Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAccepted-AOC BALIJAN PANIHARA GAON PO DINJOY CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹51.9 L+₹1.4 L (2.79%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹53.1 L+₹2.7 L (5.28%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹53.5 L+₹3.1 L (6.10%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹53.8 L+₹3.3 L (6.63%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 May 2024, 6:00 pmClosed
Garrison Engineer AF Mohanbari
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarh Assam 786012
REPAIR MAINT OF LT UNDER GROUND CABLE, JOINTS, OVERHEAD CONDUCTOR LINE, MAIN PANEL, MCCB, BUSBAR CHAMBER, LT ISOLATION AND CONNECTING ALLIED WORK AT AF STN MOHANBARI UNDER GE (AF) MOHANBARI
2024_MES_650092_1
8001/564/E8
Open Tender
Civil Works
Item Rate
270 days
Mohanbari
Class D category b i
7 documents required · 7 mandatory
₹500
Garrison Engineer (AF) Mohanbari
₹90,000
7 Jun 2024
15 Apr 2024
10 May 2024
15 Apr 2024
9 May 2024
2 May 2024
Amount
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed.
Excavation in trenches not exceeding 1.50 mtr wide but for additional 1.50 mtr (1.50 to 3.00 mtr ) depth or part there of in depth beyond the first 1.50 mtr for taking out / laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread thickness in any type of soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed. Note: Punned thickness of sand shall be measured & paid.
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed.
Relaying of serviceable bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 80 mm bore complete all as specified and directed.
Supply and fixing in replacement GI protection pipe of 25 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed. Note:- Earth work shall be measured and paid separately.
All as per item No. 9.00 above but pipe of 40 mm dia.
All as per item No. 9.00 above but pipe of 50 mm dia.
All as per item No. 9.00 above but pipe of 80 mm dia.
Taking out old serviceable/ unserviceable cable of size 16/ 25/ 35/ 50 Sqmm, 3.5/4 core of any make/ type and keeping aside for the purpose of rerouting/ relaying in new location/ for requisite replacement/ further disposal complete including taking out old bricks complete all as specified and directed. (Note: Earth work shall be measured & paid separately).
All as per item No. 13.00 above but cable of size 70/ 95 Sqmm
All as per item No. 13.00 above but cable of size 120/ 150 Sqmm
Supply, laying, jointing, testing and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor, 10 Sqmm, 2 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed. Note: Earth work shall be measured & paid separately.
All as per item No. 16.00 above but cable of size 16 Sqmm, 4 core
All as per item No. 16.00 above but cable of size 25 Sqmm, 3.5 core
All as per item No. 16.00 above but cable of size 35 Sqmm, 3.5 core
All as per item No. 16.00 above but cable of size 50 Sqmm, 3.5 core
All as per item No. 16.00 above but cable of size 70 Sqmm, 3.5 core
All as per item No. 16.00 above but cable of size 95 Sqmm, 3.5 core
All as per item No. 16.00 above but cable of size 120 Sqmm, 3.5 core
All as per item No. 16.00 above but cable of size 150 Sqmm, 3.5 core
Re-laying of serviceable (as obltained from taking out) cable of size 10/16/ 25/ 35/ 50 Sqmm, 2/3.5/4 core of any make/ type including making electrical connection complete all as specified and directed. (Note: Earth work shall be measured & paid separately).
All as per item No. 25.00 above but cable of size 70/ 95 Sqmm
All as per item No. 25.00 above but cable of size 120/ 150 Sqmm
Material and labour for heat shrinkable straight through joints suitable for LT PVC / XLPE insulated armoured aluminium conductor cable of size 10 sqmm to 50 sqmm, 2/3.5/ 4 core with jointing accessories including cutting of faulty cable complete all as specified& directed. Note: (i) Cutting of faulty cable/ joint is deemed to be included in the above quoted rates. (ii) If old burnt/ damaged LT cable/joint retrived will be issued to contractor as schedule of credit. (iii) Excavation and returning/filling required for straight through joints will be included in the quoted rate. If the excavation required more than 15 RM for joint of cable then it will be measured in respective item.
All as per item No. 28.00 above but cable of size 70 to 120 Sqmm
All as per item No. 28.00 above but cable of size 150 to 185 Sqmm
Dismantling of old unserviceable concrete poles of any size and type complete with insulators and cross arms including breaking of PCC foundation of pole after necessary earth work and returning filling of soil complete all as specified.
Dismantling of old unserviceable steel tubular/MS poles of any size and type complete with insulators and cross arms including breaking of PCC foundation of pole after necessary earth work and returning filling of soil complete all as specified and directed.
Supply and fixing steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including complete all as specified and directed.. Note:- Excavation, earth work and PCC Work will be measured and paid seperately in relavant items.
Material and Labour for repairs/replacement of stay assembly with accessories as shown in electrical plate No.1 complete with diameter of stay Rod 20 mm inclusive of loop type insulators, stay clamps including dismatling of old unserviceable stay assembly, loop insulators, stay rod complete including demolition of existing concrete complete all as specified and directed. Note :- Excavation , earth work will be measured and paid seperately
Material and labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of poles, stay etc complete all as specified and directed.
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping including necessary formwork, finished fair using exta cement complete all as specified and directed.
Supply and fixing in repairs anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole including dismantling old unserviceable complete all as specified and directed.
Supply and fixing of LT over head ACSR conductor (Squirral/ Weasel type) from pin, disc, shackle insulators with suitable binding wire to insulators including dismantling of existing unserviceable ACSR conductor complete all as specified and directed.
Supply and fixing of cradles, hexagonal/ rectangular, fabricated with galvanised steel wire 3.15 or 4 mm dia from LT overhead poles including dismantling of existing galvanised steel wire complete all as specified and directed.
Supply & fixing of pin type, porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100mm height, 65 mm dia for 1100 volts grade complete including dismantling old unserviceable all as specified and directed.
Supply & fixing of shackle type insulator porcelain virtuous white, brown or green, 75mm height, 90mm dia for 1100 volts grade including one galvanized mild steel straps washers insulator bolts washers and nuts including dismantling old unserviceable insulator complete all as specified and directed.
M&L for vice type connectors consisting of two brass plates, two steel bolts and nuts for 2 conductors of equal or unequal sizes for non-tension connections 'including treatment of connector and ACSR conductor with conducting jelly including taking down old one complete all as specified and directed.
M&L for PVC line separator suitable for 4 wire LT overhead lines at any height/ loaction complete all as specified and directed.
M&L for PVC line separator suitable for 2 wire LT overhead lines at any height/ location complete all as specified and directed.
M&L for restraining of LT overhead ACSR conductor from pin, disc, shackle insulators with suitable binding wire to insulators including dismantling of existing ACSR conductor for restraining and refixing same with connecting in position complete all as specified and directed.
M&L for restraining of cradles, hexagonal/ rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia from LT poles including dismantling of existing galvanised steel wire for restraining and refixing same with connecting in position to LT poles complete all as specified and directed.
M&L for tree trimming cut away dead or excess branches from trees or shrubs to maintain clearance along with over head power lines using climbing equipment and collecting the debris for disposal and removing broken limbs from electric wires by using hooked extension poles complete all as specified and as directed. Notes:- Span is taken as distance between two adjacent poles.
Supply and fixing in repair of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of 20x15cm size for LT system complete all as specified and directed.
Supplying and fixing in repairs 6 Sqmm twin core cable flat or circular stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed.
Supplying and fixing in repairs 10 Sqmm twin core cable flat or circular stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed.
S&F in replacement of MCB SP 6 to 32 Amps , 230 Volts, 10 KA, C curve type complete all as specified and directed.
S&F in replacement of MCB SPN 6 to 32 Amps , 230 Volts, 10 KA, C curve type complete all as specified and directed.
S&F in replacement of MCB TP 25-63 Amps , 415 Volts, 10 KA, C curve type complete all as specified and directed.
S&F in replacement of MCB TPN 40-100 Amps , 415 Volts, 10 KA, C curve type complete all as specified and directed.
S& F in replacement of MCCB, TPN 400 Amps, 36KA breaking capacity with overload and thermal tripping features, 415 volts, AC, 50 Hz complete with suitable spreader complete all as specified and directed. Note: Minor addition and alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
All as per item No. 55.00 above but TPN MCCB of 250 Amps, 25KA breaking capacity.
All as per item No. 55.00 above but TPN MCCB of 200 Amps, 25KA breaking capacity.
All as per item No. 55.00 above but TP MCCB of 125 Amps, 16KA breaking capacity.
All as per item No. 55.00 above but TP MCCB of 63/100 Amps, 16KA breaking capacity.
S&F in replacement of on load changeover switch four pole of 63 Amps., 415 volts, 50 Hz, open execution type complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates complete all as specified and directed.
S&F in replacement of on load changeover switch four pole of 100Amps., 415 volts, 50 Hz, open execution type complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates complete all as specified and directed.
S&F in replacement of on load changeover switch four pole of 200 Amps, 415 volts, 50 Hz in SS enclosure complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates complete all as specified and directed.
S&F in replacement of on load changeover switch four pole of 160 Amps, 415 volts, 50 Hz in SS enclosure complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates complete all as specified and directed.
Supplying and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006, (superseeding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply & fixing in replacement of flex fiber board of minimum thickness 5mm, surface/ wall mounting type, digitally printed with letters or figures (Block, Roman, Italic or Indian) as per sample including cutting into pieces as per site requirement complete all as specified and directed.
Material and labour for painting of erected steel tubular swaged poles of LT over head line (except embedded portion), 8.5/9 Mtrs long complete including all MS work mounted on pole, earth protection & water pipe (if exists) by necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and applying two coat of aluminium paint and providing 07 Nos bands/ straps with synthetic enamel paint (any tint 30 cm wide each) from top of plinth block and writing of pole number with white synthetic enamel paint on black ground complete all as specified and directed.
M&L for earthing complete with copper plate 600mm x 600mm x 3mm thick electrode and 20mm x 3mm copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to copper strip 20 x 3mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete including dismantling the old complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete including dismantling the old complete all as specified and directed.
Supply and fixing in replacement of copper strip 20mm x 3mm with fixing screws for conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed.
Supply and fixing in replacement of galvanised iron strip 32mm x 6mm with fixing screws for conductors/ earth lead including welding and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed.
Supply and fixing in repair of busbar chamber box AC 415 V, 50 Hz, 3 Phase, 4 wire wall mounting type structure of minimum size 0.6mx0.6mx0.45m with bottom cable entry with suitable cable glands structure made out of 2.0 mm thick CRCA steel sheet including 4 Nos aluminium bus bar 200 Amps supported on non hygroscopic fibres and brass screws having 4 Nos hole on each busbar with nuts, bolts & washers and suitable mounting arrangement for bus bars having sloping canopy at top with suitable locking arrangement duly powder coated finished complete all as specified and directed.
M&L in replacement of cross arms bracing supports clamps and back plates fabricated from structural steel section including nut, bolts, washers, welded, binding, cold as hot drilling holes for bolts in any shape or size as required duly painted with two coats of synthetic enemel paint over a coat of red oxide primer after preparation of surface complete all as specified and directed.
S&F in replacement of mild steel chequered plate Fe-410-W (gde-E-250), 7mm thick square cut or notched, forming holes without any attachment as duct covering size and length as approved including primer painting complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steek sheet 0.50 mm thick of Red colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixes with self tapping screws complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled spray painting of approved shade complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high as per colour scheme complete all as specified and directed.
M&L for repair/ maintenance of LT panel door by replacement of hinges and locking arrangement including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed. (Note: One side door will be measured & paid as one job).
Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.2mx0.9mx0.6m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- DETAILS:- INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity 35 KA of 250 Amps with fixed thermal and fixed magnetic setting- 01 Nos OUTGOING: (i) On Load Changeover open type 4 pole of capacity 250 Amps, 415 Volts, 50Hz - 01 Nos (ii) MCCB 4 Pole ,415 Volts with breaking capacity 18 kA of capacity 100 Amps with thermal magnetic release -01 Nos (iii) MCCB 4 Pole ,415 Volts with breaking capacity 18 kA of capacity 63 Amps with thermal magnetic release -02 Nos (one standby) (iv) MCCB 4 Pole ,415 Volts with breaking capacity 18 kA of capacity 40 Amps with thermal magnetic release -02 Nos (one standby) BUSBAR: (i) Aluminium bus bar 400 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 Nos INDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos. (ii) Digital ampere meter of 0-250 A, 3 phase, class 1, including CT having CTR 250/5 - 01 No (iii) Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No
Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.37mx1.80mx0.6m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- DETAILS:- INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity 36 kA of 400 Amps with fixed thermal and fixed magnetic setting- 01 Nos OUTGOING: (i) On Load Changeover open type 4 pole of capacity 400 Amps, 415 Volts, 50Hz - 01 Nos (ii) MCCB 4 Pole ,415 Volts with breaking capacity 36 kA of capacity 200 Amps with thermal magnetic release -01 Nos (iii) MCCB 4 Pole ,415 Volts with breaking capacity 18 kA of capacity 125 Amps with thermal magnetic release -02 Nos (iv) MCCB 4 Pole ,415 Volts with breaking capacity 18 kA of capacity 100 Amps with thermal magnetic release -02 Nos (one standby) (v) MCCB 4 Pole ,415 Volts with breaking capacity 18 kA of capacity 63 Amps with thermal magnetic release -01 Nos BUSBAR: (i) Aluminium bus bar 800 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 Nos INDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos. (ii) Digital ampere meter of 0-400 A, 3 phase, class 1, including CT having CTR 200/5 - 01 No (iii) Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No
M&L for shifting of LT panel of any size by disconnecting the cables of any size from panel and taking out the loop of the cable and shifting the panel within 500 mtrs from original location or as directed by Engr-in-Charge and reconnecting the same after dresseing the cable and providing suitable size lugs and glands for termination and connection with MCCBs after necessaey PCC plinth foundation work complete all as specified and directed. Note:- Demolition, transportation and lifting job and T&P are inclusive in the quoted rate.
Repair and maintenance of APFC Capacitor bank / LT Panel board upto 125 KVAR with 5/6 stage by chechking fault, weakness of capacitor and removing of fault including replacement of spare items complete including testing for proper automatic functioning complete all as specified and directed. Note :Spare items required for repair / maint shall be measured and paid seperately under respective items.
M&L for complete rewiring of APFC panel of up to capacity 125 KVAR by taking out burnt inter connection wiring including u/s and serviceable components for reuse and rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut, bolt, washer of various sizes, refixing serviceable items with auxiliary coil and testing complete for proper functioning complete all as specified and directed.
Supply only rectangular/ cylindrical heavy duty capacitor 3 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only rectangular/ cylindrical heavy duty capacitor 5 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only rectangular/ cylindrical heavy duty capacitor 10 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only rectangular/ cylindrical heavy duty capacitor 20 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only rectangular/ cylindrical heavy duty capacitor 25 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only power factor controller 30-525 Volts (mean Volatge), 230 Volts (supply voltage), 50 Hz, 6 steps, 3 phase complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only contactor 3 pole, 415 Volts, 50 Hz, 25 KW, minimum 50 Amps complete all as specified and directed. Make : EPCOS/ L &T / SIEMENS/ HAVELLS
Supply only Push switch for Manual ON/OFF of capacitor panel including making all electrical connection complete all as specified and directed.
Supply only LED Indicator as per Colour Scheme ( Red, Yellow, Blue, Green) Suitable for APFC / LT panel complete all as specified and directed.
Supply only voltmeter digital type 0-500 Volts AC, flush mounting type, 3 phase, class 1 complete all as specified and directed.
Supply only ammeter digital type, up to 400 Amps flush mounting type, 3 phase, class 1 with suitable CTs of range as required complete all as specified and directed.
Demolition and Dismantaling of Concrete of any description and in any position not otherwise specifically provided for LT Panel / AMF Panel / APFC Panel / Isolation Transfomer foundation complete including removal of old concrete complete all as specified and directed.
Material and labour for disconnecting of Electrical connection, earthing lead and taking out carefully defective Isolation Transformer of up to 75 KVA capacity located at AF stn Mohanbari including shifting it from AF stn Mohannari to Civil workshop by using mechanically operated crane and truck and back to its original position after necessary repairs and installing the Isolation Transformer inclusive reconnection of all electrical cables wires and earthing connection complete all as specified and as directed.
Material and labour for dismantling of Isolation Transfomer of capacity upto 75 KVA by disconnecting all internal electric connection after draining out of transfomer oil and storing the oil in transfomer oil barrel of cap 210 ltrs for reuse and opening the top cover of the isolation transfomer by removing nuts, bolts, washers, etc and lifing the core / winding by using indoor crane removing internal electrical connections by unscrewing nut, bolts, etc cleaning entire housing of transformers and dismantling complete primary / secondary winding from the limb and removed the entire tape insulation from the existing copper winding wire complete all as specified and as directed.
M & L for reinsulation of Primary coil of isolation transformer by using proper size of insulation paper sheet to entire copper winding wire complete all as specified and directed.
M & L for reinsulation of Secondary coil of isolation transformer by using proper size of insulation paper sheet to entire copper winding wire complete all as specified and directed.
Supply and fixing in repairs top cover gasket sheet as per exisiting size for various capacity of isolation transfomer complete all as specified and directed.
M & L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed. Note: (a) The filtration of the transformer oil shall be carried out at different locations of Air Force Station Mohanbari. (b) The report before filtration & after filtration to be submitted by contractor. (c) Transformer oil for topping up will be measured and paid separately.
Supply & toping up of new transformer oil (in sealed barrel) conforming to IS 335 Std having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified and directed. Make: Savita/ Castrol/ Poweroil/ Truoil.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of Isolation transformer of capacity upto 75KVA complete with all connected fittings & fixtures and other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction complete all as specified and directed. Note:- Contractor will apply one layer of grease over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
Supply and fix in replacement of air breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with new silica gel (blue in colour) suitable for Isolation Transfomer fixing on existing pipe of size 15/20/25 mm dia with suitable reducer/ connector complete as per site requirement complete all as specified and directed. Note:- Cost of modification (if required to fix on existing MS pipe) shall be deemed to included in the quoted rate against this item.
Supply and Fix in replacement of Silica Gel dehydrated blue coloured complete all as specified and directed.
KP GHOSH AND CO
S K ENTERPRISE
M/S S. P. ENTERPRISE
M/S RK Trading
D N ENTERPRISE
RAJ BUILDER
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .