times for detecting fire incidence and combating fire by use of pressurised wet riser system.
1.06) Maintenance including Routine, Preventive and Break down maintenance and daily checking of all pressurisation & mechanical ventilation fans installed in basement or elsewhere in the building for their proper operation at all times, VFDs, control panel, etc. as required.
ELECTRICAL SUBSTATION & POWER DISTRIBUTION
1.07) Routine, Preventive and Break down maintenance of HT Sub Station ensuring proper operation of transformers, HT switchgears, LT switchgears, all distribution panels, monitoring of load.
DG SET
1.08) Maintenance including Routine, Preventive and Break down Maintenance of 2X500KVA DG sets make Cotton grevaes & 1X500KVA make : KOEL for their proper operations at all times whenever required, six monthly servicing including replacement of all consumables etc. as required.
1.09) Maintenance including Routine, Preventive and Break down maintenance of all UPSs in the buildings for their proper operation at all times complete as required.
ON GRID SOLAR PLANT WITH SOLAR WATER HEATING SYSTEM
1.10) Maintenance including Routine, Preventive and Break down maintenance of rooftop on grid solar power generation plants including their all accessories for proper operation and generation of power, well maintaining of rooftop solar water heater systems for proper operations at all times complete as required.
RO SYSTEM / DRINKING WATER FILTRATION
1.11) Maintenance including Routine, Preventive and Break down maintenance of reverse Osmosis water filtration unit as required and water coolers for their proper operations.
DAY TO DAY COMPLAINT AND FAULT & MANNING / OPERATIONS OF SERVICES
1.12) Attending day to day complaints and rectifications faults relating to all sphere of Electrical & Mechanical activities pertaining to the entire building and periphery (compound lights), Maintaining of record in complaint register, repairing register, etc. Replacement of minor components like modular switches (upto 16/20 amp), sockets (upto 16/20 amp), copper electrical wiring of size (upto 6 sqmm), similar to existing make and model adhesive insulation tape as per requirement, tools and tackles, necessary instruments for measuring voltage and currents, continuity, megger, etc. shall be provided by the contractor as and when required.
DEPUTATION & MODALITY OF AT-THE-SITE WORKER
1.13) Providing following reserve manpower for manning, operation, attending day to day complaints / faults, testing, managing all E & M activities who shall be on duty in the building during the whole contract period. 1. Supervisor/ Foreman (Diploma in Electrical)/ITI Passed with 10Yrs. Exp. - 01 no. 2. AV operator/ technician (Diploma/ Degree in relevant field)-2 No. 3 Operator for Online complaint management - 01 no. 4. ESS operator/ DG operator/ Electrician (ITI passed)- 04 nos. 5. Electrician/ wiremen (ITI passed) - 7 Nos. 6. HVAC operator (ITI passed) - 7 Nos. 7. Firemen (having fire fighting certificate/diploma of 6 months/ 01yr.) - 04 nos. (round the clock) 8. Pump Operator (ITI passed) - 04 Nos. 9. Helper - 07 nos. Total 37 Nos. The above-mentioned manpower is responsible for round the clock operation of AC plants (person should be physically present at site round the clock), Testing, checking and operation of Fire detection and Wet Riser system, attending of lifts and rescue operation as and when required, day to day attending faults and repairing round the clock, operation of DG sets and logging of all operational services pertaining to fault, various parameters of AC plants, Fire Systems, Substation, DG set.
[1 job means -- Carrying out the scheduled work by providing the above-mentioned on-the-spot manpower and fulfilling Terms & Conditions as stipulated for a period of one month.
2) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
3) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5) Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
5.01) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
5.02) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
6) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. mm.
7) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
8) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
8.01) 5/6 A switch
8.02) 3 pin 5/6 A socket outlet
8.03) 15/16 A switch
8.04) 6 pin 15/16 A socket outlet
9) Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
10) Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
11) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
11.01) Upto 450 mm sweep
12) Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
12.01) 125 A,36KA,FPMCCB
12.02) 200 A,36KA,FPMCCB
12.03) 630 A,50KA,FPMCCB
13) supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
13.01) 8 way , Double door
14) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
14.01) 4 way (4 + 12), Double door
14.02) 8 way (4 + 24), Double door
15) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
15.01) Single pole
15.02) Double pole
15.03) Triple pole
15.04) Triple pole and neutral
16) Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
17) Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
18) Supplying and fixing DP sheet steel enclosure on surface/ recess Along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
19) Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required
20) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
21) Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
22) Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
23) Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
24) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
25) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
26) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
27)Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
27.01) 63 mm dia (OD-63 mm & ID-51 mm nominal)
27.02) 90 mm dia (OD-90 mm & ID-76 mm nominal)
28) Supply & fixing of Neoprene rubber coupling suitable for 20 HP 3 Phase motor pump set installed in HVAC plant of ITEC building including connection, testing, etc complete as required.
29) Supply & fixing of Belts A33 in existing AHUs installed in HVAC system of ITEC building including connection, testing, etc complete as required.
30) Supply & fixing of Belts A54 in existing AHUs installed in HVAC system of ITEC building including connection, testing, etc complete as required.
31) Repairing of PLC/controller synchronizing panel used for operation of 2X500KVA Dg set make cotton greaves including reformatting, programming, testing, checking of logic for DG1 and DG2for proper operation and load sharing etc complete as required as per the direction of engineer in charge.
32) Supplying and fixing of 9W white LED bulb including connection, testing, etc complete as required (make: Crompton /Havells / phillips.
33) Supplying and fixing of 15W recess mounting white LED light including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
34) Supplying and fixing of 150mm sweep, 25W exhaust fan having speed of 1300RPM & air delivery of 275cmm, including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
35) Supplying and fixing of 50W, 400mm wall fan having 1300RPM speed & air delivery of 60cmm, including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
36) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
37) Supplying and fixing of 60 W, IP66 LED flood light including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
38) Supplying and fixing of 100W IP66 LED flood light including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
39) Supplying and fixing of 300W IP66 LED flood light including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
40) Supplying and fixing of 24 W LED batten light 4ft including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
41) Supplying and fixing of 9 W LED batten light 1ft including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
42) Supplying and fixing of 36 W LED 2X2 panel including connection, testing, etc complete as required (make: crompton/Havells/phillips.)
43) Supply & fixing of 3KW capacity heater element in the existing tank of solar water heater system installed on rooftop of ITEC building including connection, testing, etc complete as required.
44) Supplying and laying of one number 4X25 Sqmm PVC insulated XLPE sheathe red Copper conductor, armored cable of 1.1KV grade on surface/cable tray etc complete as required.
45) Supplying and laying of one number 4X25 Sqmm PVC insulated XLPE sheathed aluminium conductor, armoured cable of 1.1KV grade on surface/cable tray etc complete as required.
46) Supplying and laying of one number 4X10 Sqmm PVC insulated XLPE sheathed aluminium conductor, armoured cable of 1.1KV grade on surface/cable tray etc. complete as required.
SWASTIK ELECTROTECH PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_816073.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .