Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.1 L+₹1.0 L (2.13%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹48.5 L+₹1.4 L (3.02%)Rejected-Finance HOUSE NO 8 T SHIVPUR MAHADEV JHARKHANDI TUKRA NO 1 P O KUNRAGHAT DISTT GORAKHPUR UTTAR PRADESH 273008 | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Required Doc. not Uploaded | |
| 5 | Rejected-Technical | - | Rejected-Technical Required Doc. not Uploaded |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Spl repair to cook house cum dinning hall and certain Bldgs. at 39 GTC Varanasi Under GE (East) Allahabad.
2022_MES_543669_1
8591/E8
Open Tender
Civil Works
Item Rate
120 days
Varanasi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹96,000
Yes
13 Sept 2022
5 Aug 2022
29 Aug 2022
5 Aug 2022
27 Aug 2022
22 Aug 2022
5 Aug 2022 - 12 Aug 2022
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, including cutting of reinforcement as required to facilitate demolition, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store, removing rubbish off the premises, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, size of each tile shall be 600mm x 600mm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, size of each tile shall be 600mm x 600mm, as in vertical surfaces such as skirting / dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 10 mm thick backing coat in CM 1:4, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with flyash bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed.
Brickwork with flyash bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed. [Except Brick]
Brickwork in half brick thick walls with fly ash bricks, straight or curved on plan exceeding 6metre mean radius, built in CM 1:4, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water including removing of all rubbish off from the site, complete all as specified and directed.
Rendering 15mm thick, on faces of brick work or concrete surfaces in cement mortar 1:6, finished surface even and fair, complete all as specified and directed.
Rendering 10mm thick, on faces of brick work or concrete surfaces in cement mortar 1:4, finished surface even and fair, complete all as specified and directed.
Rendering 5mm thick in CM 1:3 on concrete surfaces of ceilings, finishing the surface even and smooth, complete all as specified and directed.
GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and directed.
Complete removal of existing treatment by scrapping with machnical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.
Waterproof cement based putty @ 1 Kg (undiluted) per sqm of average thickness 1 mm over the New plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface.
One coat of acrylic waterbased interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subsequent coats.
Preparation of new or old plastered surfaces of walls and applying two coats of acrylic emulsion paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
One coat of acrylic water based exterior grade primer @0.9 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
Two coats of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. Note for Item No 14 to 19 above (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b.) The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected.
RCC type B-1, 1:2:4, using 20mm graded stone aggregate as in beams, beam haunchings, girders, bressummers, lintels, cantilevers, lintetls over 1.5 m span, complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Formwork to rough finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutters from the frame) area exceeding 1.5 sq.m but not exceeding 4.0 sq.m each and removing from site, complete all as specified and directed..
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Resecuring or easing and adjuisting without taking down shutter of any description exceeding 1 sq.m but not exceeding 2sq.m each, complete all as specified and directed..
Resecuring or easing and adjuisting with refixing in other opening with taking down shutter of any description exceeding 1 sq.m but not exceeding 2sq.m each, complete all as specified and directed..
Powder coated aluminium window / CSW / Ventilator with powder coated aluminium anodized frame of aluminium section 62.5 x 37 x 1.5 mm thick with shutters having styles & rails of powder coated aluminium section 44.45 x 44.45 x 1.5mm thick including jointing cleats, glazing clips, rubber packing, aluminium snap beading, screws anodized aluminium fittings such as hinges, tower bolts, handles etc including 5.5mm thick ordinary plain glass complete including providing and fixing aluminium chequered grill of anodized section of mesh 50 x 50mm of 08 mm dia of aluminium bar fixed to frame with 20 x 2mm aluminium flat with screw and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified & directed.
Powder coated aluminium door single leaf sliding with powder coated aluminium frame of section 62.5 x 37 x 1.5 mm thick, shutter with bottom & middle rail of section 112.50 x 37 x 1.5mm thick, shutter with bottom & middle rail of section 112.50 x 37 x 1.5mm thick and styles & top rail of section 83 x 37 x 2.5 mm thick with centrally locking arrangement with lock make of 'GODREJ' or 'LINK' seven lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of sliding roller and glazing with 5.5mm thick ordinary plain glass including necessary fittings, fixtures & aluminium snap beads complete all as specified & directed.
Solar/ sun control film having 25 micron reflective type sticked to glass panes of aluminium doors or windows as required as per instruction of manufacturer complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of plain colour PVC sheet and edges to be painted to match with printed sheet, complete all as specified and directed.
Factory made wood grain printed solid PVC door shutters 28 to 30 mm thick (stiles) but wire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes, the wire gauge shall be stretched to tighten firmly, complete all as specified and directed.
Preparation of old wooden surfaces and applying one coat of synthetic enamel paint on old wooden surfaces of any description, over 10 cm width or girth, complete all as specified and directed.
Preparation of old steel and iron surfaces over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Preparation of new steel and iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm crushed stone aggregate) as in fixing of hold fasts with and including provision of necessary form work if required complete all as specified and directed..
Aluminium anodised, barrel tower bolts of 200 mm length, extruded section, complete all as specified and directed.
Brass barrel tower bolts, 200 mm long , with cast or sheet barrel and rolled or cast bolts and fixed all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed 300 mm long, fixed in repair, complete all as specified and directed.
Butt hinges, 100 mm long, medium weight, cold rolled mild steel, complete all as specified and directed.
Aluminium handles, 150mm size, cast type, anodised, complete all as specifeid and directed.
Aluminium handles, 100mm size, cast type, anodised, complete all as specifeid and directed.
Brass handles, 150mm size, complete all as specified and directed.
Second class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including butt hinge etc & all necessary labours; articles n exc 200 cu. cm each, complete all as specified and direcetd.
Butt hinges, 50 mm long, medium weight, cold rolled mild steel, in repair, complete all as specified and directed..
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, in repair, complete all as specifed and direcetd.
Sheet glass, 3 mm thick, ordinary quality and glazing with oil putty in squares, not exceeding 0.5 sq. m in each pane, in repair, complete all as specified and directed.
Dismantling of timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in framed work, complete all as specified and directed.
Second class hard-wood in scantlings as in timber framed and fixed all as specified and directed.
Preparation of surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosote Oil, complete all as specified and directed.
Dismantling of AC corrugated or semi corrugated sheet including AC ridges as in roof or wall covering, complete all as specified and directed..
Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa, as in roof covering / cladding to wall fixed with welf tapping screws, complete all as speified and directed .
Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa, as in roof covering / cladding to wall fixed with welf tapping screws, complete all as speified and directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for any type of work, complete all as specified and directed.
Rolled mild steel sections conforming to Gde Fe-410-0 or Fe-310-0 as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet, complete all as specified and directed..
Supply and fixing in repair E-board Make: Everest, Design "Lake and Hill" of size 605 x 605 x 4mm thick white prelaminated set embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section (White powder coated). The framework shall comprise of main runner made from 0.33mm thick GS sheet and of size 24 x 32 x 300mm and secured at 1200mm maximum centres securely fixed to structural soffits with hangers of 2mm dia GI wire to be fixed with approved rawl plugs, adjusters and screws. Flush fitting of 1200mmm long cross Tee (with double stiching) to be interlocked between main runners at 600mm centre to form 1200 x 1600 mm modules cross tee longer than 600mm to be supported independently. 600 x 600mm doubles to be formed by fittings 600mm long cross tee centrally between the 1200mm cross tee. Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19 x 19 mm and 300mm long of white colour all as per manufacturers instructions, fixed in reapir, complete all as specified and directed. Make of Frame work : Armstong or equivalent
Taking down existing water proofing treatment any thickness & removing the debris from the premises to a distance exc 250m from the MOD land including cleaning/washing down and keeping surfaces clean complete all as specified and as directed.
Plain Cement concrete 1:2:4, type B-1 (20 mm crushed stone aggregate) as in roof kerbs or mud stops, roof padding and miscellaneous works using water proofing compound, complete all as specified and directed. NOTE:- Water proofing compound shall be paid separately under respective item of this Schedule.
Providing water proofing treatment over cleaned roof surface with APP modified bitumenous membrane weight not less than 3 kg per sq.m comprising of the following and testing of following: (a) 10 mm thick rendering or screed bed or bedding layer in cement sand mortar 1:4 mixed with water proofing compound @ 3% by weight of cement, finished surface even and fair. (b) One coat of Bitumen primer confirming to IS-3384-1965 @ 0.3 lit per sqm. (c) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sq.m confirming to IS-702-1998 for water proofing membrane. (d) Providing APP modified polymeric water proofing membrane having weight not less than 3 kg per sq.m with 100 mm wide side or end lap and joint sealed with flamed torched pasted over full length. (e) Again Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sq.m confirming to IS-702-1998 for water proofing membrane. (f) Spreading of coarse sand over entire bitumen surface and topping with 40mm thick brick tiles laid over and including provision of 15 mm thick screed bed in CM 1:6 and joints shall be pointed with CM 1:3, complete all as specified and directed. Note: Water proofing compound to be measured and paid separately.
Supply only integral water proofing compound, complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
Plain cement concrete 1:3:6, type C1 (using 20 mm graded crushed stone aggregate), 75mm thick, as in plinth protection, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, size of each tile shall be 400mm x 400mm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles as in vertical surface of walls such as skirting / dado and risers to steps, size of tile shall be 450mm x 300mm x 7-8 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match the colour or shade of tiles, laid over and including provison of 10 mm thick rendering as in backing coat of tiles in cement mortar 1:4, complete all as specified and directed.
Galvanised Steel water tubes medium grade in any size or length galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 15mm dia, fixed in repair, complete all as specified and directed.
Galvanised Steel water tubes medium grade in any size or length galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 20mm dia, fixed in repair, complete all as specified and directed.
Galvanised Steel water tubes medium grade in any size or length galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 25mm dia, fixed in repair, complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 20mm bore, fixed in repair, complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, ISI marked, double layered hoisted and fixed in position including connecting up pipes including ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20mm bore size (minimum weight 210 gms), fixed in repair, complete all as specified and directed.
Nipple suitable for HDPE water tank, 20mm bore, (Minimum weight 45gms ), complete all as specified and directed.
Vitreous china wash hand basin white flat back of size 550mm x 400mm excluding chain, plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets, fixed in repair, complete all as specified and directed.
Soap dish, chromium plated, fixed in repair, complete all as specified and directed.
Tubular towel rail of brass chromium plated, 20 mm dia, 'D' type, 60 cm long between flanges, fixed in repair, complete all as specified and directed.
Bib taps, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule for 15mm bore, in repair, complete all as specified and directed.
RCC M-25 (design mix) using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Formwork to flat rough finished surface of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping), complete all as specified and directed.
RCC M-25 (design mix) using 20mm graded stone aggregate as in beams, beam haunchings, girders, bressummers, lintels, cantilevers, lintetls over 1.5 m span, complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Angle valve, cast copper alloy chromium plated with long shank and cup, screwed down, high pressure, with crutch or butterfly handle, fancy type, 15mm bore, screwed for iron pipe or for unions, fixed in repair, complete all as specified and directed.
Grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms), fixed in repair, complete all as specified and directed.
Stainless steel tubing of 25mm dia with PVC coating for curtain rod fancy type including fancy type PVC rings and CP brackets, socket and knobs (wall to wall or flush to wall) for securing to curtain rod, fixed in repair, complete all as specified and directed.
Door closer hydraulically regulated, Aluminium die cast, designation No. 3, universal type, suitable for aluminium door shutters and of weight between 61 to 80 kg and fixed, complete all as specified and directed.
Prelaminated particle board, 18/19 mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, fixed in repair, complete all as specified and directed.
Continuous (piano) hinges mild steel bright finish or electro galvanized 30mm width of flaps (when open), complete all as specified and directed..
Aluminium anodised hasp and staple, 150mm size, safety type with mild steel hinge pin including bolt to hinge plate, fixed with screws, fixed in repair, complete all as specified and directed..
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded in any mortar, complete all as specified and directed.
Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types and the like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and including 15mm thick screed bed in CM 1:4, complete all as specified and directed .
PVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in floors or trenches, fixed in repair, complete all as specified and directed..
PVC (SWR) bends of any radius and 75mm bore, jointed with adhesive, fixed in repair, complete all as specified and directed..
PVC (SWR) bends of any radius and 110mm bore, jointed with adhesive, fixed in repair, complete all as specified and directed..
PVC (SWR) junction single, (Single T) equal or unequal, 75 mm bore, jointed with adhesive, fixed in repair, complete all as specified and directed..
PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), fixed in repair, complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, fixed in repair, complete all as specified and directed.
Kitchen sink with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm, fixed in repair, complete all as specified and directed.
PCC 1:3:6 type C-1 using 20mm crushed stone aggregate as in surface channels and drains including necessary form work if required complete all as specified and directed..
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceilings and applying three coats of white wash, complete all as specifed and directed.
Preparation of old plastered surfaces of walls and applying two coats of white wash, complete all as specifed and directed.
Taking down carefully point wiring of any type and any description / caping or concealed [light point, fan point or socket point] including removal of battens, pipes, plug sockets, switches, shades, ceiling roses, light fittings etc complete and making good disturbed surface to match the exisitng, complete all as specified and directed.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, including provision of concealed pressed steel terminal box of required size not less than 1.6 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 3.0 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 1.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed for the following:-
(a) One light / fan / bell / exhaust fan point, controlled by one one-way 5Amp switch
(b) One 3 pin, 5 Amp socket outlet point on an independent board.
(c) One 3 pin, 5 Amp socket outlet on the same board with other switches
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 2.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/ fan/ bell/ buzzer/ exhaust fan point controlled by one, one way 5 Amp switch including provision of concealed opressed steel terminal box of required size not less than 1.6 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 3.0 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 2.5 sq.mm FR type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed.
Switch piano, flush type single pole, one way 5/6 Amp 230 volts all as specified and directed.
Socket outlet, 2 in 1, 2/3 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Lamp holder, PVC/polycarbonate body with back plate/ cord grip cap suitable for batten/ angle/ pendent fittings, complete all as specified and directed.
Switch socket combination 2 in 1, 6 pin, 16 Amp flush type universal, 240 Volts, complete all as specified and directed.
Ceiling rose, single phase, PVC / polycarbonate, insulated body, three terminals, surface bakelite sheet 63.5mm dia, complete all as specified and directed.
LED retrofit lamp of capacity 12/15 Watt, B-22 holder base with polycarbonate body and aluminium heat sink warm white complete including taking down old / unserviceable CFL / bulb, complete all as specified and directed.
Ceiling fan regulator flush type, electronic, rotary stepped type, AC 230 V, suitable for any type of ceiling fan, complete all as specified and directed.
LED edgelite linear and compact 9W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser including taking down old unserviceable light / mirror fittings, complete all as specified and directed. MAKE:- Cat No. LHEXAPRP7PN1W009 of HAVELLS or techno-commercially equivalent model in Philips / Crompton / Bajaj
LED tube light fitting, 20/22 Watt, decorative type, slim aluminium square profile, high Lumen output, energy efficient, direct surface mounting including connecting up with twin core PVC insulated copper conductor of suitable size, including taking down the old unserviceable light fittings, complete all as specified and directed.
Sheet metal enclosure for MCB DBs SPN, 8 way, double door, vertical type, 240 V with 200 Amps rated bus bar, complete with incoming / outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs, complete all as specified and directed.
Isolator / MCB SP 6 to 40 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, fixed in repair, complete all as specified and directed.
Isolator/ MCB SPN 40 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, fixed in repair, complete all as specified and directed.
Sheet metal enclosure for VTPN DBs, 4 way, double door, IP-43 protection, vertical type, 240 V with 200 Amps rated bus bar, complete with suitable for 1 x MCCB 125 Amp as incomer and MCB SPN as outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs, complete all as specified and directed.
MCCB 125 Amp, 4 pole, 415 Volt, conforming to 'B' curve, 16kA breaking capacity, complete all as specified and directed.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC rigid conduit 20mm dia and accessories connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly including taking down existing sub main wiring any type and making good disturbed surfaces to match with existing including sinking of boxes , complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe light grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
Exhaust fans of metallic body heavy duty AC single phase 230 / 240 V, of size 300 mm sweep, 900 rpm, with bracket, louver, nuts and bolts including connection with 1.5sq.mm PVC copper flexible wire of appropriate length, complete all as specified and directed. Make: Havells Model Turbo Power or or techno-commercially equivalent make as equivalent make as approved by GE.
Supplying, testing and installation of energy efficient five star rating storage water heater (geyser), 50 litre capacity, storage type with copper inner tank and heating element upto 2 KW, complete with all accessories such as safety valve, thermostate, NRV, connection piece, etc, complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and directed.
RVRconstructon
M/s Rajeev Kumar
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .