| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.5 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹11.8 L+₹2,435 (0.21%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹12.0 L+₹16,270 (1.38%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹12.2 L+₹38,720 (3.28%)Rejected-AOC | 4 | Rejected-AOC 4th | |
| 5 | 5₹12.7 L+₹86,590 (7.34%)Rejected-AOC | 5 | Rejected-AOC 5th |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Sept 2021, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
Repair / Maint / Replacement of Internal Wiring alongwith accessories of LED Fittings, Panels, MCB/DBs Ceiling / Wall / Exhaust Fan and allied Electrical Works at VSV, MES Colony under GE(AF) Tughlakabad
2021_MES_467223_1
GE/TKD/TOKEN-30/2021-22
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class E or above category bi having deposited Standing Security of Rs. 50000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹40,000
Yes
29 Mar 2022
11 Aug 2021
10 Sept 2021
18 Aug 2021
8 Sept 2021
25 Aug 2021
Amount
Taking down old unserviceable aluminium point wiring (light/fan/socket power) complete with fitting/fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good the disturbed sufaces of wall and floors by applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable maint switches/DB's alongwith existing board including removing the same from site and making good the dusturbed surfaces by applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-charge
Taking down old unserviceable existing sub main wiring of any type and desription including removal of teak wood batten or pipe by applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-charge
Taking down old unserviceable/burnt, underground or service cable of any type & size complete all as specified and directed by Engr-in-charge
M&L for point wiring with copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2 runs of 1.5 Sq mm and 1 run of 1.5 Sq mm as in continuous earth wire drawn in to & including PVC conduit medium grade of 20 mm dia with fittings and accessories duly concealed by cutting chases, pinning in, making good in cement mortar 1:3 and making good the disturbed surfaces Cutting shall not exceed 4cm girth and 4cm width and applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-Charge for following:-
One light point controlled by one piano type switch, one way 5 Amp single pole.
One socket outlet 5/3 pin, 5 Amps controlled by one switch on same board.
One socket outlet 5/3 pin, 5 Amps controlled by one switch on independent board.
-ditto- all as item No 1 but for One 3 pin socket out let 15 amps on independent board with cable of size 2.5 Sqmm and 1.5 Sqmm as earth conductor.
S&F piano flush button single pole on way of 6 Amps complete all as specified and as directed by Engr-in-Charge.
M&L for switch socket combination 2 in 1, 3 pin 6 Amps flush type complete all as specified and as directed by Engr-in-Charge.
M&L for switch socket combination multipupose 2 in 1, 5 Amps and 16 Amps flush type complete all as specified and as directed by Engr-in-Charge.
M&L for lamp holder insulated body with back plate for batten fittings complete all as specified and as directed by Engr-in-Charge.
M&L for ceiling rose 3 phase PVC/polycarbonate isolated body complete all as specified and as directed by Engr-in-Charge.
M&L for socket outlet 3/5 Pin, 6 Amp flush type complete all as specified and as directed by Engr-in-Charge.
M&L in replacement of modular white cover plate with frame of 1 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame of 3 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame of 8 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular metal flush box for 1/2 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular metal flush box for 3 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular metal flush box for 8 module complete all as specified and directed by Engr-in-charge.
M&L in replacement for modular switch Piano flush type single pole one way 10 Amp 240 Volt AC complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular switch Piano flush type 16 Amp complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular socket outlet 6 Amp 2/3 pin 240 Volt multi socket for cell phone pin or 2 pin + 3 pin complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular socket outlet 16 Amp 2/3 pin 240 Volt twin socket heavy duty complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular bell push large piano type single pole one way 240 Volt AC complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for Ding Dong Bell/musical, single phase, 230 Volt complete all as specified and as directed by Engr-in-Charge.
M&L for sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed in brick wall/RCC as per the site condition providing 20mm dia PVC conduit with 2 runs of 4 Sqmm and 1 run of 4 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and as directed by Engr-in-Charge. Note: (i) The work includes cutting of Chassis and making good to match with surrounding necessary periodical applied one coat of putty and one coat of oil bound distemper to be included in quoted rate. (ii) One unit run include 3 runs of 4 Sqmm wire, 20 mm dia conduit shall be measured as one unit.
S&F of LED luminaire of size 600mm x 600mm of 35/36 Watt, 220 V, AC recessed type with high efficiency PMMA diffuser soft glare free light with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engr-in-Charge.
M&L for sheet metal enclosure for MCB's DB, single pole and neutral 8 way with 200 Amps rated bus bar, 240 Volts double door type complete all as specified and as directed by Engr-in-Charge. Make: Havells Cat Part No DHDPSHODRW08/Indo Asian Cat Part No 811807
M&L for sheet metal enclosure distribution board with hinged cover IP-43 protection metal door epoxy powder coated/made of insulating material like polystyrene, double door 4 way TPN with suitable rated bus bar for vertical operation incorporation of MCCB 4 pole of 125 Amps, breaking capacity 25 kA complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No DBPSG004DD of Indo Asian/Cat PArt No DHDLVDRWG0F008 of Havells
M&L for MCB SP 5-30 Amp, 10 kA breaking capacity 240 Volts complete all as specified and as directed by Engr-in-Charge.
M&L for MCB SPN 40-60 Amp, 10 kA breaking capacity 240 Volts complete all as specified and as directed by Engr-in-Charge.
M&L for MCCB 4 pole of 125 Amps with breaking capacity 16 kA, 415 Volts complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No 820243 of Indo Asian/Cat Part No IHLGNF0125# of Havells
M&L for concealed sub main wiring with PVC insulated unsheathed copper conductor 1100 Volt multistranded in and concealed in brick wall/RCC as per the site condition providing 25mm dia PVC conduit with 2 runs of 6 Sqmm and 1 run of 4 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and as directed by Engr-in-Charge. Note: (i) The work includes cutting of Chassis and making good to match with surrounding necessary periodical applied one coat of putty and one coat of oil bound distemper to be included in quoted rate. (ii) One unit run include 2 runs of 6 Sqmm wire, 1 runs of 4 Sqmm wire, 25 mm dia conduit shall be measured as one unit.
M&L for Earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC 1:3:6 type, C-1 pit with precast RCC Cover slab 40 mm thick in PCC1:2:4, type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe connected to earthing list point complete all as specified and as directed by Engr-in-charge.
S&F PVC 20mm casing 'N' caping of 2 mtr length complete all as specified and as directed by Engr-in-Charge.
S&F 5/6 Amp 3 Pin Top Plug complete all as specified and as directed by Engr-in-Charge.
S&F 15/16 Amp 3 Pin Top Plug complete all as specified and as directed by Engr-in-Charge.
S&F in replacement copper wire in wiring circuits as per site requirements PVC insulated FRLS single core 1.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
S&F in replacement copper wire in wiring circuits as per site requirements PVC insulated FRLS single core 2.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
S&F in replacement copper wire in wiring circuits as per site requirements PVC insulated FRLS single core 4 Sqmm 1100 volts grade multi stranded conductor complete all as specified and as directed by Engr-in-charge.
S&F in repairs twin core flexible wire 23/0076 complete all as specified and as directed by Engr-in-charge.
S&F in replacement of surface/wall mounted LED batten, polycarbonate housing provided with effiecient heat dissipation with diffuser and integrated electronic driver of 20 Watt rating suitable for 230 Volt, AC single phase, 50 Hz with all accessories prewired and 1 No LED tube and making necessary electrical connection with 3 core copper conductor and testing including taking down old batten fittings complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No LUMILINEBS20WLED865PCWH of Havells /Cat Part No LD00103031 of Polycab
S&F in replacement of PVC box suitable for 15/5 Amp socket size of box 7x4 complete all as specified and as directed by Engr-in-Charge.
Supply and laying of service cable/wire of 1100 Volt grade heavy duty with PVC insulated aluminium conductor served with an ainner sheathing of PVC tape armoured with tape and overall PVC sheathed of size 16 Sqmm two core nominal cross section complete all as specified and as directed by Engr-in-Charge.
Taking down carefully storage type water heater (Geyser) after disconnecting the inlet/outlet/vent pipes, electric/earth connections etc, cleaning of the body, inlet/outlet/vent pipes, leakage arresting of inner copper/steel tank by welding/brazing etc, reassembling the geyser by replacing gaskets worn out nuts, washers re-fixing the same in position, reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing leakages for proper functioning for various makes of geysers of 25 ltr capacity complete all as specified and directed by Engr-in-Charge Note: Necessary spare parts like Non return valve, stop valve, bib tap/ PVC connection /Copper connections cable, glass wool, element, thermostat, storage tank, geyser assembly, indicator etc shall be measured and paid separately.
Supply and replace the heating element with ISI marked element of capacity 1.5/2.0 Kilo Watt, suitable for 230 volts, AC, 50 Hz single phase power supply of storage type water heaters of compatible type duly making all connections by replacing inter connecting copper conductor cables and removal of the old unserviceable element complete all as specified and directed by Engr-in-Charge.
S&F thermostat suitable for 25/35/50 litres capacity storage type water heaters of size 9/11 inch long with temperature range of 0-90 degree centigrade including removal of old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F check/non return valve gun metal of size 15mm bore with necessary GI fittings required at site including removal of old one complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel assembly for housing the Heating element, 6/8/9 Holes type for 50/35/25 litres for storage type Geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel tank for 25 litres storage type Geyser with MS collar, as per existing pattern complete all as specified and directed by Engr-in-Charge.
S&F in replacement of glass wool for 50/35/25 litres storage type Geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement of safety valve suitable for storage type Geyser of capacity 50/35/25 litres, as per sample complete all as specified and directed by Engr-in-Charge.
S&F PVC insulated 3 core copper conductor wire of size 2.5 Sqmm overall PVC sheathed for Geyser connection including taking down old one complete all as specified and directed by Engr-in-Charge.
S&F in replacement of metal clad sheet metal plug and socket with 2 pin earth plug with one single pole MCB 240 Volts of 20 Amps and making all connections complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No DBMPS120SD of L&T/Cat Part No VYA120C of Hager/ Cat Part No 811050 of Indo Asian
S&F in replacement of metal clad DP socket & plug assembly AC, 220 Volt 50 Hz suitable for MCB of capacity of 20 Amps, with two pin and one earth pin and making all connections complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No DBMPS220S of L&T/Cat Part No 810390 of Indo Asian
S&F in replacement of metal clad sheet metal plug and socket triple pole and earth enclosure of capacity 32 Amps with one triple pole MCB of 415 Volt and making all connections complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No DBMPS220P of L&T/Cat Part No 810386 of Indo Asian
M&L for indicator lamp suitable for 25/35/50 litres geysers as per the existing sample in green and red colour including taking down old one complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of old painted surface of Geysers and applying two coats of synthetic enamel paint with machine spray paint including writing the MES number on body of the Geyser duly taking down and refixing the connections, testing and commissioning after painting complete all as specified and as directed by Engr-in-Charge.
S&F of GI tubing of medium grade fixed to walls and ceiling or laid in floors of size 15 mm including all accessories such as tee, bend, elbow, and union, taking down the existing pipes, connections and making good the disturned surfaces of walls to match with the existing surounding surfaces complete all as specified and as directed by Engr-in-Charge.
-Ditto- all as per sl item No 58 but for 20 mm dia.
S&F of 15 mm dia bore stop valve of male/female ends of classic handle type, chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipes complete all as specified and directed by Engr-in-charge.
S&F 15 mm dia bore bib taps cast copper alloy with crutch and butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-charge.
S&F PVC braided connection of size 15 mm dia, 450 mm length with nuts suitable for Hot & Cold water connections of geysers complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable exhaust fan and S&F exhaust fan with frame and louvers of size 300 mm sweep, 1400 RPM, 4 metal blade, double ball bearing type, metal body, ISI marked with copper winding suitable for 230 Volts, single phase, 50 Hz, 230 V, AC, 150 Watts with all connected accessories and depositing old fan at AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge. Make: Model-Turbo Force SP of 4 blade type of Havells/Model-SPH Turbo HDEF 4 Blade of Usha/Model-Freshee MK-II of 4 Blade of Bajaj
S&F in replacement of ceiling fan of 1200 mm sweep, three blade type with double ball bearing suitable for 230 volts, 50 Hz AC supply of 6 BEE, 5 star rating type with brushless direct current motro (BLDC) of copper wound with all standard accessories such as blades, down road, electronic fan regulator and taking down and depositing the old ceiling fan at AGE E/M store yard at Tech area complete all as specified and directed by Engr-in-Charge.
Taking out the old unserviceable geyser from the existing position and S&F, installation and testing of Geyser of 25 lItres capacity, storage type of 5 star rating suitable for 230 Volts, AC supply, 50 HZ complete with all standard accessories depositing the old geysers at AGE E/M store yard at Tech area complete all as specified and directed by Engr-in-Charge. Make: Havells Cat Part No SENZO25LTR/CG Cat Part No Arno Delux 25 Ltr/Venus Cat Part No MEGA PLUS 25ev
Supply only bituminous self adhesive flashing tape of size 100 mm x 50 mm x 10000 mm long Heavy duty, silver or black in colour as per sample complete all as specified and directed by Engr-in-Charge.
M&L for dash fastener and screws suitable for fixing/hanging electric geysers of capacity upto 50 ltrs fabricated with bronze and having 10 mm bore and 150 mm long with internal nails all as per sample kept at AGE E/M office complete all as specified and directed by Engr-in-Charge.
Taking down and servicing the ceiling fan of 12/1400 mm sweep at locations by removing old rease from bearing of ceiling fan and re-filliing new grease including replacement of the worn out nut bolt, bubber real bush, gun metal split pin, cleaning the entire fan unit by removing entire dirt, dust and wiping with soap water, cotton waste and commissioning, testing after asssembling, connecting to electric system complete all as specified and directed by Engr-in-Charge. Note: Other spare parts if any required except mentioned in the item will measured and paid separately in relevant items.
-Ditto- all as per sl item No 67 but for exhaust fan of size 230 mm to 300 mm sweep.
M&L for rewinding of single phase 220/230 Volt, AC ceiling fan of 1200/1400 mm sweep with copper wire of same gauge and quantity and replacement of unserviceable parts i.e. PVC connector, MS galvanised check nut, rubber pads, PVC strip clamps, washer packing, rubber packing and rubber seal including assembling, connecting, commissioning and testing complete all as specified and directed by Engr-in-charge.
-Ditto- all as per sl item No 69 but for exhaust fan of size 250 mm to 300 mm sweep plastic/mettalic type square or round shape.
S&F in replacement of capacitor 2.5 Mfd + 5%, 220/230 Volt AC 50 c/s complete all as specified and directed by Engr-in-Charge.
S&F in replacement of capacitor 3.15 Mfd + 5%, 220/230 Volt AC 50c/s complete all as specified and directed by Engr-in-Charge.
Remettling the worn out shaft of fan motor turning to obtain the standard dia of shaft for fixing standard size of bearing/bushes to ceiling fan of 12/1400 mm sweep of any make complete all as specified and directed by Engr-in-Charge.
Taking down the ceiling fan from its position and applying two coats of synthetic enamel paint with machine spray to ceiling fan of 1200/1400 mm sweep of any make to entire unit i.e. motor assembly, down rods and blades duly prepration of the surfaces including filling the cavities with filler and writing the MES number on body of the ceiling fans and refixing the connections, testing and commissioning after painting complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of canopy for ceiling fan of 1200/1400 mm sweep of any make complete all as specified and as directed by Engr-in-Charge.
S&F of down rod for ceiling fan 1200/1400mm sweep of size 15 mm dia of 700 mm long duly painted with approved synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S&F Hanging clamp suitable for the ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and directed by Engr-in-Charge.
S&F in replacement of step type modular electronic fan regulator, single phase 220 Volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of step type electronic fan regulator of the Flush type, single phase 220 V complete all as specified and directed by Engr-in-Charge.
Supply only LED 7 watts bulb BC type cool day light complete all as specified and directed by Engr-in-Charge.
M&L in replacement for exhaust fan motor for 300 mm sweep with all accessories and depositing old one in MES store at Tech area complete all as specified and directed by Engr-in-Charge.
Taking out the old unserviceable louvers of any type upto G+1 storey and S&F the exhaust fan louvers to suit 300 mm sweep exhaust fan made out of MS sheet heavy duty of 22 gauge as per sample kept at AGE E/M (AF) Tughlakabad duly applying two coats of paint over one coat of red oxide primer with all necessary fixing materials and making good the disturbed surface of wall both inner and outer side and match with the existing surfaces complete all as specified and directed by Engr-in-Charge. Note- Contractor will make all arrangements of safety devices and safety of their workmen and Govt property while carrying out the work.
-ditto- all as per sl item No 82.00 but to carry out the work at G+2 & G+3 of approximate height upto 10 meters.
M&L in replacement for fan blade set of 03 suitable for 1200 mm sweep as per sample complete all as specified and directed by Engr-in-Charge. Note: A set of 3 blades will measured as one unit of set.
M&L in replacement for fan blades set of 03 suitable for 1400 mm sweep as per sample complete all as specified and directed by Engr-in-Charge. Note:- A set of 3 blades will measured as one unit of set.
S&F in replacement for exhaust fan blade suitable for 300/450 mm sweep any make and as per existing colour including taking down complete all as specified and directed by Engr-in-Charge.
M&L in replacement of exhaust fan of 250 mm sweep ventilating fan, speed 1350 rpm and power 60 watts suitable for 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard complete all as specified and directed by Engr-in-Charge. Make: Bajaj Cat Part No Maxima DX/ Orient Cat Part No Ventilator DX/Havells Model-VENTIL AIR DX WHITE
S&F Ball bearing for 1200mm/1400mm sweep ceiling fan of any type suitable size complete all as specified and directed by Engr-in-Charge.
S&F Ball bearing of 12x32x10 mm size suitable for Exhaust fan of any type and size complete all as specified and directed by Engr-in-Charge.
Notes: The amount of Rs 25,520.00 against schedule of credit given on Tender Serial Page No 27 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
M/S S.K.Electricals
Bluemax Associate
akenterprises
AASHIANA CONSTRUCTION COMPANY
M/s.sagar enterprises
Deepak Electricals
M/s Sagar Construction Company
Surjit and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .