Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 2ND FLOOR PLOT NO E 19 104 155 BLOCK E P NO 19 SECTOR 3 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
25 Sept 2020, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer Project Airforce Palam Delhi Cantt-10
Soil Investigation for DEMOLITION OF J BLOCK QUARTERS AND RECONSTRUCTION OF THE SAME AND INCLUDING CONSTRUCTION OF DEFICIENT QUARTERS FOR AF CIVILIAN EMPLOYEES OF CAMERO COMPLEX
2020_MES_365109_3
3002/Q/03/E3
Open Tender
Job Works
Works
30 days
Garrison Engineer Project Airforce Palam
1 document required · 1 mandatory
₹0
Exempted
26 Sept 2020
4 Sept 2020
26 Sept 2020
4 Sept 2020
25 Sept 2020
4 Sept 2020
90 days
Job No : Air HQ/AMWP/08/19-20/AFRO Soil Investigation for DEMOLITION OF 'J' BLOCK QUARTERS AND RECONSTRUCTION OF THE SAME AND/ INCLUDING CONSTRUCTION OF DEFICIENT QUARTERS FOR AF CIVILIAN EMPLOYEES OF CAMERO COMPLEX. To carry out the test to ascertain soil profiles/proportion to determine safe bearing capacity complete with field and lab investigation according to relevant specifications of IS 2131, IS 6403, IS 1498, & IS 2720h supporting design details ofr the proposed 8th storeys (G+7) MD Accn type-II- 60 Nos Qtrs and 100000 ltrs capacity under ground water sump structures. The work shall be carried out as per the direction of Engineer- in-Charge.. Conduct soil investigation for following :- (a) 150 mm diameter bore hole : 10 Nos bore hole upto Depth 30 mtrs and 1 Nos bore hole upto Depth 12 mtrs as per IS Specification. (i) For Soil investigation = 11 Nos bore holes, as marked in sight plan. (b) Collection of disturbed and undisturbed soil sample at interval of 1.00 mtr or at change of strata or as per relevant IS Code. (c) Conduction lab test on disturbed soil sample as considered necessary according to relevant specification of IS 2720:- (i) Sieve analysis & Grain size distribution by sieve analysis & hydrometer test. (ii) Atterberg limits. (iii) Natural moisture content. (iv) Particle size analysis test. (v) Bulk density/ Dry density. (vi) Shear test. (vii) CBR Value Quotation attached Blocks)= 5X2= 10Nos sump=01 Nos total=11 Nos
(d) Conduct lab test on undisturbed soil sample as considered necessary according to relevant specification of IS 2720 and detailed result showing all relevant calculations, inferences, indices and parameters shall be given in the soil report:- (i) Sieve analysis. (ii) Atterberg limits. (iii) Natural moisture content. (iv) Particle size analysis test. (v) Bulk density. (vi) Specific gravity. (vii) Free swell index and swelling properties of soil. (viii) Organic matter in soil if any. (ix) Consolidation test (compressed index value). (x) Triaxial compression test and determination of shear parameters (c&Ø test) as per relevant IS. (xi) Harmful salts (complete investigation as already ref.) (xii) Void ratio. (xiii) Shear test on plastic/ semi plastic soil. (xiv) Direct shear test. (xv) Chemical analysis. (xvi) CBR value. (e) Ground Water table:- (i) Maximum and minimum levels of ground water in the area with source of information. (ii) Ground water table during the investigation. (iii) Chemical analysis of water sample to determine PH value, Sulphates and chlorides as per IS 456 2000
10 Nos Bore Holes @ upto 30 mtr deep each & 01 Nos Bore Holes @ upto 12 mtr deep each (1) Brief specification of work as above for any type of soils except Hard Bouldary Strata/Rocky strata. (2) Brief specification of work as above for only Hard Bouladry Strata/Rocky Strata. (If encountered during execution)
Note :- 1. The rate including all height & nothing extra shall be payable on A/C of Rotaty Drill, Diamond Bit, water scaffolding etc as required site condition, unless otherwise mentioned in the items, contractor should see the site before tendering. 2. Submission of six copies of ink signed test report with detailed description of field investigation soil classification and general nature of soil strata, water table, interpretation of test results, grain size distribution curve, compressive index curves, site plan etc. 3. The SBC of soil is required to be given as per following table. Calculation of bearing capacity will be governed generally as per IS 8009 (Pt-1) – 1976, IS 2720 (Pt-II)- 1980, IS 6403-1981, IS 1904-1986 & IS 1080-1985 and other relevant IS code and detailed calculations duly showing the various soil parameters/ indices shall be given in the soil report.:- Depth of foundation, Safe bearing capacity of soil in t〖/m〗^2 for fotting size RAFT/ MAJ Remark 1.2m x 1.2m 1.5m x 1.5m 2m x 2m 2.5m x 2.5m 1.0m 1.5m 2.0m 2.5m 4. With every sites Soil Investigation Report, a detailed site plan showing the approx location of each bore duly numbered as log of bore hole should be enclosed. Location of foundation of adjacent structures especially those that might be impacted by the proposed construction. 5. Every page of the Soil Investigation Report should have the Name of the job for which Soil investigation is being carried out. In case of multiple sites of a single job are being investigated name of each site shall be put on each page of the report pertaining to the site.
6. All pages of the Soil Investigation Report shall be serially numbered , stamped and signed by the agency carring out the soil investigation. Report should be scruitinized by GE & CWE and vatted by Dir Dign from HQ CE WAC AF Palam. 7. Transport charges including loading and unloading of heavy girder, T&P technician etc complete from laboratory to work site and back shall be deemed included in rates quated by bidders. 8. Photographic record of geo-explorations as well as testing shall also form part of the report. 9. The approximate type of construction as 8th storeys (G=7) MD Accn TYPE-II-60 Nos qtrs and 100000 ltrs capacity under ground water sump, utilization and dimensions of proposed building Lain plan attached, who based on Geotechnical investigations, should recommend type of foundation ( viz isolated/ combined footing, raft, pile etc). 10. The refusal strata shall be considered for field 'N' values more than 100.
Shree Hari Test House
MEENAKSHI GEOTECH
stage.html
html • 0.02 MB
finance_418060.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .